Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Nominal Joule Integral | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Pre Arcing Rating (A2/s) | Packing Method | Body Length/Diameter | Body Width | Fuse Class | JESD-609 Code | Rated Voltage | Resistance | Minimum Pre Arcing Time | Fuse Size | Built-in Features | Dimensions | Body Height | Reference Standard | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 mA |
End Cap |
146.5 mJ |
-55 °C (-67 °F) |
Nickel |
35 A |
20 ms |
0.1465 |
Bulk |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; KC; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Time Lag |
||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
160 mA |
End Cap |
144 mJ |
-55 °C (-67 °F) |
Matte Tin |
35 A |
0.144 |
Bulk |
0.205 in (5.2 mm) |
Supplemental |
e3 |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; IEC; KC; SEMKO; UL; VDE |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
400 mA |
End Cap |
1.325 J |
-55 °C (-67 °F) |
Matte Tin |
35 A |
20 ms |
1.325 |
Bulk |
0.205 in (5.2 mm) |
Supplemental |
e3 |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
BSI, CCC, CE, CSA, KC, SEMKO, UL, VDE |
125 °C (257 °F) |
Time Lag |
||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
1 A |
Pin Wire |
6.73 J |
-55 °C (-67 °F) |
Matte Tin |
35 A |
20 ms |
6.73 |
Bulk |
0.217 in (5.5 mm) |
Supplemental |
e3 |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.228 x 0.886 in (5.8 x 22.5 mm) |
0.846 in (21.5 mm) |
CCC; CE; CSA; KC; PSE; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Time Lag |
||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
1.25 A |
End Cap |
12.65 J |
-55 °C (-67 °F) |
Nickel |
35 A |
20 ms |
Bulk |
0.205 in (5.2 mm) |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; KC; PSE; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Time Lag |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
12.5 A |
End Cap |
889 J |
-55 °C (-67 °F) |
Matte Tin |
63 A |
20 ms |
Bulk |
0.205 in (5.2 mm) |
e3 |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CE; PSE; UL |
125 °C (257 °F) |
Time Lag |
||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
3 A |
End Cap |
77 J |
-55 °C (-67 °F) |
Tin |
100 A |
Rated Breaking Capacity at 125 VDC: 10000 A |
Bulk |
0.177 in (4.5 mm) |
e3 |
Indicator |
0.177 x 0.57 in (4.5 x 14.48 mm) |
0.57 in (14.48 mm) |
CE; CSA; PSE; UL |
125 °C (257 °F) |
Time Lag |
||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
125 V |
2.5 A |
Pin Wire |
50 J |
-55 °C (-67 °F) |
Matte Tin |
100 A |
Rated Breaking Capacity at 125 VDC: 10000 A |
Bulk |
0.185 in (4.7 mm) |
e3 |
Indicator |
0.185 x 0.57 in (4.7 x 14.48 mm) |
0.57 in (14.48 mm) |
CE; CSA; PSE; UL |
125 °C (257 °F) |
Time Lag |
||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
200 mA |
End Cap |
270 mJ |
-55 °C (-67 °F) |
Nickel |
35 A |
4 h |
0.27 |
Bulk |
0.25 in (6.35 mm) |
Supplemental |
250 V |
3AG |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CE; CSA; UL |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
30 A |
End Cap |
2.49 kJ |
-55 °C (-67 °F) |
Nickel |
100 A |
Rated Breaking Capacity at 125 VDC: 400 A |
2490 |
Bulk |
0.25 in (6.35 mm) |
250 V |
3AB |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CE; CUL; KC; PSE; UL |
125 °C (257 °F) |
Fast |
|||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
1 A |
Pin Wire |
14 J |
-55 °C (-67 °F) |
Matte Tin |
35 A |
Bulk |
0.275 in (6.985 mm) |
e3 |
0.275 x 1.275 in (6.985 x 32.385 mm) |
1.275 in (32.385 mm) |
CE; CSA; PSE; UL |
125 °C (257 °F) |
Time Lag |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
