Circuit Breaker

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

3RV2341-4JC10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

63 A

Screw And Snap On

-20 °C (-4 °F)

3 kA

Rotary Handle

6.496 in (165 mm)

2.756 in (70 mm)

IP00; IP20

6.496 x 2.756 x 6.929 in (165 x 70 x 176 mm)

Trip

6.929 in (176 mm)

3

60 °C (140 °F)

3VA6210-5HM31-2AA0

Siemens

Thermal Circuit Breaker

Panel Mount

600 V

100 A

Screw

-25 °C (-13 °F)

35 kA

Toggle

7.8 in (198.12 mm)

4.1 in (104.14 mm)

IP40

7.8 x 4.1 x 3.4 in (198.12 x 104.14 x 86.36 mm)

Trip

3.4 in (86.36 mm)

3

70 °C (158 °F)

3VL2706-3SP33-0AA0

Siemens

Thermal Circuit Breaker

Panel Mount

690 V

500 V

63 A

Box

-25 °C (-13 °F)

100 kA

Toggle

6.87 in (174.5 mm)

4.114 in (104.5 mm)

IP20

6.87 x 4.114 x 4.193 in (174.5 x 104.5 x 106.5 mm)

Trip

4.193 in (106.5 mm)

3

70 °C (158 °F)

4-1393248-7

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

50 V

10 A

Quick Connect

1 kA

3 s

Rocker

1.89 in (48.01 mm)

0.98 in (24.89 mm)

Series Trip

1.724 in (43.79 mm)

2

410202

Legrand

Thermal Magnetic Circuit Breaker

DIN Rail Mount

400 V

25 A

Snap On

-25 °C (-13 °F)

50 kA

Toggle Handle

Bulk

4.106 in (104.3 mm)

2.102 in (53.4 mm)

Manual On/Off

3.11 in (79 mm)

IEC

2

70 °C (158 °F)

413-K14-LN2-45A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

28 V

45 A

Screw

-55 °C (-67 °F)

6 kA

Push-Pull

1.26 in (32 mm)

0.748 in (19 mm)

Corrosion/Moisture Resistant; IP00; IP40

Tease-Free And Trip-Free

1.929 in (49 mm)

CSA; UL

1

75 °C (167 °F)

413-K14-LN2-80A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

28 V

80 A

Screw

-55 °C (-67 °F)

6 kA

Push-Pull

1.26 in (32 mm)

0.748 in (19 mm)

Corrosion/Moisture Resistant; IP00; IP40

Tease-Free And Trip-Free

1.929 in (49 mm)

CSA; UL

1

75 °C (167 °F)

413-K54-N2-60A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

28 V

60 A

Screw

-55 °C (-67 °F)

6 kA

Push-Pull

1.26 in (32 mm)

0.748 in (19 mm)

Corrosion/Moisture Resistant; IP00; IP40

Trip Free

1.929 in (49 mm)

CSA; UL

1

75 °C (167 °F)

420372

Legrand

Thermal Circuit Breaker

DIN Rail Mount

400 V

40 A

Snap On

-25 °C (-13 °F)

50 kA

Handle

Bulk

6.496 in (165 mm)

5.512 in (140 mm)

Trip

3.937 in (100 mm)

IEC

4

70 °C (158 °F)

422191

Legrand

Thermal Magnetic Circuit Breaker

Panel Mount

400 V

250 A

Screw

-25 °C (-13 °F)

50 kA

Toggle Handle

Bulk

10.236 in (260 mm)

7.205 in (183 mm)

Trip

5.669 in (144 mm)

IEC

4

70 °C (158 °F)

4411.0010

Schurter Ag

Thermal Circuit Breaker

Panel Mount

277 V

28 V

20 A

Quick Connect

-5 °C (23 °F)

1 kA

Reset Type

Bulk

1.22 in (31 mm)

0.453 in (11.5 mm)

IP40

Trip Free

1.772 in (45 mm)

CCC; CSA; GB; IEC; UL; VDE

1

60 °C (140 °F)

4435.0022

Schurter Ag

Thermal Circuit Breaker

Panel Mount

240 V

60 V

3 A

Quick Connect

-30 °C (-22 °F)

2 kA

Rocker

Bulk

1.417 in (36 mm)

1.142 in (29 mm)

IP40

Trip Free

1.736 in (44.1 mm)

CCC; CSA; GB; IEC; UL; VDE

2

60 °C (140 °F)

4435.0195

Schurter Ag

Thermal Circuit Breaker

Panel Mount

240 V

60 V

10 A

Quick Connect

-30 °C (-22 °F)

2 kA

Rocker

Bulk

1.417 in (36 mm)

1.142 in (29 mm)

IP40

Trip Free

1.736 in (44.1 mm)

CCC; CSA; GB; IEC; UL; VDE

2

60 °C (140 °F)

