Circuit Breaker

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

18653

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

18654

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

18656

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

18658

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

18660

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

18662

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

18663

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

229-2-1-61-8-8-1-A

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

480 V

1 A

Stud

5 kA

Toggle Handle

5.125 in (130.18 mm)

2.072 in (52.63 mm)

Moisture Resistant

Trip Free

3.55 in (90.17 mm)

CSA; CUL; UL

2

229-2-1-61-8-9-50-A

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

480 V

50 A

Stud

5 kA

Toggle Handle

5.125 in (130.18 mm)

2.072 in (52.63 mm)

Moisture Resistant

Trip Free

3.55 in (90.17 mm)

CSA; CUL; UL

2

26799

Schneider Electric Sa

Equipment Leakage Circuit Breaker

2CSR252140R1105

Abb

Equipment Leakage Circuit Breaker

2DU3L

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

3 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.291 in (109 mm)

1.378 in (35 mm)

IP20

Trip

2.362 in (60 mm)

CE, CUL, UL

2

60 °C (140 °F)

3120-F323-P7T1-W01D-5A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

250 V

50 V

5 A

Quick Connect

-30 °C (-22 °F)

5 A

Rocker

2.126 in (54 mm)

0.827 in (21 mm)

Corrosion Resistant

2.126 x 0.827 x 1.299 in (54 x 21 x 33 mm)

Manual On/Off

1.299 in (33 mm)

CCC; CSA; UL; VDE

2

60 °C (140 °F)

3120-F323-P7T1-W19FG4-10A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

250 V

50 V

10 A

Tab/Blade

-30 °C (-22 °F)

5 kA

Rocker

Bulk

2.126 in (54 mm)

0.984 in (25 mm)

Corrosion/Moisture Resistant; IP00; IP40

Trip Free

1.299 in (33 mm)

CSA; UL

2

60 °C (140 °F)

3120-F521-P7T1-W01D-1.5A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

250 V

50 V

1.5 A

Quick Connect

-30 °C (-22 °F)

15 A

Rocker

1.89 in (48 mm)

0.827 in (21 mm)

Corrosion Resistant

1.89 x 0.827 x 1.299 in (48 x 21 x 33 mm)

Manual On/Off

1.299 in (33 mm)

CCC; CSA; UL; VDE

2

60 °C (140 °F)

3D1UR

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

1 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle

Bulk

3.516 in (89.3 mm)

2.067 in (52.5 mm)

IP20

Trip

2.693 in (68.4 mm)

CE; CUL; UL

3

55 °C (131 °F)

3RV1341-4JC10

Siemens

Magnetic Circuit Breaker

DIN Rail Mount

690 V

63 A

Screw And Snap On

-20 °C (-4 °F)

6 kA

Rotary Handle

6.496 in (165 mm)

2.756 in (70 mm)

IP20

6.496 x 2.756 x 6.85 in (165 x 70 x 174 mm)

Trip

6.85 in (174 mm)

3

60 °C (140 °F)

3RV2011-1DA15

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

3.2 A

Snap On

-20 °C (-4 °F)

10 kA

Interrupting current max at 450 VDC: 10000 A

Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

3RV2011-1FA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

5 A

Snap On

-20 °C (-4 °F)

4 kA

Interrupting current max at 450 VDC: 10000 A

Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

3RV2011-1JA20

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

10 A

Snap On

-20 °C (-4 °F)

4 kA

Interrupting current max at 450 VDC: 10000 A

Handle

4.173 in (106 mm)

1.772 in (45 mm)

IP20

4.173 x 1.772 x 3.815 in (106 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

Instantaneous

3RV2011-4AA15

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

16 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

Rotary Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.819 in (97 x 45 x 97 mm)

Trip

3.819 in (97 mm)

3

60 °C (140 °F)

3RV2021-1GA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

6.3 A

Snap On

-20 °C (-4 °F)

4 kA

Interrupting current max at 450 VDC: 10000 A

Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

Instantaneous

3RV2021-4EA15

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

32 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

Rotary Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.819 in (97 x 45 x 97 mm)

Trip

3.819 in (97 mm)

3

60 °C (140 °F)

3RV2121-4AA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

16 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

Rotary Handle

3.819 in (97 mm)

2.559 in (65 mm)

