10 A Circuit Breaker 140

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

GV2ME14AE11TQ

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail And Panel Mount

690 V

10 A

Screw And Snap On

-20 °C (-4 °F)

3 kA

Push Button

Bulk

3.504 in (89 mm)

1.752 in (44.5 mm)

IK04; IP20

Trip

3.079 in (78.2 mm)

EN; IEC

3

60 °C (140 °F)

1658-G21-02-P10-10A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Inline/Holder

240 V

28 V

10 A

Tab/Blade

-20 °C (-4 °F)

200 A

Manual Reset

1.26 in (32 mm)

0.551 in (14 mm)

Trip Free

1.563 in (39.7 mm)

CSA; CUL; UL; VDE

1

60 °C (140 °F)

W33-S1N1Q-10

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

50 V

10 A

Quick Connect

3 s

Rocker

1.89 in (48.01 mm)

0.98 in (24.89 mm)

Series Trip

1.724 in (43.79 mm)

2

C13-B9-46-610-546-R

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

10 A

Screw

-40 °C (-40 °F)

5 kA

Rocker

2.5 in (63.5 mm)

2.265 in (57.53 mm)

Corrosion/Moisture Resistant

Series Trip

1.85 in (47 mm)

CSA; TUV; UL

3

85 °C (185 °F)

MS14154-10L

Sensata Technologies

Thermal Circuit Breaker

Panel Mount-Threaded

120 V

10 A

Screw

2 kA

Push-Pull

1.84 in (46.73 mm)

0.781 in (19.84 mm)

Corrosion Resistant; Moisture Resistant

1.84 x 0.781 x 1.384 in (46.73 x 19.84 x 35.15 mm)

Trip Free

1.436 in (36.47 mm)

1

C13-B9-46-610-543-R

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

10 A

Screw

-40 °C (-40 °F)

5 kA

Rocker

2.5 in (63.5 mm)

2.265 in (57.53 mm)

Corrosion/Moisture Resistant

Series Trip

1.85 in (47 mm)

CSA; TUV; UL

3

85 °C (185 °F)

410212

Legrand

Thermal Magnetic Circuit Breaker

DIN Rail Mount

400 V

10 A

Snap On

-25 °C (-13 °F)

50 kA

Toggle Handle

Bulk

4.106 in (104.3 mm)

3.154 in (80.1 mm)

Manual On/Off

3.11 in (79 mm)

IEC

3

70 °C (158 °F)

5SU1356-7KK10

Siemens

Thermal Circuit Breaker

DIN Rail Mount

230 V

10 A

Snap On

-25 °C (-13 °F)

5SU1356-7KK10

3.543 in (90 mm)

1.417 in (36 mm)

Environment/Moisture Resistant

3.543 x 1.417 x 2.756 in (90 x 36 x 70 mm)

Trip

2.756 in (70 mm)

CCC; CE; GOST; IMQ; OVE; VDE

1

55 °C (131 °F)

CLB-103-27E6A-B-A

Carling Technologies

Thermal Circuit Breaker

Panel Mount

250 V

32 V

10 A

Quick Connect

-10 °C (14 °F)

300 A

Rated breaking capacity at 32 VDC: 2500 A

Push To Reset

1.378 in (35 mm)

0.571 in (14.5 mm)

Fire Resistant

Series Trip

1.693 in (43 mm)

CE; TUV; UL

1

60 °C (140 °F)

1020069

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

125 V

10 A

Snap On

-35 °C (-31 °F)

5 kA

Handle

Bulk

3.205 in (81.4 mm)

1.39 in (35.3 mm)

IP20

Trip

2.587 in (65.7 mm)

CUL; TUV; UL

2

70 °C (158 °F)

483-G411-K1M1-A1S0ZN--10A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

28 V

10 A

Screw

-55 °C (-67 °F)

2.5 kA

Rated breaking capacity at 28 VDC: 6000 A

Push-Pull

0.768 in (19.5 mm)

0.559 in (14.2 mm)