482-G111-K1M1-A1S0-50A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

72 V

50 A

Screw

-55 °C (-67 °F)

5 kA

Push-Pull

1.22 in (31 mm)

0.709 in (18 mm)

Corrosion/Moisture Resistant; IP00; IP40

Trip Free

1.969 in (50 mm)

CSA; CUL; UL

1

75 °C (167 °F)

483-G411-K1M1-A1S0ZN--20A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

28 V

20 A

Screw

-55 °C (-67 °F)

2.5 kA

Rated breaking capacity at 28 VDC: 6000 A

Push-Pull

0.768 in (19.5 mm)

0.559 in (14.2 mm)

IP40; IP00

Tease-Free And Trip-Free

1.22 in (31 mm)

1

125 °C (257 °F)

5SJ4320-7HG41

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

125 V

20 A

Screw And Snap On

14 kA

Handle

3.543 in (90 mm)

2.126 in (54 mm)

IP20; IP40

3.543 x 2.126 x 2.992 in (90 x 54 x 76 mm)

Trip

2.992 in (76 mm)

3

5SJ4335-7HG41

Siemens

Equipment Leakage Circuit Breaker

-25 °C (-13 °F)

55 °C (131 °F)

5SL6110-7

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

60 V

10 A

Snap On

-25 °C (-13 °F)

6 kA

3.543 in (90 mm)

0.709 in (18 mm)

IP20; Sealed

3.543 x 0.709 x 2.992 in (90 x 18 x 76 mm)

Trip

2.992 in (76 mm)

CE; CEBEC; TSE; VDE

1

45 °C (113 °F)

5SU1354-6KK25

Siemens

Equipment Leakage Circuit Breaker

DIN Rail Mount

230 V

25 A

Screw And Snap On

10 kA

Handle

3.543 in (90 mm)

1.417 in (36 mm)

IP20

3.543 x 1.417 x 3.031 in (90 x 36 x 77 mm)

Trip

3.031 in (77 mm)

2

70 °C (158 °F)

5SU1354-7KK10

Siemens

Equipment Leakage Circuit Breaker

DIN Rail Mount

230 V

10 A

Screw And Snap On

10 kA

Handle

3.543 in (90 mm)

1.417 in (36 mm)

IP20

3.543 x 1.417 x 3.031 in (90 x 36 x 77 mm)

Trip

3.031 in (77 mm)

2

70 °C (158 °F)

5SU1354-7KK13

Siemens

Equipment Leakage Circuit Breaker

DIN Rail Mount

230 V

13 A

Snap On

-25 °C (-13 °F)

10 kA

Bulk

3.543 in (90 mm)

1.417 in (36 mm)

IP20

Trip

3.031 in (77 mm)

CCC; CE; IMQ; RCM; VDE

2

55 °C (131 °F)

5SU1354-7KK32

Siemens

Equipment Leakage Circuit Breaker

DIN Rail Mount

230 V

32 A

Screw And Snap On

10 kA

Handle

3.543 in (90 mm)

1.417 in (36 mm)

IP20

3.543 x 1.417 x 3.031 in (90 x 36 x 77 mm)

Trip

3.031 in (77 mm)

2

70 °C (158 °F)

5SU1356-6KK13

Siemens

Equipment Leakage Circuit Breaker

DIN Rail Mount

230 V

13 A

Screw And Snap On

6 kA

Handle

3.543 in (90 mm)

1.417 in (36 mm)

IP20

3.543 x 1.417 x 3.031 in (90 x 36 x 77 mm)

Trip

3.031 in (77 mm)

2

70 °C (158 °F)

5SU1356-6KK25

Siemens

Equipment Leakage Circuit Breaker

DIN Rail Mount

230 V

25 A

Screw And Snap On

6 kA

Handle

3.543 in (90 mm)

1.417 in (36 mm)

IP20

3.543 x 1.417 x 3.031 in (90 x 36 x 77 mm)

Trip

3.031 in (77 mm)

2

70 °C (158 °F)

5SV3344-6KL

Siemens

Equipment Leakage Circuit Breaker

DIN Rail Mount

400 V

40 A

Screw And Snap On

10 kA

Handle

3.543 in (90 mm)

2.835 in (72 mm)

IP20

3.543 x 2.835 x 2.756 in (90 x 72 x 70 mm)

Trip

2.756 in (70 mm)

4

70 °C (158 °F)

5SV4312-0

Siemens

Equipment Leakage Circuit Breaker

DIN Rail Mount

230 V

25 A

Snap On

-25 °C (-13 °F)

10 kA

3.535 in (89.8 mm)

1.409 in (35.8 mm)

IP20

3.535 x 1.409 x 2.764 in (89.8 x 35.8 x 70.2 mm)

Trip

2.764 in (70.2 mm)

CCC; CE; IMQ

2

45 °C (113 °F)