IP20

3.819 x 2.559 x 3.819 in (97 x 65 x 97 mm)

Relay Trip

3.819 in (97 mm)

3

60 °C (140 °F)

3VA5110-6EC41-0AA0

Siemens

Thermal Circuit Breaker

Panel Mount

690 V

600 V

100 A

Screw

-25 °C (-13 °F)

65 kA

Toggle

5.5 in (139.7 mm)

4 in (101.6 mm)

IP40

5.5 x 4 x 3 in (139.7 x 101.6 x 76.2 mm)

Trip

3 in (76.2 mm)

4

70 °C (158 °F)

3VA5110-6GC41-0AA0

Siemens

Thermal Circuit Breaker

Panel Mount

690 V

600 V

100 A

Screw

-25 °C (-13 °F)

65 kA

Toggle

5.5 in (139.7 mm)

4 in (101.6 mm)

IP40

5.5 x 4 x 3 in (139.7 x 101.6 x 76.2 mm)

Trip

3 in (76.2 mm)

4

70 °C (158 °F)

3VA5120-6ED21-0AA0

Siemens

Thermal Circuit Breaker

Panel Mount

600 V

250 V

20 A

Screw

-25 °C (-13 °F)

65 kA

Toggle

5.5 in (139.7 mm)

2 in (50.8 mm)

IP40

5.5 x 2 x 3 in (139.7 x 50.8 x 76.2 mm)

Trip

3 in (76.2 mm)

2

70 °C (158 °F)

3VA5210-6EC41-0AA0

Siemens

Thermal Circuit Breaker

Panel Mount

690 V

1 KV

100 A

Screw

-25 °C (-13 °F)

65 kA

Toggle

7.3 in (185.42 mm)

5.5 in (139.7 mm)

IP40

7.3 x 5.5 x 3.3 in (185.42 x 139.7 x 83.82 mm)

Trip

3.3 in (83.82 mm)

4

70 °C (158 °F)

3VA5210-6GC41-0AA0

Siemens

Thermal Circuit Breaker

Panel Mount

690 V

1 KV

100 A

Screw

-25 °C (-13 °F)

65 kA

Toggle

7.3 in (185.42 mm)

5.5 in (139.7 mm)

IP40

7.3 x 5.5 x 3.3 in (185.42 x 139.7 x 83.82 mm)

Trip

3.3 in (83.82 mm)

4

70 °C (158 °F)

4230-T120-K0DE-5A

E-t-a Elektrotechnische Apparate

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

125 V

5 A

Snap On

-35 °C (-31 °F)

5 kA

Toggle Handle

3.228 in (82 mm)

1.39 in (35.3 mm)

Corrosion Resistant; IP20

Trip Free

2.37 in (60.2 mm)

UL; TUV

2

70 °C (158 °F)

4404.0018

Schurter Ag

Thermal Circuit Breaker

Panel Mount

240 V

48 V

3 A

Quick Connect

-5 °C (23 °F)

2 kA

Reset Type

Bulk

0.606 in (15.4 mm)

0.535 in (13.6 mm)

IP40

Trip Free

1.339 in (34 mm)

CCC; CSA; GB; IEC; UL; VDE

1

60 °C (140 °F)

4420.0605

Schurter Ag

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

65 V

4 A

Snap On

-10 °C (14 °F)

5 kA

Manual On/Off

Bulk

3.543 in (90 mm)

1.378 in (35 mm)

IP40

Manual On/Off

2.425 in (61.6 mm)

CSA, CUL, IEC, UL, VDE

2

55 °C (131 °F)

4435.0029

Schurter Ag

Thermal Circuit Breaker

Panel Mount

277 V

32 V

2 A

Quick Connect

-30 °C (-22 °F)

2 kA

Rocker

Bulk

1.417 in (36 mm)

0.689 in (17.5 mm)

Trip

1.319 in (33.5 mm)

CCC; CUL; UL; VDE

1

60 °C (140 °F)

4435.0041

Schurter Ag

Thermal Circuit Breaker

4435.005

Schurter Ag

Thermal Circuit Breaker

Panel Mount

415 V

10 A

Quick Connect

-30 °C (-22 °F)

2 kA

Rocker

Bulk

1.594 in (40.5 mm)

1.417 in (36 mm)

IP40

Manual On/Off

1.736 in (44.1 mm)

