Inline/Holder Fuses 2,400+

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

BK-GMD-2.5-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

2.5 A

End Cap

94 J

Nickel

100 A

Pre Arcing Time: Open within 5 s at 200% Rated Current

94

Box

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CSA; PSE/JET; UL

Time Delay

BK-GMD-630-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

630 mA

End Cap

3.1 J

Nickel

35 A

Pre Arcing Time: Open within 5 s at 200% Rated Current

3.1

Box

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CSA; UL

Time Delay

BK-MDL-1-1/2-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

1.5 A

End Cap

22.7 J

Nickel

100 A

Box

0.25 in (6.35 mm)

250 V

0.252 x 1.248 in (6.4 x 31.7 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; UL

Time Delay

BK-MDL-1/2-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

500 mA

End Cap

1.656 J

Nickel

35 A

Box

0.25 in (6.35 mm)

250 V

0.252 x 1.248 in (6.4 x 31.7 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; UL

Time Delay

BK-S505-3-15-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

3.15 A

End Cap

36.6 J

-55 °C (-67 °F)

1.5 kA

Bulk

0.205 in (5.2 mm)

250 V

10 ms

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

BSI, CCC, CSA, CUL, IMQ, KC, PSE, SEMKO, UL, VDE

125 °C (257 °F)

Time Delay

BK/GBB-6-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 V

6 A

End Cap

Nickel

200 A

Rated Breaking Capacity at 125 VDC: 10000 A

Box

0.25 in (6.35 mm)

250 V

0.236 x 1.26 in (6 x 32 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA; UL

Very Fast

BK/GDC-500MA

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

500 mA

End Cap

827 mJ

Nickel

35 A

Box

0.205 in (5.2 mm)

250 V

20 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CUL; IMQ; UL

Time Delay

BK/GMD-2.5-R

Cooper Industries

Electric Fuse

Inline/Holder

250 V

2.5 A

End Cap

94 J

Nickel

100 A

94

Box

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CSA; PSEJET; UL

Time Delay

BK/GMD-630-R

Cooper Industries

Electric Fuse

Inline/Holder

250 V

630 mA

End Cap

3.1 J

Nickel

35 A

3.1

Box

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CSA; UL

Time Delay

BK/MDA-20-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 V

20 A

End Cap

483.45 J

Nickel

1.5 kA

2 m

Rated Breaking Capacity at 125 VDC: 10000 A

Box

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA, UL

Time Delay

BK/MDA-30A

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

32 V

30 A

End Cap

1.097 kJ

1.5 kA

Response Time: 120 s MAX at 200% Rated Current, Interrupting Current-Max(DC): 10000 A

Bulk

0.25 in (6.35 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE

Time Delay

BK/MDL-1-1/2-R

Cooper Electronic Technologies

Electric Fuse

Inline/Holder

250 V

1.5 A

End Cap

22.7 J

100 A

MDL

Box

0.25 in (6.35 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA; UL

Time Delay

BK/MDL-12-R

Eaton Corporation

Electric Fuse

Inline/Holder

32 V

32 V

12 A

End Cap

Nickel

1 kA

Pre Arcing Time: Open within 5 s at 200% Rated Current

Bulk

0.25 in (6.35 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE

Time Delay

BK/MDL-1/2-R

Cooper Electronic Technologies

Electric Fuse

Inline/Holder

250 V

500 mA

End Cap

1.656 J

35 A

MDL

Box

0.25 in (6.35 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA; UL

Time Delay

BK/S500-630-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

630 mA

End Cap

350 mJ

Nickel

35 A

Box

0.205 in (5.2 mm)

250 V

10 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

BSI; CCC; CSA; CUL; IMQ; SEMKO; UL; VDE

Fast

BK/S501-3.15-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

315 mA

End Cap

10 mJ

Nickel

1.5 kA

8.1

Box

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

BSI; CCC; CSA; IMQ; SEMKO; UL; VDE

Fast

BK/S501-315-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

315 mA

End Cap

10 mJ

Silver

1.5 kA

0.01

Box

0.205 in (5.2 mm)

e4

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

BSI; CCC; CSA; IMQ; SEMKO; UL; VDE

Fast

BK/S505-3.15R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

3.15 A

End Cap

27 J

Nickel

1.5 kA

36.6

Box

0.205 in (5.2 mm)

250 V

10 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CSA; IEC; IMQ; SEMKO; UL; VDE

Time Delay

BK/S505-3.15-R

Cooper Electronic Technologies

Electric Fuse

Inline/Holder

250 V

3.15 A

End Cap

27 J

1.5 kA

S505

Box

0.205 in (5.2 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

BSI; IMQ; MITI; SEMKO; UL; VDE

Time Delay

BK1-GMD-3-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

3 A

End Cap

145 J

Nickel

100 A

Pre Arcing Time: Open within 5 s at 200% Rated Current

145

Bag

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CSA; PSE/JET; UL

Time Delay

BK1/GMA-250-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

250 mA

End Cap

18 mJ

Silver

35 A

Pre Arcing Time: OPEN within 2 MIN at 200% RATED CURRENT

0.018

Bag

0.205 in (5.2 mm)

e4

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CSA; UL

Fast

BK1/GMD-3-R

Cooper Industries

Electric Fuse

Inline/Holder

250 V

3 A

End Cap

145 J

Nickel

100 A

145

Bag

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CSA; PSEJET; UL

Time Delay

C10M10

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

10 A

End Cap

120 kA

0.394 in (10 mm)

