Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Actuator Type | Packing Method | Body Length/Diameter | Body Width | Environmental Characteristics | JESD-609 Code | Dimensions | Circuit Function | Body Height | Reference Standard | No. of Poles | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
80 V |
20 A |
Screw |
-40 °C (-40 °F) |
3 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Rocker |
2.156 in (54.76 mm) |
1.515 in (38.48 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL; VDE |
2 |
85 °C (185 °F) |
|||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
80 V |
10 A |
Screw |
-40 °C (-40 °F) |
7.5 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Rocker |
2.156 in (54.76 mm) |
1.515 in (38.48 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL |
2 |
85 °C (185 °F) |
|||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
10 A |
Screw |
-40 °C (-40 °F) |
5 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Rocker |
2.156 in (54.76 mm) |
1.515 in (38.48 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL |
2 |
85 °C (185 °F) |
|||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
250 V |
10 A |
Screw |
-40 °C (-40 °F) |
1 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Rocker |
2.156 in (54.76 mm) |
0.745 in (18.92 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL; VDE |
1 |
85 °C (185 °F) |
|||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
250 V |
80 V |
1 A |
Quick Connect |
-40 °C (-40 °F) |
1 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Rocker |
2.156 in (54.76 mm) |
0.745 in (18.92 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL; VDE |
1 |
85 °C (185 °F) |
||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
80 V |
10 A |
Screw |
-40 °C (-40 °F) |
7.5 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Toggle |
2 in (50.8 mm) |
1.49 in (37.85 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.817 in (46.15 mm) |
CSA; UL |
2 |
85 °C (185 °F) |
|||||||||
Sensata Technologies |
Magnetic Circuit Breaker |
Panel Mount |
240 V |
50 V |
12 A |
Solder Hook |
-40 °C (-40 °F) |
1 kA |
Toggle Handle |
1.562 in (39.67 mm) |
1.281 in (32.53 mm) |
Sealed |
Series Trip |
1.78 in (45.21 mm) |
UL |
2 |
100 °C (212 °F) |
||||||||||
Sensata Technologies |
Magnetic Circuit Breaker |
Panel Mount |
240 V |
50 V |
3 A |
Solder Hook |
-40 °C (-40 °F) |
1 kA |
Toggle Handle |
1.562 in (39.67 mm) |
1.281 in (32.53 mm) |
Sealed |
Series Trip |
1.78 in (45.21 mm) |
UL |
2 |
100 °C (212 °F) |
||||||||||
Sensata Technologies |
Magnetic Circuit Breaker |
Panel Mount |
240 V |
50 V |
3 A |
Solder Hook |
-40 °C (-40 °F) |
1 kA |
Toggle |
1.562 in (39.67 mm) |
1.281 in (32.53 mm) |
Corrosion Resistant; Sealed |
Series Trip |
1.78 in (45.21 mm) |
2 |
100 °C (212 °F) |
|||||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
10 A |
Screw |
-40 °C (-40 °F) |
1.5 kA |
Toggle Handle |
2 in (50.8 mm) |
2.265 in (57.53 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.73 in (43.94 mm) |
CSA; UL; VDE |
3 |
85 °C (185 °F) |
|||||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
80 V |
30 A |
Stud |
-40 °C (-40 °F) |
7.5 kA |
Rocker |
2.5 in (63.5 mm) |
0.755 in (19.18 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.85 in (47 mm) |
CSA; TUV; UL |
1 |
85 °C (185 °F) |
|||||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
250 V |
100 mA |
Stud |
-40 °C (-40 °F) |
5 kA |
Handle |
2.5 in (63.5 mm) |
0.755 in (19.18 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.85 in (47 mm) |
CSA; UL; VDE |
1 |
85 °C (185 °F) |
|||||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
480 V |
150 V |
1 A |
Stud |
-40 °C (-40 °F) |
10 kA |
Handle |
1.85 in (47 mm) |
0.75 in (19.05 mm) |
Series Trip |
2.5 in (63.5 mm) |
UL |
1 |
85 °C (185 °F) |
|||||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
480 V |
150 V |
100 A |
Stud |
-40 °C (-40 °F) |
10 kA |
Handle |
1.85 in (47 mm) |
0.75 in (19.05 mm) |
Series Trip |
2.5 in (63.5 mm) |
UL |
1 |
85 °C (185 °F) |
