Inline/Holder Fuses 2,400+

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

NON-6-1/4

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 V

6.25 A

End Cap

50 kA

Rated Breaking Capacity at 125 VDC: 50000 A

Box

0.56 in (14.22 mm)

K5

250 V

0.56 x 2 in (14.22 x 50.8 mm)

2 in (50.8 mm)

CE; CSA; UL

NON-600

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 V

600 A

Tab/Blade

10 kA

Rated Breaking Capacity at 125 VDC: 10000 A

Box

2.59 in (65.78 mm)

H

250 V

2.59 x 10.375 in (65.78 x 263.52 mm)

10.375 in (263.52 mm)

CE; CSA; UL

NON-65

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 V

65 A

10 kA

NON

Rated Breaking Capacity at 125 VDC: 10000 A

Box

CE; CSA; UL

OT60

Mersen S A

Electric Fuse

Inline/Holder

250 V

250 V

60 A

End Cap

50 kA

Rated Breaking Capacity at 250 VDC: 20000 A

0.827 in (21 mm)

0.827 x 2.992 in (21 x 76 mm)

2.992 in (76 mm)

CSA; UL

PF-ET1-30

Bourns

Electric Fuse

Inline/Holder

1 KV

30 A

Tab/Blade

2.229 kJ

-55 °C (-67 °F)

20 kA

4 m

Tray

0.406 in (10.3 mm)

5AG

1.496 in (38 mm)

CUL; UL

125 °C (257 °F)

PSR030US0125Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

125 A

Tab/Blade

707 J

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

1.878 in (47.7 mm)

1.693 in (43 mm)

Indicator

3.067 in (77.9 mm)

CUL; UL

125 °C (257 °F)

Fast

PSX3XLUB1250X

Littelfuse

Electric Fuse

Inline/Holder

1.5 KV

1.25 kA

Tab/Blade

995.376 kJ

-55 °C (-67 °F)

250 kA

Bulk

5.067 in (128.7 mm)

2.894 in (73.5 mm)

Indicator

2.894 in (73.5 mm)

CUL; UL

125 °C (257 °F)

Fast

PV-10A10-T

Eaton Corporation

Electric Fuse

Inline/Holder

1 KV

10 A

Tab/Blade

7 J

-40 °C (-40 °F)

50 kA

Box

0.406 in (10.3 mm)

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

CCC; CSA; IEC; UL

90 °C (194 °F)

REN-60

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

60 A

End Cap

10 kA

Box

0.81 in (20.57 mm)

3 in (76.2 mm)

S-2

Eaton Corporation

Electric Fuse

Inline/Holder

125 V

2 A

10 kA

CE; CSA; UL

Time Delay

S500-32-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

32 mA

End Cap

47 μJ

Silver

35 A

0.205 in (5.2 mm)

e4

250 V

3600 s

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

Fast

S500-630-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

630 mA

End Cap

350 mJ

Nickel

35 A

0.205 in (5.2 mm)

250 V

10 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

BSI; CCC; CSA; CUL; IMQ; SEMKO; UL; VDE

Fast

S505-2-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

2 A

End Cap

9.6 J

Nickel

1.5 kA

9.6

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

BSI; CCC/CQC; CSA; IEC; IMQ; KC; PSE/JET; SEMKO; UL; VDE

Time Delay

S506-4-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

4 A

End Cap

91 J

Nickel

35 A

71.8

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; IEC; IMQ; SEMKO; UL; VDE

Time Delay

S506-5-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

5 A

End Cap

133 J

Nickel

35 A

142.5

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; IEC; IMQ; SEMKO; UL; VDE

Time Delay

SC-35

Eaton Corporation

Electric Fuse

Inline/Holder

480 V

300 V

35 A

End Cap

100 kA

Rated Breaking Capacity at 300 VDC: 10000 A

Box

0.406 in (10.3 mm)

G

480 V

0.406 x 2.25 in (10.3 x 57.15 mm)

2.25 in (57.15 mm)

CSA; UL

Fast And Time Delay

SPFJ200.XXL

Littelfuse

Electric Fuse

Inline/Holder

600 V

1 KV

200 A

Tab/Blade

79.642 kJ

20 kA

10 m

Rated Breaking Capacity at 1000 VDC: 20000 A

Bulk

1.5 in (38.1 mm)

Midget

3.012 in (76.5 mm)

CE; IEC; UL; VDE

SPFJ250.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

1 KV

250 A

Tab/Blade

85.9 kJ

200 kA

12 m

Rated Breaking Capacity at 1000 VDC: 20000 A

Bulk

2 in (50.8 mm)

Midget

2 x 3.374 in (50.8 x 85.7 mm)

3.374 in (85.7 mm)

