20 A Circuit Breaker 101

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

1620-3-20A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

12 V

20 A

Quick Connect

-40 °C (-40 °F)

150 A

Reset Button

0.524 in (13.3 mm)

0.276 in (7 mm)

Corrosion Resistant; IP00; IP40

Trip

0.984 in (25 mm)

1

85 °C (185 °F)

25218

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

20 A

Snap On

-25 °C (-13 °F)

10 kA

Rated breaking capacity at 250 VDC: 50000 A

Toggle

2.874 in (73 mm)

2.835 in (72 mm)

Environment/Moisture Resistant

2.874 x 2.835 x 3.189 in (73 x 72 x 81 mm)

Trip

3.189 in (81 mm)

EN; IEC

4

60 °C (140 °F)

W67-X2Q12-20

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

20 A

Quick Connect

-40 °C (-40 °F)

5 kA

2.2 s

Toggle

2 in (50.8 mm)

0.75 in (19.05 mm)

Fungus Resistant; Moisture Resistant

2 x 0.75 x 1.64 in (50.8 x 19.05 x 41.66 mm)

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

Standard

W67-X2Q1220

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

20 A

Quick Connect

2.2 s

Toggle

Series Trip

1

W58-XB1A4A-20

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

50 V

20 A

Quick Connect

1 kA

6 s

Rated breaking capacity at 50 VDC: 2000 A

Push To Reset

1.375 x 0.66 x 1.375 in (34.93 x 16.76 x 34.93 mm)

Series Trip

1

W28-XQ1A-20

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

32 V

20 A

Quick Connect

1 kA

2.2 s

Push To Reset

0.625 in (15.88 mm)

0.54 in (13.72 mm)

0.625 x 0.54 x 1.535 in (15.88 x 13.72 x 38.99 mm)

Series Trip

1.535 in (38.99 mm)

CSA; SEV; UL; VDE

1

W28-XQ1A20

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

32 V

20 A

Quick Connect

2.2 s

Push To Reset

Series Trip

1

W28XQ1A20

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

32 V

20 A

Quick Connect

2.2 s

Push To Reset

Series Trip

1

W68-X2Q12-20

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

20 A

Quick Connect

-40 °C (-40 °F)

5 kA

2.2 s

Toggle

2 in (50.8 mm)

1.5 in (38.1 mm)

Fungus Resistant; Moisture Resistant

2 x 1.5 x 1.64 in (50.8 x 38.1 x 41.66 mm)

Series Trip

1.64 in (41.66 mm)

CSA; UL

2

85 °C (185 °F)

Standard

MS3320-20

Defense Logistics Agency

Thermal Circuit Breaker

Panel Mount

120 V

28 V

20 A

Screw

-55 °C (-67 °F)

2 kA

Rated breaking capacity at 28 VDC: 6000 A

Push-Pull

0.781 in (19.84 mm)

0.593 in (15.06 mm)

Corrosion Resistant; Moisture Resistant

0.781 x 0.593 x 1.03 in (19.84 x 15.06 x 26.16 mm)

Trip Free

1.03 in (26.16 mm)

MIL-C-5809

1

121 °C (249.8 °F)

2TC2-20

Texas Instruments

Thermal Circuit Breaker

Panel Mount

120 V

28 V

20 A

Screw

2 kA

2TC2

Push-Pull

0.781 in (19.84 mm)

0.593 in (15.06 mm)

Corrosion Resistant

0.781 x 0.593 x 1.03 in (19.84 x 15.06 x 26.16 mm)

1.03 in (26.16 mm)

MS3320-20V

Eaton Corporation

Thermal Circuit Breaker

Panel Mount

120 V

28 V

20 A

Screw

-55 °C (-67 °F)

3.5 kA

Standard: MIL-C-5809, rated breaking capacity at 28 VDC: 6000 A

Push Button

0.781 in (19.84 mm)

0.593 in (15.06 mm)

Corrosion Resistant; Moisture Resistant

0.781 x 0.593 x 1.03 in (19.84 x 15.06 x 26.16 mm)

Trip

1.03 in (26.16 mm)

1

121 °C (249.8 °F)

4435.0013

Schurter Ag

Thermal Circuit Breaker

Panel Mount

240 V

60 V

20 A

Quick Connect

-30 °C (-22 °F)

2 kA

Rocker

Bulk

1.417 in (36 mm)

1.142 in (29 mm)

IP40

Trip Free

1.736 in (44.1 mm)

CCC; CSA; GB; IEC; UL; VDE

2

60 °C (140 °F)

4435.0002

Schurter Ag

Thermal Circuit Breaker

Panel Mount

240 V

60 V

20 A

Quick Connect

-30 °C (-22 °F)

2 kA

Rocker

Bulk

1.417 in (36 mm)

1.142 in (29 mm)

IP40

Trip Free

1.736 in (44.1 mm)

CCC; CSA; GB; IEC; UL; VDE

2

60 °C (140 °F)

3120-N321-P7T1-W19DG4-20A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

20 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

Corrosion/Moisture Resistant; IP00; IP40

Manual On/Off

CCC; CE; CSA; CQC; KTL; UL; VDE

2

60 °C (140 °F)

