Circuit Breaker

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

0903037

Phoenix Contact

Magnetic Circuit Breaker

DIN Rail Mount

8 A

Screw

0 °C (32 °F)

Bulk

3.15 in (80 mm)

0.492 in (12.5 mm)

IP20

3.268 in (83 mm)

CE, UL

50 °C (122 °F)

0916604

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

240 V

28 V

1 A

Screw

-30 °C (-22 °F)

3.524 in (89.5 mm)

0.484 in (12.3 mm)

IP20; IP40

3.524 x 0.484 x 3.366 in (89.5 x 12.3 x 85.5 mm)

3.366 in (85.5 mm)

CSA; CUL; EN; UL; VDE

1

60 °C (140 °F)

1140-G151-P7M1-16A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

250 V

50 V

16 A

Quick Connect

-20 °C (-4 °F)

2 kA

Push To Reset

0.748 in (19 mm)

0.433 in (11 mm)

Corrosion Resistant; IP00; IP40

Trip Free

2.374 in (60.3 mm)

CSA; UL; VDE

2

60 °C (140 °F)

18644

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

3C1UR

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

1 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle

Bulk

3.516 in (89.3 mm)

2.067 in (52.5 mm)

IP20

Trip

2.693 in (68.4 mm)

CE; CUL; UL

3

55 °C (131 °F)

3RV1021-1EA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail And Panel Mount

690 V

4 A

Screw And Snap On

6 kA

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.78 in (97 x 45 x 96 mm)

Trip

3.78 in (96 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; UL; VDE

3

3RV2011-1FA20

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

5 A

Snap On

-20 °C (-4 °F)

4 kA

Handle

4.173 in (106 mm)

1.772 in (45 mm)

IP20

4.173 x 1.772 x 3.815 in (106 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; UL; VDE

3

60 °C (140 °F)

Instantaneous

5SY4208-8

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

400 V

8 A

Snap On

-25 °C (-13 °F)

5 kA

Interrupting current max(DC): 10000 A

3.535 in (89.8 mm)

1.386 in (35.2 mm)

3.535 x 1.386 x 2.992 in (89.8 x 35.2 x 76 mm)

Trip

2.992 in (76 mm)

CCC; CE; GOST; IMQ; UL; VDE

2

55 °C (131 °F)

7274-2-1/2

Sensata Technologies

Thermal Circuit Breaker

7274-2

9926291120

Weidmueller & Kg

Equipment Leakage Circuit Breaker

BB3-B0-26-620-121-D

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

20 A

Quick Connect

-40 °C (-40 °F)

1.5 kA

Toggle Handle

2 in (50.8 mm)

2.265 in (57.53 mm)

Corrosion/Moisture Resistant

Series Trip

1.73 in (43.94 mm)

CSA; UL; VDE

3

85 °C (185 °F)

C13-B9-46-610-543-R

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

10 A

Screw

-40 °C (-40 °F)

5 kA

Rocker

2.5 in (63.5 mm)

2.265 in (57.53 mm)

Corrosion/Moisture Resistant

Series Trip

1.85 in (47 mm)

CSA; TUV; UL

3

85 °C (185 °F)

CCP2-3-60CF

Eaton Corporation

Equipment Leakage Circuit Breaker

600 V

125 V

60 A

200 kA

Toggle Handle

3 in (76.2 mm)

3 in (76.2 mm)

4.5 in (114.3 mm)

UL

3

F202AC-40/0,03

Abb

Equipment Leakage Circuit Breaker

FAZ-C63/3

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

96 V

63 A

Snap On

-40 °C (-40 °F)

15 kA

Toggle

3.15 in (80 mm)

2.091 in (53.1 mm)

IP20

Manual On/Off

2.362 in (60 mm)

CCC; CE; CSA; IEC; UL; VDE

3

75 °C (167 °F)

Short

GV3P65

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

Panel Mount

690 V

65 A

Screw

-20 °C (-4 °F)

6 kA

Reference standard: UL

Rotary Handle

Bulk

5.197 in (132 mm)

2.165 in (55 mm)

IK09; IP20

Trip

5.354 in (136 mm)

ATEX; ABS; BV; CCC; CSA; DNV-GL; EAC; EN; IEC; LROS; UKCA

3

60 °C (140 °F)

MS3320-15L

Eaton Corporation

Thermal Circuit Breaker

Panel Mount

120 V

28 V

15 A

Screw

-55 °C (-67 °F)

3.5 kA

Standard: MIL-C-5809, rated breaking capacity at 28 VDC: 6000 A

Push Button

0.781 in (19.84 mm)

0.593 in (15.06 mm)

Corrosion Resistant; Moisture Resistant

0.781 x 0.593 x 1.03 in (19.84 x 15.06 x 26.16 mm)

