Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Actuator Type | Packing Method | Body Length/Diameter | Body Width | Environmental Characteristics | JESD-609 Code | Dimensions | Circuit Function | Body Height | Reference Standard | No. of Poles | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Abb |
Thermal Circuit Breaker |
DIN Rail Mount |
480 V |
110 V |
40 A |
Snap On |
-25 °C (-13 °F) |
10 kA |
Toggle Handle |
3.386 in (86 mm) |
2.126 in (54 mm) |
IP20; IP40 |
Trip |
2.677 in (68 mm) |
CE; CSA; UL |
3 |
55 °C (131 °F) |
|||||||||
|
Eaton Corporation |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
240 V |
40 A |
Snap On |
10 kA |
Toggle |
1.39 in (35.3 mm) |
Manual On/Off |
2 |
Low Inrush |
|||||||||||||||
|
Eaton Corporation |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
277 V |
10 A |
Snap On |
10 kA |
Toggle |
Manual On/Off |
1 |
|||||||||||||||||
|
Schneider Electric Sa |
Thermal Magnetic Circuit Breaker |
DIN Rail And Panel Mount |
690 V |
14 A |
Screw And Snap On |
-20 °C (-4 °F) |
3 kA |
Push Button |
Bulk |
3.504 in (89 mm) |
1.772 in (45 mm) |
IK04; IP20 |
3.079 x 1.772 x 3.504 in (78.2 x 45 x 89 mm) |
Trip |
3.091 in (78.5 mm) |
ATEX; BV; CCC; CSA; DNV-GL; EAC; EN; IEC; LROS; RINA; UL |
3 |
60 °C (140 °F) |
||||||||
|
Schneider Electric Sa |
Thermal Magnetic Circuit Breaker |
|||||||||||||||||||||||||
Abb |
Thermal Magnetic Circuit Breaker |
||||||||||||||||||||||||||
|
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
250 V |
50 V |
10 A |
Quick Connect |
1 kA |
6 s |
Push To Reset |
1.375 in (34.93 mm) |
0.66 in (16.76 mm) |
Series Trip |
1.375 in (34.93 mm) |
1 |
||||||||||||
|
TE Connectivity |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
20 A |
Stud |
-40 °C (-40 °F) |
5 kA |
2.2 s |
Toggle |
2.5 in (63.5 mm) |
0.75 in (19.05 mm) |
Series Trip |
1.845 in (46.86 mm) |
1 |
85 °C (185 °F) |
|||||||||||
TE Connectivity |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
20 A |
Stud |
-40 °C (-40 °F) |
5 kA |
2.2 s |
Toggle |
2.5 in (63.5 mm) |
0.75 in (19.05 mm) |
Series Trip |
1.845 in (46.86 mm) |
1 |
85 °C (185 °F) |
||||||||||||
|
Phoenix Contact |
Thermal Magnetic Circuit Breaker |
|||||||||||||||||||||||||
|
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Through Hole Mount |
240 V |
28 V |
3.15 A |
Printed Circuit Board |
-20 °C (-4 °F) |
Silver |
2 kA |
Rated breaking capacity at 50 VDC: 200 A |
Reset Slide |
1.102 in (28 mm) |
0.354 in (9 mm) |
Corrosion Resistant |
e4 |
1.102 x 0.354 x 0.425 in (28 x 9 x 10.8 mm) |
0.425 in (10.8 mm) |
CSA; UL; VDE |
1 |
70 °C (158 °F) |
||||||
Texas Instruments |
Thermal Circuit Breaker |
Panel Mount |
120 V |
28 V |
7.5 A |
Screw |
2.5 kA |
2TC2 |
Push-Pull |
0.781 in (19.84 mm) |
0.593 in (15.06 mm) |
Corrosion Resistant |
0.781 x 0.593 x 1.03 in (19.84 x 15.06 x 26.16 mm) |
1.03 in (26.16 mm) |
|||||||||||||
|
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
240 V |
50 V |
5 A |
Quick Connect |
