Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Actuator Type | Packing Method | Body Length/Diameter | Body Width | Environmental Characteristics | JESD-609 Code | Dimensions | Circuit Function | Body Height | Reference Standard | No. of Poles | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
480 V |
150 V |
20 A |
Stud |
-40 °C (-40 °F) |
10 kA |
Handle |
1.85 in (47 mm) |
0.75 in (19.05 mm) |
Series Trip |
2.5 in (63.5 mm) |
UL |
1 |
85 °C (185 °F) |
|||||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
80 V |
20 A |
Stud |
-40 °C (-40 °F) |
10 kA |
Handle |
2.5 in (63.5 mm) |
0.755 in (19.18 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.85 in (47 mm) |
CSA; TUV; UL |
1 |
85 °C (185 °F) |
|||||||||||
|
Sensata Technologies |
Magnetic Circuit Breaker |
Panel Mount |
80 V |
20 A |
Quick Connect |
-40 °C (-40 °F) |
7.5 kA |
Toggle |
2 in (50.8 mm) |
0.75 in (19.05 mm) |
Corrosion/Moisture Resistant |
Trip Free |
1.687 in (42.85 mm) |
CCC; VDE |
1 |
85 °C (185 °F) |
||||||||||
|
Sensata Technologies |
Magnetic Circuit Breaker |
Panel Mount |
240 V |
80 V |
20 A |
Quick Connect |
-40 °C (-40 °F) |
2 kA |
Toggle |
2 in (50.8 mm) |
0.75 in (19.05 mm) |
Corrosion/Moisture Resistant |
Trip Free |
1.687 in (42.85 mm) |
CCC; VDE |
1 |
85 °C (185 °F) |
|||||||||
|
TE Connectivity |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
20 A |
Quick Connect |
-40 °C (-40 °F) |
5 kA |
2.2 s |
Toggle |
2.25 in (57.15 mm) |
2 in (50.8 mm) |
Fungus Resistant; Moisture Resistant |
2.25 x 2 x 1.64 in (57.15 x 50.8 x 41.66 mm) |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL |
3 |
85 °C (185 °F) |
Standard |
|||||||
TE Connectivity |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
20 A |
Quick Connect |
2.2 s |
Toggle |
Series Trip |
3 |
||||||||||||||||||
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
250 V |
50 V |
20 A |
Quick Connect |
-20 °C (-4 °F) |
2 kA |
Rated breaking capacity at 50 VDC: 2500 A |
Push To Reset |
1.142 in (29 mm) |
0.571 in (14.5 mm) |
Corrosion/Moisture Resistant; IP00; IP40 |
Trip Free |
1.831 in (46.5 mm) |
CQC; CSA; UL; VDE |
1 |
60 °C (140 °F) |
|||||||||
Altech |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
20 A |
Snap On |
-20 °C (-4 °F) |
5 kA |
Toggle Handle |
Bulk |
3.366 in (85.5 mm) |
2.067 in (52.5 mm) |
IP20 |
Trip |
2.362 in (60 mm) |
CE, CUL, UL |
3 |
60 °C (140 °F) |
||||||||||
|
Siemens |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
690 V |
20 A |
Snap On |
-20 °C (-4 °F) |
2 kA |
Interrupting current max at 450 VDC: 10000 A |
Handle |
3.819 in (97 mm) |
1.772 in (45 mm) |
IP20 |
3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm) |
Trip |
3.815 in (96.9 mm) |
ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE |
3 |
60 °C (140 °F) |
Instantaneous |
|||||||
|
Schurter Ag |
Thermal Circuit Breaker |
Panel Mount |
277 V |
28 V |
20 A |
Quick Connect |
-5 °C (23 °F) |
1 kA |
Reset Type |
Bulk |
1.22 in (31 mm) |
0.453 in (11.5 mm) |
IP40 |
Trip Free |
1.772 in (45 mm) |
CCC; CSA; GB; IEC; UL; VDE |
1 |
60 °C (140 °F) |
||||||||
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
115 V |
28 V |
