Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Actuator Type | Packing Method | Body Length/Diameter | Body Width | Environmental Characteristics | JESD-609 Code | Dimensions | Circuit Function | Body Height | Reference Standard | No. of Poles | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Schneider Electric Sa |
Thermal Magnetic Circuit Breaker |
DIN Rail And Panel Mount |
690 V |
18 A |
Screw And Snap On |
-20 °C (-4 °F) |
3 kA |
Push Button |
Bulk |
3.504 in (89 mm) |
1.772 in (45 mm) |
IK04; IP20 |
3.079 x 1.772 x 3.504 in (78.2 x 45 x 89 mm) |
Trip |
3.091 in (78.5 mm) |
ATEX; BV; CCC; CSA; DNV-GL; EAC; EN; IEC; LROS; RINA; UL |
3 |
60 °C (140 °F) |
||||||||
|
Schneider Electric Sa |
Thermal Magnetic Circuit Breaker |
DIN Rail And Panel Mount |
690 V |
25 A |
Screw And Snap On |
-20 °C (-4 °F) |
6 kA |
Reference standard: UL |
Rotary Handle |
Bulk |
5.197 in (132 mm) |
2.165 in (55 mm) |
IK09; IP20 |
Trip |
5.354 in (136 mm) |
ABS; ATEX; BV; CSA; CCC; DNV-GL; EAC; EN; IEC; LR0S; UKCA |
3 |
60 °C (140 °F) |
||||||||
|
Schneider Electric Sa |
Thermal Magnetic Circuit Breaker |
DIN Rail And Panel Mount |
690 V |
40 A |
Screw And Snap On |
-20 °C (-4 °F) |
6 kA |
Reference standard: UL |
Rotary Handle |
Bulk |
5.197 in (132 mm) |
2.165 in (55 mm) |
IK09; IP20 |
Trip |
5.354 in (136 mm) |
ABS; ATEX; BV; CSA; CCC; DNV-GL; EAC; EN; IEC; LR0S; UKCA |
3 |
60 °C (140 °F) |
||||||||
|
Schneider Electric Sa |
Thermal Magnetic Circuit Breaker |
DIN Rail And Panel Mount |
690 V |
40 A |
Screw And Snap On |
-20 °C (-4 °F) |
6 kA |
Rotary Handle |
Bulk |
5.197 in (132 mm) |
2.165 in (55 mm) |
IK09 |
Trip |
5.354 in (136 mm) |
CSA; EN; IEC; UL |
3 |
60 °C (140 °F) |
|||||||||
|
Sensata Technologies |
Magnetic Circuit Breaker |
Panel Mount |
250 V |
4 A |
Screw |
-40 °C (-40 °F) |
5 kA |
Toggle |
2.49 in (63.24 mm) |
0.75 in (19.05 mm) |
Corrosion/Moisture Resistant |
Trip Free |
1.859 in (47.22 mm) |
CSA; UL; VDE |
1 |
85 °C (185 °F) |
||||||||||
|
Sensata Technologies |
Magnetic Circuit Breaker |
Panel Mount |
480 V |
40 A |
Screw |
-40 °C (-40 °F) |
5 kA |
Toggle Handle |
2.49 in (63.24 mm) |
1.515 in (38.48 mm) |
Corrosion/Moisture Resistant |
Trip Free |
1.859 in (47.22 mm) |
CSA; UL; VDE |
2 |
85 °C (185 °F) |
||||||||||
Sensata Technologies |
Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
5 A |
Snap On |
-40 °C (-40 °F) |
2 kA |
Toggle Handle |
3.622 in (92 mm) |
1.515 in (38.48 mm) |
Corrosion/Moisture Resistant; IP00; IP40 |
Series Trip |
1.929 in (49 mm) |
CSA; UL; VDE |
2 |
85 °C (185 °F) |
|||||||||||
Sensata Technologies |
Magnetic Circuit Breaker |
Panel Mount |
250 V |
2.5 A |
Screw |
-40 °C (-40 °F) |
1 kA |
Toggle |
2 in (50.8 mm) |
1.515 in (38.48 mm) |
Manual On/Off |
2.256 in (57.3 mm) |
CSA, UL |
2 |
85 °C (185 °F) |
||||||||||||
|
Sensata Technologies |