-30 °C (-22 °F) |
5 kA |
Rated breaking capacity at 50 VDC: 1000 A |
Rocker |
2.22 in (56.4 mm) |
0.984 in (25 mm) |
Corrosion Resistant; IP00; IP40 |
Trip Free |
1.299 in (33 mm) |
CCC; CSA; KC; UL; VDE |
2 |
60 °C (140 °F) |
||||||||
|
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
240 V |
50 V |
10 A |
Quick Connect |
-30 °C (-22 °F) |
5 kA |
Rated breaking capacity at 50 VDC: 1000 A |
Rocker |
2.22 in (56.4 mm) |
0.984 in (25 mm) |
Corrosion Resistant; IP00; IP40 |
Trip Free |
1.299 in (33 mm) |
CCC; CSA; KC; UL; VDE |
2 |
60 °C (140 °F) |
||||||||
|
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
240 V |
50 V |
16 A |
Quick Connect |
-30 °C (-22 °F) |
5 kA |
Rated breaking capacity at 50 VDC: 1000 A |
Rocker |
Corrosion/Moisture Resistant; IP00; IP40 |
Manual On/Off |
CCC; CE; CSA; CQC; KTL; UL; VDE |
2 |
60 °C (140 °F) |
|||||||||||
|
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
240 V |
50 V |
3 A |
Quick Connect |
-30 °C (-22 °F) |
5 kA |
Rated breaking capacity at 50 VDC: 1000 A |
Rocker |
Corrosion/Moisture Resistant; IP00; IP40 |
Manual On/Off |
CCC; CE; CSA; CQC; KTL; UL; VDE |
2 |
60 °C (140 °F) |
|||||||||||
|
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
240 V |
50 V |
6 A |
Quick Connect |
-30 °C (-22 °F) |
5 kA |
Rated breaking capacity at 50 VDC: 1000 A |
Rocker |
Corrosion/Moisture Resistant; IP00; IP40 |
Manual On/Off |
CCC; CE; CSA; CQC; KTL; UL; VDE |
2 |
60 °C (140 °F) |
|||||||||||
|
Siemens |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
690 V |
2 A |
Snap On |
-20 °C (-4 °F) |
10 kA |
Interrupting current max at 450 VDC: 10000 A |
Handle |
3.819 in (97 mm) |
1.772 in (45 mm) |
IP20 |
3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm) |
Trip |
3.815 in (96.9 mm) |
ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE |
3 |
60 °C (140 °F) |
||||||||
|
Siemens |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
690 V |
20 A |
Screw And Snap On |
-20 °C (-4 °F) |
2 kA |
Rotary Handle |
5.669 in (144 mm) |
1.772 in (45 mm) |
IP00; IP20 |
5.669 x 1.772 x 3.819 in (144 x 45 x 97 mm) |
Trip |
3.819 in (97 mm) |
3 |
60 °C (140 °F) |
||||||||||
|
Siemens |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
400 V |
1 A |
Snap On |
10 kA |
3.535 in (89.8 mm) |
1.386 in (35.2 mm) |
IP20 |
3.535 x 1.386 x 2.992 in (89.8 x 35.2 x 76 mm) |
Trip |
2.992 in (76 mm) |
CCC; CE; IMQ; RCM; UL; VDE |
2 |
||||||||||||
|
Schneider Electric Sa |
Thermal Magnetic Circuit Breaker |
|||||||||||||||||||||||||
|
Schneider Electric Sa |
Thermal Magnetic Circuit Breaker |
DIN Rail And Panel Mount |
690 V |
10 A |
Screw And Snap On |
-20 °C (-4 °F) |
3 kA |
Push Button |
Bulk |
3.504 in (89 mm) |
1.772 in (45 mm) |
IK04; IP20 |
Trip |
3.091 in (78.5 mm) |
ATEX; BV; CCC; CSA; DNV-GL; EAC; EN; IEC; LROS; RINA; UL |
3 |
60 °C (140 °F) |
|||||||||
|
Schneider Electric Sa |
Thermal Magnetic Circuit Breaker |
|||||||||||||||||||||||||
|
Schneider Electric Sa |
