Circuit Breaker

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

W69-X2Q12-30

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

30 A

Quick Connect

-40 °C (-40 °F)

2.5 kA

2.2 s

Toggle

2.25 in (57.15 mm)

2 in (50.8 mm)

Fungus Resistant; Moisture Resistant

2.25 x 2 x 1.64 in (57.15 x 50.8 x 41.66 mm)

Series Trip

1.64 in (41.66 mm)

CSA; UL

3

85 °C (185 °F)

Standard

W69-X2Q1220

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

20 A

Quick Connect

2.2 s

Toggle

Series Trip

3

W93-X112-40V

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

250 V

40 A

Stud

-40 °C (-40 °F)

2 kA

2.2 s

Toggle

2.5 in (63.5 mm)

0.75 in (19.05 mm)

Series Trip

1.845 in (46.86 mm)

3

85 °C (185 °F)

XT1NU3060AFF000XXX

Abb

Thermal Magnetic Circuit Breaker

DIN Rail Mount

347 V

60 A

Snap On

18 kA

5.118 in (130 mm)

3 in (76.2 mm)

5.118 x 3 x 2.756 in (130 x 76.2 x 70 mm)

Trip

2.756 in (70 mm)

CSA; UL

3

0700030

Phoenix Contact

Thermal Circuit Breaker

07000

0712194

Phoenix Contact

Thermal Circuit Breaker

Socket Mount

250 V

65 V

1 A

Snap On

-20 °C (-4 °F)

6 A

1.752 in (44.5 mm)

0.323 in (8.2 mm)

IP40

1.752 x 0.323 x 0.961 in (44.5 x 8.2 x 24.4 mm)

0.961 in (24.4 mm)

CCC; CSA; CUL; EAC; UL; VDE

1

60 °C (140 °F)

0903030

Phoenix Contact

Magnetic Circuit Breaker

DIN Rail Mount

10 A

Screw

0 °C (32 °F)

Bulk

3.15 in (80 mm)

0.492 in (12.5 mm)

IP20

3.268 in (83 mm)

CE, UL

50 °C (122 °F)

0903032

Phoenix Contact

Magnetic Circuit Breaker

DIN Rail Mount

1 A

Screw

0 °C (32 °F)

Bulk

3.15 in (80 mm)

0.492 in (12.5 mm)

IP20

3.268 in (83 mm)

CE, UL

50 °C (122 °F)

0903038

Phoenix Contact

Magnetic Circuit Breaker

DIN Rail Mount

10 A

Screw

0 °C (32 °F)

Bulk

3.15 in (80 mm)

0.492 in (12.5 mm)

IP20

3.268 in (83 mm)

CE, UL

50 °C (122 °F)

0916613

Phoenix Contact

Thermal Magnetic Circuit Breaker

0916613

1-1393253-4

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

10 A

Quick Connect

-40 °C (-40 °F)

5 kA

30 ms

Toggle

2 in (50.8 mm)

1.5 in (38.1 mm)

Series Trip

1.64 in (41.66 mm)

2

85 °C (185 °F)

102083

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

5 A

Snap On

-25 °C (-13 °F)

15 kA

Rated breaking capacity at 400 VAC

IP20; IP40

Trip

CE; CSA; EN; IEC; UL

1

75 °C (167 °F)

1278810000

Weidmueller & Kg

Thermal Circuit Breaker

1393255-9

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

30 A

Stud

2.2 s

Toggle

Series Trip

3

1423695-7

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

50 V

3 A

Quick Connect

1 kA

10 s

Push To Reset

1.375 in (34.93 mm)

0.66 in (16.76 mm)

Series Trip

1.375 in (34.93 mm)

1

1658-G21-01-P13-15A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

28 V

15 A

Quick Connect

-20 °C (-4 °F)

1 kA

Push To Reset

Bulk

1.26 in (32 mm)

0.535 in (13.6 mm)

Corrosion/Moisture Resistant; IP00; IP40

Trip Free

1.063 in (27 mm)

CSA; CUL; UL

1

60 °C (140 °F)

16924

Schneider Electric Sa

Equipment Leakage Circuit Breaker

2-5700-IG1-P10-DD-20A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

250 V

50 V

20 A

Quick Connect

-20 °C (-4 °F)

