250 V Fuses 2,400+

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

BK1/S505-2-R

Cooper Industries

Electric Fuse

Inline/Holder

250 V

2 A

End Cap

9.6 J

Nickel

1.5 kA

9.6

Bag

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

BSI; CCC/CQC; CSA; IEC; IMQ; KC; PSE/JET; SEMKO; UL; VDE

Time Delay

C308F-100MA-TR

Cooper Industries

Electric Fuse

Inline/Holder

250 V

250 V

100 mA

End Cap

870 μJ

Silver

4 kA

C308F

Tape And Reel

0.12 in (3.05 mm)

e4

0.12 x 0.343 in (3.05 x 8.7 mm)

0.343 in (8.7 mm)

EN; UL

Fast

C308F100MA-TR

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

250 V

100 mA

End Cap

870 μJ

Silver

4 kA

0.0008

Tape And Reel

0.12 in (3.05 mm)

e4

250 V

0.12 x 0.343 in (3.05 x 8.7 mm)

0.343 in (8.7 mm)

EN; UL

Fast

ECNR70

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

70 A

Tab/Blade

200 kA

Bulk

1.06 in (26.924 mm)

5.88 in (149.352 mm)

CE; CSA; UL

Time Delay

EYP2BH101

Panasonic

Thermal Fuse

Through Hole Mount

250 V

2 A

Wire

Tin

Bulk

0.197 in (5 mm)

0.087 in (2.2 mm)

e3

250 V

0.157 in (4 mm)

BEAB; CCC; CSA; PSE; UL; VDE

65 °C (149 °F)

FNM-1

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

1 A

End Cap

35 A

Box

0.406 in (10.3 mm)

250 V

Midget

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

FRN-R-1-1/4

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 V

1.25 A

End Cap

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

Box

0.56 in (14.22 mm)

RK5

250 V

0.563 x 2 in (14.3 x 50.8 mm)

2 in (50.8 mm)

CE; CSA; UL

Time Delay

GMC-1-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

1 A

End Cap

1.8 J

Nickel

35 A

Pre Arcing Time: OPEN within 2 MIN at 200% RATED CURRENT

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

CSA; KC; MITI; UL

Time Delay

GSA20

Mersen S A

Electric Fuse

Inline/Holder

250 V

20 A

End Cap

400 A

0.25 in (6.35 mm)

125 V

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA; UL

Time Delay

MC3E1-5NBS

Mersen S A

Electric Fuse

Panel Mount

250 V

3 A

Quick Connect

3 A

Bulk

1.811 in (46 mm)

1.039 in (26.4 mm)

Indicator

1.89 in (48 mm)

MDL-1-1/2-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

1.5 A

End Cap

22.7 J

Nickel

100 A

0.25 in (6.35 mm)

250 V

0.252 x 1.248 in (6.4 x 31.7 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; UL

Time Delay

PCC-2-R

Eaton Corporation

Electric Fuse

Through Hole Mount

250 V

450 V

2 A

Pin Wire

200 mJ

50 A

10 s

Rated Breaking Capacity at 450 VDC: 300 A

250 V

0.35 x 0.184 x 0.345 in (8.89 x 4.67 x 8.76 mm)

CUL; UL

Fast

S500-3.15-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

3.15 A

End Cap

13 J

Nickel

35 A

0.205 in (5.2 mm)

250 V

10 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

BSI; CCC; CSA; CUL; IMQ; SEMKO; UL; VDE

Fast

S500-315-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

315 mA

End Cap

580 mJ

Nickel

35 A

0.205 in (5.2 mm)

250 V

10 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

BSI; CCC; CSA; CUL; IMQ; SEMKO; UL; VDE

Fast

SF-2410SP050W-2

Bourns

Electric Fuse

Surface Mount

250 V

500 mA

Wraparound

110 mJ

-55 °C (-67 °F)

Tin Over Nickel

100 A

1 ms

Tape And Reel, 7 inch

0.24 in (6.1 mm)

0.098 in (2.49 mm)

2410

0.085 in (2.16 mm)

UL; VDE

125 °C (257 °F)

Time Lag

SS-5-4A-BK

Eaton Corporation

Electric Fuse

Through Hole Mount

250 V

4 A

Pin Wire

87 J

-40 °C (-40 °F)

Tin

40 A

87

Bag

0.335 in (8.5 mm)

