Circuit Breaker

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

1610-21-15A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Inline/Holder

32 V

15 A

Tab/Blade

-40 °C (-40 °F)

150 A

Push To Reset

0.787 in (20 mm)

0.236 in (6 mm)

Corrosion Resistant; IP00; IP30; IP54

Trip Free

0.945 in (24 mm)

UL

1

85 °C (185 °F)

1658-G21-02-P10-20A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Inline/Holder

240 V

28 V

20 A

Tab/Blade

-20 °C (-4 °F)

200 A

Manual Reset

1.26 in (32 mm)

0.551 in (14 mm)

Trip Free

1.563 in (39.7 mm)

CSA; CUL; UL; VDE

1

60 °C (140 °F)

243304

Eaton Corporation

Thermal Circuit Breaker

DIN Rail Mount

400 V

48 V

40 A

Snap On

-25 °C (-13 °F)

4.5 kA

Handle

Bulk

3.15 in (80 mm)

2.067 in (52.5 mm)

IP20

Trip

2.579 in (65.5 mm)

EN; IEC

3

75 °C (167 °F)

28600

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

2909910

Phoenix Contact

Thermal Circuit Breaker

2CDS251001R0161

Abb

Thermal Magnetic Circuit Breaker

2CDS251001R0971

Abb

Thermal Magnetic Circuit Breaker

2CDS251103R0161

Abb

Thermal Magnetic Circuit Breaker

2CDS272001R0105

Abb

Thermal Magnetic Circuit Breaker

2CSR255051R1325

Abb

Equipment Leakage Circuit Breaker

2CU10L

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

10 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.291 in (109 mm)

1.378 in (35 mm)

IP20

Trip

2.362 in (60 mm)

CE, CUL, UL

2

60 °C (140 °F)

2DU8L

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

8 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.291 in (109 mm)

1.378 in (35 mm)

IP20

Trip

2.362 in (60 mm)

CE, CUL, UL

2

60 °C (140 °F)

3120-F324-P7T1-W01D-10A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

250 V

50 V

10 A

Quick Connect

-30 °C (-22 °F)

100 A

Rocker

2.205 in (56 mm)

0.827 in (21 mm)

Corrosion Resistant

2.205 x 0.827 x 1.299 in (56 x 21 x 33 mm)

Manual On/Off

1.299 in (33 mm)

CCC; CSA; UL; VDE

2

60 °C (140 °F)

3120-N311-P7T1-W01D-20A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

20 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

2.22 in (56.4 mm)

0.984 in (25 mm)

Corrosion Resistant; IP00; IP40

Trip Free

1.299 in (33 mm)

CCC; CSA; KC; UL; VDE

1

60 °C (140 °F)

3120-N311-P7T1-W02D-15A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

15 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

2.22 in (56.4 mm)

0.984 in (25 mm)

Corrosion Resistant; IP00; IP40

Trip Free

1.299 in (33 mm)

CCC; CSA; KC; UL; VDE

1

60 °C (140 °F)

3120-N311-P7T1-W02D-5A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

5 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

2.22 in (56.4 mm)

0.984 in (25 mm)

Corrosion Resistant; IP00; IP40

Trip Free

1.299 in (33 mm)

CCC; CSA; KC; UL; VDE

1

60 °C (140 °F)

3120-N321-P7T1-W01D-15A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

3120-N321-P7T1-W02D-15A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

15 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

2.22 in (56.4 mm)

0.984 in (25 mm)

Corrosion Resistant; IP00; IP40

Trip Free

1.299 in (33 mm)

CCC; CSA; KC; UL; VDE

2

60 °C (140 °F)

3120-N323-P7T1-W01D-15A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

15 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

2.22 in (56.4 mm)

0.984 in (25 mm)

Corrosion Resistant; IP00; IP40

Trip Free

1.299 in (33 mm)

CCC; CSA; KC; UL; VDE

2

60 °C (140 °F)

3120-N323-P7T1-W02D-15A

E-t-a Elektrotechnische Apparate

Thermal Magnetic Circuit Breaker

3120-N324-P7T1-W19DG3-20A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

20 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

Corrosion Resistant; IP00; IP40

Manual On/Off

CCC; CE; CSA; CQC; KTL; UKCA; UL; VDE

2

60 °C (140 °F)

