Circuit Breaker

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

W33-S1N1Q-5

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

50 V

5 A

Quick Connect

1 kA

3 s

Rocker

1.89 in (48.01 mm)

0.98 in (24.89 mm)

Series Trip

1.724 in (43.79 mm)

2

0700040

Phoenix Contact

Thermal Circuit Breaker

0700040

0903028

Phoenix Contact

Magnetic Circuit Breaker

DIN Rail Mount

6 A

Screw

0 °C (32 °F)

Bulk

3.15 in (80 mm)

0.492 in (12.5 mm)

IP20

3.268 in (83 mm)

CE, UL

50 °C (122 °F)

0915056

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

250 V

65 V

8 A

Snap On

-30 °C (-22 °F)

2 kA

Rated breaking capacity at 32 VDC: 2500 A

Lever

Bulk

3.78 in (96 mm)

0.984 in (25 mm)

IP20; IP30

Trip

3.248 in (82.5 mm)

CSA; EAC; UL; VDE

2

60 °C (140 °F)

0916612

Phoenix Contact

Thermal Magnetic Circuit Breaker

1020069

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

125 V

10 A

Snap On

-35 °C (-31 °F)

5 kA

Handle

Bulk

3.205 in (81.4 mm)

1.39 in (35.3 mm)

IP20

Trip

2.587 in (65.7 mm)

CUL; TUV; UL

2

70 °C (158 °F)

1410-L110-L1F1-S01-1A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Through Hole Mount

240 V

28 V

1 A

Printed Circuit Board

-20 °C (-4 °F)

Silver

2 kA

Rated breaking capacity at 50 VDC: 200 A, Environmental Characteristics: IP40; IP00

Reset Button

0.984 in (25 mm)

0.504 in (12.8 mm)

Corrosion Resistant; Moisture Resistant

e4

0.984 x 0.504 x 0.591 in (25 x 12.8 x 15 mm)

0.591 in (15 mm)

CSA; UL; VDE

1

70 °C (158 °F)

2CU3L

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

3 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.291 in (109 mm)

1.378 in (35 mm)

IP20

Trip

2.362 in (60 mm)

CE, CUL, UL

2

60 °C (140 °F)

3-101-228

Schurter Ag

Thermal Circuit Breaker

Through Hole Mount

240 V

48 V

4 A

Solder

-5 °C (23 °F)

2 kA

Reset Type

Bulk

0.748 in (19 mm)

0.575 in (14.6 mm)

IP40

Trip Free

1.421 in (36.1 mm)

CCC; CSA; GB; IEC; UL; VDE

1

60 °C (140 °F)

3B1UR

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

1 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle

Bulk

3.516 in (89.3 mm)

2.067 in (52.5 mm)

IP20

Trip

2.693 in (68.4 mm)

CE; CUL; UL

3

55 °C (131 °F)

3RV1041-4FA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

40 A

Screw And Snap On

-20 °C (-4 °F)

6 kA

Rotary Handle

6.496 in (165 mm)

2.756 in (70 mm)

IP20

6.496 x 2.756 x 6.85 in (165 x 70 x 174 mm)

Trip

6.85 in (174 mm)

3

60 °C (140 °F)

3RV2031-4UA15

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail And Panel Mount

690 V

40 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

Handle

5.512 in (140 mm)

2.165 in (55 mm)

IP00; IP20

5.512 x 2.165 x 5.882 in (140 x 55 x 149.4 mm)

Trip

5.882 in (149.4 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

Instantaneous

3RV2031-4VA15

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

45 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

Rotary Handle

5.512 in (140 mm)

2.165 in (55 mm)

IP00; IP20

5.512 x 2.165 x 5.866 in (140 x 55 x 149 mm)

Trip

5.866 in (149 mm)

3

60 °C (140 °F)

3RV2031-4WA15

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

52 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

Rotary Handle

5.512 in (140 mm)

2.165 in (55 mm)

IP00; IP20

5.512 x 2.165 x 5.866 in (140 x 55 x 149 mm)

Trip

5.866 in (149 mm)

3

60 °C (140 °F)

3RV2031-4XA15

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

59 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

Rotary Handle

5.512 in (140 mm)

2.165 in (55 mm)

IP00; IP20

5.512 x 2.165 x 5.866 in (140 x 55 x 149 mm)

Trip

5.866 in (149 mm)

3

60 °C (140 °F)

410215

Legrand

Thermal Magnetic Circuit Breaker

DIN Rail Mount

400 V

25 A

Snap On

-25 °C (-13 °F)

50 kA

Toggle Handle

Bulk

4.106 in (104.3 mm)

3.154 in (80.1 mm)

Manual On/Off

3.11 in (79 mm)

IEC

3

70 °C (158 °F)