IP40; IP00

0.768 x 0.559 x 1.22 in (19.5 x 14.2 x 31 mm)

Tease-Free And Trip-Free

1.22 in (31 mm)

1

125 °C (257 °F)

5SU1354-6KK10

Siemens

Equipment Leakage Circuit Breaker

DIN Rail Mount

230 V

10 A

Screw And Snap On

10 kA

Handle

3.543 in (90 mm)

1.417 in (36 mm)

IP20

3.543 x 1.417 x 3.031 in (90 x 36 x 77 mm)

Trip

3.031 in (77 mm)

2

70 °C (158 °F)

CLB-103-27E3A-W-A

Carling Technologies

Thermal Circuit Breaker

Panel Mount

250 V

32 V

10 A

Quick Connect

-10 °C (14 °F)

300 A

Rated breaking capacity at 32 VDC: 2500 A

Push To Reset

1.378 in (35 mm)

0.571 in (14.5 mm)

Fire Resistant

Series Trip

1.693 in (43 mm)

CE; TUV; UL

1

60 °C (140 °F)

CLB-103-27E3N-B-F

Carling Technologies

Thermal Circuit Breaker

Panel Mount

250 V

32 V

10 A

Screw

-10 °C (14 °F)

300 A

Rated breaking capacity at 32 VDC: 2500 A

Push To Reset

1.378 in (35 mm)

0.571 in (14.5 mm)

Fire Resistant

Series Trip

1.693 in (43 mm)

CE; TUV; UL

1

60 °C (140 °F)

CLB-103-27E3N-W-F

Carling Technologies

Thermal Circuit Breaker

Panel Mount

250 V

32 V

10 A

Screw

-10 °C (14 °F)

300 A

Rated breaking capacity at 32 VDC: 2500 A

Push To Reset

1.378 in (35 mm)

0.571 in (14.5 mm)

Fire Resistant

Series Trip

1.693 in (43 mm)

CE; TUV; UL

1

60 °C (140 °F)

CLB-103-27E6N-W-A

Carling Technologies

Thermal Circuit Breaker

Panel Mount

250 V

32 V

10 A

Quick Connect

-10 °C (14 °F)

300 A

Rated breaking capacity at 32 VDC: 2500 A

Push To Reset

1.378 in (35 mm)

0.571 in (14.5 mm)

Fire Resistant

Series Trip

1.693 in (43 mm)

CE; TUV; UL

1

60 °C (140 °F)

MD1-B-34-610-1-A42-B-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

125 V

80 V

10 A

Quick Connect

-40 °C (-40 °F)

1 kA

Rocker

1.375 in (34.93 mm)

0.68 in (17.27 mm)

Chemical/Corrosion/Moisture Resistant

Series Trip

1.53 in (38.86 mm)

UL; CSA

1

85 °C (185 °F)

W58-XB1A4A-10

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

50 V

10 A

Quick Connect

1 kA

6 s

Rated breaking capacity at 50 VDC: 2000 A

Push To Reset

1.375 in (34.93 mm)

0.66 in (16.76 mm)

1.375 x 0.66 x 1.375 in (34.93 x 16.76 x 34.93 mm)

Series Trip

1.375 in (34.93 mm)

CSA; UL

1

3120-F323-P7T1-W19FG4-10A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

250 V

50 V

10 A

Tab/Blade

-30 °C (-22 °F)

5 kA

Rocker

Bulk

2.126 in (54 mm)

0.984 in (25 mm)

Corrosion/Moisture Resistant; IP00; IP40

Trip Free

1.299 in (33 mm)

CSA; UL

2

60 °C (140 °F)

3RV2011-1JA20

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

10 A

Snap On

-20 °C (-4 °F)

4 kA

Interrupting current max at 450 VDC: 10000 A

Handle

4.173 in (106 mm)

1.772 in (45 mm)

IP20

4.173 x 1.772 x 3.815 in (106 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

Instantaneous

4435.005

Schurter Ag

Thermal Circuit Breaker

Panel Mount

415 V

10 A

Quick Connect

-30 °C (-22 °F)