8 A |
Pin Wire |
701 J |
-60 °C (-76 °F) |
Matte Tin |
200 A |
5 s |
Bulk |
0.275 in (6.99 mm) |
e3 |
3AG |
0.275 x 1.274 in (6.99 x 32.36 mm) |
1.288 in (32.72 mm) |
CE; CSA; KC; PSE; UL |
125 °C (257 °F) |
Time Lag |
|||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
125 V |
6 A |
Pin Wire |
45 J |
-55 °C (-67 °F) |
Matte Tin |
750 A |
Rated Breaking Capacity at 125 VDC: 10000 A |
45 |
Bulk |
0.275 in (6.99 mm) |
e3 |
250 V |
3AB |
0.275 x 1.288 in (6.99 x 32.72 mm) |
1.288 in (32.72 mm) |
CE; CSA; KC; PSE; UL |
125 °C (257 °F) |
Fast |
||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
125 V |
10 A |
Pin Wire |
206 J |
-55 °C (-67 °F) |
Matte Tin |
750 A |
Rated Breaking Capacity at 125 VDC: 10000 A |
206 |
Bulk |
0.275 in (6.99 mm) |
e3 |
250 V |
3AB |
0.275 x 1.288 in (6.99 x 32.72 mm) |
1.288 in (32.72 mm) |
CE; CSA; KC; PSE; UL |
125 °C (257 °F) |
Fast |
||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
125 V |
15 A |
Pin Wire |
292 J |
-55 °C (-67 °F) |
Tin |
750 A |
Rated Breaking Capacity at 125 VDC: 10000 A |
292 |
Bulk |
0.275 in (6.99 mm) |
e3 |
250 V |
3AB |
0.275 x 1.288 in (6.99 x 32.72 mm) |
1.288 in (32.72 mm) |
CE; CSA; KC; PSE; UL |
125 °C (257 °F) |
Fast |
||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
125 V |
15 A |
Pin Wire |
292 J |
-55 °C (-67 °F) |
Tin |
750 A |
Rated Breaking Capacity at 125 VDC: 10000 A |
292 |
Bulk |
0.275 in (6.99 mm) |
e3 |
250 V |
3AB |
0.275 x 1.288 in (6.99 x 32.72 mm) |
1.288 in (32.72 mm) |
CE; CSA; PSE; UL |
125 °C (257 °F) |
Fast |
||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
250 V |
1 A |
End Cap |
16.3 J |
-55 °C (-67 °F) |
Nickel |
100 A |
5 s |
Pre Arcing Time: Open within 5 s at 200% Rated Current |
16.3 |
Bulk |
0.25 in (6.35 mm) |
250 V |
3AB |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CE, CSA, PSE, UL |
125 °C (257 °F) |
Time Lag |
||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
250 V |
20 A |
End Cap |
575 J |
-55 °C (-67 °F) |
Nickel |
400 A |
4 h |
575 |
Bulk |
0.25 in (6.35 mm) |
250 V |
3AB |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CE; CSA; KC; PSE; UL |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
250 V |
6.25 A |
End Cap |
60.4 J |
-55 °C (-67 °F) |
Nickel |
400 A |
4 h |
60.4 |
Bulk |
0.25 in (6.35 mm) |
250 V |
3AB |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CE; CSA; PSE; UL |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Bel Fuse |
Electric Fuse |
Through Hole Mount |
250 V |
630 mA |
Pin Wire |
640 mJ |
-55 °C (-67 °F) |
Matte Tin |
35 A |
Bulk |
0.217 in (5.5 mm) |
e3 |
250 V |
20 ms |
0.197 x 0.787 in (5 x 20 mm) |
0.217 x 0.827 in (5.5 x 21 mm) |
0.827 in (21 mm) |
CCC; CSA; CUL; SEMKO; UL; VDE |
125 °C (257 °F) |
Very Fast |
||||||||||
|
Bel Fuse |
Electric Fuse |
Surface Mount |
250 V |
125 V |
1.25 A |
Wraparound |
400 mJ |
-55 °C (-67 °F) |
Palladium |
300 A |
1 m |
Rated Breaking Capacity at 125 VDC: 2000 A |
Tape And Reel, 13 inch |
0.386 in (9.8 mm) |
0.12 in (3.05 mm) |
e4 |
250 V |
3912 |
0.12 in (3.05 mm) |
AEC-Q200; CUL; CE; UL |
125 °C (257 °F) |
|||||||||
|
Bel Fuse |
Electric Fuse |
Through Hole Mount |
250 V |
2.5 A |
Pin Wire |
37 J |
-55 °C (-67 °F) |
Matte Tin |
35 A |
Box; Bulk |
0.329 in (8.35 mm) |
e3 |
250 V |
20 ms |
Micro |
0.329 x 0.303 in (8.35 x 7.7 mm) |
0.303 in (7.7 mm) |
CCC; CE; CSA; IEC; PSE; SEMKO; UL; VDE |
125 °C (257 °F) |
Time Lag |
||||||||||
|
Bel Fuse |
Electric Fuse |
Through Hole Mount |
250 V |
2.5 A |
Pin Wire |
37 J |
-55 °C (-67 °F) |
Matte Tin |
35 A |
Ammo Pack; Box |