2 kA

Rated breaking capacity at 50 VDC: 2500 A

Push To Reset

1.142 in (29 mm)

0.571 in (14.5 mm)

Corrosion/Moisture Resistant; IP00; IP40

Trip Free

1.831 in (46.5 mm)

CQC; CSA; UL; VDE

1

60 °C (140 °F)

243211

Eaton Corporation

Thermal Circuit Breaker

DIN Rail Mount

400 V

48 V

160 mA

Snap On

-25 °C (-13 °F)

4.5 kA

Handle

Bulk

3.15 in (80 mm)

1.378 in (35 mm)

IP20

Trip

2.579 in (65.5 mm)

EN; IEC

1

75 °C (167 °F)

2907654

Phoenix Contact

Thermal Magnetic Circuit Breaker

2907654

2CSF202101R1630

Abb

Equipment Leakage Circuit Breaker

2CSF204592R3250

Abb

Equipment Leakage Circuit Breaker

2CSR155117R1104

Abb

Equipment Leakage Circuit Breaker

2CU25L

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

25 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.291 in (109 mm)

1.378 in (35 mm)

IP20

Trip

2.362 in (60 mm)

CE, CUL, UL

2

60 °C (140 °F)

2CU25R

Altech

Thermal Circuit Breaker

DIN Rail Mount

480 V

25 A

Snap On

-25 °C (-13 °F)

5 kA

Toggle Handle

Bulk

3.366 in (85.5 mm)

1.378 in (35 mm)

IP20

Trip

2.362 in (60 mm)

CE, CUL, UL

2

60 °C (140 °F)

2DU25L

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

25 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.291 in (109 mm)

1.378 in (35 mm)

IP20

Trip

2.362 in (60 mm)

CE, CUL, UL

2

60 °C (140 °F)

2DU4L

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

4 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.291 in (109 mm)

1.378 in (35 mm)

IP20

Trip

2.362 in (60 mm)

CE, CUL, UL

2

60 °C (140 °F)

2DU4R

Altech

Thermal Circuit Breaker

DIN Rail Mount

480 V

4 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

3.366 in (85.5 mm)

1.378 in (35 mm)

IP20

Trip

2.362 in (60 mm)

CE, CUL, UL

2

60 °C (140 °F)

3120-F324-P7T1-W01D-0.5A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

250 V

50 V

500 mA

Quick Connect

-30 °C (-22 °F)

5 A

Rocker

2.205 in (56 mm)

0.827 in (21 mm)

Corrosion Resistant

2.205 x 0.827 x 1.299 in (56 x 21 x 33 mm)

Manual On/Off

1.299 in (33 mm)

CCC; CSA; UL; VDE

2

60 °C (140 °F)

3120-F324-P7T1-W01D-1.5A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

250 V

50 V

1.5 A

Quick Connect

-30 °C (-22 °F)

15 A

Rocker

2.205 in (56 mm)

0.827 in (21 mm)

Corrosion Resistant

2.205 x 0.827 x 1.299 in (56 x 21 x 33 mm)

Manual On/Off

1.299 in (33 mm)

CCC; CSA; UL; VDE

2

60 °C (140 °F)

3120-F324-P7T1-W01D-6A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

250 V

50 V

6 A

Quick Connect

-30 °C (-22 °F)

6 A

Rocker

2.205 in (56 mm)

0.827 in (21 mm)

Corrosion Resistant

2.205 x 0.827 x 1.299 in (56 x 21 x 33 mm)

Manual On/Off

1.299 in (33 mm)

CCC; CSA; UL; VDE

2

60 °C (140 °F)

3131-AF1PT-000000-000-2A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

28 V

2 A

Quick Connect

-20 °C (-4 °F)

20 A

Rocker

2.008 in (51 mm)

0.945 in (24 mm)

Corrosion Resistant; IP00; IP66

Manual On/Off

1.142 in (29 mm)

UL; VDE

1

60 °C (140 °F)

3600-P10-SI-2.5A

E-t-a Elektrotechnische Apparate

Thermal Magnetic Circuit Breaker

Panel Mount

250 V

65 V

2.5 A

Quick Connect

-30 °C (-22 °F)