|||||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
250 V |
80 V |
15 A |
Stud |
-40 °C (-40 °F) |
5 kA |
Handle |
2.5 in (63.5 mm) |
0.755 in (19.18 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.85 in (47 mm) |
CSA; UL; VDE |
1 |
85 °C (185 °F) |
||||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
480 V |
150 V |
15 A |
Stud |
-40 °C (-40 °F) |
10 kA |
Handle |
1.85 in (47 mm) |
1.515 in (38.48 mm) |
Series Trip |
2.5 in (63.5 mm) |
UL |
2 |
85 °C (185 °F) |
|||||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
480 V |
150 V |
15 A |
Stud |
-40 °C (-40 °F) |
10 kA |
Handle |
1.85 in (47 mm) |
1.515 in (38.48 mm) |
Series Trip |
2.5 in (63.5 mm) |
UL |
2 |
85 °C (185 °F) |
|||||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
80 V |
250 A |
Stud |
-40 °C (-40 °F) |
10 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Handle |
2.563 in (65.1 mm) |
2.265 in (57.53 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.85 in (47 mm) |
UL |
3 |
85 °C (185 °F) |
|||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
80 V |
225 A |
Stud |
-40 °C (-40 °F) |
10 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Handle |
2.563 in (65.1 mm) |
2.265 in (57.53 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.85 in (47 mm) |
UL |
3 |
85 °C (185 °F) |
|||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
250 V |
15 A |
Stud |
-40 °C (-40 °F) |
3 kA |
Handle |
2.5 in (63.5 mm) |
3.015 in (76.58 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.85 in (47 mm) |
CSA, UL, VDE |
4 |
85 °C (185 °F) |
|||||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
250 V |
70 A |
Stud |
-40 °C (-40 °F) |
Toggle Handle |
2.5 in (63.5 mm) |
2.24 in (56.9 mm) |
Corrosion/Moisture Resistant |
Switch |
1.85 in (47 mm) |
CSA, UL |
3 |
85 °C (185 °F) |
||||||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
125 V |
10 A |
Stud |
-40 °C (-40 °F) |
5 kA |
Handle |
2.5 in (63.5 mm) |
0.755 in (19.18 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.85 in (47 mm) |
CSA; UL |
1 |
85 °C (185 °F) |
|||||||||||
|
Carling Technologies |
Thermal Circuit Breaker |
Panel Mount |
250 V |
50 V |
15 A |
Quick Connect |
1 kA |
Rocker |
0.76 in (19.31 mm) |
0.76 in (19.31 mm) |
Series Trip |
1.535 in (38.99 mm) |
CE; CUL; UL; VDE |
1 |
||||||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
410 V |
20 A |
Screw |
-40 °C (-40 °F) |
10 kA |
Handle |
3.672 in (93.26 mm) |
1.515 in (38.48 mm) |
Corrosion/Moisture Resistant |
Series Trip |
2.264 in (57.51 mm) |
UL |
2 |
85 °C (185 °F) |
||||||||||
Altech |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
250 V |
15 A |
Snap On |
-25 °C (-13 °F) |
10 kA |
Toggle Handle |
Bulk |
4.291 in (109 mm) |
1.378 in (35 mm) |
IP20 |
Trip |
2.362 in (60 mm) |
CE, CUL, UL |
2 |
60 °C (140 °F) |
||||||||||
Altech |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
250 V |
25 A |
Snap On |
-25 °C (-13 °F) |
10 kA |
Toggle Handle |
Bulk |
4.291 in (109 mm) |
1.378 in (35 mm) |
IP20 |
Trip |
2.362 in (60 mm) |
CE, CUL, UL |
2 |
60 °C (140 °F) |
||||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
125 V |
70 A |
Stud |
-40 °C (-40 °F) |
5 kA |
Handle |
5.78 in (146.81 mm) |
1.026 in (26.06 mm) |
Corrosion/Moisture Resistant |
Series Trip |
2.61 in (66.3 mm) |
CSA; UL |
1 |
85 °C (185 °F) |
|||||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
125 V |
70 A |
Stud |
-40 °C (-40 °F) |
5 kA |
Handle |
5.78 in (146.81 mm) |
1.026 in (26.06 mm) |
Corrosion/Moisture Resistant |
Series Trip |
2.61 in (66.3 mm) |
CSA; UL |
1 |
85 °C (185 °F) |
||||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
125 V |
70 A |
Stud |
-40 °C (-40 °F) |
5 kA |
Handle |
5.78 in (146.81 mm) |
1.026 in (26.06 mm) |
Corrosion/Moisture Resistant |
Series Trip |
2.61 in (66.3 mm) |
CSA; UL; VDE |
1 |
85 °C (185 °F) |
||||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
240 V |
50 A |
Stud |
-40 °C (-40 °F) |
5 kA |
Handle |
5.78 in (146.81 mm) |
3.138 in (79.7 mm) |