Magnetic Circuit Breaker |
Panel Mount |
125 V |
40 A |
Stud |
5 kA |
Toggle Handle |
2.49 in (63.24 mm) |
1.515 in (38.48 mm) |
Corrosion/Moisture Resistant |
Trip Free |
1.859 in (47.22 mm) |
CCC; VDE |
2 |
||||||||||||
|
Schneider Electric Sa |
Thermal Circuit Breaker |
|||||||||||||||||||||||||
|
Schneider Electric Sa |
Thermal Magnetic Circuit Breaker |
|||||||||||||||||||||||||
|
Schneider Electric Sa |
Thermal Magnetic Circuit Breaker |
|||||||||||||||||||||||||
|
Schneider Electric Sa |
Thermal Magnetic Circuit Breaker |
|||||||||||||||||||||||||
|
Schneider Electric Sa |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
415 V |
60 V |
10 A |
Snap On |
-30 °C (-22 °F) |
3 kA |
Toggle |
Bulk |
4.055 in (103 mm) |
0.709 in (18 mm) |
IP20; IP40 |
Trip |
2.835 in (72 mm) |
CCC; CSA; EN; GB; IEC; UL |
1 |
70 °C (158 °F) |
||||||||
|
Schneider Electric Sa |
Thermal Magnetic Circuit Breaker |
|||||||||||||||||||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
65 V |
30 A |
Screw |
-40 °C (-40 °F) |
3 kA |
Sealed Toggle |
1.375 in (34.93 mm) |
0.65 in (16.51 mm) |
Moisture Resistant; IP68; |
Series Trip |
2.158 in (54.81 mm) |
CUL; UL |
1 |
85 °C (185 °F) |
|||||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
240 V |
20 A |
Screw |
-40 °C (-40 °F) |
2 kA |
Sealed Toggle |
1.375 in (34.93 mm) |
1.3 in (33.02 mm) |
Moisture Resistant; IP68; |
Series Trip |
2.158 in (54.81 mm) |
2 |
85 °C (185 °F) |
||||||||||||
Sensata Technologies |
Thermal Circuit Breaker |
MS25361 |
|||||||||||||||||||||||||
Eaton Corporation |
Thermal Circuit Breaker |
Panel Mount-Threaded |
120 V |
28 V |
20 A |
Screw |
500 A |
Standard: MIL-C-5809, rated breaking capacity at 28 VDC: 2000 A |
0.78 in (19.81 mm) |
0.593 in (15.06 mm) |
0.78 x 0.593 x 1.251 in (19.81 x 15.06 x 31.78 mm) |
1.251 in (31.78 mm) |
MS |
1 |
|||||||||||||
Eaton Corporation |
Thermal Circuit Breaker |
Panel Mount |
120 V |
28 V |
3 A |
Screw |
-55 °C (-67 °F) |
3.5 kA |
Standard: MIL-C-5809, rated breaking capacity at 28 VDC: 6000 A |
Push Button |
0.781 in (19.84 mm) |
0.593 in (15.06 mm) |
Corrosion Resistant; Moisture Resistant |
0.781 x 0.593 x 1.03 in (19.84 x 15.06 x 26.16 mm) |
Trip |
1.03 in (26.16 mm) |
1 |
121 °C (249.8 °F) |
|||||||||
|
Idec |
Magnetic Circuit Breaker |
DIN Rail And Panel Mount |
250 V |
65 V |
20 A |
Snap On |
-10 °C (14 °F) |
2.5 kA |
Toggle |
3.102 in (78.8 mm) |
0.689 in (17.5 mm) |
Manual On/Off |
2.598 in (66 mm) |
CCC; CE; CSA; PSE; TUV; UL |
1 |
60 °C (140 °F) |
||||||||||
|
Idec |
Magnetic Circuit Breaker |
DIN Rail Mount |
250 V |
65 V |
20 A |
Snap On |
-10 °C (14 °F) |
2.5 kA |
Toggle |
2.811 in (71.4 mm) |
0.689 in (17.5 mm) |
IP20 |
Series Trip |
2.598 in (66 mm) |
CCC; CE; CSA; PSE; TUV; UL |
1 |
60 °C (140 °F) |
|||||||||
Idec |
Magnetic Circuit Breaker |
DIN Rail Mount |
250 V |
1 A |
Snap On |
