Screw Circuit Breaker 304

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

3VA5210-6GC41-0AA0

Siemens

Thermal Circuit Breaker

Panel Mount

690 V

1 KV

100 A

Screw

-25 °C (-13 °F)

65 kA

Toggle

7.3 in (185.42 mm)

5.5 in (139.7 mm)

IP40

7.3 x 5.5 x 3.3 in (185.42 x 139.7 x 83.82 mm)

Trip

3.3 in (83.82 mm)

4

70 °C (158 °F)

482-G111-K1M1-A1S0-30A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

72 V

30 A

Screw

-55 °C (-67 °F)

5 kA

Push-Pull

1.22 in (31 mm)

0.709 in (18 mm)

Corrosion/Moisture Resistant; IP00; IP40

Trip Free

1.969 in (50 mm)

CSA; CUL; UL

1

75 °C (167 °F)

483-G411-K1M1-A1S0ZN--5A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

28 V

5 A

Screw

-55 °C (-67 °F)

2 kA

Rated breaking capacity at 28 VDC: 6000 A

Push-Pull

0.768 in (19.5 mm)

0.559 in (14.2 mm)

IP40; IP00

Tease-Free And Trip-Free

1.22 in (31 mm)

1

125 °C (257 °F)

AA1-B0-34-450-3B1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

80 V

5 A

Screw

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

BA1-B2-46-625-52A-K3

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

25 A

Screw

-40 °C (-40 °F)

3 kA

Handle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.73 in (43.94 mm)

UL; TUV

1

85 °C (185 °F)

BA2-B0-46-625-521-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

25 A

Screw

-40 °C (-40 °F)

5 kA

Handle

2 in (50.8 mm)

1.515 in (38.48 mm)

Corrosion/Moisture Resistant

Series Trip

1.73 in (43.94 mm)

CSA; UL

2

85 °C (185 °F)

BA2-B2-36-625-525-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

80 V

25 A

Screw

-40 °C (-40 °F)

5 kA

Handle

2 in (50.8 mm)

1.515 in (38.48 mm)

Corrosion/Moisture Resistant

Series Trip

1.73 in (43.94 mm)

CSA; UL

2

85 °C (185 °F)

CX2-B0-14-620-22A-13G

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

500 V

20 A

Screw

-40 °C (-40 °F)

10 kA

Handle

3.672 in (93.26 mm)

1.515 in (38.48 mm)

Corrosion/Moisture Resistant

Series Trip

2.264 in (57.51 mm)

UL

2

85 °C (185 °F)

LELH11-1-62-30.0-01-V

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

125 V

30 A

Screw

5 kA

Toggle Handle

2.49 in (63.24 mm)

1.515 in (38.48 mm)

Corrosion/Moisture Resistant

Trip Free

1.859 in (47.22 mm)

CCC; VDE

2

MS26574-20L

Eaton Corporation

Thermal Circuit Breaker

Panel Mount-Threaded

120 V

28 V

20 A

Screw

500 A

Standard: MIL-C-5809, rated breaking capacity at 28 VDC: 2000 A

0.78 in (19.81 mm)

0.593 in (15.06 mm)

0.78 x 0.593 x 1.251 in (19.81 x 15.06 x 31.78 mm)

1.251 in (31.78 mm)

MS

1

W58-XC4C12A-3

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

50 V

3 A

Screw

2 kA

10 s

Push To Reset

1.375 in (34.93 mm)

0.66 in (16.76 mm)

1.375 x 0.66 x 1.375 in (34.93 x 16.76 x 34.93 mm)

Series Trip

1.375 in (34.93 mm)

CSA; UL

1

0903029

Phoenix Contact

Magnetic Circuit Breaker

DIN Rail Mount

8 A

Screw

0 °C (32 °F)

Bulk

3.15 in (80 mm)

0.492 in (12.5 mm)

IP20

3.268 in (83 mm)

CE, UL

50 °C (122 °F)