3120-N32A-H7T1-W12LY4-2A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

230 V

2 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

Corrosion Resistant; IP00; IP40

Manual On/Off

CCC; CE; CSA; CQC; KTL; UKCA; UL; VDE

2

60 °C (140 °F)

3RV1011-0GA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

630 mA

Snap On

-20 °C (-4 °F)

100 kA

Interrupting current max at 450 VDC: 10000 A

Rocker

3.543 in (90 mm)

1.772 in (45 mm)

IP20

3.543 x 1.772 x 2.953 in (90 x 45 x 75 mm)

Trip

2.953 in (75 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; UL; VDE

3

60 °C (140 °F)

3RV1031-4HA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

50 A

Snap On

-20 °C (-4 °F)

4 kA

5.512 in (140 mm)

2.165 in (55 mm)

IP20

5.512 x 2.165 x 5.866 in (140 x 55 x 149 mm)

Trip

5.866 in (149 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; UL; VDE

3

60 °C (140 °F)

3RV2011-1DA20

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

3.2 A

Snap On

-20 °C (-4 °F)

10 kA

Interrupting current max at 450 VDC: 10000 A

Handle

4.173 in (106 mm)

1.772 in (45 mm)

IP20

4.173 x 1.772 x 3.815 in (106 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

3RV2011-1GA20

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

6.3 A

Snap On

-20 °C (-4 °F)

4 kA

Handle

4.173 in (106 mm)

1.772 in (45 mm)

IP20

4.173 x 1.772 x 3.815 in (106 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

Instantaneous

3RV2021-1BA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

2 A

Snap On

-20 °C (-4 °F)

10 kA

Interrupting current max at 450 VDC: 10000 A

Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

Instantaneous

412-K14-N2-7.5A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

28 V

7.5 A

Screw

-55 °C (-67 °F)

6 kA

Push-Pull

1.142 in (29 mm)

0.571 in (14.5 mm)

Corrosion/Moisture Resistant; IP00; IP40

Trip Free

1.811 in (46 mm)

CSA; UL

1

75 °C (167 °F)

413-K14-LN2-60A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

28 V

60 A

Screw

-55 °C (-67 °F)

6 kA

Push-Pull

1.26 in (32 mm)

0.748 in (19 mm)

Corrosion/Moisture Resistant; IP00; IP40

Tease-Free And Trip-Free

1.929 in (49 mm)

CSA; UL

1

75 °C (167 °F)

413-K54-N2-70A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

28 V

70 A

Screw

-55 °C (-67 °F)

6 kA

Push-Pull

1.26 in (32 mm)

0.748 in (19 mm)

Corrosion/Moisture Resistant; IP00; IP40

Trip Free

1.929 in (49 mm)

CSA; UL

1

75 °C (167 °F)

4130-G211-K4M1-50A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

50 A

Screw

-30 °C (-22 °F)

800 A

Push To Reset

1.26 in (32 mm)

0.709 in (18 mm)

Corrosion Resistant; IP00; IP40

1.26 x 0.709 x 1.969 in (32 x 18 x 50 mm)

Tease-Free And Trip-Free

1.969 in (50 mm)

CBE; CSA; EN; IEC; UL; VDE

1

60 °C (140 °F)

Medium

422142

Legrand

Thermal Magnetic Circuit Breaker

Panel Mount

400 V

320 A

Screw

-25 °C (-13 °F)

36 kA

Toggle Handle

Bulk

10.236 in (260 mm)

7.205 in (183 mm)

Trip

5.669 in (144 mm)

IEC

4

70 °C (158 °F)

4230-T130-K0CE-15A

E-t-a Elektrotechnische Apparate

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

15 A

Snap On

-35 °C (-31 °F)

5 kA

Toggle Handle

3.228 in (82 mm)

2.083 in (52.9 mm)

Corrosion Resistant; IP20

Trip Free

2.37 in (60.2 mm)

UL; TUV

3

70 °C (158 °F)

423027

Legrand

Thermal Magnetic Circuit Breaker

Panel Mount

400 V

250 A

Screw

-25 °C (-13 °F)

36 kA

Toggle Handle

Bulk

6.496 in (165 mm)

5.512 in (140 mm)

Trip

4.409 in (112 mm)

IEC

4

70 °C (158 °F)

423052

Legrand

Thermal Magnetic Circuit Breaker

Panel Mount

400 V

80 A

Screw

-25 °C (-13 °F)

36 kA

Toggle Handle

Bulk

6.496 in (165 mm)