CE; IEC; UL; VDE

T-6-1/4

Eaton Corporation

Electric Fuse

Inline/Holder

125 V

6.25 A

10 kA

Box

CE; CSA; UL

Time Delay

TPC-40

Eaton Corporation

Electric Fuse

Inline/Holder

80 V

40 A

Tab/Blade

100 kA

Rated Breaking Capacity at 80 VDC: 100000 A

1.846 in (46.89 mm)

0.547 in (13.89 mm)

Alarm

1.846 x 0.547 x 1.824 in (46.89 x 13.89 x 46.34 mm)

1.824 in (46.34 mm)

CE; UL

0001.1015

Schurter Ag

Electric Fuse

Inline/Holder

250 V

12.5 A

End Cap

203 J

-55 °C (-67 °F)

Nickel

1 kA

Box

0.787 in (20 mm)

30 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.205 in (5.2 mm)

CUL; METI; UL

125 °C (257 °F)

Very Fast

0001.2512

Schurter Ag

Electric Fuse

Inline/Holder

250 V

150 V

6.3 A

End Cap

171 J

-55 °C (-67 °F)

Nickel

1.5 kA

Rated Breaking Capacity at 150 VDC: 1500 A

171

Box

0.205 in (5.2 mm)

10 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CUL; KTL; METI; UL; VDE

125 °C (257 °F)

Time Lag

0001.2707.22

Schurter Ag

Electric Fuse

Inline/Holder

250 V

300 V

2 A

End Cap

9.2 J

-55 °C (-67 °F)

Gold

1.5 kA

Rated Breaking Capacity at 300 VDC: 1500 A

Tape And Reel, 13 inch

0.205 in (5.2 mm)

e4

10 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CUL; VDE; UL

125 °C (257 °F)

Time Lag

0034.3768

Schurter Ag

Electric Fuse

Inline/Holder

250 V

250 mA

End Cap

290 mJ

-40 °C (-40 °F)

Nickel

100 A

Rated Breaking Capacity at 125 VAC: 10000 A

Box

0.205 in (5.2 mm)

120 s

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CUL; UL

85 °C (185 °F)

Time Lag

0034.5630.22

Schurter Ag

Electric Fuse

Inline/Holder

250 V

20 A

End Cap

3.057 kJ

-55 °C (-67 °F)

Gold

200 A

Tape And Reel, 13 inch

0.205 in (5.2 mm)

e4

20 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

125 °C (257 °F)

Time Lag

0090.0020

Schurter Ag

Electric Fuse

Inline/Holder

1 KV

20 A

End Cap

1.313 kJ

-50 °C (-58 °F)

Nickel

20 kA

Bulk

0.406 in (10.3 mm)

240 s

0.406 x 1.496 in (10.3 x 38 mm)

0.406 x 1.496 in (10.3 x 38 mm)

1.496 in (38 mm)

CSA; UL

125 °C (257 °F)

0215012.MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 V

12 A

End Cap

515.5 J

-55 °C (-67 °F)

Nickel

1.5 kA

10 ms

Pre Arcing Time: Open within 10 ms at 1000% Rated Current

515.5

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; IEC; CSA; KC; PSE; SEMKO; UL

125 °C (257 °F)

Time Lag

0217.800MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

800 mA

End Cap

850 mJ

-55 °C (-67 °F)

Nickel

35 A

10 ms

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

BSI; CCC; CE; CSA; IEC; KC; SEMKO; UL; VDE

125 °C (257 °F)

Very Fast

02170.04HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

40 mA

End Cap

80 μJ

-55 °C (-67 °F)

35 A

3 ms

Pre Arcing Time: Open within 3 ms at 400% Rated Current

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; CUL; KC; SEMKO; UL; VDE

125 °C (257 °F)

Fast

02170.25HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 mA

End Cap

40 mJ

-55 °C (-67 °F)

35 A

10 ms

Pre Arcing Time: Open within 10 ms at 400% Rated Current

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; CUL; KC; SEMKO; UL; VDE

125 °C (257 °F)

Fast

0217004.HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

4 A

End Cap

29.165 J

-55 °C (-67 °F)

Matte Tin

40 A

10 ms

29.165

Bulk

0.205 in (5.2 mm)

e3

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; KC; PSE; SEMKO; SEV; UL; VDE

125 °C (257 °F)

Very Fast

0217010.MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

10 A

End Cap

217.635 J

-55 °C (-67 °F)

Nickel

100 A

10 ms

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; CSA; PSE; UL; VDE

125 °C (257 °F)

Very Fast

0217015.HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

15 A

End Cap

607.135 J

-55 °C (-67 °F)

Nickel

150 A

10 ms

607.13

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; IEC; PSE; VDE

125 °C (257 °F)

Very Fast

021702.5HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

2.5 A

End Cap

9.46 J

-55 °C (-67 °F)

Matte Tin

35 A

10 ms

9.46

Bulk

0.205 in (5.2 mm)

e3

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; KC; PSE; SEMKO; SEV; UL; VDE

