Inline/Holder Fuses 2,400+

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

L50QS150.V

Littelfuse

Electric Fuse

Inline/Holder

500 V

500 V

150 A

Tab/Blade

2.382 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 500 VDC: 50000 A

Bulk

1.218 in (30.94 mm)

10 ms

2.125 in (53.98 mm)

CE; CUL; UL

125 °C (257 °F)

Very Fast

0215015.MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 V

15 A

End Cap

1.237 kJ

-55 °C (-67 °F)

Nickel

500 A

10 ms

Pre Arcing Time: Open within 10 ms at 1000% Rated Current

1237

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

IEC; PSE; SEMKO; UL

125 °C (257 °F)

Time Lag

02163.15MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

3.15 A

End Cap

6.7 J

-55 °C (-67 °F)

Nickel

1.5 kA

20 ms

6.7

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; KC; PSE; SEMKO; SEV; UL; VDE

125 °C (257 °F)

Fast

0216.315MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

315 mA

End Cap

10 mJ

-55 °C (-67 °F)

Tin

1.5 kA

20 ms

0.01

Bulk

0.205 in (5.2 mm)

e3

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; SEMKO; UL; VDE

125 °C (257 °F)

Fast

0218004.MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

4 A

End Cap

69.1 J

-55 °C (-67 °F)

Nickel

40 A

20 ms

69.1

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; KC; PSE; SEMKO; SEV; UL; VDE

125 °C (257 °F)

Time Lag

0232002.MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

2 A

End Cap

8.25 J

-60 °C (-76 °F)

Nickel

10 kA

2 m

Pre Arcing Time: Open within 2 m at 200% Rated Current

Bulk

0.205 in (5.2 mm)

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; KC; PSE

125 °C (257 °F)

Medium

023902.5MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

2.5 A

End Cap

79.705 J

-55 °C (-67 °F)

Nickel

100 A

2 m

79.705

Bulk

0.205 in (5.2 mm)

Supplemental

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; CSA; KC; PSE; UL

125 °C (257 °F)

Time Lag

0287002.PXS

Littelfuse

Electric Fuse

Inline/Holder

32 V

2 A

Tab/Blade

1.4 J

-40 °C (-40 °F)

Tin

1 kA

20 ms

0.752 in (19.1 mm)

0.201 in (5.1 mm)

e3

0.752 x 0.201 x 0.484 in (19.1 x 5.1 x 12.3 mm)

0.74 in (18.8 mm)

CSA; UL

125 °C (257 °F)

0287020.H

Littelfuse

Electric Fuse

Inline/Holder

32 V

20 A

Tab/Blade

520 J

-40 °C (-40 °F)

Silver

1 kA

80 ms

0.752 in (19.1 mm)

0.201 in (5.1 mm)

e4

0.752 x 0.201 x 0.484 in (19.1 x 5.1 x 12.3 mm)

0.74 in (18.8 mm)

CSA; UL

125 °C (257 °F)

032602.5HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 V

2.5 A

End Cap

136 J

-55 °C (-67 °F)

Nickel

100 A

4 h

136

Bulk

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; KC; PSE; UL

125 °C (257 °F)

Time Lag

032602.5MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

2.5 A

End Cap

185 J

-55 °C (-67 °F)

Nickel

100 A

5 s

Rated Breaking Capacity at 125 VDC: 10000 A

136

Bulk

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; KC; PSE; UL

125 °C (257 °F)

Time Delay

0326025.HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 V

25 A

End Cap

1.03 kJ

-55 °C (-67 °F)

Nickel

400 A

4 h

1030

Bulk

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; PSE; UL

125 °C (257 °F)

Time Lag

0326025.MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

25 A

End Cap

1.03 kJ

-55 °C (-67 °F)

Nickel

400 A

5 s

Rated Breaking Capacity at 125 VDC: 600 A

1030

Bulk

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; PSE; UL

125 °C (257 °F)

Time Delay

0498060.M

Littelfuse

Electric Fuse

Inline/Holder

32 V

60 A

Tab/Blade

21.7 kJ

-40 °C (-40 °F)

Tin

2 kA

Bulk

0.63 in (16 mm)

