Screw Circuit Breaker 304

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

MS3320-7-1/2V

Eaton Corporation

Thermal Circuit Breaker

Panel Mount

120 V

28 V

7.5 A

Screw

-55 °C (-67 °F)

3.5 kA

Standard: MIL-C-5809, rated breaking capacity at 28 VDC: 6000 A

Push Button

0.781 in (19.84 mm)

0.593 in (15.06 mm)

Corrosion Resistant; Moisture Resistant

0.781 x 0.593 x 1.03 in (19.84 x 15.06 x 26.16 mm)

Trip

1.03 in (26.16 mm)

1

121 °C (249.8 °F)

W31-X2M1G-25

TE Connectivity

Thermal Circuit Breaker

Panel Mount

240 V

50 V

25 A

Screw

1 kA

6 s

Toggle

1.384 in (35.15 mm)

0.69 in (17.53 mm)

Corrosion/Environment/Moisture Resistant

Series Trip

1.6 in (40.64 mm)

CSA; UL

1

MS3320-10V

Eaton Corporation

Thermal Circuit Breaker

Panel Mount

120 V

28 V

10 A

Screw

-55 °C (-67 °F)

3.5 kA

Standard: MIL-C-5809, rated breaking capacity at 28 VDC: 6000 A

Push Button

0.781 in (19.84 mm)

0.593 in (15.06 mm)

Corrosion Resistant; Moisture Resistant

0.781 x 0.593 x 1.03 in (19.84 x 15.06 x 26.16 mm)

Trip

1.03 in (26.16 mm)

1

121 °C (249.8 °F)

184040F-011

Eaton Corporation

Thermal Circuit Breaker

Panel Mount

30 V

40 A

Screw

-32 °C (-25.6 °F)

Lever

2.89 in (73.41 mm)

1.9 in (48.26 mm)

Trip

1.44 in (36.58 mm)

SAE; UL

1

82 °C (179.6 °F)

AC1-B0-14-620-343-D

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

80 V

20 A

Screw

-40 °C (-40 °F)

3 kA

Standards: MIL-PRF-55629, MIL-STD-202

Rocker

2.156 in (54.76 mm)

0.745 in (18.92 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL; VDE

1

85 °C (185 °F)

3VA2163-5HL36-0AA0

Siemens

Thermal Circuit Breaker

Panel Mount

690 V

63 A

Screw

-40 °C (-40 °F)

55 kA

Toggle

7.1 in (180.34 mm)

4.1 in (104.14 mm)

IP40

7.1 x 4.1 x 3.4 in (180.34 x 104.14 x 86.36 mm)

Trip

3.4 in (86.36 mm)

3

70 °C (158 °F)

413-K14-LN2-50A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

28 V

50 A

Screw

-55 °C (-67 °F)

6 kA

Push-Pull

1.26 in (32 mm)

0.748 in (19 mm)

Corrosion/Moisture Resistant; IP00; IP40

Tease-Free And Trip-Free

1.929 in (49 mm)

CSA; UL

1

75 °C (167 °F)

413-K14-N2-70A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

28 V

70 A

Screw

-55 °C (-67 °F)

6 kA

Push-Pull

1.26 in (32 mm)

0.748 in (19 mm)

Corrosion/Moisture Resistant; IP00; IP40

Tease-Free And Trip-Free

1.929 in (49 mm)

CSA; UL

1

75 °C (167 °F)

AM1-B0-14-615-901-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

80 V

15 A

Screw

-40 °C (-40 °F)

7.5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Toggle

2 in (50.8 mm)

0.74 in (18.8 mm)

Corrosion/Moisture Resistant

Series Trip

1.817 in (46.15 mm)

CSA; UL

1

85 °C (185 °F)

MS3320-7.5

Sensata Technologies

Thermal Circuit Breaker

Panel Mount-Threaded

7.5 A

Screw

MS3320

Push-Pull

AM1-B0-14-610-901-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

80 V

10 A

Screw

-40 °C (-40 °F)

7.5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Toggle

2 in (50.8 mm)

0.74 in (18.8 mm)

Corrosion/Moisture Resistant

Series Trip

1.817 in (46.15 mm)

CSA; UL

1

85 °C (185 °F)

AP17-1-64-502

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

240 V

5 A

Screw

-40 °C (-40 °F)

1 kA

Toggle

1.562 in (39.67 mm)