0.169 in (4.3 mm)

e3

250 V

0.335 x 0.169 x 0.329 in (8.5 x 4.3 x 8.35 mm)

0.329 in (8.35 mm)

CQC; EK; PSE; SEMKO; UL; VDE

125 °C (257 °F)

Time Delay

TR1/C515-750MA

Eaton Corporation

Electric Fuse

Through Hole Mount

250 V

750 mA

Pin Wire

2.7 J

-55 °C (-67 °F)

35 A

3 s

Pre Arcing Time: Open within 3 s at 200% Rated Current

Tape And Reel

0.205 in (5.2 mm)

250 V

3 s

0.197 x 0.591 in (5 x 15 mm)

0.591 in (15 mm)

CSA, UL

85 °C (185 °F)

Time Delay

TR2/C515S-2.25-R

Eaton Corporation

Electric Fuse

Through Hole Mount

250 V

2.25 A

Pin Wire

97.724 J

-55 °C (-67 °F)

Tin

100 A

3 s

Pre Arcing Time: Open within 3 s at 200% Rated Current

Tape And Reel

0.217 in (5.5 mm)

e3

250 V

3 s

0.197 x 0.591 in (5 x 15 mm)

0.217 x 0.598 in (5.5 x 15.2 mm)

0.598 in (15.2 mm)

CSA, UL

85 °C (185 °F)

Time Delay

TRP1-4/10R

Mersen S A

Electric Fuse

Inline/Holder

250 V

250 V

1.4 A

End Cap

200 kA

Rated Breaking Capacity at 250 VDC: 20 A

0.551 in (14 mm)

2.008 in (51 mm)

CSA; UL

Time Delay

0001.2512.PT

Schurter Ag

Electric Fuse

Through Hole Mount

250 V

150 V

6.3 A

Pin Wire

171 J

-55 °C (-67 °F)

Tin

1.5 kA

Bulk

0.213 in (5.4 mm)

e3

10 ms

0.213 x 0.886 in (5.4 x 22.5 mm)

0.213 x 0.886 in (5.4 x 22.5 mm)

0.886 in (22.5 mm)

CUL; UL

125 °C (257 °F)

Time Lag

0001.2514G

Schurter Ag

Electric Fuse

Inline/Holder

250 V

150 V

10 A

End Cap

400 J

-55 °C (-67 °F)

Nickel

1 kA

Rated Breaking Capacity at 150 VDC: 1500 A

Bulk

0.205 in (5.2 mm)

10 ms

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

CCC; CUL; METI; UL; VDE

125 °C (257 °F)

Time Lag

0001.2514.G

Schurter Ag

Electric Fuse

Inline/Holder

250 V

150 V

10 A

End Cap

400 J

-55 °C (-67 °F)

Nickel

1 kA

400

Bulk

0.205 in (5.2 mm)

10 ms

0.205 x 0.787 in (5.2 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CUL; METI; UL; VDE

125 °C (257 °F)

Time Lag

0034.1527

Schurter Ag

Electric Fuse

Inline/Holder

250 V

32 mA

End Cap

82 μJ

-55 °C (-67 °F)

Nickel

100 A

Box

0.205 in (5.2 mm)

20 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CUL; VDE; UL

125 °C (257 °F)

Very Fast

02131.25MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

1.25 A

End Cap

27.15 J

-55 °C (-67 °F)

Nickel

35 A

20 ms

27.15

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.228 x 0.886 in (5.8 x 22.5 mm)

0.787 in (20 mm)

CCC; CE; CSA; PSE; SEMKO; SEV; UL; VDE

125 °C (257 °F)

Time Lag

0216.200HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

200 mA

End Cap

4.39 mJ

-55 °C (-67 °F)

Tin

1.5 kA

0.0043

Bulk

0.205 in (5.2 mm)

e3

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; SEMKO; UL; VDE

125 °C (257 °F)

Fast

0218005.HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

5 A

End Cap

111 J

-55 °C (-67 °F)

Nickel

50 A

20 ms

111

Bulk

0.205 in (5.2 mm)

Supplemental

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; KC; PSE; SEMKO; UL; VDE

125 °C (257 °F)

Time Lag

0234005.MXEP

Littelfuse

Electric Fuse

Through Hole Mount

250 V

5 A

Pin Wire

20.645 J

-55 °C (-67 °F)

