Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Nominal Joule Integral | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Pre Arcing Rating (A2/s) | Packing Method | Body Length/Diameter | Body Width | Fuse Class | JESD-609 Code | Rated Voltage | Resistance | Minimum Pre Arcing Time | Fuse Size | Built-in Features | Dimensions | Body Height | Reference Standard | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
150 A |
Tab/Blade |
2.382 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 500 VDC: 50000 A |
Bulk |
1.218 in (30.94 mm) |
10 ms |
2.125 in (53.98 mm) |
CE; CUL; UL |
125 °C (257 °F) |
Very Fast |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
250 V |
15 A |
End Cap |
1.237 kJ |
-55 °C (-67 °F) |
Nickel |
500 A |
10 ms |
Pre Arcing Time: Open within 10 ms at 1000% Rated Current |
1237 |
Bulk |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
IEC; PSE; SEMKO; UL |
125 °C (257 °F) |
Time Lag |
||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
3.15 A |
End Cap |
6.7 J |
-55 °C (-67 °F) |
Nickel |
1.5 kA |
20 ms |
6.7 |
Bulk |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; IEC; KC; PSE; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Fast |
||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
315 mA |
End Cap |
10 mJ |
-55 °C (-67 °F) |
Tin |
1.5 kA |
20 ms |
0.01 |
Bulk |
0.205 in (5.2 mm) |
e3 |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; IEC; SEMKO; UL; VDE |
125 °C (257 °F) |
Fast |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
4 A |
End Cap |
69.1 J |
-55 °C (-67 °F) |
Nickel |
40 A |
20 ms |
69.1 |
Bulk |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; KC; PSE; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Time Lag |
||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
2 A |
End Cap |
8.25 J |
-60 °C (-76 °F) |
Nickel |
10 kA |
2 m |
Pre Arcing Time: Open within 2 m at 200% Rated Current |
Bulk |
0.205 in (5.2 mm) |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CE; KC; PSE |
125 °C (257 °F) |
Medium |
|||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
2.5 A |
End Cap |
79.705 J |
-55 °C (-67 °F) |
Nickel |
100 A |
2 m |
79.705 |
Bulk |
0.205 in (5.2 mm) |
Supplemental |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CE; CSA; KC; PSE; UL |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
2 A |
Tab/Blade |
1.4 J |
-40 °C (-40 °F) |
Tin |
1 kA |
20 ms |
0.752 in (19.1 mm) |
0.201 in (5.1 mm) |
e3 |
0.752 x 0.201 x 0.484 in (19.1 x 5.1 x 12.3 mm) |
0.74 in (18.8 mm) |
CSA; UL |
125 °C (257 °F) |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
20 A |
Tab/Blade |
520 J |
-40 °C (-40 °F) |
Silver |
1 kA |
80 ms |
0.752 in (19.1 mm) |
0.201 in (5.1 mm) |
e4 |
0.752 x 0.201 x 0.484 in (19.1 x 5.1 x 12.3 mm) |
0.74 in (18.8 mm) |
CSA; UL |
125 °C (257 °F) |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
250 V |
2.5 A |
End Cap |
136 J |
-55 °C (-67 °F) |
Nickel |
100 A |
4 h |
136 |
Bulk |
0.25 in (6.35 mm) |
250 V |
3AB |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CE; CSA; KC; PSE; UL |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
2.5 A |
End Cap |
185 J |
-55 °C (-67 °F) |
Nickel |
100 A |
5 s |
Rated Breaking Capacity at 125 VDC: 10000 A |
136 |
Bulk |
0.25 in (6.35 mm) |
250 V |
3AB |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CE; CSA; KC; PSE; UL |
125 °C (257 °F) |
Time Delay |
||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
250 V |
25 A |
End Cap |
1.03 kJ |
-55 °C (-67 °F) |
Nickel |
400 A |
4 h |
1030 |
Bulk |
0.25 in (6.35 mm) |
250 V |
3AB |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CE; CSA; PSE; UL |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
25 A |
End Cap |
1.03 kJ |
-55 °C (-67 °F) |
Nickel |
400 A |
5 s |
Rated Breaking Capacity at 125 VDC: 600 A |
1030 |
Bulk |
0.25 in (6.35 mm) |
250 V |
3AB |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CE; CSA; PSE; UL |
125 °C (257 °F) |
Time Delay |
||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
60 A |
Tab/Blade |
21.7 kJ |