1.281 in (32.53 mm)

Corrosion Resistant; Sealed

Series Trip

1.78 in (45.21 mm)

2

100 °C (212 °F)

CA1-B2-34-450-A21-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

480 V

150 V

5 A

Screw

-40 °C (-40 °F)

10 kA

Handle

1.85 in (47 mm)

0.75 in (19.05 mm)

Series Trip

2.5 in (63.5 mm)

UL

1

85 °C (185 °F)

MS1-B-10-430-2-1CB-A-A

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

50 V

3 A

Screw

-40 °C (-40 °F)

3 kA

Standards: MIL-PRF-55629, MIL-STD-202

Toggle

1.375 in (34.93 mm)

0.656 in (16.66 mm)

IP68

Series Trip

1.634 in (41.5 mm)

1

85 °C (185 °F)

2TC2-71/2

Texas Instruments

Thermal Circuit Breaker

Panel Mount

120 V

28 V

7.5 A

Screw

2.5 kA

2TC2

Push-Pull

0.781 in (19.84 mm)

0.593 in (15.06 mm)

Corrosion Resistant

0.781 x 0.593 x 1.03 in (19.84 x 15.06 x 26.16 mm)

1.03 in (26.16 mm)

184040F-031

Eaton Corporation

Thermal Circuit Breaker

Panel Mount

30 V

40 A

Screw

-32 °C (-25.6 °F)

Lever

2.89 in (73.41 mm)

1.9 in (48.26 mm)

Trip

1.44 in (36.58 mm)

SAE; UL

1

82 °C (179.6 °F)

184040F-041

Eaton Corporation

Thermal Circuit Breaker

Panel Mount

30 V

40 A

Screw

-32 °C (-25.6 °F)

Lever

2.89 in (73.41 mm)

1.9 in (48.26 mm)

Trip

1.44 in (36.58 mm)

SAE; UL

1

82 °C (179.6 °F)

413-K14-N2-60A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

28 V

60 A

Screw

-55 °C (-67 °F)

6 kA

Push-Pull

1.26 in (32 mm)

0.748 in (19 mm)

Corrosion/Moisture Resistant; IP00; IP40

Tease-Free And Trip-Free

1.929 in (49 mm)

CSA; UL

1

75 °C (167 °F)

4411.0067

Schurter Ag

Thermal Circuit Breaker

Panel Mount

277 V

28 V

30 A

Screw

-5 °C (23 °F)

1 kA

Reset Type

Bulk

1.22 in (31 mm)

0.453 in (11.5 mm)

Trip

1.772 in (45 mm)

CCC; CSA; UL; VDE

1

60 °C (140 °F)

5SY5206-7

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

500 V

6 A

Screw

10 kA

Handle

3.543 in (90 mm)

1.417 in (36 mm)

IP20

3.543 x 1.417 x 2.992 in (90 x 36 x 76 mm)

Trip

2.992 in (76 mm)

2

C13-B9-46-610-546-R

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

10 A

Screw

-40 °C (-40 °F)

5 kA

Rocker

2.5 in (63.5 mm)

2.265 in (57.53 mm)

Corrosion/Moisture Resistant

Series Trip

1.85 in (47 mm)

CSA; TUV; UL

3

85 °C (185 °F)

CM1-B0-22-420-201-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

2 A

Screw

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Toggle

2.5 in (63.5 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.85 in (47 mm)

CSA; UL

1

85 °C (185 °F)

MS14154-10L

Sensata Technologies

Thermal Circuit Breaker

Panel Mount-Threaded

120 V

10 A

Screw

2 kA

Push-Pull

1.84 in (46.73 mm)

0.781 in (19.84 mm)

Corrosion Resistant; Moisture Resistant

1.84 x 0.781 x 1.384 in (46.73 x 19.84 x 35.15 mm)

Trip Free

1.436 in (36.47 mm)

1

AA1-B0-26-440-2B1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

4 A

Screw

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

AB3-B0-26-475-3B1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

7.5 A

Screw

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2.265 in (57.53 mm)

2 in (50.8 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

3

85 °C (185 °F)

0903037

Phoenix Contact

Magnetic Circuit Breaker

DIN Rail Mount

8 A

Screw

0 °C (32 °F)

Bulk

3.15 in (80 mm)

0.492 in (12.5 mm)

IP20

3.268 in (83 mm)

CE, UL

50 °C (122 °F)

