Circuit Breaker

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

S201-C16

Abb

Thermal Magnetic Circuit Breaker

DIN Rail Mount

250 V

16 A

Snap On

-25 °C (-13 °F)

6 kA

Toggle

IP20; IP40

Trip

CSA; IEC; UL

55 °C (131 °F)

2TC2-5

Texas Instruments

Thermal Circuit Breaker

Panel Mount

120 V

28 V

5 A

Screw

2.5 kA

2TC2

Push-Pull

0.781 in (19.84 mm)

0.593 in (15.06 mm)

Corrosion Resistant

0.781 x 0.593 x 1.03 in (19.84 x 15.06 x 26.16 mm)

1.03 in (26.16 mm)

XT3SU3150AFF000XXX

Abb

Thermal Magnetic Circuit Breaker

DIN Rail Mount

347 V

500 V

150 A

Snap On

10 kA

Manual On/Off

CSA; UL

5.118 in (130 mm)

3 in (76.2 mm)

Trip

2.756 in (70 mm)

3

5SV3346-6

Siemens

Equipment Leakage Circuit Breaker

DIN Rail Mount

400 V

63 A

Snap On

-25 °C (-13 °F)

10 kA

Bulk

3.543 in (90 mm)

2.835 in (72 mm)

IP20

Trip

2.756 in (70 mm)

CCC; CE; CEBEC; EAC; IMQ; OVE; VDE

4

45 °C (113 °F)

W28-XQ1A-1

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

32 V

1 A

Quick Connect

1 kA

4.5 s

Push To Reset

0.625 in (15.88 mm)

0.54 in (13.72 mm)

0.625 x 0.54 x 1.535 in (15.88 x 13.72 x 38.99 mm)

Series Trip

1.535 in (38.99 mm)

CSA; UL; VDE

1

W67-X2Q12-20

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

20 A

Quick Connect

-40 °C (-40 °F)

5 kA

2.2 s

Toggle

2 in (50.8 mm)

0.75 in (19.05 mm)

Fungus Resistant; Moisture Resistant

2 x 0.75 x 1.64 in (50.8 x 19.05 x 41.66 mm)

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

Standard

W67-X2Q1220

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

20 A

Quick Connect

2.2 s

Toggle

Series Trip

1

18642

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

2909906

Phoenix Contact

Thermal Circuit Breaker

S203-C16

Abb

Thermal Magnetic Circuit Breaker

1610-21-30A

E-t-a Elektrotechnische Apparate

AC2-B2-26-610-144-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

10 A

Quick Connect

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Rocker

2.156 in (54.76 mm)

1.515 in (38.48 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

2

85 °C (185 °F)

2CDS251001R0024

Abb

Thermal Magnetic Circuit Breaker

S204M-D32

Abb

Thermal Magnetic Circuit Breaker

MS132-10T

Abb

Thermal Circuit Breaker

DIN Rail Mount

690 V

10 A

Screw

-25 °C (-13 °F)

18 kA

Rotary Handle

Bulk

3.85 in (97.8 mm)

1.772 in (45 mm)

IP10; IP20

Trip Free

3.388 in (86.05 mm)

EN; IEC

3

70 °C (158 °F)

XT1NU3030AFF000XXX

Abb

Thermal Magnetic Circuit Breaker

DIN Rail Mount

347 V

500 V

30 A

Snap On

18 kA

Manual On/Off

CSA; UL

5.118 in (130 mm)

3 in (76.2 mm)

Trip

2.756 in (70 mm)

3

2909909

Phoenix Contact

Thermal Circuit Breaker

M9F52335

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

2CDS252001R0064

Abb

Thermal Magnetic Circuit Breaker

CCP2-2-30CC

Eaton Corporation

Equipment Leakage Circuit Breaker

Panel Mount

600 V

125 V

30 A

200 kA

Toggle Handle

3.1 in (78.74 mm)

1.4 in (35.56 mm)

Manual On/Off

3.9 in (99.06 mm)

UL

2

W58-XB1A4A-20

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

50 V

20 A

Quick Connect

1 kA

6 s

Rated breaking capacity at 50 VDC: 2000 A

Push To Reset

1.375 x 0.66 x 1.375 in (34.93 x 16.76 x 34.93 mm)

Series Trip

1

5SV3346-6KL

Siemens

Equipment Leakage Circuit Breaker

DIN Rail Mount

400 V

63 A

Screw And Snap On

10 kA

Handle

3.543 in (90 mm)

2.835 in (72 mm)

IP20

3.543 x 2.835 x 2.756 in (90 x 72 x 70 mm)

Trip

2.756 in (70 mm)

4

70 °C (158 °F)

W58-XB1A4A-15

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

50 V

15 A

Quick Connect

1 kA

6 s

Push To Reset

1.375 in (34.93 mm)

0.66 in (16.76 mm)

Series Trip

1.375 in (34.93 mm)

1

XT1NU3040AFF000XXX

Abb

Thermal Magnetic Circuit Breaker

DIN Rail Mount

347 V

40 A

Snap On

18 kA

5.118 in (130 mm)