Tin

200 A

400 ms

20.645

Bulk

0.217 in (5.5 mm)

e3

250 V

0.197 x 0.787 in (5 x 20 mm)

0.217 x 0.846 in (5.5 x 21.5 mm)

0.846 in (21.5 mm)

CE; CSA; PSE; UL

125 °C (257 °F)

Medium

0313005.VXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

5 A

End Cap

140 J

-55 °C (-67 °F)

Nickel

200 A

Bulk

0.25 in (6.35 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; KTL; PSE; UL

125 °C (257 °F)

Time Lag

031303.2MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

3.2 A

End Cap

209 J

-60 °C (-76 °F)

Nickel

100 A

5 s

209

Bulk

0.25 in (6.35 mm)

Supplemental

250 V

3AG

1.25 x 0.25 in (31.75 x 6.35 mm)

1.25 in (31.75 mm)

CE; CSA; KC; PSE; UL

125 °C (257 °F)

Time Lag

032603.2MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

3.2 A

End Cap

214 J

-55 °C (-67 °F)

Nickel

100 A

5 s

214

Bulk

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; KC; PSE; UL

125 °C (257 °F)

Time Delay

313005P

Littelfuse

Electric Fuse

Inline/Holder

250 V

5 A

End Cap

140 J

200 A

0.25 in (6.35 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; METI; PSE; UL

Slow

3403.0129.24

Schurter Ag

Electric Fuse

Surface Mount

250 V

125 V

750 mA

Wraparound

360 mJ

-40 °C (-40 °F)

Tin

100 A

Tape And Reel, 13 inch

0.433 in (11 mm)

0.181 in (4.6 mm)

e3

5 ms

0.433 x 0.181 in (11 x 4.6 mm)

0.433 x 0.181 x 0.154 in (11 x 4.6 x 3.9 mm)

0.154 in (3.9 mm)

CUL, UL

125 °C (257 °F)

Time Lag

37013150000

Littelfuse

Electric Fuse

Through Hole Mount

250 V

3.15 A

Pin Wire

3.1 J

-40 °C (-40 °F)

Tin

35 A

20 ms

Ammo Pack; Tape

0.335 in (8.5 mm)

e3

250 V

TR5

0.335 x 0.315 in (8.5 x 8 mm)

0.315 in (8 mm)

CCC; CE; CUL; PSE; UL; VDE

85 °C (185 °F)

Fast

7100.1171.95

Schurter Ag

Electric Fuse

Through Hole Mount

250 V

4 A

Pin Wire

4.1 J

-40 °C (-40 °F)

Tin

63 A

Tape And Reel, 14 inch

0.453 in (11.5 mm)

0.197 in (5 mm)

e3

1 ms

0.453 x 0.197 in (11.5 x 5 mm)

0.453 x 0.197 x 0.315 in (11.5 x 5 x 8 mm)

0.315 in (8 mm)

CUL; UL

85 °C (185 °F)

Very Fast

7100.1171.96

Schurter Ag

Electric Fuse

Through Hole Mount

250 V

4 A

Pin Wire

4.1 J

-40 °C (-40 °F)

Tin

63 A

Tape And Reel, 14 inch

0.453 in (11.5 mm)

0.197 in (5 mm)

e3

1 ms

0.453 x 0.197 in (11.5 x 5 mm)

0.453 x 0.197 x 0.315 in (11.5 x 5 x 8 mm)

0.315 in (8 mm)

CUL; UL

85 °C (185 °F)

Very Fast

ABC-5-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 V

5 A

End Cap

32.83 J

Nickel

200 A

2 m

Pre Arcing Time: Open within 120 s at 200% Rated Current

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA; UL

Fast

AGC-4-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

4 A

End Cap

86.56 J

-55 °C (-67 °F)

Nickel

200 A

Pre Arcing Time: Open within 120 s at 200% Rated Current

0.0305

Box

0.25 in (6.35 mm)

250 V

0.248 x 1.26 in (6.3 x 32 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA; UL

125 °C (257 °F)

Fast

GDB-10A

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

10 A

End Cap

100 A

0.205 in (5.2 mm)

250 V

10 ms

0.197 x 0.787 in (5 x 20 mm)

0.218 x 0.831 in (5.54 x 21.1 mm)

0.787 in (20 mm)

