600 V Fuses 2,400+

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

KLDR.250HXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

250 mA

End Cap

13.8 mJ

Nickel

200 kA

12 s

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

0JLS110.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

110 A

Tab/Blade

200 kA

Bulk

1.5 in (38.1 mm)

J

600 V

3 x 3 in (76.2 x 76.2 mm)

3 in (76.2 mm)

CE; CSA; QPL; UL

Fast

IDSR300ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

300 A

200 kA

IDSR

Rated Breaking Capacity at 600 VDC: 20000 A

Indicator

CSA; UL

Time Delay

LLSRK110ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

110 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

1.843 in (46.8 mm)

Indicator

1.843 x 9.626 in (46.8 x 244.5 mm)

9.626 in (244.5 mm)

CSA; UL

Time Delay

KLLU3500

Littelfuse

Electric Fuse

Inline/Holder

600 V

3.5 kA

Tab/Blade

200 kA

5.752 in (146.1 mm)

L

600 V

5.752 x 4 in (146.1 x 101.6 mm)

4 in (101.6 mm)

CSA; UL

Time Delay

0JLS020.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

20 A

End Cap

200 kA

0.811 in (20.6 mm)

J

600 V

0.811 x 2.252 in (20.6 x 57.2 mm)

2.252 in (57.2 mm)

CE; CSA; QPL; UL

Fast

LDC0500

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

500 A

Tab/Blade

200 kA

Rated Breaking Capacity at 600 VDC: 50000

2.5 in (63.5 mm)

2.5 x 3.752 in (63.5 x 95.3 mm)

3.752 in (95.3 mm)

CSA; UL

Time Delay

IDSR.600

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

600 mA

End Cap

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

0.752 x 5 in (19.1 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

IDSR045

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

45 A

End Cap

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

1.063 in (27 mm)

1 x 5.5 in (25.4 x 139.7 mm)

5.5 in (139.7 mm)

CSA; UL

Time Delay

LGD30

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

30 A

End Cap

200 kA

LGD

Rated Breaking Capacity at 300 VDC: 20000 A

CSA; IEC; UL

Time Delay

KLKR01.5

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

1.5 A

Tab/Blade

Nickel

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE, CSA, UL

Fast

FLSR035

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

35 A

200 kA

FLSR

Rated Breaking Capacity at 300 VDC: 20000 A

1.063 in (27 mm)

5.5 in (139.7 mm)

CSA; UL

Time Delay

2CO006

Littelfuse

Electric Fuse

Inline/Holder

600 V

250 V

6 A

Tab/Blade

200 kA

2CO

Rated Breaking Capacity at 250 VDC: 80000 A

0.827 in (21 mm)

0.827 x 2.205 in (21 x 56 mm)

2.205 in (56 mm)

CSA

CCMR004

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

4 A

End Cap

1.87 kJ

200 kA

Rated Breaking Capacity at 250 VDC: 20000 A

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

KLDR010

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

10 A

End Cap

132 J

200 kA

12 s

Rated Breaking Capacity at 300 VDC: 20000 A

0.406 in (10.3 mm)

CC

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

JLLS015.TXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

15 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.563 in (14.3 mm)

600 V

1.5 in (38.1 mm)

CE; CSA; UL

Fast

KLC10

Littelfuse

Electric Fuse

Inline/Holder

600 V

10 A

Tab/Blade

200 kA

0.563 in (14.3 mm)

0.563 x 1.874 in (14.3 x 47.6 mm)

1.874 in (47.6 mm)

CSA; UL

Fast

L60S10

Littelfuse

Electric Fuse

Inline/Holder

600 V

10 A

End Cap

200 kA

0.811 in (20.6 mm)

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; UL

Fast

CCMR.500TXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

500 mA

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

KLKR003

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

3 A

Tab/Blade

Nickel

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE, CSA, UL

Fast

CCMR.800

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

800 mA

End Cap

200 kA

Rated Breaking Capacity at 500 VDC: 20000 A

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

JLLS150.XXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

150 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

1.079 in (27.4 mm)

600 V

1.657 in (42.1 mm)

CE; CSA; UL

Fast

LLSRK110

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

110 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

1.843 in (46.8 mm)

1.843 x 9.626 in (46.8 x 244.5 mm)

9.626 in (244.5 mm)

CSA; UL

Time Delay

KLDR2.25HXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

2.25 A

End Cap

1.126 J

Nickel

200 kA

12 s

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

KLDR02.8HXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

2.8 A

End Cap

21.28 J

Nickel

200 kA

12 s

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

KLK4

Littelfuse

Electric Fuse

Inline/Holder

600 V

4 A

End Cap

100 kA

0.406 in (10.31 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; QPL; UL

Fast

FLSR03.2ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

3.2 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

Indicator

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; QPL; UL

Time Delay

FLSR70ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

70 A

Tab/Blade

200 kA

1.311 in (33.3 mm)