Trip

1.03 in (26.16 mm)

1

121 °C (249.8 °F)

S202M-B6

Abb

Thermal Magnetic Circuit Breaker

S803N-C125

Abb

Thermal Magnetic Circuit Breaker

0712233

Phoenix Contact

Thermal Circuit Breaker

0712233

279-2-1-52-9-2-90

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

160 V

90 A

Quick Connect

5 kA

Toggle Handle

5.8 in (147.32 mm)

2.072 in (52.63 mm)

Moisture Resistant

Trip Free

2.61 in (66.29 mm)

CSA; CUL; UL

2

2D4UL

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

4 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.146 in (105.3 mm)

1.378 in (35 mm)

Trip

2.693 in (68.4 mm)

CE, CUL, UL

2

55 °C (131 °F)

2DU15L

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

15 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.291 in (109 mm)

1.378 in (35 mm)

IP20

Trip

2.362 in (60 mm)

CE, CUL, UL

2

60 °C (140 °F)

3120-F321-P7T1-W01D-20A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

250 V

50 V

20 A

Quick Connect

-30 °C (-22 °F)

20 A

Rocker

2.126 in (54 mm)

0.827 in (21 mm)

Corrosion Resistant

2.126 x 0.827 x 1.299 in (54 x 21 x 33 mm)

Manual On/Off

1.299 in (33 mm)

CCC; CSA; UL; VDE

2

60 °C (140 °F)

3RV2021-4EA10-0DA0

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

32 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

Rotary Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.819 in (97 x 45 x 97 mm)

Trip

3.819 in (97 mm)

3

60 °C (140 °F)

3RV2031-4PA15

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

36 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

Rotary Handle

5.512 in (140 mm)

2.165 in (55 mm)

IP00; IP20

5.512 x 2.165 x 5.866 in (140 x 55 x 149 mm)

Trip

5.866 in (149 mm)

3

60 °C (140 °F)

3RV2811-1GD10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

6.3 A

Screw And Snap On

-20 °C (-4 °F)

4 kA

Rotary Handle

5.669 in (144 mm)

1.772 in (45 mm)

IP00; IP20

5.669 x 1.772 x 3.819 in (144 x 45 x 97 mm)

Trip

3.819 in (97 mm)

3

60 °C (140 °F)

3VA5340-6EF31-0AA0

Siemens

Thermal Circuit Breaker

Panel Mount

600 V

500 V

400 A

Screw

-25 °C (-13 °F)

65 kA

Toggle

9.8 in (248.92 mm)

5.4 in (137.16 mm)

IP40

9.8 x 5.4 x 4.3 in (248.92 x 137.16 x 109.22 mm)

Trip

4.3 in (109.22 mm)

3

70 °C (158 °F)

3VA5440-1MU31-0AA0

Siemens

Thermal Circuit Breaker

Panel Mount

600 V

400 A

Screw

-25 °C (-13 °F)

150 kA

Toggle

9.8 in (248.92 mm)

5.4 in (137.16 mm)

IP40

9.8 x 5.4 x 4.3 in (248.92 x 137.16 x 109.22 mm)

Trip

4.3 in (109.22 mm)

3

70 °C (158 °F)

410212

Legrand

Thermal Magnetic Circuit Breaker

DIN Rail Mount

400 V

10 A

Snap On

-25 °C (-13 °F)

50 kA

Toggle Handle

Bulk

4.106 in (104.3 mm)

3.154 in (80.1 mm)

Manual On/Off

3.11 in (79 mm)

IEC

3

70 °C (158 °F)

410229

Legrand

Thermal Magnetic Circuit Breaker

DIN Rail Mount

400 V

32 A

Snap On

-25 °C (-13 °F)

50 kA

Toggle Handle

Bulk

4.106 in (104.3 mm)

4.205 in (106.8 mm)

Manual On/Off

3.11 in (79 mm)

IEC

4

70 °C (158 °F)

4435.0019

Schurter Ag

Thermal Circuit Breaker

Panel Mount

277 V

32 V

3 A

Quick Connect

-30 °C (-22 °F)

2 kA

Rocker

Bulk

1.417 in (36 mm)

0.689 in (17.5 mm)

Trip

1.319 in (33.5 mm)

CCC; CUL; UL; VDE

1

60 °C (140 °F)

4435.0039

Schurter Ag

Thermal Circuit Breaker

Panel Mount

240 V

60 V

5 A

Quick Connect

-30 °C (-22 °F)

2 kA

Rocker

Bulk

1.417 in (36 mm)

1.142 in (29 mm)

IP40

Trip Free

1.736 in (44.1 mm)

CCC; CSA; GB; IEC; UL; VDE

2

60 °C (140 °F)