-10 °C (14 °F) |
2.5 kA |
Toggle Handle |
2.811 in (71.4 mm) |
2.067 in (52.5 mm) |
IP20 |
Series Trip |
2.598 in (66 mm) |
CCC; CE; CSA; PSE; TUV; UL |
3 |
60 °C (140 °F) |
|||||||||||
Carling Technologies |
Equipment Leakage Circuit Breaker |
Panel Mount |
240 V |
50 A |
Stud |
-35 °C (-31 °F) |
3 kA |
Handle |
3.8 in (96.52 mm) |
2.265 in (57.53 mm) |
Series Trip |
2.975 in (75.57 mm) |
CSA; UL |
2 |
66 °C (150.8 °F) |
||||||||||||
Eaton Corporation |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
690 V |
25 A |
Snap On |
-25 °C (-13 °F) |
50 kA |
Rated breaking capacity max at: 400 VAC |
Button |
3.638 in (92.4 mm) |
1.772 in (45 mm) |
IP00; IP20 |
Trip |
2.65 in (67.3 mm) |
CE; CSA; IEC/EN; UL |
3 |
55 °C (131 °F) |
||||||||||
Eaton Corporation |
Thermal Circuit Breaker |
DIN Rail Mount |
690 V |
2.5 A |
Snap On |
-25 °C (-13 °F) |
150 kA |
Rated breaking capacity at 400 VAC |
Turn Button |
3.638 in (92.4 mm) |
1.772 in (45 mm) |
IP00; IP20 |
3.638 x 1.772 x 2.65 in (92.4 x 45 x 67.3 mm) |
Trip |
2.65 in (67.3 mm) |
CE; CSA; EN; IEC; UL |
3 |
55 °C (131 °F) |
|||||||||
|
Schneider Electric Sa |
Thermal Circuit Breaker |
|||||||||||||||||||||||||
|
Schneider Electric Sa |
Thermal Circuit Breaker |
|||||||||||||||||||||||||
|
Schneider Electric Sa |
Thermal Circuit Breaker |
Panel Mount |
240 V |
48 V |
25 A |
10 kA |
Rated breaking capacity at 48 VDC: 5000 A |
4.05 in (102.87 mm) |
1.5 in (38.1 mm) |
4.05 x 1.5 x 2.95 in (102.87 x 38.1 x 74.93 mm) |
2.95 in (74.93 mm) |
CSA; IEC; UL |
2 |
|||||||||||||
|
Schneider Electric Sa |
Thermal Circuit Breaker |
|||||||||||||||||||||||||
Abb |
Thermal Circuit Breaker |
DIN Rail Mount |
230 V |
20 A |
Snap On |
-25 °C (-13 °F) |
10 kA |
Manual On/Off |
2.795 in (71 mm) |
0.689 in (17.5 mm) |
IP20 |
2.795 x 0.689 x 3.622 in (71 x 17.5 x 92 mm) |
3.622 in (92 mm) |
CCC; CSA; IEC; UL; VDE |
1 |
55 °C (131 °F) |
|||||||||||
|
Abb |
Thermal Magnetic Circuit Breaker |
|||||||||||||||||||||||||
|
Abb |
Thermal Magnetic Circuit Breaker |
|||||||||||||||||||||||||
Abb |
Thermal Magnetic Circuit Breaker |
||||||||||||||||||||||||||
Abb |
Thermal Magnetic Circuit Breaker |
||||||||||||||||||||||||||
Abb |
Thermal Magnetic Circuit Breaker |
||||||||||||||||||||||||||
TE Connectivity |
Thermal Circuit Breaker |
||||||||||||||||||||||||||
|
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
250 V |
50 V |
5 A |
Quick Connect |
2 kA |
6 s |
Push To Reset |
1.375 in (34.93 mm) |
0.66 in (16.76 mm) |
1.375 x 0.66 x 1.375 in (34.93 x 16.76 x 34.93 mm) |
Series Trip |
1.375 in (34.93 mm) |
CSA; UL |
1 |
||||||||||
|
TE Connectivity |
Magnetic Circuit Breaker |
Panel Mount |
65 V |
25 A |
Quick Connect |
2.2 s |
Toggle |
Series Trip |
1 |
|||||||||||||||||
|
Phoenix Contact |
Magnetic Circuit Breaker |
DIN Rail Mount |
24 V |
500 mA |
Screw |