20 A |
Screw |
-55 °C (-67 °F) |
2.5 kA |
Rated breaking capacity at 28 VDC: 6000 A |
Push-Pull |
0.768 in (19.5 mm) |
0.559 in (14.2 mm) |
IP40; IP00 |
Tease-Free And Trip-Free |
1.22 in (31 mm) |
1 |
125 °C (257 °F) |
||||||||||
|
Siemens |
Thermal Circuit Breaker |
DIN Rail Mount |
400 V |
125 V |
20 A |
Screw And Snap On |
14 kA |
Handle |
3.543 in (90 mm) |
2.126 in (54 mm) |
IP20; IP40 |
3.543 x 2.126 x 2.992 in (90 x 54 x 76 mm) |
Trip |
2.992 in (76 mm) |
3 |
|||||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
20 A |
Quick Connect |
-40 °C (-40 °F) |
5 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Handle |
2 in (50.8 mm) |
0.755 in (19.18 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL |
1 |
85 °C (185 °F) |
|||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
20 A |
Quick Connect |
-40 °C (-40 °F) |
5 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Handle |
2 in (50.8 mm) |
0.755 in (19.18 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL |
1 |
85 °C (185 °F) |
|||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
80 V |
20 A |
Screw |
-40 °C (-40 °F) |
3 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Rocker |
2.156 in (54.76 mm) |
1.515 in (38.48 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL; VDE |
2 |
85 °C (185 °F) |
|||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
410 V |
20 A |
Screw |
-40 °C (-40 °F) |
10 kA |
Handle |
3.672 in (93.26 mm) |
1.515 in (38.48 mm) |
Corrosion/Moisture Resistant |
Series Trip |
2.264 in (57.51 mm) |
UL |
2 |
85 °C (185 °F) |
||||||||||
|
Eaton Corporation |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
20 A |
Snap On |
-40 °C (-40 °F) |
15 kA |
Toggle |
3.15 in (80 mm) |
2.091 in (53.1 mm) |
2.362 in (60 mm) |
CCC; CSA; UL; VDE |
3 |
75 °C (167 °F) |
Short |
|||||||||||
|
Eaton Corporation |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
60 V |
20 A |
Snap On |
-25 °C (-13 °F) |
15 kA |
Manual On/Off |
4.134 in (105 mm) |
2.091 in (53.1 mm) |
IP20; IP40 |
Trip |
2.972 in (75.5 mm) |
CSA; EN; IEC; UL |
3 |
75 °C (167 °F) |
|||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
240 V |
20 A |
Screw |
-40 °C (-40 °F) |
2 kA |
Sealed Toggle |
1.375 in (34.93 mm) |
1.3 in (33.02 mm) |
Moisture Resistant; IP68; |
Series Trip |
2.158 in (54.81 mm) |
2 |
85 °C (185 °F) |
||||||||||||
Eaton Corporation |
Thermal Circuit Breaker |
Panel Mount-Threaded |
120 V |
28 V |
20 A |
Screw |
500 A |
Standard: MIL-C-5809, rated breaking capacity at 28 VDC: 2000 A |
0.78 in (19.81 mm) |
0.593 in (15.06 mm) |
0.78 x 0.593 x 1.251 in (19.81 x 15.06 x 31.78 mm) |
1.251 in (31.78 mm) |
MS |
1 |
|||||||||||||
|
Idec |
Magnetic Circuit Breaker |
DIN Rail And Panel Mount |
250 V |
65 V |
20 A |
Snap On |
-10 °C (14 °F) |
2.5 kA |
Toggle |
3.102 in (78.8 mm) |
0.689 in (17.5 mm) |
Manual On/Off |
2.598 in (66 mm) |
CCC; CE; CSA; PSE; TUV; UL |
1 |
60 °C (140 °F) |
||||||||||
|
Idec |
Magnetic Circuit Breaker |
DIN Rail Mount |
250 V |
65 V |
20 A |
Snap On |
-10 °C (14 °F) |
2.5 kA |
Toggle |
2.811 in (71.4 mm) |
0.689 in (17.5 mm) |
IP20 |
Series Trip |
2.598 in (66 mm) |
CCC; CE; CSA; PSE; TUV; UL |