412-K14-N2-7.5A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

28 V

7.5 A

Screw

-55 °C (-67 °F)

6 kA

Push-Pull

1.142 in (29 mm)

0.571 in (14.5 mm)

Corrosion/Moisture Resistant; IP00; IP40

Trip Free

1.811 in (46 mm)

CSA; UL

1

75 °C (167 °F)

413-K14-LN2-60A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

28 V

60 A

Screw

-55 °C (-67 °F)

6 kA

Push-Pull

1.26 in (32 mm)

0.748 in (19 mm)

Corrosion/Moisture Resistant; IP00; IP40

Tease-Free And Trip-Free

1.929 in (49 mm)

CSA; UL

1

75 °C (167 °F)

413-K54-N2-70A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

28 V

70 A

Screw

-55 °C (-67 °F)

6 kA

Push-Pull

1.26 in (32 mm)

0.748 in (19 mm)

Corrosion/Moisture Resistant; IP00; IP40

Trip Free

1.929 in (49 mm)

CSA; UL

1

75 °C (167 °F)

4130-G211-K4M1-50A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

50 A

Screw

-30 °C (-22 °F)

800 A

Push To Reset

1.26 in (32 mm)

0.709 in (18 mm)

Corrosion Resistant; IP00; IP40

1.26 x 0.709 x 1.969 in (32 x 18 x 50 mm)

Tease-Free And Trip-Free

1.969 in (50 mm)

CBE; CSA; EN; IEC; UL; VDE

1

60 °C (140 °F)

Medium

422142

Legrand

Thermal Magnetic Circuit Breaker

Panel Mount

400 V

320 A

Screw

-25 °C (-13 °F)

36 kA

Toggle Handle

Bulk

10.236 in (260 mm)

7.205 in (183 mm)

Trip

5.669 in (144 mm)

IEC

4

70 °C (158 °F)

423027

Legrand

Thermal Magnetic Circuit Breaker

Panel Mount

400 V

250 A

Screw

-25 °C (-13 °F)

36 kA

Toggle Handle

Bulk

6.496 in (165 mm)

5.512 in (140 mm)

Trip

4.409 in (112 mm)

IEC

4

70 °C (158 °F)

423052

Legrand

Thermal Magnetic Circuit Breaker

Panel Mount

400 V

80 A

Screw

-25 °C (-13 °F)

36 kA

Toggle Handle

Bulk

6.496 in (165 mm)

5.512 in (140 mm)

Trip

4.409 in (112 mm)

IEC

4

70 °C (158 °F)

482-G111-K1M1-A1S1-50A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

28 V

50 A

Screw

-55 °C (-67 °F)

5 kA

Push Button

1.22 in (31 mm)

0.709 in (18 mm)

Corrosion/Moisture Resistant; IP00; IP40

Trip Free

1.89 in (48 mm)

BW; CSA; UL

1

75 °C (167 °F)

482-G111-K1M1-A1S1-5A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

28 V

5 A

Screw

-55 °C (-67 °F)

5 kA

Push Button

1.22 in (31 mm)

0.709 in (18 mm)

Corrosion/Moisture Resistant; IP00; IP40

Trip Free

1.89 in (48 mm)

BW; CSA; UL

1

75 °C (167 °F)

483-G411-K1M1-A1S0Z--5A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

28 V

5 A

Screw

-55 °C (-67 °F)

2 kA

Rated breaking capacity at 28 VDC: 6000 A

Push-Pull

0.768 in (19.5 mm)

0.559 in (14.2 mm)

IP40; IP00

Tease-Free And Trip-Free

1.22 in (31 mm)

1

125 °C (257 °F)

AA2-B0-34-625-9G7-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

80 V

25 A

Screw

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

1.515 in (38.48 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

2

85 °C (185 °F)

AB2-B0-34-625-5D1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

80 V

25 A

Screw

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

1.515 in (38.48 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

2

85 °C (185 °F)

AC2-B0-24-625-431-D

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

25 A

Screw

-40 °C (-40 °F)

