Circuit Breaker

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

M9F43108

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

SU202M-C10

Abb

Thermal Magnetic Circuit Breaker

W57-XB1A4A10-15

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

50 V

15 A

Quick Connect

0 °C (32 °F)

1 kA

4 s

Push To Reset

1.15 in (29.2 mm)

0.575 in (14.6 mm)

Series Trip

0.89 in (22.6 mm)

1

60 °C (140 °F)

W92-X112-20

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

20 A

Stud

-40 °C (-40 °F)

5 kA

2.2 s

Toggle

2.5 in (63.5 mm)

1.5 in (38.1 mm)

Series Trip

1.845 in (46.86 mm)

2

85 °C (185 °F)

0712259

Phoenix Contact

Thermal Circuit Breaker

Panel Mount

250 V

65 V

4 A

Quick Connect

-20 °C (-4 °F)

24 A

Push To Reset

Bulk

0.961 in (24.4 mm)

0.323 in (8.2 mm)

IP40

1.752 x 0.323 x 0.961 in (44.5 x 8.2 x 24.4 mm)

Trip

1.752 in (44.5 mm)

CCC; CSA; CUL; EAC; UL; VDE

1

60 °C (140 °F)

1658-G21-02-P10-10A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Inline/Holder

240 V

28 V

10 A

Tab/Blade

-20 °C (-4 °F)

200 A

Manual Reset

1.26 in (32 mm)

0.551 in (14 mm)

Trip Free

1.563 in (39.7 mm)

CSA; CUL; UL; VDE

1

60 °C (140 °F)

1SDA068058R1

Abb

Thermal Magnetic Circuit Breaker

3RV2011-1HA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

450 V

8 A

Screw And Snap On

-20 °C (-4 °F)

4 kA

Rotary Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.78 in (97 x 45 x 96 mm)

Trip

3.78 in (96 mm)

3

60 °C (140 °F)

410218

Legrand

Thermal Magnetic Circuit Breaker

DIN Rail Mount

400 V

50 A

Snap On

-25 °C (-13 °F)

50 kA

Toggle Handle

Bulk

4.106 in (104.3 mm)

3.154 in (80.1 mm)

Manual On/Off

3.11 in (79 mm)

IEC

3

70 °C (158 °F)

AA1-B0-26-430-1B1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

3 A

Quick Connect

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

FAZ-C40/3

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

96 V

40 A

Snap On

-40 °C (-40 °F)

15 kA

Toggle

3.15 in (80 mm)

2.091 in (53.1 mm)

IP20

Manual On/Off

2.362 in (60 mm)

CCC; CE; CSA; IEC; UL; VDE

3

75 °C (167 °F)

Short

GV2ME06

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail And Panel Mount

690 V

1.6 A

Screw And Snap On

-20 °C (-4 °F)

100 kA

Push Button

Bulk

3.504 in (89 mm)

1.772 in (45 mm)

IK04; IP20

Trip

3.091 in (78.5 mm)

EN; IEC

3

60 °C (140 °F)

LV429843

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

M9F43220

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

W33-S1N1Q-10

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

50 V

10 A

Quick Connect

3 s

Rocker

1.89 in (48.01 mm)

0.98 in (24.89 mm)

Series Trip

1.724 in (43.79 mm)

2

W58-XB1A4A-6

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

50 V

6 A

Quick Connect

6 s

Push To Reset

Series Trip

1

1C6UL

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

6 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle

Bulk

4.146 in (105.3 mm)

0.689 in (17.5 mm)

Trip

2.693 in (68.4 mm)

CE, CUL, UL

1

55 °C (131 °F)

2CCP814001R1849

Abb

Thermal Magnetic Circuit Breaker

2CCP814001R1849

2DU5L

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

5 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.291 in (109 mm)

1.378 in (35 mm)

IP20

Trip

2.362 in (60 mm)

CE, CUL, UL

2

60 °C (140 °F)

3120-F323-P7T1-W02D-1.5A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

250 V

50 V

1.5 A

Quick Connect

-30 °C (-22 °F)

15 A

Rocker

2.126 in (54 mm)

0.827 in (21 mm)

Corrosion Resistant

2.126 x 0.827 x 1.299 in (54 x 21 x 33 mm)

Manual On/Off

1.299 in (33 mm)

CCC; CSA; UL; VDE

2

60 °C (140 °F)

5SY4202-8

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

400 V

2 A

Snap On

10 kA

3.535 in (89.8 mm)

1.386 in (35.2 mm)

IP20

3.535 x 1.386 x 2.992 in (89.8 x 35.2 x 76 mm)

Trip

2.992 in (76 mm)

CCC; CE; IMQ; RCM; UL; VDE

2

5SY4213-8

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

400 V

13 A

Snap On

-25 °C (-13 °F)

5 kA

Interrupting current max(DC): 10000 A

3.535 in (89.8 mm)

1.386 in (35.2 mm)

3.535 x 1.386 x 2.992 in (89.8 x 35.2 x 76 mm)