500 V

5AG

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

IEC

CCMR03.5TXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

3.5 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

CP4/0C1-HS

Mersen S A

Electric Fuse

Inline/Holder

600 V

Tab/Blade

200 kA

7.087 in (180 mm)

UL

DEO200

Eaton Corporation

Electric Fuse

Inline/Holder

415 V

200 A

Tab/Blade

120 kJ

Box

1.22 in (31 mm)

1.22 x 1.85 in (31 x 47 mm)

1.85 in (47 mm)

BS 88; IEC

ECSR100

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

100 A

Tab/Blade

200 kA

10 s

Pre Arcing Time: Open within 10 s at 500% Rated Current

Bulk

0.044 in (1.11 mm)

0.31 in (7.88 mm)

CE; CUL; UL

Time Delay

EV1K080

Littelfuse

Electric Fuse

Inline/Holder

1 KV

80 A

Tab/Blade

1.58 kJ

-40 °C (-40 °F)

30 kA

Bulk

1 in (25.4 mm)

2.875 in (73.03 mm)

125 °C (257 °F)

F60C500V1/8A

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

125 mA

End Cap

Nickel

0.406 in (10.3 mm)

500 V

Midget

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CSA; MIL-F-15160/60; UL

Fast

F60C500V6A

Littelfuse

Electric Fuse

Inline/Holder

500 V

500 V

6 A

End Cap

Nickel

200 kA

Rated Breaking Capacity at 500 VDC: 150000 A

0.406 in (10.31 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

MIL-PRF-15160/60

FLNR010.T

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

10 A

End Cap

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

Bulk

0.563 in (14.3 mm)

RK5

250 V

0.563 x 2 in (14.3 x 50.8 mm)

2 in (50.8 mm)

CSA; UL

Time Delay

FNM-3

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

3 A

End Cap

100 A

Box

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

FNM-3/10

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

300 mA

End Cap

35 A

Box

0.406 in (10.3 mm)

250 V

Midget

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

FNM-30

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

30 A

End Cap

10 kA

Box

0.406 in (10.3 mm)

250 V

Midget

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

FNQ-1-1/2

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

1.5 A

End Cap

10 kA

Bulk

0.406 in (10.3 mm)

CC

500 V

Midget

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE, CSA, UL

Time Delay

FNQ-14

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

14 A

End Cap

10 kA

Bulk

0.41 in (10.41 mm)

CC

500 V

Midget

0.41 x 1.5 in (10.41 x 38.1 mm)

1.5 in (38.1 mm)

CE, CSA, UL

Time Delay

FNQ-1/4

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

250 mA

End Cap

Nickel

10 kA

FNQ

Box

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

FNQ-2-1/2

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

2.5 A

End Cap

Nickel

10 kA

Bulk

0.406 in (10.3 mm)

CC

500 V

Midget

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE, CSA, UL

Time Delay

FNQ-2/10

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

200 mA

End Cap

Nickel

10 kA

Bulk

0.406 in (10.3 mm)

CC

500 V

Midget

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE, CSA, UL

Time Delay

FNQ-20

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

20 A

End Cap

10 kA

Box

0.406 in (10.3 mm)

500 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

FNQ-8

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

8 A

End Cap

Nickel

10 kA

Bulk

0.41 in (10.41 mm)

CC

500 V

Midget

0.41 x 1.5 in (10.41 x 38.1 mm)

1.5 in (38.1 mm)

CE, CSA, UL

Time Delay

FR14GG50V2P

Mersen S A

Electric Fuse

Inline/Holder

500 V

250 V

2 A

End Cap

120 kA

Rated Breaking Capacity at 250 VDC: 100000 A

0.563 in (14.3 mm)

500 V

0.563 x 2.008 in (14.3 x 51 mm)

2.008 in (51 mm)

CE; IEC60269-1; IEC60269-2

FRN-R-2

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 V

2.2 A

End Cap

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

Box

0.56 in (14.22 mm)

RK5

250 V

0.563 x 2 in (14.3 x 50.8 mm)

2 in (50.8 mm)

CE; CSA; UL

Time Delay

FRN-R-500

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

250 V

500 A

Tab/Blade

200 kA

10 s

Rated Breaking Capacity at 250 VDC: 20000 A

Box

2.88 in (73.152 mm)

RK5

250 V

2.88 x 10.38 in (73.15 x 263.65 mm)

10.38 in (263.652 mm)

CE; CSA; UL

Time Delay

FWA-1000A

Eaton Corporation

Electric Fuse

Inline/Holder

150 V

1 kA

Tab/Blade

170 kJ

200 kA

Box

1.5 in (38.1 mm)

1.5 x 1.25 in (38.1 x 31.75 mm)

1.25 in (31.75 mm)

CE; UL

FWH-100B

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

100 A

Tab/Blade

475 J

200 kA

Rated Breaking Capacity at 500 VDC: 50000 A

Box

0.947 in (24.05 mm)

0.947 x 1.736 in (24.05 x 44.09 mm)

1.736 in (44.09 mm)

CE; CSA; UL

FWH-800A

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

800 A

Tab/Blade

76.2 kJ

200 kA

Rated Breaking Capacity at 500 VDC: 50000 A

Box

2.5 in (63.5 mm)

2.5 x 2.09 in (63.5 x 53.09 mm)

2.09 in (53.09 mm)

CE; CSA; UL

FWJ-350A

Eaton Corporation

Electric Fuse

Inline/Holder

1 KV

350 A

Tab/Blade

33 kJ

100 kA

Box

2 in (50.8 mm)

2 x 3.5 in (50.8 x 88.9 mm)

3.5 in (88.9 mm)

CE; UL

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.