Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Nominal Joule Integral | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Pre Arcing Rating (A2/s) | Packing Method | Body Length/Diameter | Body Width | Fuse Class | JESD-609 Code | Rated Voltage | Resistance | Minimum Pre Arcing Time | Fuse Size | Built-in Features | Dimensions | Body Height | Reference Standard | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
700 V |
40 A |
End Cap |
84 J |
200 kA |
Rated Breaking Capacity at 700 VDC: 50000 A |
Box |
0.563 in (14.3 mm) |
0.563 x 2 in (14.3 x 50.8 mm) |
2 in (50.8 mm) |
IEC; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
500 V |
40 A |
End Cap |
68 J |
200 kA |
Rated Breaking Capacity at 500 VDC: 50000 A |
Box |
0.874 in (22.2 mm) |
0.874 x 2.283 in (22.2 x 58 mm) |
2.283 in (58 mm) |
IEC; UL |
||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
700 V |
400 V |
60 A |
End Cap |
200 kA |
Rated Breaking Capacity at 400 VDC: 100000 A |
1.063 in (27 mm) |
Indicator |
1.063 x 2.362 in (27 x 60 mm) |
2.362 in (60 mm) |
Time Delay |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
700 V |
400 A |
Tab/Blade |
31 kJ |
50 kA |
Box |
2 in (50.8 mm) |
2 x 2.84 in (50.8 x 72.14 mm) |
2.84 in (72.136 mm) |
CE; CSA; UL |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
700 V |
50 A |
End Cap |
200 J |
200 kA |
Rated Breaking Capacity at 700 VDC: 50000 A |
Box |
0.563 in (14.3 mm) |
0.563 x 2 in (14.3 x 50.8 mm) |
2 in (50.8 mm) |
IEC; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
700 V |
150 A |
Tab/Blade |
2.9 kJ |
50 kA |
Box |
1.5 in (38.1 mm) |
1.5 x 2.84 in (38.1 x 72.14 mm) |
2.84 in (72.136 mm) |
CE; CSA; UL |
|||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
700 V |
400 V |
50 A |
End Cap |
200 kA |
Rated Breaking Capacity at 400 VDC: 100000 A |
1.063 in (27 mm) |
Indicator |
1.063 x 2.362 in (27 x 60 mm) |
2.362 in (60 mm) |
Time Delay |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
315 A |
Tab/Blade |
10 kJ |
200 kA |
Box |
2.126 in (54 mm) |
1.181 in (30 mm) |
Indicator |
2.126 x 1.181 x 2.008 in (54 x 30 x 51 mm) |
2.008 in (51 mm) |
CE; CSA; DIN 43653; IEC; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
500 V |
63 A |
End Cap |
280 J |
200 kA |
Rated Breaking Capacity at 500 VDC: 50000 A |
Box |
0.874 in (22.2 mm) |
0.874 x 2.283 in (22.2 x 58 mm) |
2.283 in (58 mm) |
IEC; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
700 V |
25 A |
End Cap |
44 J |
200 kA |
Rated Breaking Capacity at 700 VDC: 50000 A |
Box |
0.563 in (14.3 mm) |
0.563 x 2 in (14.3 x 50.8 mm) |
2 in (50.8 mm) |
CSA; IEC; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
700 V |
600 A |
Tab/Blade |
66.7 kJ |
50 kA |
Box |
2.5 in (63.5 mm) |
2.5 x 2.84 in (63.5 x 72.14 mm) |
2.84 in (72.136 mm) |
CE; CSA; UL |
|||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
700 V |
400 V |
20 A |
End Cap |
200 kA |
Rated Breaking Capacity at 400 VDC: 100000 A |
0.827 in (21 mm) |
Indicator |
0.827 x 2.244 in (21 x 57 mm) |
2.244 in (57 mm) |
Time Delay |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
700 V |
250 A |
Tab/Blade |
10.5 kJ |
50 kA |
Box |
2 in (50.8 mm) |
2 x 2.84 in (50.8 x 72.14 mm) |
2.84 in (72.136 mm) |
CE; CSA; UL |
|||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
700 V |
400 V |
100 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 400 VDC: 100000 A |
1.063 in (27 mm) |
Indicator |
1.142 x 2.638 in (29 x 67 mm) |
4.606 in (117 mm) |
Time Delay |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
700 V |
10 A |
End Cap |
3.6 J |
200 kA |
Rated Breaking Capacity at 700 VDC: 50000 A |
0.563 in (14.3 mm) |
Indicator |
0.563 x 2.008 in (14.3 x 51 mm) |
2.008 in (51 mm) |
CE; IEC; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
500 V |
32 A |
End Cap |
55 J |
200 kA |
Rated Breaking Capacity at 500 VDC: 50000 A |
Box |
0.874 in (22.2 mm) |
0.874 x 2.283 in (22.2 x 58 mm) |
2.283 in (58 mm) |
IEC; UL |
||||||||||||||||
|
Siba |
Electric Fuse |
Inline/Holder |
700 V |
500 V |
1.6 A |
End Cap |
310 mJ |
Nickel |
50 kA |
Rated Breaking Capacity at 500 VDC: 20000 A |
Bulk |
0.25 in (6.35 mm) |
1 ms |
0.25 x 1.252 in (6.35 x 31.8 mm) |
1.252 in (31.8 mm) |
CUL; UL |
Very Fast |
|||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
500 V |
50 A |
End Cap |
155 J |
200 kA |
Rated Breaking Capacity at 500 VDC: 50000 A |
Box |
0.874 in (22.2 mm) |
0.874 x 2.283 in (22.2 x 58 mm) |
2.283 in (58 mm) |
IEC; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
700 V |