Trip

2.992 in (76 mm)

CCC; CE; GOST; IMQ; UL; VDE

2

55 °C (131 °F)

AA1-B0-26-470-1B1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

7 A

Quick Connect

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

C13-B9-46-610-546-R

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

10 A

Screw

-40 °C (-40 °F)

5 kA

Rocker

2.5 in (63.5 mm)

2.265 in (57.53 mm)

Corrosion/Moisture Resistant

Series Trip

1.85 in (47 mm)

CSA; TUV; UL

3

85 °C (185 °F)

CM1-B0-22-420-201-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

2 A

Screw

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Toggle

2.5 in (63.5 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.85 in (47 mm)

CSA; UL

1

85 °C (185 °F)

FAZ-C6/3

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

6 A

Snap On

-40 °C (-40 °F)

15 kA

Toggle

3.15 in (80 mm)

2.091 in (53.1 mm)

2.362 in (60 mm)

CCC; CSA; UL; VDE

3

75 °C (167 °F)

Short

M9F43208

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

MS14154-10L

Sensata Technologies

Thermal Circuit Breaker

Panel Mount-Threaded

120 V

10 A

Screw

2 kA

Push-Pull

1.84 in (46.73 mm)

0.781 in (19.84 mm)

Corrosion Resistant; Moisture Resistant

1.84 x 0.781 x 1.384 in (46.73 x 19.84 x 35.15 mm)

Trip Free

1.436 in (36.47 mm)

1

S201-D20NA

Abb

Thermal Magnetic Circuit Breaker

W58-XB1A4A-12

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

50 V

12 A

Quick Connect

1 kA

6 s

Push To Reset

1.375 in (34.93 mm)

0.66 in (16.76 mm)

Series Trip

1.375 in (34.93 mm)

1

2800837

Phoenix Contact

Thermal Circuit Breaker

2800837

2C5UL

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

5 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.146 in (105.3 mm)

1.378 in (35 mm)

Trip

2.693 in (68.4 mm)

CE, CUL, UL

2

55 °C (131 °F)

2CU5L

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

5 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.291 in (109 mm)

1.378 in (35 mm)

IP20

Trip

2.362 in (60 mm)

CE, CUL, UL

2

60 °C (140 °F)

4435.0044

Schurter Ag

Thermal Circuit Breaker

Panel Mount

415 V

5 A

Quick Connect

-30 °C (-22 °F)

2 kA

Rocker

Bulk

1.594 in (40.5 mm)

1.417 in (36 mm)

Manual On/Off

1.736 in (44.1 mm)

CCC; CUL; UL; VDE

3

60 °C (140 °F)

9-1423674-4

TE Connectivity

Thermal Circuit Breaker

AA1-B0-26-440-2B1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

4 A

Screw

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

AA1-B0-26-450-1D1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

5 A

Quick Connect

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

AA2-B0-10-625-1B1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

80 V

25 A

Quick Connect

-40 °C (-40 °F)

7.5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

1.515 in (38.48 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

2

85 °C (185 °F)

AA2-B0-26-410-1B1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

1 A

Quick Connect

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

1.515 in (38.48 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

2

85 °C (185 °F)

AB3-B0-26-475-3B1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

7.5 A

Screw

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2.265 in (57.53 mm)

2 in (50.8 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

3

85 °C (185 °F)

FAZ-C32/3

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

96 V

32 A

Snap On

-40 °C (-40 °F)

15 kA

Toggle

3.15 in (80 mm)

2.091 in (53.1 mm)

IP20

Manual On/Off

2.362 in (60 mm)

CCC; CE; CSA; IEC; UL; VDE

3

75 °C (167 °F)

Short

GV3P501

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

GV3P506

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail And Panel Mount

690 V

50 A

Screw And Snap On

-20 °C (-4 °F)

6 kA

Reference standard: UL

Rotary Handle

Bulk

5.197 in (132 mm)

2.165 in (55 mm)

IK09; IP20

Trip

5.354 in (136 mm)

ABS; ATEX; BV; CSA; CCC; DNV-GL; EAC; EN; IEC; LR0S; UKCA

3

60 °C (140 °F)

IEG11-1-62F-20.0-A-00

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

240 V

20 A

Quick Connect

-40 °C (-40 °F)

2 kA

Toggle Handle

2 in (50.8 mm)

1.515 in (38.48 mm)

Corrosion/Moisture Resistant

Trip Free

1.687 in (42.85 mm)

VDE

2

85 °C (185 °F)

M9F43203

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

MG24519

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

4 A

Snap On

-30 °C (-22 °F)

5 kA

Toggle

Bulk

3.189 in (81 mm)

1.417 in (36 mm)

IP20; IP40

Trip

2.874 in (73 mm)

CCC; CSA; IEC; UL

2

70 °C (158 °F)

S204M-B10

Abb

Thermal Magnetic Circuit Breaker

SU201M-Z13

Abb

Thermal Magnetic Circuit Breaker

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.