1 kA

Standards: MIL-PRF-55629, MIL-STD-202

Rocker

2.156 in (54.76 mm)

1.515 in (38.48 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL; VDE

2

85 °C (185 °F)

AD2-B0-34-625-3B1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

80 V

25 A

Screw

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Rocker

2.156 in (54.76 mm)

1.515 in (38.48 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

2

85 °C (185 °F)

AJ1-B2-16-610-444-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

80 V

10 A

Screw

-40 °C (-40 °F)

7.5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Rocker

2.156 in (54.76 mm)

0.745 in (18.92 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

CELB1-1-52-100.-A1-01-V

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

80 V

100 A

Screw

-40 °C (-40 °F)

5 kA

Toggle

2.49 in (63.24 mm)

0.75 in (19.05 mm)

Corrosion/Moisture Resistant

Series Trip

1.859 in (47.22 mm)

CCC; CSA; TUV; UL

1

85 °C (185 °F)

CJ3-B2-26-625-524-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

25 A

Screw

-40 °C (-40 °F)

5 kA

Rocker

2.5 in (63.5 mm)

2.265 in (57.53 mm)

Corrosion/Moisture Resistant

Series Trip

2.16 in (54.86 mm)

CSA; UL

3

85 °C (185 °F)

CJ3-B2-26-625-524-D

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

25 A

Screw

-40 °C (-40 °F)

5 kA

Rocker

2.5 in (63.5 mm)

2.265 in (57.53 mm)

Corrosion/Moisture Resistant

Series Trip

2.16 in (54.86 mm)

CSA; UL; VDE

3

85 °C (185 °F)

DA2-B0-34-450-121-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

5 A

Screw

-40 °C (-40 °F)

1.5 kA

Toggle Handle

3.612 in (91.75 mm)

1.515 in (38.48 mm)

Moisture Resistant

Series Trip

2.165 in (54.99 mm)

CSA; UL

2

85 °C (185 °F)

FA3-P0-14-870-22B-BT

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

125 V

700 A

Screw

-40 °C (-40 °F)

50 kA

Handle

7.125 in (180.98 mm)

4.5 in (114.3 mm)

Corrosion/Moisture Resistant

Series Trip

2.968 in (75.38 mm)

UL

3

85 °C (185 °F)

LELB1-1-51-10.0-A1-01-V

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

125 V

10 A

Screw

5 kA

Toggle

2.49 in (63.24 mm)

0.75 in (19.05 mm)

Corrosion/Moisture Resistant

Trip Free

1.859 in (47.22 mm)

CCC; VDE

1

LELB1-1-52-10.0-A1-01-V

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

125 V

10 A

Screw

5 kA

Toggle

2.49 in (63.24 mm)

0.75 in (19.05 mm)

Corrosion/Moisture Resistant

Trip Free

1.859 in (47.22 mm)

CCC; VDE

1

LELB1-1-53-100.-A1-01-V

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

80 V

100 A

Screw

50 kA

Toggle

2.49 in (63.24 mm)

0.75 in (19.05 mm)

Corrosion/Moisture Resistant

Trip Free

1.859 in (47.22 mm)

CCC; VDE

1

LRD10

Schneider Electric Sa

Thermal Circuit Breaker

Panel Mount

690 V

6 A

Screw

-20 °C (-4 °F)

1.772 in (45 mm)

IP20

Trip

2.756 in (70 mm)

ATEX; BV; CCC; CSA; DNV; EN; GL; GOST; IEC; RINA; UL

60 °C (140 °F)

MF2-B-64-622-2-CC6-B-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

22 A

Screw

-40 °C (-40 °F)

1 kA

Illuminated Rocker

1.375 in (34.93 mm)

1.304 in (33.12 mm)

Chemical/Corrosion/Moisture Resistant

Series Trip

1.53 in (38.86 mm)

UL; CSA

2

85 °C (185 °F)