1 |
60 °C (140 °F) |
|||||||||
Abb |
Thermal Circuit Breaker |
DIN Rail Mount |
230 V |
20 A |
Snap On |
-25 °C (-13 °F) |
10 kA |
Manual On/Off |
2.795 in (71 mm) |
0.689 in (17.5 mm) |
IP20 |
2.795 x 0.689 x 3.622 in (71 x 17.5 x 92 mm) |
3.622 in (92 mm) |
CCC; CSA; IEC; UL; VDE |
1 |
55 °C (131 °F) |
|||||||||||
|
Siemens |
Thermal Circuit Breaker |
DIN Rail Mount |
400 V |
20 A |
Snap On |
-25 °C (-13 °F) |
5 kA |
3.535 in (89.8 mm) |
0.693 in (17.6 mm) |
IP20; Sealed |
3.535 x 0.693 x 3.008 in (89.8 x 17.6 x 76.4 mm) |
Trip |
3.008 in (76.4 mm) |
CCC; CE; IMQ; RCM; UL; VDE |
1 |
55 °C (131 °F) |
||||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
20 A |
Screw |
-40 °C (-40 °F) |
5 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Handle |
2 in (50.8 mm) |
0.755 in (19.18 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL |
1 |
85 °C (185 °F) |
|||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
80 V |
20 A |
Screw |
-40 °C (-40 °F) |
5 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Handle |
2 in (50.8 mm) |
0.755 in (19.18 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL |
1 |
85 °C (185 °F) |
||||||||
|
Sensata Technologies |
Magnetic Circuit Breaker |
Panel Mount |
240 V |
20 A |
Screw |
5 kA |
Toggle Handle |
2.49 in (63.24 mm) |
1.515 in (38.48 mm) |
Corrosion/Moisture Resistant |
Trip Free |
1.859 in (47.22 mm) |
CCC; VDE |
2 |
||||||||||||
Eaton Corporation |
Thermal Circuit Breaker |
Panel Mount-Threaded |
120 V |
28 V |
20 A |
Screw |
500 A |
Standard: MIL-C-5809, rated breaking capacity at 28 VDC: 2000 A |
0.78 in (19.81 mm) |
0.593 in (15.06 mm) |
0.78 x 0.593 x 1.251 in (19.81 x 15.06 x 31.78 mm) |
1.251 in (31.78 mm) |
MS |
1 |
|||||||||||||
|
Idec |
Magnetic Circuit Breaker |
Panel Mount |
250 V |
20 A |
Stud |
-40 °C (-40 °F) |
1 kA |
Lever |
2.48 in (63 mm) |
2.256 in (57.3 mm) |
Series Trip |
1.87 in (47.5 mm) |
CCC; CE; CUL; PSE; UL; VDE |
3 |
85 °C (185 °F) |
|||||||||||
|
Carling Technologies |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
20 A |
Quick Connect |
-10 °C (14 °F) |
1 kA |
Rated breaking capacity at 32 VDC: 2500 A |
Push To Reset |
1.154 in (29.3 mm) |
0.551 in (14 mm) |
Manual On/Off |
1.78 in (45.2 mm) |
1 |
60 °C (140 °F) |
||||||||||
|
Schneider Electric Sa |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
440 V |
125 V |
20 A |
Snap On |
-30 °C (-22 °F) |
5 kA |
Toggle |
Bulk |
3.189 in (81 mm) |
1.417 in (36 mm) |
IP20; IP40 |
Trip |
2.874 in (73 mm) |
CCC; CSA; IEC; UL |
2 |
70 °C (158 °F) |
||||||||
|
Eaton Corporation |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
277 V |
20 A |
Snap On |
10 kA |
Toggle |
Manual On/Off |
1 |
|||||||||||||||||
|
Eaton Corporation |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
277 V |
20 A |
Snap On |
10 kA |
Toggle |
Manual On/Off |
2 |
|||||||||||||||||
Eaton Corporation |
Thermal Magnetic Circuit Breaker |
Panel Mount |
240 V |
20 A |
Screw |
10 kA |
Toggle Handle |
Bulk |
Trip |
CSA; UL |
2 |
||||||||||||||||
|
Eaton Corporation |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
277 V |
20 A |
Snap On |
10 kA |
Toggle |
Manual On/Off |