-40 °C (-40 °F) |
Tin |
2 kA |
Bulk |
0.63 in (16 mm) |
0.472 in (12 mm) |
e3 |
0.63 x 0.472 x 0.315 in (16 x 12 x 8 mm) |
0.315 in (8 mm) |
UL |
125 °C (257 °F) |
Time Delay |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
58 V |
7.5 A |
Tab/Blade |
53 J |
-40 °C (-40 °F) |
1 kA |
30 ms |
Bulk |
0.429 in (10.9 mm) |
0.15 in (3.8 mm) |
58 V |
Mini |
0.299 in (7.6 mm) |
ISO |
125 °C (257 °F) |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
58 V |
15 A |
Tab/Blade |
270 J |
-40 °C (-40 °F) |
Silver Over Nickel |
1 kA |
30 ms |
0.429 in (10.9 mm) |
0.15 in (3.8 mm) |
e4 |
58 V |
Mini |
0.429 x 0.15 x 0.346 in (10.9 x 3.8 x 8.8 mm) |
0.346 in (8.8 mm) |
ISO; UL |
125 °C (257 °F) |
|||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
58 V |
15 A |
Tab/Blade |
270 J |
-40 °C (-40 °F) |
Silver |
1 kA |
Rated Breaking Capacity at 58 VDC: 1000 A |
Bulk |
0.429 in (10.9 mm) |
0.14 in (3.55 mm) |
e4 |
0.429 x 0.14 x 0.346 in (10.9 x 3.55 x 8.8 mm) |
0.346 in (8.8 mm) |
125 °C (257 °F) |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
500 V |
500 mA |
End Cap |
100 kA |
Rated Breaking Capacity at 500 VDC: 50000 A |
0.406 in (10.31 mm) |
0.394 x 1.496 in (10 x 38 mm) |
1.5 in (38.1 mm) |
CSA; UL |
Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
500 V |
6 A |
End Cap |
100 kA |
Rated Breaking Capacity at 500 VDC: 50000 A |
0.406 in (10.31 mm) |
0.394 x 1.496 in (10 x 38 mm) |
1.5 in (38.1 mm) |
CSA; UL |
Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
500 V |
10 A |
End Cap |
100 kA |
Rated Breaking Capacity at 500 VDC: 50000 A |
0.406 in (10.31 mm) |
600 V |
0.394 x 1.496 in (10 x 38 mm) |
0.406 x 1.5 in (10.31 x 38.1 mm) |
1.5 in (38.1 mm) |
CSA; UL |
Fast |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
170 V |
70 A |
Tab/Blade |
100 kA |
Bulk |
0.563 in (14.3 mm) |
0.877 in (22.28 mm) |
CUL; IEC; TUV; UL |
||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
70 A |
Tab/Blade |
22 kJ |
-40 °C (-40 °F) |
Tin |
2 kA |
100 ms |
22000 |
0.63 in (16 mm) |
0.472 in (12 mm) |
e3 |
32 V |
0.63 x 0.472 x 0.315 in (16 x 12 x 8 mm) |
0.307 in (7.8 mm) |
CUL; ISO; UL |
125 °C (257 °F) |
|||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
48 V |
100 A |
Tab/Blade |
-40 °C (-40 °F) |
600 A |
200 ms |
Bulk |
1.26 in (32 mm) |
0.866 in (22 mm) |
48 V |
1.26 x 0.866 x 0.413 in (32 x 22 x 10.5 mm) |
0.413 in (10.5 mm) |
CUL; UL |
125 °C (257 °F) |
||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
250 A |
Tab/Blade |
4.2 kJ |
200 kA |
Box |
1.772 in (45 mm) |
1.772 in (45 mm) |
Indicator |
1.772 x 1.772 x 1.969 in (45 x 45 x 50 mm) |
1.969 in (50 mm) |
CE; IEC; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
400 A |
Tab/Blade |
15 kJ |
200 kA |
Box |
1.772 in (45 mm) |
1.772 in (45 mm) |
Indicator |
1.772 x 1.772 x 1.969 in (45 x 45 x 50 mm) |
1.969 in (50 mm) |
CE; IEC; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
1 KV |
250 A |
Tab/Blade |
10 kJ |
150 kA |
2.126 in (54 mm) |
1.181 in (30 mm) |
Indicator |
2.126 x 1.181 x 2.008 in (54 x 30 x 51 mm) |
2.008 in (51 mm) |
CE; DIN 43653; IEC; UL |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
700 A |
Tab/Blade |
60.5 kJ |
200 kA |
Box |
1.969 in (50 mm) |
2.402 in (61 mm) |
Indicator |
1.969 x 2.402 x 2.402 in (50 x 61 x 61 mm) |
2.402 in (61 mm) |
CE; DIN 43653; IEC; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
1.3 KV |
1.1 kA |
End Cap |
575 kJ |
100 kA |
3.189 in (81 mm) |
2.992 in (76 mm) |
Indicator |
3.189 x 2.992 x 2.992 in (81 x 76 x 76 mm) |
2.992 in (76 mm) |
CE; IEC; UL |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
690 V |
2 kA |
Tab/Blade |
600 kJ |
200 kA |
Box |
4.134 in (105 mm) |
2.087 in (53 mm) |
Indicator |
4.134 x 2.087 x 4.134 in (105 x 53 x 105 mm) |
4.134 in (105 mm) |
CE; IEC; UL |
||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
2 A |
End Cap |
11 J |
100 A |
4 h |
11 |
0.25 in (6.35 mm) |
250 V |
3AB |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CSA; PSE; QPL; UL |
Fast |
||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