125 °C (257 °F)

Very Fast

0218.125MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 mA

End Cap

146.5 mJ

-55 °C (-67 °F)

Nickel

35 A

20 ms

0.1465

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; KC; SEMKO; SEV; UL; VDE

125 °C (257 °F)

Time Lag

0218.160HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

160 mA

End Cap

144 mJ

-55 °C (-67 °F)

Matte Tin

35 A

0.144

Bulk

0.205 in (5.2 mm)

Supplemental

e3

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; KC; SEMKO; UL; VDE

125 °C (257 °F)

Time Lag

0218.400TXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

400 mA

End Cap

1.325 J

-55 °C (-67 °F)

Matte Tin

35 A

20 ms

1.325

Bulk

0.205 in (5.2 mm)

Supplemental

e3

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

BSI, CCC, CE, CSA, KC, SEMKO, UL, VDE

125 °C (257 °F)

Time Lag

02181.25MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

1.25 A

End Cap

12.65 J

-55 °C (-67 °F)

Nickel

35 A

20 ms

Bulk

0.205 in (5.2 mm)

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; KC; PSE; SEMKO; SEV; UL; VDE

125 °C (257 °F)

Time Lag

021812.5MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

12.5 A

End Cap

889 J

-55 °C (-67 °F)

Matte Tin

63 A

20 ms

Bulk

0.205 in (5.2 mm)

e3

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; PSE; UL

125 °C (257 °F)

Time Lag

0229003.HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

3 A

End Cap

77 J

-55 °C (-67 °F)

Tin

100 A

Rated Breaking Capacity at 125 VDC: 10000 A

Bulk

0.177 in (4.5 mm)

e3

Indicator

0.177 x 0.57 in (4.5 x 14.48 mm)

0.57 in (14.48 mm)

CE; CSA; PSE; UL

125 °C (257 °F)

Time Lag

0298125.UXT

Littelfuse

Electric Fuse

Inline/Holder

32 V

125 A

Tab/Blade

57.8 kJ

-40 °C (-40 °F)

2 kA

100 ms

Bulk

1.15 in (29.2 mm)

0.748 in (19 mm)

32 V

Mega

0.39 in (9.9 mm)

125 °C (257 °F)

Time Delay

0298125.ZXEH

Littelfuse

Electric Fuse

Inline/Holder

32 V

125 A

Tab/Blade

57.8 kJ

-40 °C (-40 °F)

2 kA

100 ms

Bulk

1.15 in (29.2 mm)

0.748 in (19 mm)

32 V

Mega

1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm)

0.39 in (9.9 mm)

125 °C (257 °F)

Time Delay

0298125.ZXEH-UL

Littelfuse

Electric Fuse

Inline/Holder

32 V

125 A

Tab/Blade

57.8 kJ

-40 °C (-40 °F)

2 kA

100 ms

1.15 in (29.2 mm)

0.748 in (19 mm)

32 V

Mega

1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm)

0.39 in (9.9 mm)

ISO; UL

125 °C (257 °F)

Time Delay

0298125ZXEH

Littelfuse

Electric Fuse

Inline/Holder

32 V

125 A

Tab/Blade

57.8 kJ

-40 °C (-40 °F)

Silver

2 kA

Bulk

1.15 in (29.21 mm)

0.75 in (19.05 mm)

e4

1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm)

0.42 in (10.67 mm)

125 °C (257 °F)

0298125ZXEH-UL

Littelfuse

Electric Fuse

Inline/Holder

32 V

125 A

Tab/Blade

57.8 kJ

-40 °C (-40 °F)

2 kA

Bulk

1.15 in (29.21 mm)

0.75 in (19.05 mm)

1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm)

0.42 in (10.67 mm)

UL

125 °C (257 °F)

Time Delay

0298400.TXN

Littelfuse

Electric Fuse

Inline/Holder

32 V

400 A

Tab/Blade

-40 °C (-40 °F)

2 kA

Bulk

1.15 in (29.21 mm)

0.75 in (19.05 mm)

1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm)

0.42 in (10.67 mm)

125 °C (257 °F)

0298400.ZXA

Littelfuse

Electric Fuse

Inline/Holder

32 V

400 A

Tab/Blade

610 kJ

-40 °C (-40 °F)

2 kA

100 ms

Bulk

1.15 in (29.2 mm)

0.748 in (19 mm)

32 V

Mega

0.421 in (10.7 mm)

125 °C (257 °F)

Time Delay

0298400.ZXH

Littelfuse

Electric Fuse

Inline/Holder

32 V

400 A

Tab/Blade

610 kJ

-40 °C (-40 °F)

2 kA

100 ms

Bulk

1.15 in (29.2 mm)

0.748 in (19 mm)

32 V

Mega

1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm)

0.421 in (10.7 mm)

125 °C (257 °F)

Time Delay

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.