4420.0237

Schurter Ag

Thermal Magnetic Circuit Breaker

483-G411-K1M1-A1S0ZN--10A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

28 V

10 A

Screw

-55 °C (-67 °F)

2.5 kA

Rated breaking capacity at 28 VDC: 6000 A

Push-Pull

0.768 in (19.5 mm)

0.559 in (14.2 mm)

IP40; IP00

0.768 x 0.559 x 1.22 in (19.5 x 14.2 x 31 mm)

Tease-Free And Trip-Free

1.22 in (31 mm)

1

125 °C (257 °F)

5SJ4106-6HG40

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

400 V

60 V

6 A

Snap On

-25 °C (-13 °F)

Interrupting current max: 14000 A as per UL/CSA

Handle

3.535 in (89.8 mm)

0.693 in (17.6 mm)

IP20; IP40; Sealed

3.535 x 0.693 x 3.031 in (89.8 x 17.6 x 77 mm)

Trip

3.031 in (77 mm)

CCC; CE; UL; VDE

1

55 °C (131 °F)

5SU1354-6KK10

Siemens

Equipment Leakage Circuit Breaker

DIN Rail Mount

230 V

10 A

Screw And Snap On

10 kA

Handle

3.543 in (90 mm)

1.417 in (36 mm)

IP20

3.543 x 1.417 x 3.031 in (90 x 36 x 77 mm)

Trip

3.031 in (77 mm)

2

70 °C (158 °F)

5SU1354-6KK16

Siemens

Thermal Circuit Breaker

Panel Mount

240 V

16 A

Screw

-25 °C (-13 °F)

10 kA

3.543 in (90 mm)

1.394 in (35.4 mm)

IP20

Trip

3 in (76.2 mm)

CCC; CE; IMQ; RCM; VDE

2

55 °C (131 °F)

6752-100-50

Sensata Technologies

Thermal Circuit Breaker

Panel Mount

120 V

28 V

50 A

Screw

3.5 kA

1 s

Rated breaking capacity at 28 VDC: 6000 A

Push-Pull

2.189 in (55.6 mm)

0.75 in (19.05 mm)

Corrosion/Moisture Resistant

2.189 x 0.75 x 1.93 in (55.6 x 19.05 x 49.02 mm)

Trip

1.93 in (49.02 mm)

1

787-1668

Wago

Equipment Leakage Circuit Breaker

A9N18597

Schneider Electric Sa

Equipment Leakage Circuit Breaker

AP17-1-61-203

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

240 V

20 A

Screw

-40 °C (-40 °F)

1 kA

Toggle

1.562 in (39.67 mm)

1.281 in (32.53 mm)

Corrosion Resistant; Sealed

Series Trip

1.78 in (45.21 mm)

2

100 °C (212 °F)

CA1-B2-16-435-1B1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

80 V

3.5 A

Stud

-40 °C (-40 °F)

7.5 kA

Handle

2.5 in (63.5 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.85 in (47 mm)

CSA; UL

1

85 °C (185 °F)

CA1-B2-16-435-AB1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

80 V

3.5 A

Stud

-40 °C (-40 °F)

7.5 kA

Handle

2.5 in (63.5 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.85 in (47 mm)

CSA; UL

1

85 °C (185 °F)

CLB-103-27E3A-W-A

Carling Technologies

Thermal Circuit Breaker

Panel Mount

250 V

32 V

10 A

Quick Connect

-10 °C (14 °F)

300 A

Rated breaking capacity at 32 VDC: 2500 A

Push To Reset

1.378 in (35 mm)

0.571 in (14.5 mm)

Fire Resistant

Series Trip

1.693 in (43 mm)

CE; TUV; UL

1

60 °C (140 °F)

CLB-103-27E3N-B-F

Carling Technologies

Thermal Circuit Breaker

Panel Mount

250 V

32 V

10 A

Screw

-10 °C (14 °F)

300 A

Rated breaking capacity at 32 VDC: 2500 A

Push To Reset

1.378 in (35 mm)

0.571 in (14.5 mm)

Fire Resistant

Series Trip

1.693 in (43 mm)

CE; TUV; UL

1

60 °C (140 °F)

CLB-103-27E3N-W-F

Carling Technologies

Thermal Circuit Breaker

Panel Mount

250 V

32 V

10 A

Screw

-10 °C (14 °F)

300 A

Rated breaking capacity at 32 VDC: 2500 A

Push To Reset

1.378 in (35 mm)

0.571 in (14.5 mm)

Fire Resistant

Series Trip

1.693 in (43 mm)

CE; TUV; UL

1

60 °C (140 °F)

CLB-103-27E6N-W-A

Carling Technologies

Thermal Circuit Breaker

Panel Mount

250 V

32 V

10 A

Quick Connect

-10 °C (14 °F)