AA1-B0-34-620-3B1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

80 V

20 A

Screw

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

1620-2-20A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

12 V

20 A

Quick Connect

-40 °C (-40 °F)

150 A

Modified Reset

0.524 in (13.3 mm)

0.276 in (7 mm)

Corrosion Resistant; IP00; IP50

Trip

0.984 in (25 mm)

1

85 °C (185 °F)

1610-21-20A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Inline/Holder

32 V

20 A

Tab/Blade

-40 °C (-40 °F)

150 A

Push To Reset

0.787 in (20 mm)

0.236 in (6 mm)

Corrosion Resistant; IP00; IP30; IP54

Trip Free

0.945 in (24 mm)

UL

1

85 °C (185 °F)

2D20UM

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

80 V

20 A

Screw And Snap On

-25 °C (-13 °F)

10 kA

Handle

Bulk

3.516 in (89.3 mm)

1.378 in (35 mm)

IP20

Under Voltage Release

2.693 in (68.4 mm)

CSA; UL; VDE

2

55 °C (131 °F)

AC1-B0-14-620-343-D

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

80 V

20 A

Screw

-40 °C (-40 °F)

3 kA

Standards: MIL-PRF-55629, MIL-STD-202

Rocker

2.156 in (54.76 mm)

0.745 in (18.92 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL; VDE

1

85 °C (185 °F)

FAZ-D20/3

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

96 V

20 A

Snap On

-40 °C (-40 °F)

5 kA

Toggle

3.15 in (80 mm)

2.091 in (53.1 mm)

IP20

Trip Free

2.362 in (60 mm)

CSA; UL

3

167 °C (332.6 °F)

3RV2021-4BA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

20 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

3RV2021-4BA10

3.819 in (97 mm)

1.772 in (45 mm)

Moisture Resistant; IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

3.815 in (96.9 mm)

CCC; CSA; EAC; KTL; UL

3

60 °C (140 °F)

3RV2821-4BD10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

20 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

Rotary Handle

5.669 in (144 mm)

1.772 in (45 mm)

IP00; IP20

5.669 x 1.772 x 3.819 in (144 x 45 x 97 mm)

Trip

3.819 in (97 mm)

3

60 °C (140 °F)

W33-T2N1Q-20

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

50 V

20 A

Quick Connect

1 kA

3 s

Rocker

1.89 in (48.01 mm)

0.98 in (24.89 mm)

Series Trip

1.724 in (43.79 mm)

2

W33T2N1Q20

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

50 V

20 A

Quick Connect

1 kA

3 s

Rocker

1.89 in (48.01 mm)

0.98 in (24.89 mm)

Series Trip

1.724 in (43.79 mm)

2

CA2-B0-21-620-622-DG

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

120 V

20 A

Stud

-40 °C (-40 °F)

10 kA

Handle

2.5 in (63.5 mm)

1.515 in (38.48 mm)

Corrosion/Moisture Resistant

Series Trip

1.85 in (47 mm)

CSA; UL

2

85 °C (185 °F)

W91-X112-20

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

20 A

Stud

-40 °C (-40 °F)

5 kA

2.2 s

Toggle

2.5 in (63.5 mm)

0.75 in (19.05 mm)

Series Trip

1.845 in (46.86 mm)

1

85 °C (185 °F)

W91-X11220

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

20 A

Stud

-40 °C (-40 °F)

5 kA

2.2 s

Toggle

2.5 in (63.5 mm)

0.75 in (19.05 mm)

Series Trip

1.845 in (46.86 mm)

1

85 °C (185 °F)

3RV2721-4BD10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

20 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

Rotary Handle

5.669 in (144 mm)

1.772 in (45 mm)

IP00; IP20

5.669 x 1.772 x 3.819 in (144 x 45 x 97 mm)

Trip

3.819 in (97 mm)

3

60 °C (140 °F)

W58-XC4C12A-20

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

50 V

20 A

Quick Connect

1 kA

6 s

Push To Reset

1.375 in (34.93 mm)

0.66 in (16.76 mm)

Series Trip

1.375 in (34.93 mm)

1

W92-X112-20

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

20 A

Stud

-40 °C (-40 °F)

5 kA

2.2 s

Toggle

2.5 in (63.5 mm)

1.5 in (38.1 mm)

Series Trip

1.845 in (46.86 mm)

2

85 °C (185 °F)

IEG11-1-62F-20.0-A-00

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

240 V

20 A

Quick Connect

-40 °C (-40 °F)

2 kA

Toggle Handle

2 in (50.8 mm)

1.515 in (38.48 mm)

Corrosion/Moisture Resistant

Trip Free

1.687 in (42.85 mm)

VDE

2

85 °C (185 °F)

BB3-B0-26-620-121-D

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

20 A

Quick Connect

-40 °C (-40 °F)

1.5 kA

Toggle Handle

2 in (50.8 mm)

2.265 in (57.53 mm)

Corrosion/Moisture Resistant

Series Trip

1.73 in (43.94 mm)