1 kA

Push To Reset

1.969 in (50 mm)

0.453 in (11.5 mm)

Corrosion/Moisture Resistant; IP00; IP40

Trip Free

2.008 in (51 mm)

CSA; UL

1

60 °C (140 °F)

3C15UR

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

15 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle

Bulk

3.516 in (89.3 mm)

2.067 in (52.5 mm)

IP20

Trip

2.693 in (68.4 mm)

CE; CUL; UL

3

55 °C (131 °F)

3CU05R

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

500 mA

Snap On

-20 °C (-4 °F)

10 kA

Toggle Handle

Bulk

3.366 in (85.5 mm)

2.067 in (52.5 mm)

IP20

Trip

2.362 in (60 mm)

CE, CUL, UL

3

60 °C (140 °F)

3CU15R

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

15 A

Snap On

-20 °C (-4 °F)

5 kA

Toggle Handle

Bulk

3.366 in (85.5 mm)

2.067 in (52.5 mm)

IP20

Trip

2.362 in (60 mm)

CE, CUL, UL

3

60 °C (140 °F)

3CU20R

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

20 A

Snap On

-20 °C (-4 °F)

5 kA

Toggle Handle

Bulk

3.366 in (85.5 mm)

2.067 in (52.5 mm)

IP20

Trip

2.362 in (60 mm)

CE, CUL, UL

3

60 °C (140 °F)

3CU25L

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

240 V

25 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.291 in (109 mm)

2.067 in (52.5 mm)

IP20

Trip

2.362 in (60 mm)

CE, CUL, UL

3

60 °C (140 °F)

3RV1011-1CA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

2.5 A

Snap On

-20 °C (-4 °F)

100 kA

Interrupting current max at 450 VDC: 10000 A

Rocker

3.543 in (90 mm)

1.772 in (45 mm)

IP00; IP20

3.543 x 1.772 x 2.953 in (90 x 45 x 75 mm)

Trip

2.953 in (75 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; UL; VDE

3

60 °C (140 °F)

Instantaneous

3RV1021-1DA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail And Panel Mount

690 V

3.2 A

Screw And Snap On

8 kA

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.78 in (97 x 45 x 96 mm)

Trip

3.78 in (96 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; UL; VDE

3

3RV2011-0CA15

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

250 mA

Screw And Snap On

-20 °C (-4 °F)

100 kA

Rotary Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.819 in (97 x 45 x 97 mm)

Trip

3.819 in (97 mm)

3

60 °C (140 °F)

3RV2011-0HA15

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

800 mA

Snap On

-20 °C (-4 °F)

100 kA

Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

Instantaneous

3RV2011-0JA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

1 A

Snap On

-20 °C (-4 °F)

100 kA

Interrupting current max at 450 VDC: 10000 A

Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

3RV2011-0JA15

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

1 A

Screw And Snap On

-20 °C (-4 °F)

100 kA

Rotary Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.819 in (97 x 45 x 97 mm)

Trip

3.819 in (97 mm)

3

60 °C (140 °F)

3RV2011-1EA20

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

4 A

Snap On

-20 °C (-4 °F)

4 kA

Handle

4.173 in (106 mm)

1.772 in (45 mm)

IP20

4.173 x 1.772 x 3.815 in (106 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; UL; VDE

3

60 °C (140 °F)

Instantaneous

3RV2011-1FA15

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

5 A

Screw And Snap On

-20 °C (-4 °F)

4 kA

Rotary Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.819 in (97 x 45 x 97 mm)

Trip

3.819 in (97 mm)

3

60 °C (140 °F)

3RV2021-4BA15

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

20 A

Snap On

-20 °C (-4 °F)

2 kA

Interrupting current max at 450 VDC: 10000 A

Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

Instantaneous

3RV2311-1HC10

Siemens

Magnetic Circuit Breaker

DIN Rail Mount

690 V

8 A

Screw And Snap On

-20 °C (-4 °F)

4 kA

Rotary Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.819 in (97 x 45 x 97 mm)

Trip

3.819 in (97 mm)

3

60 °C (140 °F)

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.