0 °C (32 °F) |
Bulk |
3.15 in (80 mm) |
0.492 in (12.5 mm) |
IP20 |
3.268 in (83 mm) |
CE, UL |
50 °C (122 °F) |
|||||||||||||
|
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
250 V |
50 V |
2 A |
Quick Connect |
-20 °C (-4 °F) |
1 kA |
ENVIRONMENTAL CHARACTERISTICS: IP40; IP00 |
Push Button |
0.748 in (19 mm) |
0.52 in (13.2 mm) |
Corrosion Resistant; Moisture Resistant |
0.748 x 0.52 x 1.87 in (19 x 13.2 x 47.5 mm) |
Tease-Free And Trip-Free |
1.87 in (47.5 mm) |
CBE; CSA; IEC; UL; VDE |
1 |
60 °C (140 °F) |
Medium |
||||||
|
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
250 V |
72 V |
6 A |
Quick Connect |
-20 °C (-4 °F) |
2 kA |
Push Button |
1.921 in (48.8 mm) |
0.323 in (8.2 mm) |
IP00; IP40 |
0.961 x 0.323 x 1.921 in (24.4 x 8.2 x 48.8 mm) |
Trip Free |
0.961 in (24.4 mm) |
CQC; CSA; EN; IEC; UL; VDE |
1 |
60 °C (140 °F) |
||||||||
|
Rockwell Automation |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
600 V |
600 V |
25 A |
Snap On |
-25 °C (-13 °F) |
10 kA |
Manual On/Off |
3.622 in (92 mm) |
1.772 in (45 mm) |
Moisture Resistant; IP2X |
Shunt Trip |
2.618 in (66.5 mm) |
CCC; CE; CSA; CUL; EN; IEC; UL |
3 |
60 °C (140 °F) |
Instantaneous |
||||||||
|
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Through Hole Mount |
240 V |
28 V |
4 A |
Printed Circuit Board |
-20 °C (-4 °F) |
Silver |
2 kA |
Rated breaking capacity at 50 VDC: 200 A, Environmental Characteristics: IP40; IP00 |
Reset Button |
0.984 in (25 mm) |
0.504 in (12.8 mm) |
Corrosion Resistant; Moisture Resistant |
e4 |
0.984 x 0.504 x 0.591 in (25 x 12.8 x 15 mm) |
0.591 in (15 mm) |
CSA; UL; VDE |
1 |
70 °C (158 °F) |
||||||
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Inline/Holder |
32 V |
10 A |
Tab/Blade |
-40 °C (-40 °F) |
150 A |
Push To Reset |
0.787 in (20 mm) |
0.236 in (6 mm) |
Corrosion Resistant; IP00; IP30; IP54 |
Trip Free |
0.945 in (24 mm) |
UL |
1 |
85 °C (185 °F) |
|||||||||||
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Inline/Holder |
32 V |
6 A |
Tab/Blade |
-40 °C (-40 °F) |
150 A |
Push To Reset |
0.787 in (20 mm) |
0.236 in (6 mm) |
Corrosion Resistant; IP00; IP30; IP54 |
Trip Free |
0.945 in (24 mm) |
UL |
1 |
85 °C (185 °F) |
|||||||||||
Eaton Corporation |
Thermal Circuit Breaker |
Panel Mount |
30 V |
150 A |
Screw |
-32 °C (-25.6 °F) |
Lever |
2.89 in (73.41 mm) |
1.9 in (48.26 mm) |
Trip |
1.44 in (36.58 mm) |
SAE; UL |
1 |
82 °C (179.6 °F) |
|||||||||||||
Sensata Technologies |
Magnetic Circuit Breaker |
Panel Mount |
480 V |
30 A |
Quick Connect |
10 kA |
Toggle Handle |
5.8 in (147.32 mm) |
3.108 in (78.94 mm) |
Moisture Resistant |
Trip Free |
2.61 in (66.29 mm) |
CSA; CUL; UL; VDE |
3 |
A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.
Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.
In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.