0.329 in (8.35 mm) |
e3 |
250 V |
20 ms |
Micro |
0.329 x 0.303 in (8.35 x 7.7 mm) |
0.303 in (7.7 mm) |
CCC; CE; CSA; IEC; PSE; SEMKO; UL; VDE |
125 °C (257 °F) |
Time Lag |
||||||||||
|
Siba |
Electric Fuse |
Surface Mount |
250 V |
72 V |
50 mA |
Wraparound |
13 mJ |
Silver Over Nickel |
100 A |
Tape |
0.315 in (8 mm) |
0.173 in (4.4 mm) |
e4 |
20 ms |
0.177 x 0.315 in (4.5 x 8 mm) |
0.173 x 0.173 x 0.315 in (4.4 x 4.4 x 8 mm) |
0.173 in (4.4 mm) |
IEC, UL |
Time Lag |
|||||||||||
|
Siba |
Electric Fuse |
Surface Mount |
250 V |
72 V |
500 mA |
Wraparound |
1.8 J |
Silver |
100 A |
Tape |
0.315 in (8 mm) |
0.173 in (4.4 mm) |
e4 |
250 V |
20 ms |
0.177 x 0.315 in (4.5 x 8 mm) |
0.173 in (4.4 mm) |
IEC, UL |
Time Lag |
|||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
350 mA |
Pin Wire |
490 mJ |
-55 °C (-67 °F) |
Tin/Lead |
35 A |
0.185 in (4.7 mm) |
e0 |
0.185 x 0.57 in (4.7 x 14.48 mm) |
0.57 in (14.48 mm) |
CE; CSA; PSE; UL |
125 °C (257 °F) |
Slow |
||||||||||||||
|
Schurter Ag |
Electric Fuse |
Surface Mount |
250 V |
125 V |
1.25 A |
Wraparound |
1.67 J |
-40 °C (-40 °F) |
Tin |
100 A |
Bulk |
0.433 in (11 mm) |
0.181 in (4.6 mm) |
e3 |
5 ms |
0.433 x 0.181 in (11 x 4.6 mm) |
0.433 x 0.181 x 0.154 in (11 x 4.6 x 3.9 mm) |
0.154 in (3.9 mm) |
CUL, UL |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
100 mA |
Pin Wire |
3.8 mJ |
-40 °C (-40 °F) |
Tin |
35 A |
20 ms |
Ammo Pack; Tape |
0.335 in (8.5 mm) |
e3 |
250 V |
TR5 |
0.335 x 0.315 in (8.5 x 8 mm) |
0.315 in (8 mm) |
CCC; CE; CUL; VDE; UL |
85 °C (185 °F) |
Fast |
||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
200 mA |
Pin Wire |
146 mJ |
-40 °C (-40 °F) |
Matte Tin |
50 A |
1 m |
Bulk |
0.335 in (8.5 mm) |
e3 |
250 V |
TR5 |
0.335 x 0.315 in (8.5 x 8 mm) |
0.315 in (8 mm) |
CSA, UL |
85 °C (185 °F) |
Time Lag |
||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
8 A |
Pin Wire |
220.8 J |
-40 °C (-40 °F) |
Tin |
50 A |
1 m |
Bulk |
0.335 in (8.5 mm) |
e3 |
250 V |
TR5 |
0.335 x 0.315 in (8.5 x 8 mm) |
0.315 in (8 mm) |
UL |
85 °C (185 °F) |
Time Lag |
||||||||||
|
Bel Fuse |
Electric Fuse |
Inline/Holder |
250 V |
2.5 A |
End Cap |
12 J |
-55 °C (-67 °F) |
200 A |
Pre-Arcing Time: Open within 5 s, at 200% Rated Current |
Bulk; Tape And Reel |
0.25 in (6.35 mm) |
250 V |
0.25 x 1.252 in (6.35 x 31.8 mm) |
1.252 in (31.8 mm) |
CE; CSA; PSE; UL |
125 °C (257 °F) |
Fast |
|||||||||||||
|
Bel Fuse |
Electric Fuse |
Inline/Holder |
250 V |
100 mA |
End Cap |
30 mJ |
-55 °C (-67 °F) |
Nickel |
35 A |
Bulk; Tape And Reel |
0.201 in (5.1 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.201 x 0.787 in (5.1 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; SEMKO; UL; VDE |
125 °C (257 °F) |
Time Lag |
||||||||||||
|
Bel Fuse |
Electric Fuse |
Inline/Holder |
250 V |
500 mA |
End Cap |
1.4 J |
-55 °C (-67 °F) |
Nickel |
35 A |
Bulk; Tape And Reel |
0.201 in (5.1 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.201 x 0.787 in (5.1 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; SEMKO; UL; VDE |
125 °C (257 °F) |
Time Lag |
||||||||||||
|
Schurter Ag |
Electric Fuse |
Through Hole Mount |
250 V |
2 A |
Wire |
32 J |
-20 °C (-4 °F) |
35 A |
Bulk |
0.154 in (3.9 mm) |
20 ms |
0.142 x 0.394 in (3.6 x 10 mm) |
0.154 x 0.433 in (3.9 x 11 mm) |
0.433 in (11 mm) |
CQC; CUL; UL; VDE |
70 °C (158 °F) |
Time Lag |
|||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
250 mA |
End Cap |
2 mJ |
Nickel |
35 A |
2 m |
Pre Arcing Time: Open within 120 s at 200% Rated Current |
0.25 in (6.35 mm) |
250 V |