Corrosion/Moisture Resistant |
Series Trip |
2.61 in (66.3 mm) |
CSA; UL |
3 |
85 °C (185 °F) |
||||||||||
Eaton Corporation |
Thermal Magnetic Circuit Breaker |
Panel Mount |
347 V |
40 A |
Screw |
18 kA |
Toggle Handle |
5.5 in (139.7 mm) |
3 in (76.2 mm) |
Manual On/Off |
2.992 in (76 mm) |
CE; CSA; IEC; UL |
3 |
||||||||||||||
Eaton Corporation |
Thermal Magnetic Circuit Breaker |
Panel Mount |
347 V |
50 A |
Screw |
18 kA |
Toggle Handle |
5.5 in (139.7 mm) |
3 in (76.2 mm) |
Manual On/Off |
2.992 in (76 mm) |
CE; CSA; IEC; UL |
3 |
||||||||||||||
Eaton Corporation |
Thermal Magnetic Circuit Breaker |
Panel Mount |
347 V |
70 A |
Screw |
18 kA |
Toggle Handle |
5.5 in (139.7 mm) |
3 in (76.2 mm) |
Manual On/Off |
2.992 in (76 mm) |
CE; CSA; IEC; UL |
3 |
||||||||||||||
Eaton Corporation |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
240 V |
1.5 A |
Snap On |
10 kA |
Toggle |
Manual On/Off |
2 |
||||||||||||||||||
|
Eaton Corporation |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
277 V |
10 A |
Snap On |
10 kA |
Toggle |
Manual On/Off |
2 |
|||||||||||||||||
Eaton Corporation |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
240 V |
15 A |
Snap On |
10 kA |
Toggle |
Manual On/Off |
2 |
||||||||||||||||||
|
Eaton Corporation |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
15 A |
Snap On |
-25 °C (-13 °F) |
14 kA |
Toggle |
4.134 in (105 mm) |
2.091 in (53.1 mm) |
Trip Free |
1.772 in (45 mm) |
CSA; UL |
3 |
75 °C (167 °F) |
|||||||||||
|
Eaton Corporation |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
20 A |
Snap On |
-40 °C (-40 °F) |
15 kA |
Toggle |
3.15 in (80 mm) |
2.091 in (53.1 mm) |
2.362 in (60 mm) |
CCC; CSA; UL; VDE |
3 |
75 °C (167 °F) |
Short |
|||||||||||
|
Eaton Corporation |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
96 V |
3 A |
Snap On |
-40 °C (-40 °F) |
15 kA |
Toggle |
3.15 in (80 mm) |
2.091 in (53.1 mm) |
IP20 |
Manual On/Off |
2.362 in (60 mm) |
CCC; CE; CSA; IEC; UL; VDE |
3 |
75 °C (167 °F) |
Short |
||||||||
|
Eaton Corporation |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
277 V |
48 V |
5 A |
Snap On |
-25 °C (-13 °F) |
15 kA |
Rated breaking capacity at 400 VAC |
IP20; IP40 |
Trip |
CE; CSA; EN; IEC; UL |
1 |
75 °C (167 °F) |
||||||||||||
|
Eaton Corporation |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
60 V |
20 A |
Snap On |
-25 °C (-13 °F) |
15 kA |
Manual On/Off |
4.134 in (105 mm) |
2.091 in (53.1 mm) |
IP20; IP40 |
Trip |
2.972 in (75.5 mm) |
CSA; EN; IEC; UL |
3 |
75 °C (167 °F) |
|||||||||
|
Schneider Electric Sa |
Thermal Circuit Breaker |
|||||||||||||||||||||||||
Carling Technologies |
Magnetic Circuit Breaker |
DIN Rail Mount |
80 V |
63 A |
Snap On |
-40 °C (-40 °F) |
3 kA |
Handle |
4.188 in (106.38 mm) |
1.376 in (34.95 mm) |
Corrosion/Moisture Resistant |
Series Trip |
2.62 in (66.55 mm) |
CSA, UL |
2 |
85 °C (185 °F) |
|||||||||||
|
Schneider Electric Sa |
Thermal Magnetic Circuit Breaker |
|||||||||||||||||||||||||
|
Schneider Electric Sa |
Thermal Magnetic Circuit Breaker |
DIN Rail And Panel Mount |
690 V |
1 A |
Screw And Snap On |
-20 °C (-4 °F) |
100 kA |
Push Button |
Bulk |
3.976 in (101 mm) |
1.772 in (45 mm) |
IK04; IP20 |
Trip |
3.091 in (78.5 mm) |
EN; IEC |
3 |
60 °C (140 °F) |
|||||||||
|
Schneider Electric Sa |
Thermal Magnetic Circuit Breaker |
|||||||||||||||||||||||||
|
Schneider Electric Sa |
Thermal Magnetic Circuit Breaker |
|||||||||||||||||||||||||
|
Schneider Electric Sa |
Thermal Magnetic Circuit Breaker |
DIN Rail And Panel Mount |
690 V |
14 A |
Screw And Snap On |
-20 °C (-4 °F) |
3 kA |
Push Button |
Bulk |
3.976 in (101 mm) |
1.772 in (45 mm) |
IK04; IP20 |
3.976 x 1.752 x 2.646 in (101 x 44.5 x 67.2 mm) |
Trip |
3.091 in (78.5 mm) |
ATEX; BV; CCC; CSA; DNV-GL; EAC; EN; IEC; LROS; RINA; UL |
3 |
60 °C (140 °F) |
A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.
Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.
In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.