2 |
|||||||||||||||||
|
Eaton Corporation |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
277 V |
60 V |
20 A |
Snap On |
-25 °C (-13 °F) |
14 kA |
Toggle Handle |
4.134 in (105 mm) |
2.091 in (53.1 mm) |
IP20; IP40 |
Trip Free |
1.772 in (45 mm) |
CE; CSA; EN; IEC; UL |
3 |
75 °C (167 °F) |
|||||||||
|
Eaton Corporation |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
96 V |
20 A |
Snap On |
-40 °C (-40 °F) |
5 kA |
Toggle |
3.15 in (80 mm) |
1.394 in (35.4 mm) |
IP20 |
Trip Free |
2.362 in (60 mm) |
CSA; UL |
2 |
167 °C (332.6 °F) |
|||||||||
Eaton Corporation |
Magnetic Circuit Breaker |
Panel Mount |
20 A |
Quick Connect |
Push Button |
0.63 in (16 mm) |
Trip |
1.409 in (35.8 mm) |
CSA, UL |
||||||||||||||||||
Eaton Corporation |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
120 V |
20 A |
Snap On |
10 kA |
Toggle |
Trip |
CSA; UL |
1 |
40 °C (104 °F) |
||||||||||||||||
Eaton Corporation |
Thermal Circuit Breaker |
Panel Mount |
12 V |
20 A |
Stud |
-23 °C (-9.4 °F) |
Automatic Reset |
1.272 in (32.3 mm) |
0.831 in (21.1 mm) |
Water Resistant |
0.618 in (15.7 mm) |
SAE |
1 |
65 °C (149 °F) |
|||||||||||||
Eaton Corporation |
Thermal Circuit Breaker |
Panel Mount |
14 V |
20 A |
Tab/Blade |
-40 °C (-40 °F) |
300 A |
Push To Reset |
1.15 in (29.21 mm) |
0.36 in (9.14 mm) |
Manual Reset/Off |
0.92 in (23.37 mm) |
SAE |
1 |
85 °C (185 °F) |
||||||||||||
Eaton Corporation |
Thermal Circuit Breaker |
Panel Mount |
32 V |
20 A |
Stud |
-40 °C (-40 °F) |
2.5 kA |
Push Button |
2.194 in (55.73 mm) |
1.457 in (37 mm) |
Fluid Resistant, IP66 |
Manual On/Off |
0.728 in (18.5 mm) |
UL |
2 |
85 °C (185 °F) |
|||||||||||
|
Eaton Corporation |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
20 A |
Screw And Snap On |
-40 °C (-40 °F) |
10 kA |
Handle |
Bulk |
3.15 in (80 mm) |
2.126 in (54 mm) |
IP20 |
Trip |
2.858 in (72.6 mm) |
CE; CSA; EN; IEC; UL |
3 |
75 °C (167 °F) |
|||||||||
Eaton Corporation |
Thermal Magnetic Circuit Breaker |
Panel Mount |
240 V |
20 A |
Screw |
10 kA |
Toggle Handle |
Bulk |
Trip |
CSA; UL |
3 |
||||||||||||||||
Eaton Corporation |
Thermal Magnetic Circuit Breaker |
Panel Mount |
240 V |
240 V |
20 A |
10 kA |
Toggle |
3 in (76.2 mm) |
0.75 in (19.05 mm) |
Trip |
3 in (76.2 mm) |
UL |
1 |
||||||||||||||
|
Eaton Corporation |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
96 V |
20 A |
Snap On |
-40 °C (-40 °F) |
15 kA |
Toggle |
3.15 in (80 mm) |
1.394 in (35.4 mm) |
IP20 |
Manual On/Off |
2.362 in (60 mm) |
CCC; CE; CSA; IEC; UL; VDE |
2 |
75 °C (167 °F) |
Short |
||||||||
|
Eaton Corporation |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
277 V |
20 A |
Snap On |
10 kA |
Toggle |
Manual On/Off |
2 |
|||||||||||||||||
Texas Instruments |
Thermal Circuit Breaker |
Panel Mount |
120 V |
28 V |
20 A |
Screw |
2 kA |
3TC2 |
Rated breaking capacity at 28 VDC: 6000 A |
Push-Pull |
1.094 in (27.79 mm) |
0.781 in (19.84 mm) |
Corrosion Resistant |
1.094 x 0.781 x 1.03 in (27.79 x 19.84 x 26.16 mm) |
1.03 in (26.16 mm) |
A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.
Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.