UL; VDE

Fast

NON-200

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 V

200 A

Tab/Blade

10 kA

Rated Breaking Capacity at 125 VDC: 10000 A

Box

1.56 in (39.62 mm)

H

250 V

1.56 x 7.13 in (39.62 x 181.1 mm)

7.13 in (181.1 mm)

CE; CSA; UL

SF139E-1

Nec

Thermal Fuse

Through Hole Mount

250 V

10 A

Wire

0.165 in (4.2 mm)

0.433 in (11 mm)

BEAB; CSA; UL; VDE

139 °C (282.2 °F)

37213150411

Littelfuse

Electric Fuse

Through Hole Mount

250 V

3.15 A

Pin Wire

77.395 J

-40 °C (-40 °F)

Matte Tin

35 A

20 ms

60

Bulk

0.335 in (8.5 mm)

e3

250 V

TR5

0.335 x 0.315 in (8.5 x 8 mm)

0.315 in (8 mm)

CCC; CE; CUL; KC; PSE; UL; VDE

85 °C (185 °F)

Time Lag

37012000410

Littelfuse

Electric Fuse

Through Hole Mount

250 V

2 A

Pin Wire

980 mJ

-40 °C (-40 °F)

Matte Tin

35 A

20 ms

Ammo Pack; Tape

0.335 in (8.5 mm)

e3

250 V

TR5

0.335 x 0.315 in (8.5 x 8 mm)

0.315 in (8 mm)

CCC; CE; CUL; PSE; UL; VDE

85 °C (185 °F)

Fast

37212000411

Littelfuse

Electric Fuse

Through Hole Mount

250 V

2 A

Pin Wire

30 J

-40 °C (-40 °F)

Matte Tin

35 A

20 ms

23

Bulk

0.335 in (8.5 mm)

e3

250 V

TR5

0.335 x 0.315 in (8.5 x 8 mm)

0.315 in (8 mm)

CCC; CE; CUL; KC; PSE; UL; VDE

85 °C (185 °F)

Time Lag

SR-5-1A-BK

Eaton Corporation

Electric Fuse

Through Hole Mount

250 V

1 A

Pin Wire

7.5 J

-40 °C (-40 °F)

35 A

Bag

0.335 in (8.5 mm)

20 ms

0.335 x 0.319 in (8.5 x 8.1 mm)

0.319 in (8.1 mm)

CCC; CUL; KC; PSE; SEMKO; UL; VDE

125 °C (257 °F)

Time Delay

044301.5DR

Littelfuse

Electric Fuse

Surface Mount

250 V

125 V

1.5 A

Wraparound

14.72 J

-55 °C (-67 °F)

Silver

50 A

2 m

Rated Breaking Capacity at 125 VDC: 100 A

14.72

Tape And Reel

0.397 in (10.08 mm)

0.12 in (3.05 mm)

e4

250 V

0.398 x 0.123 x 0.123 in (10.1 x 3.12 x 3.12 mm)

0.12 in (3.05 mm)

CUL; IEC; PSE; TUV; UL

125 °C (257 °F)

Slow

0218008.HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

8 A

End Cap

341.5 J

-55 °C (-67 °F)

Nickel

80 A

341.5

Bulk

0.205 in (5.2 mm)

Supplemental

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; CSA; IEC; KC; PSE; UL; VDE

125 °C (257 °F)

Time Lag

0313010.MX250P

Littelfuse

Electric Fuse

Inline/Holder

250 V

10 A

End Cap

760 J

-55 °C (-67 °F)

Nickel

300 A

Bulk

1.25 in (31.75 mm)

1.25 x 0.25 in (31.75 x 6.35 mm)

0.25 in (6.35 mm)

CE; CSA; PSE; UL

125 °C (257 °F)

Time Lag

0215012.MXEP

Littelfuse

Electric Fuse

Through Hole Mount

250 V

250 V

12 A

Pin Wire

515.5 J

-55 °C (-67 °F)

Matte Tin

1.5 kA

10 ms

Pre Arcing Time: Open within 10 ms at 1000% Rated Current

515.5

Bulk

0.228 in (5.8 mm)

e3

250 V

0.197 x 0.787 in (5 x 20 mm)

0.228 x 0.886 in (5.8 x 22.5 mm)

0.886 in (22.5 mm)

CE; IEC; CSA; KC; PSE; SEMKO; UL

125 °C (257 °F)

Time Lag

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.