Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Nominal Joule Integral | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Pre Arcing Rating (A2/s) | Packing Method | Body Length/Diameter | Body Width | Fuse Class | JESD-609 Code | Rated Voltage | Resistance | Minimum Pre Arcing Time | Fuse Size | Built-in Features | Dimensions | Body Height | Reference Standard | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
100 A |
Tab/Blade |
-40 °C (-40 °F) |
Tin |
300 kA |
Rated Breaking Capacity at 300 VDC: 100000 A |
Box |
2.992 in (76 mm) |
0.984 in (25 mm) |
e3 |
Indicator |
3.01 x 1 x 1.26 in (76.45 x 25.4 x 32 mm) |
1.26 in (32 mm) |
CSA; UL |
80 °C (176 °F) |
Time Delay |
||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
125 V |
30 A |
End Cap |
10 kA |
Box |
CE; UL |
Time Delay |
||||||||||||||||||||||
Mersen S A |
Electric Fuse |
Inline/Holder |
250 V |
250 V |
1.4 A |
End Cap |
200 kA |
Rated Breaking Capacity at 250 VDC: 20 A |
0.551 in (14 mm) |
2.008 in (51 mm) |
CSA; UL |
Time Delay |
|||||||||||||||||||
Mersen S A |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
1.4 A |
End Cap |
200 kA |
Rated Breaking Capacity at 600 VDC: 20000 A |
0.827 in (21 mm) |
5 in (127 mm) |
CSA; UL |
Time Delay |
|||||||||||||||||||
|
Schurter Ag |
Electric Fuse |
Inline/Holder |
250 V |
150 V |
10 A |
End Cap |
400 J |
-55 °C (-67 °F) |
Nickel |
1 kA |
Rated Breaking Capacity at 150 VDC: 1500 A |
Bulk |
0.205 in (5.2 mm) |
10 ms |
0.197 x 0.787 in (5 x 20 mm) |
0.787 in (20 mm) |
CCC; CUL; METI; UL; VDE |
125 °C (257 °F) |
Time Lag |
|||||||||||
|
Schurter Ag |
Electric Fuse |
Inline/Holder |
250 V |
150 V |
10 A |
End Cap |
400 J |
-55 °C (-67 °F) |
Nickel |
1 kA |
400 |
Bulk |
0.205 in (5.2 mm) |
10 ms |
0.205 x 0.787 in (5.2 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CUL; METI; UL; VDE |
125 °C (257 °F) |
Time Lag |
||||||||||
|
Schurter Ag |
Electric Fuse |
Inline/Holder |
250 V |
32 mA |
End Cap |
82 μJ |
-55 °C (-67 °F) |
Nickel |
100 A |
Box |
0.205 in (5.2 mm) |
20 ms |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CUL; VDE; UL |
125 °C (257 °F) |
Very Fast |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
1.25 A |
End Cap |
27.15 J |
-55 °C (-67 °F) |
Nickel |
35 A |
20 ms |
27.15 |
Bulk |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.228 x 0.886 in (5.8 x 22.5 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; PSE; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Time Lag |
||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
200 mA |
End Cap |
4.39 mJ |
-55 °C (-67 °F) |
Tin |
1.5 kA |
0.0043 |
Bulk |
0.205 in (5.2 mm) |
e3 |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; IEC; SEMKO; UL; VDE |
125 °C (257 °F) |
Fast |
||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
5 A |
End Cap |
111 J |
-55 °C (-67 °F) |
Nickel |
50 A |
20 ms |
111 |
Bulk |
0.205 in (5.2 mm) |
Supplemental |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; IEC; KC; PSE; SEMKO; UL; VDE |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
15 A |
Tab/Blade |
340 J |
-40 °C (-40 °F) |
Tin |
1 kA |
100 ms |
Bulk |
0.752 in (19.1 mm) |
0.201 in (5.1 mm) |
e3 |
0.74 in (18.8 mm) |
UL |
105 °C (221 °F) |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
5 A |
End Cap |
140 J |
-55 °C (-67 °F) |
Nickel |
200 A |
Bulk |
0.25 in (6.35 mm) |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CE; CSA; KTL; PSE; UL |
125 °C (257 °F) |
Time Lag |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
3.2 A |
End Cap |
209 J |
-60 °C (-76 °F) |
Nickel |
100 A |
5 s |
209 |
Bulk |
0.25 in (6.35 mm) |
Supplemental |
250 V |
3AG |
1.25 x 0.25 in (31.75 x 6.35 mm) |
1.25 in (31.75 mm) |
CE; CSA; KC; PSE; UL |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
3.2 A |
End Cap |
214 J |
-55 °C (-67 °F) |
Nickel |
100 A |
5 s |
214 |
Bulk |
0.25 in (6.35 mm) |
250 V |
3AB |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CE; CSA; KC; PSE; UL |
125 °C (257 °F) |
Time Delay |
||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
425 V |
40 A |
Tab/Blade |
1.495 kJ |
-40 °C (-40 °F) |
10 kA |
50 ms |