3AB |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CSA; UL |
Fast |
||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
1 A |
End Cap |
1.615 J |
35 A |
1.615 |
0.25 in (6.35 mm) |
250 V |
0.248 x 1.26 in (6.3 x 32 mm) |
0.248 x 1.26 in (6.3 x 32 mm) |
1.25 in (31.75 mm) |
CSA; UL |
Fast |
||||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
250 mA |
End Cap |
14.8 mJ |
Nickel |
35 A |
0.25 in (6.35 mm) |
32 V |
0.248 x 1.26 in (6.3 x 32 mm) |
0.248 x 1.26 in (6.3 x 32 mm) |
1.25 in (31.75 mm) |
CSA; UL |
Fast |
||||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
10 A |
End Cap |
Nickel |
200 A |
Pre Arcing Time: OPEN within 2 MIN at 200% RATED CURRENT |
0.25 in (6.35 mm) |
250 V |
0.248 x 1 in (6.3 x 25.4 mm) |
0.252 x 1 in (6.4 x 25.4 mm) |
1 in (25.4 mm) |
CUL |
Fast |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
800 mA |
End Cap |
6.6 J |
Nickel |
35 A |
Pre Arcing Time: Open within 5 s at 200% Rated Current |
6.6 |
Box |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CSA; PSE/JET; UL |
Time Delay |
||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
250 mA |
End Cap |
14.8 mJ |
Nickel |
35 A |
Box |
0.25 in (6.35 mm) |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CSA; UL |
Fast |
||||||||||||||||
Eaton Corporation |
Electric Fuse |
Through Hole Mount |
250 V |
2 A |
Pin Wire |
27 J |
-55 °C (-67 °F) |
100 A |
3 s |
Pre Arcing Time: Open within 3 s at 200% Rated Current |
Bulk |
0.205 in (5.2 mm) |
250 V |
3 s |
0.197 x 0.591 in (5 x 15 mm) |
0.591 in (15 mm) |
CSA, UL |
85 °C (185 °F) |
Time Delay |
||||||||||||
|
Eaton Corporation |
Electric Fuse |
Through Hole Mount |
250 V |
750 mA |
Pin Wire |
9.162 J |
Tin |
35 A |
Pre Arcing Time: Open within 3 s at 200% Rated Current |
Box |
0.217 in (5.5 mm) |
e3 |
250 V |
0.197 x 0.591 in (5 x 15 mm) |
0.217 x 0.598 in (5.5 x 15.2 mm) |
0.598 in (15.2 mm) |
CSA; UL |
Time Delay |
||||||||||||
|
Cooper Industries |
Electric Fuse |
Inline/Holder |
250 V |
800 mA |
End Cap |
6.6 J |
Nickel |
35 A |
6.6 |
Box |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CSA; UL |
Time Delay |
|||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
2.5 A |
End Cap |
31.79 J |
Nickel |
200 A |
2 m |
Rated Breaking Capacity at 125 VDC: 10000 A |
Box |
0.25 in (6.35 mm) |
250 V |
3AB |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CSA, UL |
Time Delay |
|||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
1.25 A |
End Cap |
10.05 J |
Nickel |
35 A |
10.05 |
Bulk |
0.205 in (5.2 mm) |
250 V |
20 ms |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
BSI; CCC; CSA; IMQ; PSE; SEMKO; UL; VDE |
Time Delay |
||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
125 mA |
End Cap |
63 mJ |
Nickel |
35 A |
0.063 |
Bulk |
0.205 in (5.2 mm) |
250 V |
20 ms |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
BSI; CCC; CSA; IMQ; SEMKO; UL; VDE |
Time Delay |
||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
12.5 A |
End Cap |
1.02 kJ |
Nickel |
125 A |
1019.5 |
Bulk |
0.205 in (5.2 mm) |
250 V |
20 ms |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
PSE; UL |
Time Delay |
||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
2 A |
End Cap |
9.6 J |
-55 °C (-67 °F) |
Nickel |
1.5 kA |
9.6 |
Bulk |
0.205 in (5.2 mm) |
250 V |
10 ms |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
BSI, CCC, CSA, CUL, IMQ, KC, PSE, SEMKO, UL, VDE |
125 °C (257 °F) |
Time Delay |
A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.
Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.
In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.