Circuit Breaker

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

S201UDC-K3

Abb

Thermal Magnetic Circuit Breaker

W28-XQ1A-8

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

32 V

8 A

Quick Connect

1 kA

2.2 s

Push To Reset

0.625 in (15.88 mm)

0.54 in (13.72 mm)

0.625 x 0.54 x 1.535 in (15.88 x 13.72 x 38.99 mm)

Series Trip

1.535 in (38.99 mm)

CSA; UL; VDE

1

2CDS252001R0024

Abb

Thermal Magnetic Circuit Breaker

420362

Legrand

Thermal Circuit Breaker

DIN Rail Mount

400 V

40 A

Snap On

-25 °C (-13 °F)

50 kA

Handle

Bulk

6.496 in (165 mm)

4.134 in (105 mm)

Trip

3.937 in (100 mm)

IEC

3

70 °C (158 °F)

W28-XQ1A-20

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

32 V

20 A

Quick Connect

1 kA

2.2 s

Push To Reset

0.625 in (15.88 mm)

0.54 in (13.72 mm)

0.625 x 0.54 x 1.535 in (15.88 x 13.72 x 38.99 mm)

Series Trip

1.535 in (38.99 mm)

CSA; SEV; UL; VDE

1

W28-XQ1A20

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

32 V

20 A

Quick Connect

2.2 s

Push To Reset

Series Trip

1

W28XQ1A20

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

32 V

20 A

Quick Connect

2.2 s

Push To Reset

Series Trip

1

1393255-8

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

30 A

Stud

-40 °C (-40 °F)

5 kA

2.2 s

Toggle

2.5 in (63.5 mm)

2.25 in (57.15 mm)

Series Trip

1.845 in (46.86 mm)

3

85 °C (185 °F)

A9F07150

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

W68-X2Q12-20

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

20 A

Quick Connect

-40 °C (-40 °F)

5 kA

2.2 s

Toggle

2 in (50.8 mm)

1.5 in (38.1 mm)

Fungus Resistant; Moisture Resistant

2 x 1.5 x 1.64 in (50.8 x 38.1 x 41.66 mm)

Series Trip

1.64 in (41.66 mm)

CSA; UL

2

85 °C (185 °F)

Standard

2CDS251001R0337

Abb

Thermal Magnetic Circuit Breaker

GV3P50

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail And Panel Mount

690 V

50 A

Screw And Snap On

-20 °C (-4 °F)

6 kA

Reference standard: UL

Rotary Handle

Bulk

5.197 in (132 mm)

2.165 in (55 mm)

IK09; IP20

Trip

5.354 in (136 mm)

ABS; ATEX; BV; CSA; CCC; DNV-GL; EAC; EN; IEC; LR0S; UKCA

3

60 °C (140 °F)

CTB-B-B-05

Carling Technologies

Thermal Circuit Breaker

Panel Mount

250 V

50 V

5 A

Quick Connect

1 kA

Rocker

0.76 in (19.31 mm)

0.76 in (19.31 mm)

Series Trip

1.535 in (38.99 mm)

CE; CUL; UL; VDE

1

S201M-C25

Abb

Thermal Magnetic Circuit Breaker

MS3320-1

Defense Logistics Agency

Thermal Circuit Breaker

Panel Mount

120 V

28 V

1 A

Screw

-55 °C (-67 °F)

3.5 kA

Rated breaking capacity at 28 VDC: 6000 A

Push-Pull

0.781 in (19.84 mm)

0.593 in (15.06 mm)

Corrosion Resistant; Moisture Resistant

0.781 x 0.593 x 1.03 in (19.84 x 15.06 x 26.16 mm)

Trip Free

1.03 in (26.16 mm)

MIL-C-5809

1

121 °C (249.8 °F)

MS3320-20

Defense Logistics Agency

Thermal Circuit Breaker

Panel Mount

120 V

28 V

20 A

Screw

-55 °C (-67 °F)

2 kA

Rated breaking capacity at 28 VDC: 6000 A

Push-Pull

0.781 in (19.84 mm)

0.593 in (15.06 mm)

Corrosion Resistant; Moisture Resistant

0.781 x 0.593 x 1.03 in (19.84 x 15.06 x 26.16 mm)

Trip Free

1.03 in (26.16 mm)

MIL-C-5809

1

121 °C (249.8 °F)

3RV2011-1DA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

3.2 A

Snap On

-20 °C (-4 °F)