2 kA

Rocker

Bulk

1.594 in (40.5 mm)

1.417 in (36 mm)

IP40

Manual On/Off

1.736 in (44.1 mm)

CCC; CUL; UL; VDE

3

60 °C (140 °F)

CA1-B2-12-610-121-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

480 V

150 V

10 A

Stud

-40 °C (-40 °F)

10 kA

Handle

1.85 in (47 mm)

0.75 in (19.05 mm)

Series Trip

2.5 in (63.5 mm)

UL

1

85 °C (185 °F)

CA1-B2-12-610-121-D

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

480 V

150 V

10 A

Stud

-40 °C (-40 °F)

10 kA

Handle

1.85 in (47 mm)

0.75 in (19.05 mm)

Series Trip

2.5 in (63.5 mm)

UL

1

85 °C (185 °F)

CA1-B2-12-610-121-MG

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

240 V

80 V

10 A

Stud

-40 °C (-40 °F)

10 kA

Handle

1.85 in (47 mm)

0.75 in (19.05 mm)

Series Trip

2.5 in (63.5 mm)

UL

1

85 °C (185 °F)

CA2-B2-12-610-121-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

480 V

150 V

10 A

Stud

-40 °C (-40 °F)

10 kA

Handle

1.85 in (47 mm)

1.515 in (38.48 mm)

Series Trip

2.5 in (63.5 mm)

UL

2

85 °C (185 °F)

CT1-B2-12-610-121-MG

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

80 V

10 A

Stud

-40 °C (-40 °F)

10 kA

Handle

2.5 in (63.5 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.85 in (47 mm)

CSA; UL

1

85 °C (185 °F)

QOU110

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

240 V

10 A

10 kA

4.05 x 0.75 x 2.95 in (102.87 x 19.05 x 74.93 mm)

CSA; IEC; UL

1

2CU10L

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

10 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.291 in (109 mm)

1.378 in (35 mm)

IP20

Trip

2.362 in (60 mm)

CE, CUL, UL

2

60 °C (140 °F)

3120-F324-P7T1-W01D-10A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

250 V

50 V

10 A

Quick Connect

-30 °C (-22 °F)

100 A

Rocker

2.205 in (56 mm)

0.827 in (21 mm)

Corrosion Resistant

2.205 x 0.827 x 1.299 in (56 x 21 x 33 mm)

Manual On/Off

1.299 in (33 mm)

CCC; CSA; UL; VDE

2

60 °C (140 °F)

AJ1-B2-16-610-444-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

80 V

10 A

Screw

-40 °C (-40 °F)

7.5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Rocker

2.156 in (54.76 mm)

0.745 in (18.92 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

FAZ-B10/2

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

96 V

10 A

Snap On

-40 °C (-40 °F)

15 kA

Toggle

3.15 in (80 mm)

1.394 in (35.4 mm)

IP20

Manual On/Off

2.362 in (60 mm)

CCC; CE; CSA; IEC; UL; VDE

2

75 °C (167 °F)

Short

FAZ-B10/2-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

10 A

Snap On

10 kA

Toggle

1.39 in (35.3 mm)

Manual On/Off

2

Low Inrush

FAZ-B10/2-NA-L

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

240 V

10 A

Snap On

10 kA

Toggle

Manual On/Off

2

FAZ-C10/1-NA-DC-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

125 V

10 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle

Bulk

4.134 in (105 mm)

0.697 in (17.7 mm)

Trip Free

1.772 in (45 mm)

CSA; UL

1

75 °C (167 °F)

FAZ-C10/2-NA-DC

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

250 V

10 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle

4.134 in (105 mm)

1.39 in (35.3 mm)

Trip Free

1.772 in (45 mm)

CSA; UL

2

75 °C (167 °F)

LELB1-1-51-10.0-A1-01-V

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

125 V

10 A

Screw

5 kA

Toggle

2.49 in (63.24 mm)

0.75 in (19.05 mm)

Corrosion/Moisture Resistant

Trip Free

1.859 in (47.22 mm)