0.406 in (10.3 mm) |
425 V |
1.531 in (38.9 mm) |
CSA; UL |
125 °C (257 °F) |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
275 V |
50 A |
Tab/Blade |
1.495 kJ |
-40 °C (-40 °F) |
Nickel |
10 kA |
50 ms |
0.406 in (10.31 mm) |
1.53 in (38.86 mm) |
CSA; UL |
125 °C (257 °F) |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
500 V |
1 A |
End Cap |
100 kA |
Rated Breaking Capacity at 500 VDC: 50000 A |
0.406 in (10.31 mm) |
0.394 x 1.496 in (10 x 38 mm) |
1.5 in (38.1 mm) |
CSA; UL |
Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1 KV |
30 A |
End Cap |
3.29 kJ |
Silver |
50 kA |
4 m |
Bulk |
0.406 in (10.31 mm) |
e4 |
0.394 x 1.496 in (10 x 38 mm) |
1.5 in (38.1 mm) |
CE; CSA; IEC; UL |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
5 A |
End Cap |
140 J |
200 A |
0.25 in (6.35 mm) |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CE; CSA; METI; PSE; UL |
Slow |
||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
5 A |
End Cap |
32.83 J |
Nickel |
200 A |
2 m |
Pre Arcing Time: Open within 120 s at 200% Rated Current |
0.25 in (6.35 mm) |
250 V |
3AB |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CSA; UL |
Fast |
||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
4 A |
End Cap |
86.56 J |
-55 °C (-67 °F) |
Nickel |
200 A |
Pre Arcing Time: Open within 120 s at 200% Rated Current |
0.0305 |
Box |
0.25 in (6.35 mm) |
250 V |
0.248 x 1.26 in (6.3 x 32 mm) |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CSA; UL |
125 °C (257 °F) |
Fast |
||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
80 V |
200 A |
End Cap |
2.7 kA |
3.189 in (81 mm) |
Indicator |
3.189 x 0.874 in (81 x 22.2 mm) |
0.874 in (22.2 mm) |
CSA; UL |
Time Delay |
||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
125 V |
6 A |
End Cap |
88 J |
Nickel |
10 kA |
Pre Arcing Time: OPEN within 2 MIN at 200% RATED CURRENT |
Bag |
0.205 in (5.2 mm) |
125 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CSA; KC; MITI; UL |
Time Delay |
|||||||||||||
|
Cooper Industries |
Electric Fuse |
Inline/Holder |
125 V |
6 A |
End Cap |
88 J |
Nickel |
10 kA |
GMC |
Bag |
0.205 in (5.2 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CSA; MITI; UL |
Medium Time Delay |
|||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
40 A |
End Cap |
120 kA |
C14 |
0.551 in (14 mm) |
0.551 x 2.008 in (14 x 51 mm) |
2.008 in (51 mm) |
IEC |
||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
10 A |
End Cap |
100 A |
0.205 in (5.2 mm) |
250 V |
10 ms |
0.197 x 0.787 in (5 x 20 mm) |
0.218 x 0.831 in (5.54 x 21.1 mm) |
0.787 in (20 mm) |
UL; VDE |
Fast |
||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
500 V |
400 A |
Tab/Blade |
1.055 MJ |
200 kA |
Rated Breaking Capacity at 500 VDC: 20000 A |
Bulk |
2 in (50.8 mm) |
Indicator |
2.126 x 3.374 in (54 x 85.7 mm) |
3.374 in (85.7 mm) |
CSA; UL |
Time Delay |
|||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
3.5 A |
End Cap |
Nickel |
200 kA |
Box |
0.406 in (10.3 mm) |
CC |
600 V |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; UL |
Fast |
|||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
200 A |
Tab/Blade |
10 kA |
Rated Breaking Capacity at 125 VDC: 10000 A |
Box |
1.56 in (39.62 mm) |
H |
250 V |
1.56 x 7.13 in (39.62 x 181.1 mm) |
7.13 in (181.1 mm) |
CE; CSA; UL |
||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
500 V |
250 V |
4 A |
End Cap |
120 kA |
Rated Breaking Capacity at 250 VDC: 100000 A |
0.402 in (10.2 mm) |
1.496 in (38 mm) |
CE |
|||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1 KV |
1 KV |
1 A |
End Cap |
449 mJ |
-55 °C (-67 °F) |
10 kA |
Bulk |
0.25 in (6.35 mm) |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CE; CUL; UL |
125 °C (257 °F) |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
400 V |
2 A |
End Cap |
9.12 J |
-55 °C (-67 °F) |
Nickel |
100 A |
10 ms |
Rated Breaking Capacity at 400 VDC: 1500 A |
Bulk |
0.205 in (5.2 mm) |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
PSE |
125 °C (257 °F) |
Time Lag |
||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
60 A |
Tab/Blade |
21 kJ |