10 kA

Interrupting current max at 450 VDC: 10000 A

Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

W28-XQ1A-12

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

32 V

12 A

Quick Connect

1 kA

2.2 s

Push To Reset

0.625 in (15.88 mm)

0.54 in (13.72 mm)

0.625 x 0.54 x 1.535 in (15.88 x 13.72 x 38.99 mm)

Series Trip

1.535 in (38.99 mm)

CSA; UL; VDE

1

W28-XQ1A12

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

32 V

12 A

Quick Connect

2.2 s

Push To Reset

Series Trip

1

W28XQ1A12

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

32 V

12 A

Quick Connect

2.2 s

Push To Reset

Series Trip

1

24337

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail Mount

415 V

16 A

Snap On

-25 °C (-13 °F)

3 kA

Toggle

3.189 in (81 mm)

1.417 in (36 mm)

Trip

2.874 in (73 mm)

2

60 °C (140 °F)

3VA2340-5HL32-0AA0

Siemens

Thermal Circuit Breaker

Panel Mount

690 V

400 A

Screw

-25 °C (-13 °F)

55 kA

Toggle

9.8 in (248.92 mm)

5.4 in (137.16 mm)

IP40

9.8 x 5.4 x 4.3 in (248.92 x 137.16 x 109.22 mm)

Trip

4.3 in (109.22 mm)

3

70 °C (158 °F)

5SY4110-7

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

10 A

Snap On

-25 °C (-13 °F)

5 kA

5SY4110-7

Environmental Characteristics: IP20; Sealed

3.535 in (89.8 mm)

0.693 in (17.6 mm)

Environment/Moisture Resistant

3.535 x 0.693 x 2.764 in (89.8 x 17.6 x 70.2 mm)

Trip

2.764 in (70.2 mm)

CE; EAC; IMQ; KTL; UL; VDE

1

55 °C (131 °F)

FAZ-C15/2-RT

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

15 A

Snap On

-25 °C (-13 °F)

14 kA

Toggle

4.134 in (105 mm)

1.39 in (35.3 mm)

Trip Free

1.772 in (45 mm)

CSA; UL

2

75 °C (167 °F)

1620-2-10A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

12 V

10 A

Quick Connect

-40 °C (-40 °F)

150 A

Modified Reset

0.524 in (13.3 mm)

0.276 in (7 mm)

Corrosion Resistant; IP00; IP50

Trip

0.984 in (25 mm)

1

85 °C (185 °F)

2TC2-20

Texas Instruments

Thermal Circuit Breaker

Panel Mount

120 V

28 V

20 A

Screw

2 kA

2TC2

Push-Pull

0.781 in (19.84 mm)

0.593 in (15.06 mm)

Corrosion Resistant

0.781 x 0.593 x 1.03 in (19.84 x 15.06 x 26.16 mm)

1.03 in (26.16 mm)

2CDS253001R0467

Abb

Thermal Magnetic Circuit Breaker

W23-X1A1G-5

TE Connectivity

Thermal Circuit Breaker

Panel Mount

240 V

50 V

5 A

Screw

1 kA

6 s

Push-Pull

1.384 in (35.15 mm)

0.69 in (17.53 mm)

Corrosion/Environment/Moisture Resistant

Series Trip

1.6 in (40.64 mm)

CSA; UL

1

MS3320-10L

Eaton Corporation

Thermal Circuit Breaker

Panel Mount

120 V

28 V

10 A

Screw

-55 °C (-67 °F)

3.5 kA

Standard: MIL-C-5809, rated breaking capacity at 28 VDC: 6000 A

Push Button

0.781 in (19.84 mm)

0.593 in (15.06 mm)

Corrosion Resistant; Moisture Resistant

0.781 x 0.593 x 1.03 in (19.84 x 15.06 x 26.16 mm)

Trip

1.03 in (26.16 mm)

1

121 °C (249.8 °F)

MS3320-7-1/2

Eaton Corporation

Thermal Circuit Breaker

Panel Mount

120 V

28 V

7.5 A

Screw

-55 °C (-67 °F)

3.5 kA

Standard: MIL-C-5809, rated breaking capacity at 28 VDC: 6000 A

Push Button

0.781 in (19.84 mm)

0.593 in (15.06 mm)

Corrosion Resistant; Moisture Resistant

0.781 x 0.593 x 1.03 in (19.84 x 15.06 x 26.16 mm)

Trip

1.03 in (26.16 mm)

1

121 °C (249.8 °F)