Indicator

1.311 x 7.874 in (33.3 x 200 mm)

7.874 in (200 mm)

CSA; UL

Time Delay

KLC125

Littelfuse

Electric Fuse

Inline/Holder

600 V

125 A

Tab/Blade

-55 °C (-67 °F)

200 kA

1.5 in (38.1 mm)

1.5 x 2.843 in (38.1 x 72.2 mm)

2.843 in (72.2 mm)

CSA; UL

125 °C (257 °F)

Very Fast

LLSRK600ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

600 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

3.094 in (78.6 mm)

Indicator

3.094 x 13.374 in (78.6 x 339.7 mm)

13.374 in (339.7 mm)

CSA; UL

Time Delay

KLKD001.HXR

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

1 A

End Cap

8 mJ

-55 °C (-67 °F)

100 kA

4 m

0.406 in (10.31 mm)

600 V

0.394 x 1.496 in (10 x 38 mm)

1.5 x 0.406 x 1.5 in (38.1 x 10.31 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL

125 °C (257 °F)

Fast

CCMR020.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

20 A

End Cap

200 kA

CCMR

Rated Breaking Capacity at 500 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

0LDC2000.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

2 kA

Tab/Blade

200 kA

16 ms

Rated Breaking Capacity at 600 VDC: 50000 A

3.5 in (88.9 mm)

L

600 V

3.5 x 3.752 in (88.9 x 95.3 mm)

3.752 in (95.3 mm)

CE, CSA, UL

Fast

KLPC2200

Littelfuse

Electric Fuse

Inline/Holder

600 V

480 V

2.2 kA

Tab/Blade

200 kA

Rated Breaking Capacity at 480 VDC: 20000 A

5 in (127 mm)

5 x 4 in (127 x 101.6 mm)

4 in (101.6 mm)

CSA; UL

Time Delay

07945810195

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

750 mA

End Cap

234 mJ

-55 °C (-67 °F)

100 kA

63 µs

Rated Breaking Capacity at 600 VDC: 50000 A

Bulk

0.406 in (10.31 mm)

170 µs

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA, UL

125 °C (257 °F)

Fast

2CM080

Littelfuse

Electric Fuse

Inline/Holder

600 V

250 V

80 A

Tab/Blade

200 kA

2CM

Rated Breaking Capacity at 250 VDC: 80000 A

1.22 in (31 mm)

1.22 x 2.598 in (31 x 66 mm)

2.598 in (66 mm)

CSA

LDC0200

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

200 A

Tab/Blade

200 kA

Rated Breaking Capacity at 600 VDC: 50000

2.5 in (63.5 mm)

2.5 x 3.752 in (63.5 x 95.3 mm)

3.752 in (95.3 mm)

CSA; UL

Time Delay

2CM350

Littelfuse

Electric Fuse

Inline/Holder

600 V

250 V

350 A

Tab/Blade

200 kA

2CM

Rated Breaking Capacity at 250 VDC: 80000 A

2.283 in (58 mm)

2.283 x 3.189 in (58 x 81 mm)

3.189 in (81 mm)

CSA

IDSR350ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

350 A

200 kA

IDSR

Rated Breaking Capacity at 600 VDC: 20000 A

Indicator

CSA; UL

Time Delay

JTD4ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

4 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

Indicator

2.252 in (57.2 mm)

CSA; UL

Time Delay

KLKD006.H

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

6 A

End Cap

35 mJ

-55 °C (-67 °F)

100 kA

4 m

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL; VDE

125 °C (257 °F)

Fast

FLSR.300ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

300 mA

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; QPL; UL

Time Delay

KLDR.300T

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

300 mA

End Cap

200 kA

KLDR

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

RLS200

Littelfuse

Electric Fuse

Inline/Holder

600 V

200 A

Tab/Blade

10 kA

1.843 in (46.8 mm)

9.626 in (244.5 mm)

CE; CSA; UL

JTD01.8

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

1.8 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.811 in (20.6 mm)

2.252 in (57.2 mm)

CSA; UL

Time Delay

KLKD.100T

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

100 mA

End Cap

-55 °C (-67 °F)

100 kA

4 m

0.406 in (10.31 mm)

600 V

0.394 x 1.496 in (10 x 38 mm)

1.5 x 1.5 in (38.1 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL

125 °C (257 °F)

Fast

KLKR025

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

25 A

Tab/Blade

Nickel

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE, CSA, UL

Fast

KLDR020

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

20 A

End Cap

123.8 J

200 kA

12 s

Rated Breaking Capacity at 300 VDC: 20000 A

0.406 in (10.3 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.