3 in (76.2 mm)

5.118 x 3 x 2.756 in (130 x 76.2 x 70 mm)

Trip

2.756 in (70 mm)

CSA; UL

3

QOB250GFI

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

QOB250H

Schneider Electric Sa

Thermal Circuit Breaker

QOB250VH

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

QOB250VH1021

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

W23-X1A1G-50

TE Connectivity

Thermal Circuit Breaker

Panel Mount

240 V

50 V

50 A

Screw

1 kA

6 s

Push-Pull

1.384 in (35.15 mm)

0.69 in (17.53 mm)

Corrosion/Environment/Moisture Resistant

Series Trip

1.6 in (40.64 mm)

CSA; UL

1

MS3320-15V

Eaton Corporation

Thermal Circuit Breaker

Panel Mount

120 V

28 V

15 A

Screw

-55 °C (-67 °F)

3.5 kA

Standard: MIL-C-5809, rated breaking capacity at 28 VDC: 6000 A

Push Button

0.781 in (19.84 mm)

0.593 in (15.06 mm)

Corrosion Resistant; Moisture Resistant

0.781 x 0.593 x 1.03 in (19.84 x 15.06 x 26.16 mm)

Trip

1.03 in (26.16 mm)

1

121 °C (249.8 °F)

2TC2-21/2

Texas Instruments

Thermal Circuit Breaker

Panel Mount

120 V

28 V

2.5 A

Screw

2.8 kA

2TC2

Push-Pull

0.781 in (19.84 mm)

0.593 in (15.06 mm)

Corrosion Resistant

0.781 x 0.593 x 1.03 in (19.84 x 15.06 x 26.16 mm)

1.03 in (26.16 mm)

W31-X2M1G-10

TE Connectivity

Thermal Circuit Breaker

Panel Mount

240 V

50 V

10 A

Screw

1 kA

6 s

Toggle

1.384 in (35.15 mm)

0.69 in (17.53 mm)

Corrosion/Environment/Moisture Resistant

Series Trip

1.6 in (40.64 mm)

CSA; UL

1

QOB250EPD

Schneider Electric Sa

Thermal Circuit Breaker

236404

Eaton Corporation

Thermal Circuit Breaker

Panel Mount

400 V

40 A

Screw

-25 °C (-13 °F)

10 kA

IP20

Trip

3

75 °C (167 °F)

QOB2501021

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

W28-XQ1A-6

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

32 V

6 A

Quick Connect

1 kA

2.2 s

Push To Reset

0.625 in (15.88 mm)

0.54 in (13.72 mm)

0.625 x 0.54 x 1.535 in (15.88 x 13.72 x 38.99 mm)

Series Trip

1.535 in (38.99 mm)

CSA; UL; VDE

1

S202M-C6

Abb

Thermal Magnetic Circuit Breaker

W92-X112-30

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

30 A

Stud

-40 °C (-40 °F)

5 kA

2.2 s

Toggle

2.5 in (63.5 mm)

1.5 in (38.1 mm)

Moisture Resistant

Series Trip

1.985 in (50.42 mm)

CSA; UL; VDE

2

85 °C (185 °F)

Standard

185120F-011

Eaton Corporation

Thermal Circuit Breaker

Panel Mount

30 V

120 A

Screw

-32 °C (-25.6 °F)

Lever

2.89 in (73.41 mm)

1.9 in (48.26 mm)

Trip

1.44 in (36.58 mm)

SAE; UL

1

82 °C (179.6 °F)

S201-B13

Abb

Thermal Magnetic Circuit Breaker

2TC2-3

Texas Instruments

Thermal Circuit Breaker

Panel Mount

120 V

28 V

3 A

Screw

2.5 kA

2TC2

Push-Pull

0.781 in (19.84 mm)

0.593 in (15.06 mm)

Corrosion Resistant

0.781 x 0.593 x 1.03 in (19.84 x 15.06 x 26.16 mm)

1.03 in (26.16 mm)

2CDS251001R0427

Abb

Thermal Magnetic Circuit Breaker

SU202M-Z5

Abb

Thermal Magnetic Circuit Breaker

QOB250

Schneider Electric Sa

Thermal Circuit Breaker

QOB250HID

Schneider Electric Sa

Thermal Circuit Breaker

S203-B20

Abb

Thermal Magnetic Circuit Breaker

3RV2041-4JA15

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

63 A

Screw And Snap On

-20 °C (-4 °F)

3 kA

Rotary Handle

6.496 in (165 mm)

2.756 in (70 mm)

IP00; IP20

6.496 x 2.756 x 6.929 in (165 x 70 x 176 mm)

Trip

6.929 in (176 mm)

3

60 °C (140 °F)

4411.0017

Schurter Ag

Thermal Circuit Breaker

Panel Mount

277 V

28 V

30 A

Quick Connect

-5 °C (23 °F)

1 kA

Reset Type

Bulk

1.22 in (31 mm)

0.453 in (11.5 mm)

IP40

Trip Free

1.772 in (45 mm)

CCC; CSA; GB; IEC; UL; VDE

1

60 °C (140 °F)

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.