CSA; UL; VDE

3

85 °C (185 °F)

3120-F321-P7T1-W01D-20A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

250 V

50 V

20 A

Quick Connect

-30 °C (-22 °F)

20 A

Rocker

2.126 in (54 mm)

0.827 in (21 mm)

Corrosion Resistant

2.126 x 0.827 x 1.299 in (54 x 21 x 33 mm)

Manual On/Off

1.299 in (33 mm)

CCC; CSA; UL; VDE

2

60 °C (140 °F)

CA3-B0-22-620-122-D

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

480 V

150 V

20 A

Stud

-40 °C (-40 °F)

10 kA

Handle

1.85 in (47 mm)

2.265 in (57.53 mm)

Series Trip

2.5 in (63.5 mm)

UL

3

85 °C (185 °F)

IEG1-1-61-20.0-91-V

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

240 V

20 A

Quick Connect

-40 °C (-40 °F)

2 kA

Toggle

2 in (50.8 mm)

0.75 in (19.05 mm)

Corrosion/Moisture Resistant

Trip Free

1.687 in (42.85 mm)

CCC; VDE

1

85 °C (185 °F)

AP17-1-61-203

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

240 V

20 A

Screw

-40 °C (-40 °F)

1 kA

Toggle

1.562 in (39.67 mm)

1.281 in (32.53 mm)

Corrosion Resistant; Sealed

Series Trip

1.78 in (45.21 mm)

2

100 °C (212 °F)

IEG11-1REC4-72-20.0-01-V

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

240 V

80 V

20 A

Quick Connect

-40 °C (-40 °F)

2 kA

Toggle Handle

2 in (50.8 mm)

1.515 in (38.48 mm)

Corrosion/Moisture Resistant

Trip Free

1.687 in (42.85 mm)

CCC; VDE

2

85 °C (185 °F)

3VA5120-6ED21-0AA0

Siemens

Thermal Circuit Breaker

Panel Mount

600 V

250 V

20 A

Screw

-25 °C (-13 °F)

65 kA

Toggle

5.5 in (139.7 mm)

2 in (50.8 mm)

IP40

5.5 x 2 x 3 in (139.7 x 50.8 x 76.2 mm)

Trip

3 in (76.2 mm)

2

70 °C (158 °F)

5SU1354-7KK20

Siemens

Equipment Leakage Circuit Breaker

DIN Rail Mount

230 V

20 A

Screw And Snap On

10 kA

Handle

3.543 in (90 mm)

1.417 in (36 mm)

IP20

3.543 x 1.417 x 3.031 in (90 x 36 x 77 mm)

Trip

3.031 in (77 mm)

2

70 °C (158 °F)

6-1393250-7

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

32 V

20 A

Quick Connect

1 kA

2.2 s

Push To Reset

0.76 in (19.31 mm)

0.76 in (19.31 mm)

Series Trip

1.535 in (38.99 mm)

1

CX2-B0-14-620-22A-13G

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

500 V

20 A

Screw

-40 °C (-40 °F)

10 kA

Handle

3.672 in (93.26 mm)

1.515 in (38.48 mm)

Corrosion/Moisture Resistant

Series Trip

2.264 in (57.51 mm)

UL

2

85 °C (185 °F)

GFL2D200302

Altech

Magnetic Circuit Breaker

DIN Rail Mount

240 V

20 A

Snap On

10 kA

Toggle

4.134 in (105 mm)

1.378 in (35 mm)

Trip

2.362 in (60 mm)

CUL; UL

1

MS26574-20L

Eaton Corporation

Thermal Circuit Breaker

Panel Mount-Threaded

120 V

28 V

20 A

Screw

500 A

Standard: MIL-C-5809, rated breaking capacity at 28 VDC: 2000 A

0.78 in (19.81 mm)

0.593 in (15.06 mm)

0.78 x 0.593 x 1.251 in (19.81 x 15.06 x 31.78 mm)

1.251 in (31.78 mm)

MS

1

QCGFEP1020

Eaton Corporation

Equipment Leakage Circuit Breaker

DIN Rail Mount

240 V

20 A

Snap On

10 kA

Toggle

Trip

CSA; UL

1

40 °C (104 °F)

1658-G21-02-P10-20A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Inline/Holder

240 V

28 V

20 A

Tab/Blade

-20 °C (-4 °F)

200 A

Manual Reset

1.26 in (32 mm)

0.551 in (14 mm)

Trip Free

1.563 in (39.7 mm)

CSA; CUL; UL; VDE

1

60 °C (140 °F)

3120-N311-P7T1-W01D-20A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

20 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

2.22 in (56.4 mm)

0.984 in (25 mm)

Corrosion Resistant; IP00; IP40

Trip Free

1.299 in (33 mm)

CCC; CSA; KC; UL; VDE

1

60 °C (140 °F)

3120-N324-P7T1-W19DG3-20A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

20 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

Corrosion Resistant; IP00; IP40

Manual On/Off

CCC; CE; CSA; CQC; KTL; UKCA; UL; VDE

2

60 °C (140 °F)

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.