-40 °C (-40 °F) |
Silver |
2 kA |
100 ms |
Bulk |
1.15 in (29.2 mm) |
0.748 in (19 mm) |
e4 |
32 V |
Mega |
1.15 x 0.75 x 0.39 in (29.2 x 19.05 x 9.9 mm) |
0.39 in (9.9 mm) |
125 °C (257 °F) |
Time Delay |
||||||||||
|
Bourns |
Electric Fuse |
Inline/Holder |
800 V |
800 V |
50 A |
Tab/Blade |
800 J |
-55 °C (-67 °F) |
100 kA |
Rated Breaking Capacity at 800 VDC: 50000 A |
Bulk |
0.949 in (24.1 mm) |
2.717 in (69 mm) |
CUL; UL |
125 °C (257 °F) |
|||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
125 V |
4 A |
End Cap |
19 J |
Nickel |
10 kA |
Pre Arcing Time: OPEN within 2 MIN at 200% RATED CURRENT |
Box |
0.205 in (5.2 mm) |
125 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CSA; PSE; UL |
Fast |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
8 A |
End Cap |
341.5 J |
-55 °C (-67 °F) |
Nickel |
80 A |
341.5 |
Bulk |
0.205 in (5.2 mm) |
Supplemental |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CE; CSA; IEC; KC; PSE; UL; VDE |
125 °C (257 °F) |
Time Lag |
||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
400 A |
Tab/Blade |
18 kJ |
200 kA |
Box |
2.126 in (54 mm) |
1.181 in (30 mm) |
Indicator |
2.126 x 1.181 x 2.008 in (54 x 30 x 51 mm) |
2.008 in (51 mm) |
CE; CSA; DIN 43653; IEC; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
240 V |
150 V |
80 A |
Tab/Blade |
300 J |
200 kA |
Rated Breaking Capacity at 150 VDC: 200000 A |
Box |
0.697 in (17.7 mm) |
0.697 x 1.031 in (17.7 x 26.2 mm) |
1.031 in (26.2 mm) |
CE; IEC; UL |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
10 A |
End Cap |
760 J |
-55 °C (-67 °F) |
Nickel |
300 A |
Bulk |
1.25 in (31.75 mm) |
1.25 x 0.25 in (31.75 x 6.35 mm) |
0.25 in (6.35 mm) |
CE; CSA; PSE; UL |
125 °C (257 °F) |
Time Lag |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
1 KV |
200 A |
Tab/Blade |
108 kJ |
200 kA |
10 m |
Rated Breaking Capacity at 1000 VDC: 20000 A |
Bulk |
1.5 in (38.1 mm) |
Midget |
1.5 x 3 in (38.1 x 76.2 mm) |
3.012 in (76.5 mm) |
CE; IEC; UL; VDE |
||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
Tab/Blade |
-40 °C (-40 °F) |
Bulk |
125 °C (257 °F) |
|||||||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
50 A |
Tab/Blade |
11.3 kJ |
-40 °C (-40 °F) |
Silver |
Rated Breaking Capacity at 32 VDC: 1000 A |
1.15 in (29.21 mm) |
0.348 in (8.85 mm) |
e4 |
1.15 x 0.348 x 0.85 in (29.21 x 8.85 x 21.59 mm) |
0.85 in (21.59 mm) |
125 °C (257 °F) |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
50 A |
Tab/Blade |
11.3 kJ |
-40 °C (-40 °F) |
Silver |
1 kA |
40 ms |
11300 |
Bulk |
1.15 in (29.2 mm) |
0.346 in (8.8 mm) |
e4 |
32 V |
1.15 x 0.348 x 0.85 in (29.21 x 8.85 x 21.59 mm) |
0.85 in (21.6 mm) |
UL |
125 °C (257 °F) |
Time Delay |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
58 V |
40 A |
Tab/Blade |
5.5 kJ |
-40 °C (-40 °F) |
1 kA |
40 ms |
Bulk |
0.571 in (14.5 mm) |
0.472 in (12 mm) |
58 V |
0.63 in (16 mm) |
ISO; SAE |
125 °C (257 °F) |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
58 V |
40 A |
Tab/Blade |
-40 °C (-40 °F) |
1 kA |
Bulk |
0.571 in (14.5 mm) |
0.472 in (12 mm) |
0.571 x 0.472 x 0.63 in (14.5 x 12 x 16 mm) |
0.63 in (16 mm) |
125 °C (257 °F) |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
50 mA |
End Cap |
190 μJ |
-55 °C (-67 °F) |
Nickel |
1.5 kA |
20 ms |
0.0001 |
Bulk |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; IEC; SEMKO; UL; VDE |
125 °C (257 °F) |
Fast |
||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
400 V |
8 A |
End Cap |
203.52 J |
-55 °C (-67 °F) |
Nickel |
100 A |
10 ms |
Rated Breaking Capacity at 400 VDC: 500 A |
Bulk |
0.205 in (5.2 mm) |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CUL; PSE; UL |
125 °C (257 °F) |
Time Lag |
||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
30 A |
Tab/Blade |
4.2 kJ |
-40 °C (-40 °F) |
Tin |
2 kA |
Bulk |
0.63 in (16 mm) |
0.472 in (12 mm) |
e3 |
0.63 x 0.472 x 0.315 in (16 x 12 x 8 mm) |
0.315 in (8 mm) |
125 °C (257 °F) |
Time Delay |
A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.
Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.
In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.