0.472 in (12 mm)

e3

0.63 x 0.472 x 0.315 in (16 x 12 x 8 mm)

0.315 in (8 mm)

UL

125 °C (257 °F)

Time Delay

089107.5NXS

Littelfuse

Electric Fuse

Inline/Holder

58 V

7.5 A

Tab/Blade

53 J

-40 °C (-40 °F)

1 kA

30 ms

Bulk

0.429 in (10.9 mm)

0.15 in (3.8 mm)

58 V

Mini

0.299 in (7.6 mm)

ISO

125 °C (257 °F)

0997015.WXN

Littelfuse

Electric Fuse

Inline/Holder

58 V

15 A

Tab/Blade

270 J

-40 °C (-40 °F)

Silver Over Nickel

1 kA

30 ms

0.429 in (10.9 mm)

0.15 in (3.8 mm)

e4

58 V

Mini

0.429 x 0.15 x 0.346 in (10.9 x 3.8 x 8.8 mm)

0.346 in (8.8 mm)

ISO; UL

125 °C (257 °F)

0997015WXN

Littelfuse

Electric Fuse

Inline/Holder

58 V

15 A

Tab/Blade

270 J

-40 °C (-40 °F)

Silver

1 kA

Rated Breaking Capacity at 58 VDC: 1000 A

Bulk

0.429 in (10.9 mm)

0.14 in (3.55 mm)

e4

0.429 x 0.14 x 0.346 in (10.9 x 3.55 x 8.8 mm)

0.346 in (8.8 mm)

125 °C (257 °F)

0KLK.500T

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

500 mA

End Cap

100 kA

Rated Breaking Capacity at 500 VDC: 50000 A

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Fast

0KLK006.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

6 A

End Cap

100 kA

Rated Breaking Capacity at 500 VDC: 50000 A

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Fast

0KLK010.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

10 A

End Cap

100 kA

Rated Breaking Capacity at 500 VDC: 50000 A

0.406 in (10.31 mm)

600 V

0.394 x 1.496 in (10 x 38 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Fast

0TLS070.TXLR

Littelfuse

Electric Fuse

Inline/Holder

170 V

70 A

Tab/Blade

100 kA

Bulk

0.563 in (14.3 mm)

0.877 in (22.28 mm)

CUL; IEC; TUV; UL

153.5631.5701

Littelfuse

Electric Fuse

Inline/Holder

32 V

70 A

Tab/Blade

22 kJ

-40 °C (-40 °F)

Tin

2 kA

100 ms

22000

0.63 in (16 mm)

0.472 in (12 mm)

e3

32 V

0.63 x 0.472 x 0.315 in (16 x 12 x 8 mm)

0.307 in (7.8 mm)

CUL; ISO; UL

125 °C (257 °F)

157.5701.6101

Littelfuse

Electric Fuse

Inline/Holder

48 V

100 A

Tab/Blade

-40 °C (-40 °F)

600 A

200 ms

Bulk

1.26 in (32 mm)

0.866 in (22 mm)

48 V

1.26 x 0.866 x 0.413 in (32 x 22 x 10.5 mm)

0.413 in (10.5 mm)

CUL; UL

125 °C (257 °F)

170M3416

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

250 A

Tab/Blade

4.2 kJ

200 kA

Box

1.772 in (45 mm)

1.772 in (45 mm)

Indicator

1.772 x 1.772 x 1.969 in (45 x 45 x 50 mm)

1.969 in (50 mm)

CE; IEC; UL

170M3469

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

400 A

Tab/Blade

15 kJ

200 kA

Box

1.772 in (45 mm)

1.772 in (45 mm)

Indicator

1.772 x 1.772 x 1.969 in (45 x 45 x 50 mm)

1.969 in (50 mm)

CE; IEC; UL

170M4814

Eaton Corporation

Electric Fuse

Inline/Holder

1 KV

250 A

Tab/Blade

10 kJ

150 kA

2.126 in (54 mm)

1.181 in (30 mm)

Indicator

2.126 x 1.181 x 2.008 in (54 x 30 x 51 mm)

2.008 in (51 mm)