2800886

Phoenix Contact

Thermal Magnetic Circuit Breaker

2800886

MS3320-2

Defense Logistics Agency

Thermal Circuit Breaker

Panel Mount

120 V

28 V

2 A

Screw

-55 °C (-67 °F)

2.8 kA

Rated breaking capacity at 28 VDC: 6000 A

Push-Pull

0.781 in (19.84 mm)

0.593 in (15.06 mm)

Corrosion Resistant; Moisture Resistant

0.781 x 0.593 x 1.03 in (19.84 x 15.06 x 26.16 mm)

Trip Free

1.03 in (26.16 mm)

MIL-C-5809

1

121 °C (249.8 °F)

M9F42105

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

W33-T4B1Q-5

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

50 V

5 A

Quick Connect

1 kA

3 s

Rocker

1.89 in (48.01 mm)

0.98 in (24.89 mm)

Series Trip

1.724 in (43.79 mm)

2

2TC2-2

Texas Instruments

Thermal Circuit Breaker

Panel Mount

120 V

28 V

2 A

Screw

2.8 kA

2TC2

Push-Pull

0.781 in (19.84 mm)

0.593 in (15.06 mm)

Corrosion Resistant

0.781 x 0.593 x 1.03 in (19.84 x 15.06 x 26.16 mm)

1.03 in (26.16 mm)

SU201M-K10

Abb

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

10 A

Screw And Snap On

-25 °C (-13 °F)

10 kA

200 ms

Bulk

4.37 in (111 mm)

0.689 in (17.5 mm)

IP20; IP40

Shunt Trip

2.717 in (69 mm)

CCC; CSA; EN; IEC; UL; VDE

1

55 °C (131 °F)

Instantaneous

2800854

Phoenix Contact

Thermal Magnetic Circuit Breaker

3120-N321-P7T1-W19DG4-10A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

10 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

Corrosion/Moisture Resistant; IP00; IP40

Manual On/Off

CCC; CE; CSA; CQC; KTL; UL; VDE

2

60 °C (140 °F)

BA1-B0-14-450-225-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

80 V

5 A

Screw

-40 °C (-40 °F)

7.5 kA

Handle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.73 in (43.94 mm)

CSA; UL

1

85 °C (185 °F)

W31-X2M1G-15

TE Connectivity

Thermal Circuit Breaker

Panel Mount

240 V

50 V

15 A

Screw

1 kA

6 s

Toggle

1.384 in (35.15 mm)

0.69 in (17.53 mm)

Corrosion/Environment/Moisture Resistant

Series Trip

1.6 in (40.64 mm)

CSA; UL

1

MS3320-20V

Eaton Corporation

Thermal Circuit Breaker

Panel Mount

120 V

28 V

20 A

Screw

-55 °C (-67 °F)

3.5 kA

Standard: MIL-C-5809, rated breaking capacity at 28 VDC: 6000 A

Push Button

0.781 in (19.84 mm)

0.593 in (15.06 mm)

Corrosion Resistant; Moisture Resistant

0.781 x 0.593 x 1.03 in (19.84 x 15.06 x 26.16 mm)

Trip

1.03 in (26.16 mm)

1

121 °C (249.8 °F)

S204M-C25

Abb

Thermal Magnetic Circuit Breaker

S202M-C63

Abb

Thermal Magnetic Circuit Breaker

4435.0013

Schurter Ag

Thermal Circuit Breaker

Panel Mount

240 V

60 V

20 A

Quick Connect

-30 °C (-22 °F)

2 kA

Rocker

Bulk

1.417 in (36 mm)

1.142 in (29 mm)

IP40

Trip Free

1.736 in (44.1 mm)

CCC; CSA; GB; IEC; UL; VDE

2

60 °C (140 °F)

S203-D16

Abb

Thermal Magnetic Circuit Breaker

1610-21-5A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Inline/Holder

24 V

5 A

Tab/Blade

-40 °C (-40 °F)

150 A

Push To Reset

0.787 in (20 mm)

0.236 in (6 mm)

Corrosion/Moisture Resistant; IP00; IP30

Trip Free

0.945 in (24 mm)

UL

1

85 °C (185 °F)

BB3-B0-46-618-211-D

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

18 A

Screw

-40 °C (-40 °F)

3 kA

Handle

2.265 in (57.53 mm)

2 in (50.8 mm)

Corrosion/Moisture Resistant

Series Trip

1.73 in (43.94 mm)

CSA; UL; VDE

3

85 °C (185 °F)

24205

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.