5-1423674-4

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

50 V

25 A

Quick Connect

0 °C (32 °F)

1 kA

5 s

Push To Reset

1.378 in (35 mm)

0.575 in (14.6 mm)

Series Trip

1.22 in (31 mm)

1

60 °C (140 °F)

5SU1356-7KK06

Siemens

Equipment Leakage Circuit Breaker

DIN Rail Mount

230 V

6 A

Snap On

-25 °C (-13 °F)

6 kA

Bulk

3.543 in (90 mm)

1.417 in (36 mm)

IP20

Trip

3.031 in (77 mm)

CCC; CE; IMQ; RCM; VDE

2

55 °C (131 °F)

5SU1356-7KK10

Siemens

Thermal Circuit Breaker

DIN Rail Mount

230 V

10 A

Snap On

-25 °C (-13 °F)

5SU1356-7KK10

3.543 in (90 mm)

1.417 in (36 mm)

Environment/Moisture Resistant

3.543 x 1.417 x 2.756 in (90 x 36 x 70 mm)

Trip

2.756 in (70 mm)

CCC; CE; GOST; IMQ; OVE; VDE

1

55 °C (131 °F)

5SY4301-7

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

400 V

1 A

Snap On

10 kA

3.535 in (89.8 mm)

2.079 in (52.8 mm)

IP20

3.535 x 2.079 x 2.992 in (89.8 x 52.8 x 76 mm)

Trip

2.992 in (76 mm)

CCC; CE; IMQ; KC; RCM; UL; VDE

3

AA1-B0-14-625-1B1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

80 V

25 A

Quick Connect

-40 °C (-40 °F)

7.5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

CA1-B0-14-673-321-I

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

65 V

73 A

Stud

-40 °C (-40 °F)

1.5 kA

Handle

2.5 in (63.5 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.85 in (47 mm)

CSA, UL

1

85 °C (185 °F)

CA3-B0-22-620-122-D

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

480 V

150 V

20 A

Stud

-40 °C (-40 °F)

10 kA

Handle

1.85 in (47 mm)

2.265 in (57.53 mm)

Series Trip

2.5 in (63.5 mm)

UL

3

85 °C (185 °F)

CLB-103-27E6A-B-A

Carling Technologies

Thermal Circuit Breaker

Panel Mount

250 V

32 V

10 A

Quick Connect

-10 °C (14 °F)

300 A

Rated breaking capacity at 32 VDC: 2500 A

Push To Reset

1.378 in (35 mm)

0.571 in (14.5 mm)

Fire Resistant

Series Trip

1.693 in (43 mm)

CE; TUV; UL

1

60 °C (140 °F)

DS201MC16A30

Abb

Equipment Leakage Circuit Breaker

FAZ-B6/3

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

96 V

6 A

Snap On

-40 °C (-40 °F)

15 kA

Toggle

3.15 in (80 mm)

2.091 in (53.1 mm)

IP20

Manual On/Off

2.362 in (60 mm)

CCC; CE; CSA; IEC; UL; VDE

3

75 °C (167 °F)

Short

IEG1-1-61-20.0-91-V

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

240 V

20 A

Quick Connect

-40 °C (-40 °F)

2 kA

Toggle

2 in (50.8 mm)

0.75 in (19.05 mm)

Corrosion/Moisture Resistant

Trip Free

1.687 in (42.85 mm)

CCC; VDE

1

85 °C (185 °F)

PDLA-150

Sensata Technologies

Thermal Circuit Breaker

Panel Mount

30 V

150 A

Screw

Push Button

3.125 in (79.38 mm)

1.859 in (47.22 mm)

Trip

1.078 in (27.38 mm)

CCC

PDLA-150-I

Sensata Technologies

Thermal Circuit Breaker

Panel Mount

30 V

150 A

Screw

Push Button

3.125 in (79.38 mm)

1.859 in (47.22 mm)

Trip

1.078 in (27.38 mm)

CCC

SU201M-K2

Abb

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

2 A

Screw And Snap On

-25 °C (-13 °F)

10 kA

Interrupting current max at 277 VAC

2.717 in (69 mm)

0.689 in (17.5 mm)

Environment Resistant; IP20; IP40

2.717 x 0.689 x 4.37 in (69 x 17.5 x 111 mm)

Trip

4.37 in (111 mm)

CE; CSA; EN; IEC; UL

1

55 °C (131 °F)

TS-709-5

Schurter Ag

Thermal Circuit Breaker

Panel Mount

125 V

32 V

5 A

Quick Connect

1 kA

Push To Reset

1.161 in (29.5 mm)

0.563 in (14.3 mm)

Trip Free

0.886 in (22.5 mm)

UL

1

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.