Instantaneous

5SY4110-8

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

10 A

Snap On

-25 °C (-13 °F)

5 kA

Handle

3.543 in (90 mm)

0.709 in (18 mm)

3.543 x 0.709 x 2.992 in (90 x 18 x 76 mm)

Trip

2.992 in (76 mm)

CE; CSA; EN; UL

1

45 °C (113 °F)

5SY4363-6

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

400 V

63 A

Snap On

10 kA

3.535 in (89.8 mm)

2.079 in (52.8 mm)

IP20

3.535 x 2.079 x 2.992 in (89.8 x 52.8 x 76 mm)

Trip

2.992 in (76 mm)

CCC; CE; IMQ; RCM; UL; VDE

3

9124243200

Weidmueller & Kg

Thermal Magnetic Circuit Breaker

DIN Rail Mount

250 V

80 V

200 mA

Snap On

-30 °C (-22 °F)

200 A

Rated breaking capacity at 65 VDC: 200 A

Push To Reset

3.15 in (80 mm)

0.984 in (25 mm)

Corrosion Resistant; Moisture Resistant

3.15 x 0.984 x 2.087 in (80 x 25 x 53 mm)

Trip

2.087 in (53 mm)

CSA; UL; VDE

2

55 °C (131 °F)

915031

Phoenix Contact

Thermal Magnetic Circuit Breaker

915031

A9F79106

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

A9N18392

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

500 V

100 A

Snap On

-25 °C (-13 °F)

6 kA

Rated breaking capacity at 500 VDC: 10000 A

Toggle Handle

Bulk

4.252 in (108 mm)

3.189 in (81 mm)

IP20

Trip

2.874 in (73 mm)

EN; IEC

4

70 °C (158 °F)

A9R44425

Schneider Electric Sa

Equipment Leakage Circuit Breaker

DIN Rail Mount

415 V

25 A

Snap On

-5 °C (23 °F)

1.5 kA

Toggle

3.583 in (91 mm)

2.835 in (72 mm)

IP20; IP40

3.583 x 2.835 x 2.894 in (91 x 72 x 73.5 mm)

Trip

2.894 in (73.5 mm)

EN/IEC

4

60 °C (140 °F)

Instantaneous

A9R44463

Schneider Electric Sa

Equipment Leakage Circuit Breaker

DIN Rail Mount

415 V

63 A

Snap On

-5 °C (23 °F)

1.5 kA

Toggle

3.583 in (91 mm)

2.835 in (72 mm)

IP20; IP40

3.583 x 2.835 x 2.894 in (91 x 72 x 73.5 mm)

Trip

2.894 in (73.5 mm)

EN/IEC

4

60 °C (140 °F)

Instantaneous

A9R61225

Schneider Electric Sa

Equipment Leakage Circuit Breaker

DIN Rail Mount

240 V

25 A

Snap On

-25 °C (-13 °F)

1.5 kA

Toggle Handle

Bulk

3.583 in (91 mm)

1.417 in (36 mm)

IP20; IP40

Trip

2.894 in (73.5 mm)

EN; IEC

2

60 °C (140 °F)

A9R61240

Schneider Electric Sa

Equipment Leakage Circuit Breaker

DIN Rail Mount

240 V

40 A

Snap On

-25 °C (-13 °F)

1.5 kA

Toggle Handle

Bulk

3.583 in (91 mm)

1.417 in (36 mm)

IP20; IP40

Trip

2.894 in (73.5 mm)

EN; IEC

2

60 °C (140 °F)

A9R61425

Schneider Electric Sa

Equipment Leakage Circuit Breaker

AA1-B0-21-620-1B1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

20 A

Quick Connect

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

AA1-B0-21-620-1D2-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

20 A

Quick Connect

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

AA1-B0-34-450-5D1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

80 V

5 A

Screw

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

AA1-B0-34-610-531-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

80 V

10 A

Screw

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

AA1-B0-34-615-331-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

80 V

15 A

Screw

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

AA1-B0-34-615-3B1-I

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

80 V

15 A

Screw

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

AA1-B0-34-615-3D1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

80 V

15 A

Screw

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

AA1-B0-34-615-3G2-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

80 V

15 A

Screw

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

AA2-B0-44-630-5B1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

30 A

Screw

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

1.515 in (38.48 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

2

85 °C (185 °F)

AC1-B0-32-410-313-D

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

80 V

1 A

Screw

-40 °C (-40 °F)

1 kA

Standards: MIL-PRF-55629, MIL-STD-202

Rocker

2.156 in (54.76 mm)

0.745 in (18.92 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL; VDE

1

85 °C (185 °F)

AC1-B1-14-410-243-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

80 V

1 A

Screw

-40 °C (-40 °F)

7.5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Rocker

2.156 in (54.76 mm)

0.745 in (18.92 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.