600 V Fuses 2,400+

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

07945894349

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

2 A

Tab/Blade

2.379 J

-55 °C (-67 °F)

100 kA

145 µs

Rated Breaking Capacity at 600 VDC: 50000 A

Bulk

0.406 in (10.31 mm)

291 µs

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE; IEC; UL

125 °C (257 °F)

Fast

CCMR1.25

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

1.25 A

End Cap

200 kA

Rated Breaking Capacity at 250 VDC: 20000 A

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

JLLS070

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

70 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

0.811 x 1.642 in (20.6 x 41.7 mm)

1.642 in (41.7 mm)

CSA; UL

Fast

NLS020

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

20 A

End Cap

50 kA

Rated Breaking Capacity at 500 VDC; 20000

0.811 in (20.6 mm)

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; UL

IDSR02.8ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

2.8 A

200 kA

IDSR

Rated Breaking Capacity at 600 VDC: 20000 A

Indicator

CSA; UL

Time Delay

FLSR3.50

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

3.5 A

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

CSA; UL

Time Delay

KLK31/2

Littelfuse

Electric Fuse

Inline/Holder

600 V

3.5 A

End Cap

100 kA

0.406 in (10.31 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Fast

JLLS110

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

110 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

1.063 in (27 mm)

1.063 x 1.657 in (27 x 42.1 mm)

1.657 in (42.1 mm)

CSA; UL

Fast

FLSR.250ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

250 mA

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; QPL; UL

Time Delay

FT600-0500-2

Littelfuse

Electric Fuse

Surface Mount

600 V

500 mA

Wraparound

1 J

250 A

FT600

Tape And Reel

0.134 in (3.4 mm)

0.134 in (3.4 mm)

0.134 x 0.134 x 0.413 in (3.4 x 3.4 x 10.5 mm)

0.413 in (10.5 mm)

CSA; UL

LLSRK.100ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

100 mA

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

BLS1-6/10

Littelfuse

Electric Fuse

Inline/Holder

600 V

1.6 A

End Cap

10 kA

0.406 in (10.31 mm)

0.406 x 1.375 in (10.31 x 34.93 mm)

1.375 in (34.93 mm)

CSA; UL

Fast

0477.500MX6EP

Littelfuse

Electric Fuse

Through Hole Mount

600 V

400 V

500 mA

Pin Wire

300 mJ

-55 °C (-67 °F)

Tin

100 A

Rated Breaking Capacity at 400 VDC: 1500 A

Bulk

0.236 in (6 mm)

e3

0.236 x 0.886 in (6 x 22.5 mm)

0.886 in (22.5 mm)

UL

125 °C (257 °F)

Time Delay

KLPC1600.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

480 V

1.6 kA

Tab/Blade

200 kA

10.752 in (273.1 mm)

L

600 V

10.752 x 3.752 in (273.1 x 95.3 mm)

3.752 in (95.3 mm)

CE; CSA; UL

Time Lag

LLSRK225ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

225 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

2.594 in (65.9 mm)

Indicator

2.594 x 11.626 in (65.9 x 295.3 mm)

11.626 in (295.3 mm)

CSA; UL

Time Delay

KLKD03.5

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

3.5 A

End Cap

-55 °C (-67 °F)

100 kA

4 m

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL; VDE

125 °C (257 °F)

Fast

KLK9

Littelfuse

Electric Fuse

Inline/Holder

600 V

9 A

End Cap

100 kA

0.406 in (10.31 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; QPL; UL

Fast

KLPC0500

Littelfuse

Electric Fuse

Inline/Holder

600 V

480 V

500 A

Tab/Blade

200 kA

Rated Breaking Capacity at 480 VDC: 20000 A

2.5 in (63.5 mm)

2.5 x 3.752 in (63.5 x 95.3 mm)

3.752 in (95.3 mm)

CSA; UL

Time Delay

JLLS002.TXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

2 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.563 in (14.3 mm)

600 V

1.5 in (38.1 mm)

CE; CSA; UL

Fast

LLSRK1.60

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

1.6 A

End Cap

20 kA

Rated Breaking Capacity at 300 VDC: 20000

0.811 in (20.6 mm)

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

Time Delay

JLS100

Littelfuse

Electric Fuse

Inline/Holder

600 V

100 A

Tab/Blade

200 kA

Bulk

1 in (25.4 mm)

1 x 2.626 in (25.4 x 66.7 mm)

2.626 in (66.7 mm)

CE; CSA; QPL; UL

Fast

07945814858

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

500 mA

Tab/Blade

-55 °C (-67 °F)

100 kA

Rated Breaking Capacity at 600 VDC: 50000 A

Bulk

0.406 in (10.31 mm)

141 µs

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE, UL

125 °C (257 °F)

Fast

FLSR.400T

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

400 mA

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

5 in (127 mm)

CSA; UL

Time Delay

LGD10

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

10 A

End Cap

200 kA

LGD

Rated Breaking Capacity at 300 VDC: 20000 A

CSA; IEC; UL

Time Delay

CCMR025

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

25 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

FLSR6.25T

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

6.25 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

5 in (127 mm)