CE; DIN 43653; IEC; UL

170M5013

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

700 A

Tab/Blade

60.5 kJ

200 kA

Box

1.969 in (50 mm)

2.402 in (61 mm)

Indicator

1.969 x 2.402 x 2.402 in (50 x 61 x 61 mm)

2.402 in (61 mm)

CE; DIN 43653; IEC; UL

170M6499

Eaton Corporation

Electric Fuse

Inline/Holder

1.3 KV

1.1 kA

End Cap

575 kJ

100 kA

3.189 in (81 mm)

2.992 in (76 mm)

Indicator

3.189 x 2.992 x 2.992 in (81 x 76 x 76 mm)

2.992 in (76 mm)

CE; IEC; UL

170M7082

Eaton Corporation

Electric Fuse

Inline/Holder

690 V

2 kA

Tab/Blade

600 kJ

200 kA

Box

4.134 in (105 mm)

2.087 in (53 mm)

Indicator

4.134 x 2.087 x 4.134 in (105 x 53 x 105 mm)

4.134 in (105 mm)

CE; IEC; UL

314002

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

2 A

End Cap

11 J

100 A

4 h

11

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA; PSE; QPL; UL

Fast

32NHG000B

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

32 A

Tab/Blade

1.8 kJ

120 kA

Box

1.929 in (49 mm)

0.827 in (21 mm)

NH000

Indicator

1.614 in (41 mm)

CE; DIN; IEC; VDE

BK1/S500-3.15-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

3.15 A

End Cap

13 J

Nickel

35 A

Bag

0.205 in (5.2 mm)

250 V

10 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

BSI; CCC; CSA; CUL; IMQ; SEMKO; UL; VDE

Fast

BK1/S500-315-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

315 mA

End Cap

580 mJ

Nickel

35 A

Bag

0.205 in (5.2 mm)

250 V

10 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

BSI; CCC; CSA; CUL; IMQ; SEMKO; UL; VDE

Fast

BLF.500

Littelfuse

Electric Fuse

Inline/Holder

250 V

500 mA

End Cap

10 kA

2 m

Bulk

0.406 in (10.31 mm)

250 V

5AG

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Fast

C10G20

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

20 A

End Cap

120 kA

C10

0.394 in (10 mm)

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

IEC

CCMR001.HXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

1 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

CCMR006.TXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

6 A

End Cap

Nickel

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

CCMR040.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

250 V

40 A

End Cap

200 kA

Rated Breaking Capacity at 500 VDC: 20000 A

Bulk

0.85 in (21.6 mm)

600 V

1.882 in (47.8 mm)

CE; CSA; UL

Time Delay

DFJ-30

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

450 V

30 A

End Cap

200 kA

Rated Breaking Capacity at 450 VDC: 100000 A

0.81 in (20.57 mm)

0.81 x 2.25 in (20.57 x 57.15 mm)

2.25 in (57.15 mm)

CSA; UL

Fast

FLM002

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

2 A

End Cap

10 kA

5 s

Pre Arcing Time: Open within 5 s at 200% Rated Current

Bulk

0.406 in (10.31 mm)

250 V

0.394 x 1.496 in (10 x 38 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; QPL; UL

Time Delay

FLSR01.5ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

1.5 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

Indicator

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; QPL; UL

Time Delay

FLSR015ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

15 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

Indicator

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; QPL; UL

Time Delay

FLSR0.15ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

150 mA

End Cap

200 kA

0.811 in (20.6 mm)

Indicator

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

KLDR003.TXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

3 A

End Cap

23.21 J

Nickel

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

CC

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

KLDR003TXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

3 A

End Cap

23.21 J

200 kA

12 s

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

KLDR006.TXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

6 A

End Cap

129.5 J

Nickel

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

KLDR006TXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

6 A

End Cap

129.5 J

200 kA

12 s

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

KLKD001.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

1 A

End Cap

8 mJ

-55 °C (-67 °F)

100 kA

4 m

0.406 in (10.31 mm)

600 V

0.394 x 1.496 in (10 x 38 mm)

1.5 x 1.5 in (38.1 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL

125 °C (257 °F)

Fast

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.