MS26574-10

Eaton Corporation

Thermal Circuit Breaker

Panel Mount-Threaded

120 V

28 V

10 A

Screw

500 A

Standard: MIL-C-5809, rated breaking capacity at 28 VDC: 2000 A

0.78 in (19.81 mm)

0.593 in (15.06 mm)

0.78 x 0.593 x 1.251 in (19.81 x 15.06 x 31.78 mm)

1.251 in (31.78 mm)

MS

1

MS26574-2

Eaton Corporation

Thermal Circuit Breaker

Panel Mount-Threaded

120 V

28 V

2 A

Screw

800 A

Standard: MIL-C-5809

0.78 in (19.81 mm)

0.593 in (15.06 mm)

0.78 x 0.593 x 1.251 in (19.81 x 15.06 x 31.78 mm)

1.251 in (31.78 mm)

MS

1

0903030

Phoenix Contact

Magnetic Circuit Breaker

DIN Rail Mount

10 A

Screw

0 °C (32 °F)

Bulk

3.15 in (80 mm)

0.492 in (12.5 mm)

IP20

3.268 in (83 mm)

CE, UL

50 °C (122 °F)

0903032

Phoenix Contact

Magnetic Circuit Breaker

DIN Rail Mount

1 A

Screw

0 °C (32 °F)

Bulk

3.15 in (80 mm)

0.492 in (12.5 mm)

IP20

3.268 in (83 mm)

CE, UL

50 °C (122 °F)

0903038

Phoenix Contact

Magnetic Circuit Breaker

DIN Rail Mount

10 A

Screw

0 °C (32 °F)

Bulk

3.15 in (80 mm)

0.492 in (12.5 mm)

IP20

3.268 in (83 mm)

CE, UL

50 °C (122 °F)

3VA6210-5HM31-2AA0

Siemens

Thermal Circuit Breaker

Panel Mount

600 V

100 A

Screw

-25 °C (-13 °F)

35 kA

Toggle

7.8 in (198.12 mm)

4.1 in (104.14 mm)

IP40

7.8 x 4.1 x 3.4 in (198.12 x 104.14 x 86.36 mm)

Trip

3.4 in (86.36 mm)

3

70 °C (158 °F)

413-K14-LN2-45A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

28 V

45 A

Screw

-55 °C (-67 °F)

6 kA

Push-Pull

1.26 in (32 mm)

0.748 in (19 mm)

Corrosion/Moisture Resistant; IP00; IP40

Tease-Free And Trip-Free

1.929 in (49 mm)

CSA; UL

1

75 °C (167 °F)

413-K14-LN2-80A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

28 V

80 A

Screw

-55 °C (-67 °F)

6 kA

Push-Pull

1.26 in (32 mm)

0.748 in (19 mm)

Corrosion/Moisture Resistant; IP00; IP40

Tease-Free And Trip-Free

1.929 in (49 mm)

CSA; UL

1

75 °C (167 °F)

413-K54-N2-60A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

28 V

60 A

Screw

-55 °C (-67 °F)

6 kA

Push-Pull

1.26 in (32 mm)

0.748 in (19 mm)

Corrosion/Moisture Resistant; IP00; IP40

Trip Free

1.929 in (49 mm)

CSA; UL

1

75 °C (167 °F)

422191

Legrand

Thermal Magnetic Circuit Breaker

Panel Mount

400 V

250 A

Screw

-25 °C (-13 °F)

50 kA

Toggle Handle

Bulk

10.236 in (260 mm)

7.205 in (183 mm)

Trip

5.669 in (144 mm)

IEC

4

70 °C (158 °F)

482-G111-K1M1-A1S0-50A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

72 V

50 A

Screw

-55 °C (-67 °F)

5 kA

Push-Pull

1.22 in (31 mm)

0.709 in (18 mm)

Corrosion/Moisture Resistant; IP00; IP40

Trip Free

1.969 in (50 mm)

CSA; CUL; UL

1

75 °C (167 °F)

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.