Thermal Magnetic Circuit Breaker |
|||||||||||||||||||||||||
|
Abb |
Thermal Magnetic Circuit Breaker |
|||||||||||||||||||||||||
Abb |
Thermal Magnetic Circuit Breaker |
||||||||||||||||||||||||||
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
7 A |
Quick Connect |
1 kA |
2.2 s |
Push To Reset |
0.625 in (15.88 mm) |
0.54 in (13.72 mm) |
0.625 x 0.54 x 1.535 in (15.88 x 13.72 x 38.99 mm) |
Series Trip |
1.535 in (38.99 mm) |
CSA; UL; VDE |
1 |
|||||||||||
|
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
250 V |
50 V |
20 A |
Quick Connect |
1 kA |
6 s |
Push To Reset |
1.375 in (34.93 mm) |
0.66 in (16.76 mm) |
Series Trip |
1.375 in (34.93 mm) |
1 |
||||||||||||
|
TE Connectivity |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
10 A |
Quick Connect |
-40 °C (-40 °F) |
5 kA |
2.2 s |
Toggle |
2 in (50.8 mm) |
0.75 in (19.05 mm) |
Fungus Resistant; Moisture Resistant |
2 x 0.75 x 1.64 in (50.8 x 19.05 x 41.66 mm) |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL |
1 |
85 °C (185 °F) |
Standard |
|||||||
|
TE Connectivity |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
50 A |
Stud |
-40 °C (-40 °F) |
5 kA |
2.2 s |
Toggle |
2.5 in (63.5 mm) |
2.25 in (57.15 mm) |
Series Trip |
1.845 in (46.86 mm) |
3 |
85 °C (185 °F) |
|||||||||||
|
Phoenix Contact |
Thermal Circuit Breaker |
|||||||||||||||||||||||||
Eaton Corporation |
Thermal Circuit Breaker |
Panel Mount |
30 V |
40 A |
Screw |
-32 °C (-25.6 °F) |
Lever |
2.89 in (73.41 mm) |
1.9 in (48.26 mm) |
Trip |
1.44 in (36.58 mm) |
SAE; UL |
1 |
82 °C (179.6 °F) |
|||||||||||||
Eaton Corporation |
Thermal Circuit Breaker |
Panel Mount |
30 V |
40 A |
Screw |
-32 °C (-25.6 °F) |
Lever |
2.89 in (73.41 mm) |
1.9 in (48.26 mm) |
Trip |
1.44 in (36.58 mm) |
SAE; UL |
1 |
82 °C (179.6 °F) |
|||||||||||||
|
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
240 V |
50 V |
10 A |
Quick Connect |
-30 °C (-22 °F) |
5 kA |
Rated breaking capacity at 50 VDC: 1000 A |
Rocker |
2.22 in (56.4 mm) |
0.984 in (25 mm) |
Corrosion Resistant; IP00; IP40 |
Trip Free |
1.299 in (33 mm) |
CCC; CSA; KC; UL; VDE |
2 |
60 °C (140 °F) |
||||||||
|
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
240 V |
50 V |
3 A |
Quick Connect |
-30 °C (-22 °F) |
5 kA |
Rated breaking capacity at 50 VDC: 1000 A |
Rocker |
2.22 in (56.4 mm) |
0.984 in (25 mm) |
Corrosion Resistant; IP00; IP40 |
Trip Free |
1.299 in (33 mm) |
CCC; CSA; KC; UL; VDE |
2 |
60 °C (140 °F) |
||||||||
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
115 V |
28 V |
60 A |
Screw |
-55 °C (-67 °F) |
6 kA |
Push-Pull |
1.26 in (32 mm) |
0.748 in (19 mm) |
Corrosion/Moisture Resistant; IP00; IP40 |
Tease-Free And Trip-Free |
1.929 in (49 mm) |
CSA; UL |
1 |
75 °C (167 °F) |
||||||||||
|
Schurter Ag |
Thermal Circuit Breaker |
Panel Mount |
277 V |
28 V |
30 A |
Screw |
-5 °C (23 °F) |
1 kA |
Reset Type |
Bulk |
1.22 in (31 mm) |
0.453 in (11.5 mm) |
Trip |
1.772 in (45 mm) |