CCC; VDE

1

LELB1-1-52-10.0-A1-01-V

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

125 V

10 A

Screw

5 kA

Toggle

2.49 in (63.24 mm)

0.75 in (19.05 mm)

Corrosion/Moisture Resistant

Trip Free

1.859 in (47.22 mm)

CCC; VDE

1

MA1-4-14-610-1-A22-B-M

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

80 V

10 A

Quick Connect

-40 °C (-40 °F)

600 A

Rocker

1.375 in (34.93 mm)

0.68 in (17.27 mm)

Chemical/Corrosion/Moisture Resistant

Series Trip

1.53 in (38.86 mm)

UL; CSA

1

85 °C (185 °F)

ME1-4-14-610-1-A16-2-T

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

80 V

10 A

Quick Connect

-40 °C (-40 °F)

600 A

Rocker

1.375 in (34.93 mm)

0.68 in (17.27 mm)

Chemical/Corrosion/Moisture Resistant

Series Trip

1.53 in (38.86 mm)

UL

1

85 °C (185 °F)

MS26574-10

Eaton Corporation

Thermal Circuit Breaker

Panel Mount-Threaded

120 V

28 V

10 A

Screw

500 A

Standard: MIL-C-5809, rated breaking capacity at 28 VDC: 2000 A

0.78 in (19.81 mm)

0.593 in (15.06 mm)

0.78 x 0.593 x 1.251 in (19.81 x 15.06 x 31.78 mm)

1.251 in (31.78 mm)

MS

1

PXL-C10/1

Eaton Corporation

Magnetic Circuit Breaker

DIN Rail Mount

230 V

10 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle

IP20

Trip

2.776 in (70.5 mm)

1

75 °C (167 °F)

0903030

Phoenix Contact

Magnetic Circuit Breaker

DIN Rail Mount

10 A

Screw

0 °C (32 °F)

Bulk

3.15 in (80 mm)

0.492 in (12.5 mm)

IP20

3.268 in (83 mm)

CE, UL

50 °C (122 °F)

0903038

Phoenix Contact

Magnetic Circuit Breaker

DIN Rail Mount

10 A

Screw

0 °C (32 °F)

Bulk

3.15 in (80 mm)

0.492 in (12.5 mm)

IP20

3.268 in (83 mm)

CE, UL

50 °C (122 °F)

1-1393253-4

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

10 A

Quick Connect

-40 °C (-40 °F)

5 kA

30 ms

Toggle

2 in (50.8 mm)

1.5 in (38.1 mm)

Series Trip

1.64 in (41.66 mm)

2

85 °C (185 °F)

4-1393248-7

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

50 V

10 A

Quick Connect

1 kA

3 s

Rocker

1.89 in (48.01 mm)

0.98 in (24.89 mm)

Series Trip

1.724 in (43.79 mm)

2

4435.0195

Schurter Ag

Thermal Circuit Breaker

Panel Mount

240 V

60 V

10 A

Quick Connect

-30 °C (-22 °F)

2 kA

Rocker

Bulk

1.417 in (36 mm)

1.142 in (29 mm)

IP40

Trip Free

1.736 in (44.1 mm)

CCC; CSA; GB; IEC; UL; VDE

2

60 °C (140 °F)

5SL6110-7

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

60 V

10 A

Snap On

-25 °C (-13 °F)

6 kA

3.543 in (90 mm)

0.709 in (18 mm)

IP20; Sealed

3.543 x 0.709 x 2.992 in (90 x 18 x 76 mm)

Trip

2.992 in (76 mm)

CE; CEBEC; TSE; VDE

1

45 °C (113 °F)

5SU1354-7KK10

Siemens

Equipment Leakage Circuit Breaker

DIN Rail Mount

230 V

10 A

Screw And Snap On

10 kA

Handle

3.543 in (90 mm)

1.417 in (36 mm)

IP20

3.543 x 1.417 x 3.031 in (90 x 36 x 77 mm)

Trip

3.031 in (77 mm)

2

70 °C (158 °F)

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.