300 A

Rated breaking capacity at 32 VDC: 2500 A

Push To Reset

1.378 in (35 mm)

0.571 in (14.5 mm)

Fire Resistant

Series Trip

1.693 in (43 mm)

CE; TUV; UL

1

60 °C (140 °F)

FAZ-D6/2

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

96 V

6 A

Snap On

-40 °C (-40 °F)

5 kA

Toggle

3.15 in (80 mm)

1.394 in (35.4 mm)

IP20

Trip Free

2.362 in (60 mm)

CSA; UL

2

167 °C (332.6 °F)

HGL36150

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

IEG11-1REC4-72-20.0-01-V

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

240 V

80 V

20 A

Quick Connect

-40 °C (-40 °F)

2 kA

Toggle Handle

2 in (50.8 mm)

1.515 in (38.48 mm)

Corrosion/Moisture Resistant

Trip Free

1.687 in (42.85 mm)

CCC; VDE

2

85 °C (185 °F)

M9F43205

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

MD1-B-34-610-1-A42-B-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

125 V

80 V

10 A

Quick Connect

-40 °C (-40 °F)

1 kA

Rocker

1.375 in (34.93 mm)

0.68 in (17.27 mm)

Chemical/Corrosion/Moisture Resistant

Series Trip

1.53 in (38.86 mm)

UL; CSA

1

85 °C (185 °F)

MS25361-50

Sensata Technologies

Thermal Circuit Breaker

Panel Mount

120 V

28 V

50 A

Screw

3.5 kA

Rated breaking capacity at 28 VDC: 6000 A

Push-Pull

2.189 in (55.6 mm)

0.75 in (19.05 mm)

Corrosion Resistant; Moisture Resistant

2.56 in (65.02 mm)

MIL-C-5809

1

MS26574-2A

Eaton Corporation

Thermal Circuit Breaker

Panel Mount-Threaded

120 V

28 V

2 A

Screw

800 A

Standard: MIL-C-5809

0.78 in (19.81 mm)

0.593 in (15.06 mm)

0.78 x 0.593 x 1.251 in (19.81 x 15.06 x 31.78 mm)

1.251 in (31.78 mm)

MS

1

PCB-B1-22-650-1AD-E12

Carling Technologies

Equipment Leakage Circuit Breaker

Panel Mount

240 V

50 A

Stud

-35 °C (-31 °F)

5 kA

Rocker

3.8 in (96.52 mm)

3.015 in (76.58 mm)

Moisture Resistant

Series Trip

2.975 in (75.57 mm)

UL

2

66 °C (150.8 °F)

S201-D16

Abb

Thermal Magnetic Circuit Breaker

S204M-C6

Abb

Thermal Magnetic Circuit Breaker

W58-XB1A4A-10

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

50 V

10 A

Quick Connect

1 kA

6 s

Rated breaking capacity at 50 VDC: 2000 A

Push To Reset

1.375 in (34.93 mm)

0.66 in (16.76 mm)

1.375 x 0.66 x 1.375 in (34.93 x 16.76 x 34.93 mm)

Series Trip

1.375 in (34.93 mm)

CSA; UL

1

W58-XC4C12A-1

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

50 V

1 A

Lug

1 kA

10 s

Push To Reset

1.375 in (34.93 mm)

0.66 in (16.76 mm)

Series Trip

1.375 in (34.93 mm)

1

W67-X2T52-50

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

65 V

50 A

Screw

2.2 s

Toggle

Series Trip

1

1492-SPM3D250

Rockwell Automation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

25 A

Snap On

-25 °C (-13 °F)

10 kA

Interrupting current max(DC): 10000 A

Toggle

3.465 in (88 mm)

2.087 in (53 mm)

IP20; IP40

Trip

2.913 in (74 mm)

CCC; CE; CSA; DNVGL; EN; GB; UL; VDE

3

55 °C (131 °F)

Fast

1492-SPM3D250N

Rockwell Automation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

25 A

Snap On

-25 °C (-13 °F)

10 kA

Interrupting current max(DC): 10000 A

Toggle

3.465 in (88 mm)

2.756 in (70 mm)

IP20; IP40

Trip

2.913 in (74 mm)

CCC; CE; CSA; DNVGL; EN; GB; UL; VDE

3

55 °C (131 °F)

Fast

167113

Eaton Corporation

Equipment Leakage Circuit Breaker

DIN Rail Mount

277 V

25 A

Snap On

-25 °C (-13 °F)

10 kA

3.15 in (80 mm)

2.756 in (70 mm)

IP20; IP40

Trip

2.579 in (65.5 mm)

EN; IEC; UL

2

55 °C (131 °F)

18639

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.