32 A |
Tab/Blade |
1.8 kJ |
120 kA |
Box |
1.929 in (49 mm) |
0.827 in (21 mm) |
NH000 |
Indicator |
1.614 in (41 mm) |
CE; DIN; IEC; VDE |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
3.15 A |
End Cap |
13 J |
Nickel |
35 A |
Bag |
0.205 in (5.2 mm) |
250 V |
10 ms |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
BSI; CCC; CSA; CUL; IMQ; SEMKO; UL; VDE |
Fast |
|||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
315 mA |
End Cap |
580 mJ |
Nickel |
35 A |
Bag |
0.205 in (5.2 mm) |
250 V |
10 ms |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
BSI; CCC; CSA; CUL; IMQ; SEMKO; UL; VDE |
Fast |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
500 mA |
End Cap |
10 kA |
2 m |
Bulk |
0.406 in (10.31 mm) |
250 V |
5AG |
0.406 x 1.5 in (10.31 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; UL |
Fast |
|||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
20 A |
End Cap |
120 kA |
C10 |
0.394 in (10 mm) |
0.394 x 1.496 in (10 x 38 mm) |
1.496 in (38 mm) |
IEC |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
1 A |
End Cap |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
0.406 in (10.3 mm) |
600 V |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
6 A |
End Cap |
Nickel |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
0.406 in (10.3 mm) |
600 V |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; UL |
Time Delay |
||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
250 V |
40 A |
End Cap |
200 kA |
Rated Breaking Capacity at 500 VDC: 20000 A |
Bulk |
0.85 in (21.6 mm) |
600 V |
1.882 in (47.8 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
450 V |
30 A |
End Cap |
200 kA |
Rated Breaking Capacity at 450 VDC: 100000 A |
0.81 in (20.57 mm) |
0.81 x 2.25 in (20.57 x 57.15 mm) |
2.25 in (57.15 mm) |
CSA; UL |
Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
2 A |
End Cap |
10 kA |
5 s |
Pre Arcing Time: Open within 5 s at 200% Rated Current |
Bulk |
0.406 in (10.31 mm) |
250 V |
0.394 x 1.496 in (10 x 38 mm) |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; QPL; UL |
Time Delay |
|||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
1.5 A |
End Cap |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
0.811 in (20.6 mm) |
Indicator |
0.811 x 5 in (20.6 x 127 mm) |
5 in (127 mm) |
CSA; QPL; UL |
Time Delay |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
15 A |
End Cap |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
0.811 in (20.6 mm) |
Indicator |
0.811 x 5 in (20.6 x 127 mm) |
5 in (127 mm) |
CSA; QPL; UL |
Time Delay |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
150 mA |
End Cap |
200 kA |
0.811 in (20.6 mm) |
Indicator |
0.811 x 5 in (20.6 x 127 mm) |
5 in (127 mm) |
CSA; UL |
Time Delay |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
3 A |
End Cap |
23.21 J |
Nickel |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
0.406 in (10.3 mm) |
CC |
600 V |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CSA; UL |
Time Delay |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
3 A |
End Cap |
23.21 J |
200 kA |
12 s |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
0.406 in (10.3 mm) |
1.5 in (38.1 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
6 A |
End Cap |
129.5 J |
Nickel |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
0.406 in (10.3 mm) |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CSA; UL |
Time Delay |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
6 A |
End Cap |
129.5 J |
200 kA |
12 s |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
0.406 in (10.3 mm) |
1.5 in (38.1 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
1 A |
End Cap |
8 mJ |
-55 °C (-67 °F) |
100 kA |
4 m |
0.406 in (10.31 mm) |
600 V |
0.394 x 1.496 in (10 x 38 mm) |
1.5 x 1.5 in (38.1 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; IEC; UL |
125 °C (257 °F) |
Fast |
A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.
Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.
In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.