0916604

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

240 V

28 V

1 A

Screw

-30 °C (-22 °F)

3.524 in (89.5 mm)

0.484 in (12.3 mm)

IP20; IP40

3.524 x 0.484 x 3.366 in (89.5 x 12.3 x 85.5 mm)

3.366 in (85.5 mm)

CSA; CUL; EN; UL; VDE

1

60 °C (140 °F)

C13-B9-46-610-543-R

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

10 A

Screw

-40 °C (-40 °F)

5 kA

Rocker

2.5 in (63.5 mm)

2.265 in (57.53 mm)

Corrosion/Moisture Resistant

Series Trip

1.85 in (47 mm)

CSA; TUV; UL

3

85 °C (185 °F)

GV3P65

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

Panel Mount

690 V

65 A

Screw

-20 °C (-4 °F)

6 kA

Reference standard: UL

Rotary Handle

Bulk

5.197 in (132 mm)

2.165 in (55 mm)

IK09; IP20

Trip

5.354 in (136 mm)

ATEX; ABS; BV; CCC; CSA; DNV-GL; EAC; EN; IEC; LROS; UKCA

3

60 °C (140 °F)

MS3320-15L

Eaton Corporation

Thermal Circuit Breaker

Panel Mount

120 V

28 V

15 A

Screw

-55 °C (-67 °F)

3.5 kA

Standard: MIL-C-5809, rated breaking capacity at 28 VDC: 6000 A

Push Button

0.781 in (19.84 mm)

0.593 in (15.06 mm)

Corrosion Resistant; Moisture Resistant

0.781 x 0.593 x 1.03 in (19.84 x 15.06 x 26.16 mm)

Trip

1.03 in (26.16 mm)

1

121 °C (249.8 °F)

3VA5340-6EF31-0AA0

Siemens

Thermal Circuit Breaker

Panel Mount

600 V

500 V

400 A

Screw

-25 °C (-13 °F)

65 kA

Toggle

9.8 in (248.92 mm)

5.4 in (137.16 mm)

IP40

9.8 x 5.4 x 4.3 in (248.92 x 137.16 x 109.22 mm)

Trip

4.3 in (109.22 mm)

3

70 °C (158 °F)

3VA5440-1MU31-0AA0

Siemens

Thermal Circuit Breaker

Panel Mount

600 V

400 A

Screw

-25 °C (-13 °F)

150 kA

Toggle

9.8 in (248.92 mm)

5.4 in (137.16 mm)

IP40

9.8 x 5.4 x 4.3 in (248.92 x 137.16 x 109.22 mm)

Trip

4.3 in (109.22 mm)

3

70 °C (158 °F)

PDLA-150

Sensata Technologies

Thermal Circuit Breaker

Panel Mount

30 V

150 A

Screw

Push Button

3.125 in (79.38 mm)

1.859 in (47.22 mm)

Trip

1.078 in (27.38 mm)

CCC

PDLA-150-I

Sensata Technologies

Thermal Circuit Breaker

Panel Mount

30 V

150 A

Screw

Push Button

3.125 in (79.38 mm)

1.859 in (47.22 mm)

Trip

1.078 in (27.38 mm)

CCC

0903028

Phoenix Contact

Magnetic Circuit Breaker

DIN Rail Mount

6 A

Screw

0 °C (32 °F)

Bulk

3.15 in (80 mm)

0.492 in (12.5 mm)

IP20

3.268 in (83 mm)

CE, UL

50 °C (122 °F)

483-G411-K1M1-A1S0ZN--10A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

28 V

10 A

Screw

-55 °C (-67 °F)

2.5 kA

Rated breaking capacity at 28 VDC: 6000 A

Push-Pull

0.768 in (19.5 mm)

0.559 in (14.2 mm)

IP40; IP00

0.768 x 0.559 x 1.22 in (19.5 x 14.2 x 31 mm)

Tease-Free And Trip-Free

1.22 in (31 mm)

1

125 °C (257 °F)

5SU1354-6KK16

Siemens

Thermal Circuit Breaker

Panel Mount

240 V

16 A

Screw

-25 °C (-13 °F)

10 kA

3.543 in (90 mm)

1.394 in (35.4 mm)

IP20

Trip

3 in (76.2 mm)

CCC; CE; IMQ; RCM; VDE

2

55 °C (131 °F)