CCC; CSA; UL; VDE |
1 |
60 °C (140 °F) |
|||||||||
|
Siemens |
Thermal Circuit Breaker |
DIN Rail Mount |
400 V |
4 A |
Snap On |
-25 °C (-13 °F) |
5 kA |
5SY4104-7 |
Environmental Characteristics: IP20; Sealed |
3.535 in (89.8 mm) |
0.693 in (17.6 mm) |
Environment/Moisture Resistant |
3.535 x 0.693 x 2.764 in (89.8 x 17.6 x 70.2 mm) |
Trip |
2.764 in (70.2 mm) |
CCC; CE; EAC; GOST; IMQ; KTL; UL; VDE |
1 |
55 °C (131 °F) |
||||||||
|
Siemens |
Thermal Circuit Breaker |
DIN Rail Mount |
400 V |
500 V |
6 A |
Screw |
10 kA |
Handle |
3.543 in (90 mm) |
1.417 in (36 mm) |
IP20 |
3.543 x 1.417 x 2.992 in (90 x 36 x 76 mm) |
Trip |
2.992 in (76 mm) |
2 |
|||||||||||
Sensata Technologies |
Thermal Circuit Breaker |
6752-100 |
|||||||||||||||||||||||||
|
Carling Technologies |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
10 A |
Quick Connect |
-10 °C (14 °F) |
300 A |
Rated breaking capacity at 32 VDC: 2500 A |
Push To Reset |
1.378 in (35 mm) |
0.571 in (14.5 mm) |
Fire Resistant |
Series Trip |
1.693 in (43 mm) |
CE; TUV; UL |
1 |
60 °C (140 °F) |
||||||||
Altech |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
250 V |
15 A |
Snap On |
-25 °C (-13 °F) |
10 kA |
Toggle Handle |
Bulk |
4.291 in (109 mm) |
1.378 in (35 mm) |
IP20 |
Trip |
2.362 in (60 mm) |
CE, CUL, UL |
2 |
60 °C (140 °F) |
||||||||||
Eaton Corporation |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
240 V |
5 A |
Snap On |
10 kA |
Toggle |
Manual On/Off |
1 |
||||||||||||||||||
|
Eaton Corporation |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
10 A |
Snap On |
-25 °C (-13 °F) |
10 kA |
Toggle |
4.134 in (105 mm) |
1.39 in (35.3 mm) |
Trip Free |
1.772 in (45 mm) |
CSA; UL |
2 |
75 °C (167 °F) |
|||||||||||
|
Schneider Electric Sa |
Thermal Magnetic Circuit Breaker |
DIN Rail And Panel Mount |
690 V |
1 A |
Screw And Snap On |
-20 °C (-4 °F) |
100 kA |
Push Button |
Bulk |
3.504 in (89 mm) |
1.772 in (45 mm) |
IK04; IP20 |
3.079 x 1.772 x 3.504 in (78.2 x 45 x 89 mm) |
Trip |
3.091 in (78.5 mm) |
EN; IEC |
3 |
60 °C (140 °F) |
||||||||
|
Schneider Electric Sa |
Thermal Magnetic Circuit Breaker |
DIN Rail And Panel Mount |
690 V |
10 A |
Screw And Snap On |
-20 °C (-4 °F) |
3 kA |
Push Button |
Bulk |
3.976 in (101 mm) |
1.772 in (45 mm) |
IK04; IP20 |
3.079 x 1.772 x 3.976 in (78.2 x 45 x 101 mm) |
Trip |
3.091 in (78.5 mm) |
ATEX; BV; CCC; CSA; DNV-GL; EAC; EN; IEC; LROS; RINA; UL |
3 |
60 °C (140 °F) |
||||||||
|
Schneider Electric Sa |
Thermal Magnetic Circuit Breaker |
DIN Rail And Panel Mount |
690 V |
10 A |
Screw And Snap On |
-20 °C (-4 °F) |
3 kA |
Push Button |
Bulk |
3.504 in (89 mm) |
1.752 in (44.5 mm) |
IK04; IP20 |
Trip |
3.079 in (78.2 mm) |
EN; IEC |
3 |
60 °C (140 °F) |
|||||||||
|
Schneider Electric Sa |
Thermal Magnetic Circuit Breaker |
A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.
Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.
In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.