CCC; CUL; UL; VDE

3

60 °C (140 °F)

482-G111-K1M1-A1S0-30A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

72 V

30 A

Screw

-55 °C (-67 °F)

5 kA

Push-Pull

1.22 in (31 mm)

0.709 in (18 mm)

Corrosion/Moisture Resistant; IP00; IP40

Trip Free

1.969 in (50 mm)

CSA; CUL; UL

1

75 °C (167 °F)

483-G411-K1M1-A1S0ZN--5A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

28 V

5 A

Screw

-55 °C (-67 °F)

2 kA

Rated breaking capacity at 28 VDC: 6000 A

Push-Pull

0.768 in (19.5 mm)

0.559 in (14.2 mm)

IP40; IP00

Tease-Free And Trip-Free

1.22 in (31 mm)

1

125 °C (257 °F)

5SU1354-7KK16

Siemens

Thermal Circuit Breaker

DIN Rail Mount

230 V

16 A

Snap On

-25 °C (-13 °F)

5SU1354-7KK16

Environmental Characteristics: IP20

3.543 in (90 mm)

1.394 in (35.4 mm)

Environment/Moisture Resistant

3.543 x 1.394 x 2.756 in (90 x 35.4 x 70 mm)

Trip

2.756 in (70 mm)

CCC; CE; EAC; IMQ; OVE; VDE

2

55 °C (131 °F)

5SU1354-7KK20

Siemens

Equipment Leakage Circuit Breaker

DIN Rail Mount

230 V

20 A

Screw And Snap On

10 kA

Handle

3.543 in (90 mm)

1.417 in (36 mm)

IP20

3.543 x 1.417 x 3.031 in (90 x 36 x 77 mm)

Trip

3.031 in (77 mm)

2

70 °C (158 °F)

5SU1356-6KK16

Siemens

Equipment Leakage Circuit Breaker

DIN Rail Mount

230 V

16 A

Snap On

-25 °C (-13 °F)

6 kA

Bulk

3.543 in (90 mm)

1.417 in (36 mm)

IP20

Trip

3.031 in (77 mm)

CCC; CE; EAC; IMQ; RCM; VDE

2

55 °C (131 °F)

5SU1356-7KK16

Siemens

Equipment Leakage Circuit Breaker

DIN Rail Mount

230 V

16 A

Screw And Snap On

6 kA

Handle

3.543 in (90 mm)

1.417 in (36 mm)

IP20

3.543 x 1.417 x 3.031 in (90 x 36 x 77 mm)

Trip

3.031 in (77 mm)

2

70 °C (158 °F)

5SV3314-6KK12

Siemens

Equipment Leakage Circuit Breaker

DIN Rail Mount

230 V

40 A

Screw And Snap On

10 kA

Handle

3.543 in (90 mm)

1.417 in (36 mm)

IP20

3.543 x 1.417 x 2.756 in (90 x 36 x 70 mm)

Trip

2.756 in (70 mm)

2

70 °C (158 °F)

5SY4204-7

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

400 V

4 A

Snap On

10 kA

3.535 in (89.8 mm)

1.386 in (35.2 mm)

IP20

3.535 x 1.386 x 2.992 in (89.8 x 35.2 x 76 mm)

Trip

2.992 in (76 mm)

CCC; CE; IMQ; KC; RCM; UL; VDE

2

5SY6332-7

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

180 V

32 A

Snap On

-25 °C (-13 °F)

5 kA

Toggle Handle

Bulk

3.543 in (90 mm)

2.126 in (54 mm)

IP20

Trip

2.992 in (76 mm)

CSA; EN; UL

3

55 °C (131 °F)

6-1393250-7

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

32 V

20 A

Quick Connect

1 kA

2.2 s

Push To Reset

0.76 in (19.31 mm)

0.76 in (19.31 mm)

Series Trip

1.535 in (38.99 mm)

1

7274-2-21/2

Sensata Technologies

Thermal Circuit Breaker

7274-2

AA1-B0-34-450-3B1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

80 V

5 A

Screw

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

BA1-B2-46-625-52A-K3

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

25 A

Screw

-40 °C (-40 °F)

3 kA

Handle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.73 in (43.94 mm)

UL; TUV

1

85 °C (185 °F)

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.