6752-100-50

Sensata Technologies

Thermal Circuit Breaker

Panel Mount

120 V

28 V

50 A

Screw

3.5 kA

1 s

Rated breaking capacity at 28 VDC: 6000 A

Push-Pull

2.189 in (55.6 mm)

0.75 in (19.05 mm)

Corrosion/Moisture Resistant

2.189 x 0.75 x 1.93 in (55.6 x 19.05 x 49.02 mm)

Trip

1.93 in (49.02 mm)

1

AP17-1-61-203

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

240 V

20 A

Screw

-40 °C (-40 °F)

1 kA

Toggle

1.562 in (39.67 mm)

1.281 in (32.53 mm)

Corrosion Resistant; Sealed

Series Trip

1.78 in (45.21 mm)

2

100 °C (212 °F)

CLB-103-27E3N-B-F

Carling Technologies

Thermal Circuit Breaker

Panel Mount

250 V

32 V

10 A

Screw

-10 °C (14 °F)

300 A

Rated breaking capacity at 32 VDC: 2500 A

Push To Reset

1.378 in (35 mm)

0.571 in (14.5 mm)

Fire Resistant

Series Trip

1.693 in (43 mm)

CE; TUV; UL

1

60 °C (140 °F)

CLB-103-27E3N-W-F

Carling Technologies

Thermal Circuit Breaker

Panel Mount

250 V

32 V

10 A

Screw

-10 °C (14 °F)

300 A

Rated breaking capacity at 32 VDC: 2500 A

Push To Reset

1.378 in (35 mm)

0.571 in (14.5 mm)

Fire Resistant

Series Trip

1.693 in (43 mm)

CE; TUV; UL

1

60 °C (140 °F)

MS25361-50

Sensata Technologies

Thermal Circuit Breaker

Panel Mount

120 V

28 V

50 A

Screw

3.5 kA

Rated breaking capacity at 28 VDC: 6000 A

Push-Pull

2.189 in (55.6 mm)

0.75 in (19.05 mm)

Corrosion Resistant; Moisture Resistant

2.56 in (65.02 mm)

MIL-C-5809

1

MS26574-2A

Eaton Corporation

Thermal Circuit Breaker

Panel Mount-Threaded

120 V

28 V

2 A

Screw

800 A

Standard: MIL-C-5809

0.78 in (19.81 mm)

0.593 in (15.06 mm)

0.78 x 0.593 x 1.251 in (19.81 x 15.06 x 31.78 mm)

1.251 in (31.78 mm)

MS

1

W67-X2T52-50

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

65 V

50 A

Screw

2.2 s

Toggle

Series Trip

1

3VA5110-6EC41-0AA0

Siemens

Thermal Circuit Breaker

Panel Mount

690 V

600 V

100 A

Screw

-25 °C (-13 °F)

65 kA

Toggle

5.5 in (139.7 mm)

4 in (101.6 mm)

IP40

5.5 x 4 x 3 in (139.7 x 101.6 x 76.2 mm)

Trip

3 in (76.2 mm)

4

70 °C (158 °F)

3VA5110-6GC41-0AA0

Siemens

Thermal Circuit Breaker

Panel Mount

690 V

600 V

100 A

Screw

-25 °C (-13 °F)

65 kA

Toggle

5.5 in (139.7 mm)

4 in (101.6 mm)

IP40

5.5 x 4 x 3 in (139.7 x 101.6 x 76.2 mm)

Trip

3 in (76.2 mm)

4

70 °C (158 °F)

3VA5120-6ED21-0AA0

Siemens

Thermal Circuit Breaker

Panel Mount

600 V

250 V

20 A

Screw

-25 °C (-13 °F)

65 kA

Toggle

5.5 in (139.7 mm)

2 in (50.8 mm)

IP40

5.5 x 2 x 3 in (139.7 x 50.8 x 76.2 mm)

Trip

3 in (76.2 mm)

2

70 °C (158 °F)

3VA5210-6EC41-0AA0

Siemens

Thermal Circuit Breaker

Panel Mount

690 V

1 KV

100 A

Screw

-25 °C (-13 °F)

65 kA

Toggle

7.3 in (185.42 mm)

5.5 in (139.7 mm)

IP40

7.3 x 5.5 x 3.3 in (185.42 x 139.7 x 83.82 mm)

Trip

3.3 in (83.82 mm)

4

70 °C (158 °F)

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.