5.512 in (140 mm)

Trip

4.409 in (112 mm)

IEC

4

70 °C (158 °F)

4400.0010

Schurter Ag

Thermal Circuit Breaker

Panel Mount-Threaded

240 V

48 V

3 A

Quick Connect

-5 °C (23 °F)

2 kA

Reset Button

Bulk

0.748 in (19 mm)

0.433 in (11 mm)

IP40

Trip Free

1.976 in (50.2 mm)

CCC; CSA; IEC; UL; VDE; GB

1

60 °C (140 °F)

482-G111-K1M1-A1S1-50A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

28 V

50 A

Screw

-55 °C (-67 °F)

5 kA

Push Button

1.22 in (31 mm)

0.709 in (18 mm)

Corrosion/Moisture Resistant; IP00; IP40

Trip Free

1.89 in (48 mm)

BW; CSA; UL

1

75 °C (167 °F)

482-G111-K1M1-A1S1-5A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

28 V

5 A

Screw

-55 °C (-67 °F)

5 kA

Push Button

1.22 in (31 mm)

0.709 in (18 mm)

Corrosion/Moisture Resistant; IP00; IP40

Trip Free

1.89 in (48 mm)

BW; CSA; UL

1

75 °C (167 °F)

483-G411-K1M1-A1S0Z--5A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

28 V

5 A

Screw

-55 °C (-67 °F)

2 kA

Rated breaking capacity at 28 VDC: 6000 A

Push-Pull

0.768 in (19.5 mm)

0.559 in (14.2 mm)

IP40; IP00

Tease-Free And Trip-Free

1.22 in (31 mm)

1

125 °C (257 °F)

5SU1356-7KK13

Siemens

Equipment Leakage Circuit Breaker

DIN Rail Mount

230 V

13 A

Screw And Snap On

6 kA

Handle

3.543 in (90 mm)

1.417 in (36 mm)

IP20

3.543 x 1.417 x 3.031 in (90 x 36 x 77 mm)

Trip

3.031 in (77 mm)

2

70 °C (158 °F)

5SU1654-7KK16

Siemens

Equipment Leakage Circuit Breaker

DIN Rail Mount

230 V

16 A

Screw And Snap On

10 kA

Handle

3.543 in (90 mm)

1.417 in (36 mm)

IP20

3.543 x 1.417 x 3.031 in (90 x 36 x 77 mm)

Trip

3.031 in (77 mm)

2

70 °C (158 °F)

5SV3314-6

Siemens

Equipment Leakage Circuit Breaker

DIN Rail Mount

230 V

40 A

Screw And Snap On

10 kA

Handle

3.543 in (90 mm)

1.417 in (36 mm)

IP20

3.543 x 1.417 x 2.756 in (90 x 36 x 70 mm)

Trip

2.756 in (70 mm)

2

70 °C (158 °F)

5SV3314-6KK01

Siemens

Equipment Leakage Circuit Breaker

DIN Rail Mount

230 V

40 A

Screw And Snap On

10 kA

Handle

3.543 in (90 mm)

1.417 in (36 mm)

IP20

3.543 x 1.417 x 2.756 in (90 x 36 x 70 mm)

Trip

2.756 in (70 mm)

2

70 °C (158 °F)

5SY4103-8

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

3 A

Snap On

-25 °C (-13 °F)

5 kA

Handle

3.543 in (90 mm)

0.709 in (18 mm)

3.543 x 0.709 x 2.992 in (90 x 18 x 76 mm)

Trip

2.992 in (76 mm)

CE; CSA; EN; UL

1

45 °C (113 °F)

5SY4206-8

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

400 V

6 A

Snap On

10 kA

3.535 in (89.8 mm)

1.386 in (35.2 mm)

IP20

3.535 x 1.386 x 2.992 in (89.8 x 35.2 x 76 mm)

Trip

2.992 in (76 mm)

CCC; CE; IMQ; RCM; UL; VDE

2

7274-4-21/2

Sensata Technologies

Thermal Circuit Breaker

7274-4

9-1393253-2

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

30 A

Quick Connect

2.2 s

Toggle

Series Trip

3

9-1393254-7

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

30 A

Stud

-40 °C (-40 °F)

5 kA

9 s

Toggle

2.5 in (63.5 mm)

2.25 in (57.15 mm)

Series Trip

1.845 in (46.86 mm)

3

85 °C (185 °F)

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.