CSA; UL

Time Delay

FLSR50ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

50 A

End Cap

200 kA

1.063 in (27 mm)

Indicator

1.063 x 5.5 in (27 x 139.7 mm)

5.5 in (139.7 mm)

CSA; UL

Time Delay

KLSR070

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

70 A

Tab/Blade

200 kA

KLSR

Rated Breaking Capacity at 300 VDC: 20000 A

1.311 in (33.3 mm)

7.874 in (200 mm)

CSA; UL

Fast

KLKD2-R

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

2 A

Tab/Blade

2.379 J

-55 °C (-67 °F)

100 kA

145 µs

Rated Breaking Capacity at 600 VDC: 50000 A

Bulk

0.406 in (10.31 mm)

291 µs

0.394 x 1.496 in (10 x 38 mm)

0.406 x 1.53 in (10.31 x 38.86 mm)

1.5 in (38.1 mm)

CE; IEC; UL

125 °C (257 °F)

Fast

0KLK02.5T

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

2.5 A

End Cap

100 kA

Rated Breaking Capacity at 500 VDC: 50000 A

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Fast

KLSR050

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

50 A

End Cap

200 kA

KLSR

Rated Breaking Capacity at 300 VDC: 20000 A

1.063 in (27 mm)

5.5 in (139.7 mm)

CSA; UL

Fast

KLPC350.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

480 V

350 A

Tab/Blade

200 kA

8.626 in (219.1 mm)

L

600 V

8.626 x 3.752 in (219.1 x 95.3 mm)

3.752 in (95.3 mm)

CE; CSA; UL

Time Lag

CCMR009.TXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

9 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

LLSRK.250

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

250 mA

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

LDC2000

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

2 kA

Tab/Blade

200 kA

16 ms

Rated Breaking Capacity at 600 VDC: 50000 A

3.5 in (88.9 mm)

3.5 x 3.752 in (88.9 x 95.3 mm)

3.752 in (95.3 mm)

CE, CSA, UL

Fast

L60S030

Littelfuse

Electric Fuse

Inline/Holder

600 V

30 A

End Cap

-55 °C (-67 °F)

200 kA

0.811 in (20.6 mm)

5 in (127 mm)

CSA; UL

125 °C (257 °F)

Very Fast

SLC010

Littelfuse

Electric Fuse

Inline/Holder

600 V

10 A

End Cap

100 kA

0.406 in (10.3 mm)

0.406 x 1.311 in (10.3 x 33.3 mm)

1.311 in (33.3 mm)

CSA; UL

Medium Time Delay

KLKD004.H

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

4 A

End Cap

19 mJ

-55 °C (-67 °F)

100 kA

4 m

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL; VDE

125 °C (257 °F)

Fast

JLS450

Littelfuse

Electric Fuse

Inline/Holder

600 V

450 A

Tab/Blade

200 kA

Bulk

2.5 in (63.5 mm)

2.5 x 3.752 in (63.5 x 95.3 mm)

3.752 in (95.3 mm)

CE; CSA; QPL; UL

Fast

2CC350

Littelfuse

Electric Fuse

Inline/Holder

600 V

250 V

350 A

Tab/Blade

200 kA

2CC

Rated Breaking Capacity at 250 VDC: 80000 A

2.283 in (58 mm)

2.283 x 3.189 in (58 x 81 mm)

3.189 in (81 mm)

CSA

KLKD1/10

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

100 mA

End Cap

-55 °C (-67 °F)

100 kA

Rated Breaking Capacity at 600 VDC: 50000 A

Bulk

0.406 in (10.31 mm)

47 µs

0.394 x 1.496 in (10 x 38 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA, UL

125 °C (257 °F)

Fast

IDSR225.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

2.25 A

End Cap

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

5 in (127 mm)

CSA; UL

Time Delay

KLDR.800H

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

800 mA

End Cap

200 kA

KLDR

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

LLSRK6.50

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

6.5 A

End Cap

20 kA

Rated Breaking Capacity at 300 VDC: 20000

0.811 in (20.6 mm)

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

Time Delay

KLDR.200T

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

200 mA

End Cap

200 kA

KLDR

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

LA60Q20-2

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

20 A

End Cap

330 J

200 kA

Rated Breaking Capacity at 600 VDC: 100000 A

0.406 in (10.32 mm)

0.406 x 1.5 in (10.32 x 38.1 mm)

1.5 in (38.1 mm)

UL

Very Fast

KLDR03.5T

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

3.5 A

End Cap

200 kA

KLDR

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

KLKD1/10-R

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

100 mA

Tab/Blade

-55 °C (-67 °F)

100 kA

Rated Breaking Capacity at 600 VDC: 50000 A

Bulk

0.406 in (10.31 mm)

47 µs

0.394 x 1.496 in (10 x 38 mm)

0.406 x 1.53 in (10.31 x 38.86 mm)

1.5 in (38.1 mm)

CE, UL

125 °C (257 °F)

Fast

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.