300 A |
Tab/Blade |
17.6 kJ |
50 kA |
Box |
2 in (50.8 mm) |
2 x 2.84 in (50.8 x 72.14 mm) |
2.84 in (72.136 mm) |
CE; CSA; UL |
|||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
700 V |
400 V |
70 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 400 VDC: 100000 A |
1.063 in (27 mm) |
Indicator |
1.142 x 2.638 in (29 x 67 mm) |
4.606 in (117 mm) |
Time Delay |
|||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
700 V |
400 V |
40 A |
End Cap |
200 kA |
Rated Breaking Capacity at 400 VDC: 100000 A |
1.063 in (27 mm) |
Indicator |
1.063 x 2.362 in (27 x 60 mm) |
2.362 in (60 mm) |
Time Delay |
|||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
700 V |
700 V |
500 A |
Tab/Blade |
72 J |
200 kA |
Rated Breaking Capacity at 700 VDC: 100000 A;Joule Integral Nom at 700 VDC: 150 |
2 in (50.8 mm) |
2 x 2.843 in (50.8 x 72.2 mm) |
2.843 in (72.2 mm) |
CSA; UL |
|||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
700 V |
700 V |
500 A |
Tab/Blade |
72 J |
200 kA |
Rated Breaking Capacity at 700 VDC: 100000 A;Joule Integral Nom at 700 VDC: 150 |
2 in (50.8 mm) |
2 x 2.843 in (50.8 x 72.2 mm) |
2.843 in (72.2 mm) |
CSA; UL |
|||||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
700 V |
50 A |
Tab/Blade |
135 J |
200 kA |
Rated Breaking Capacity at 700 VDC: 50000 A |
Box |
0.813 in (20.65 mm) |
0.813 x 2.75 in (20.65 x 69.85 mm) |
2.75 in (69.85 mm) |
CE; CSA; UL |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
700 V |
500 A |
Tab/Blade |
150 J |
200 kA |
Rated Breaking Capacity at 700 VDC: 100000 A |
2 in (50.8 mm) |
2 x 2.843 in (50.8 x 72.2 mm) |
2.843 in (72.2 mm) |
CSA; UL |
Fast |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
700 V |
500 A |
Tab/Blade |
160 J |
200 kA |
Rated Breaking Capacity at 700 VDC: 100000 A |
2 in (50.8 mm) |
2 x 2.843 in (50.8 x 72.2 mm) |
2.843 in (72.2 mm) |
CSA; UL |
Fast |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
40 A |
Tab/Blade |
69 J |
200 kA |
Box |
2.126 in (54 mm) |
0.827 in (21 mm) |
2.126 x 0.827 x 1.575 in (54 x 21 x 40 mm) |
1.575 in (40 mm) |
CE; CSA; DIN 43653; IEC; UL |
|||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
700 V |
400 V |
90 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 400 VDC: 100000 A |
1.063 in (27 mm) |
Indicator |
1.142 x 2.638 in (29 x 67 mm) |
4.606 in (117 mm) |
Time Delay |
|||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
700 V |
400 V |
90 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 400 VDC: 100000 A |
Indicator |
2.795 in (71 mm) |
2.795 in (71 mm) |
UL |
Time Delay |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
700 V |
800 A |
Tab/Blade |
78 kJ |
50 kA |
Box |
2 in (50.8 mm) |
2 x 2.844 in (50.8 x 72.24 mm) |
2.76 in (70.104 mm) |
CE; CSA; UL |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
160 A |
Tab/Blade |
1.1 kJ |
200 kA |
Box |
1.969 in (50 mm) |
1.772 in (45 mm) |
Indicator |
1.969 x 1.772 x 1.772 in (50 x 45 x 45 mm) |
1.772 in (45 mm) |
CE; DIN 43653; IEC; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
700 V |
40 A |
End Cap |
84 J |
200 kA |
Rated Breaking Capacity at 700 VDC: 50000 A |
0.563 in (14.3 mm) |
Indicator |
0.563 x 2.008 in (14.3 x 51 mm) |
2.008 in (51 mm) |
CE; IEC; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
315 A |
Tab/Blade |
6.2 kJ |
200 kA |
Box |
2.087 in (53 mm) |
2.087 in (53 mm) |
Indicator |
2.087 x 2.087 x 1.969 in (53 x 53 x 50 mm) |
1.969 in (50 mm) |
CE; IEC; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
500 V |
80 A |
End Cap |
600 J |
200 kA |
Rated Breaking Capacity at 500 VDC: 50000 A |
Box |
0.874 in (22.2 mm) |
0.874 x 2.283 in (22.2 x 58 mm) |
2.283 in (58 mm) |
IEC; UL |
||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
700 V |
500 V |
20 A |
End Cap |
39 J |
160 kA |
Bulk |
0.406 in (10.3 mm) |
GR |
0.394 x 1.496 in (10 x 38 mm) |
1.496 in (38 mm) |
CCC, CE, CSA, IEC, UL |
Fast |
|||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
500 V |
63 A |
End Cap |
280 J |
200 kA |
Rated Breaking Capacity at 500 VDC: 50000 A |
0.874 in (22.2 mm) |
Indicator |
0.874 x 2.283 in (22.2 x 58 mm) |
2.283 in (58 mm) |
CE; IEC; UL |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
10 A |
Tab/Blade |
3.8 J |
200 kA |
Box |
2.126 in (54 mm) |
0.827 in (21 mm) |
2.126 x 0.827 x 1.575 in (54 x 21 x 40 mm) |
1.575 in (40 mm) |
CE; CSA; DIN 43653; IEC; UL |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
630 A |
Tab/Blade |
52 kJ |
200 kA |
Box |
2.087 in (53 mm) |
2.087 in (53 mm) |
Indicator |
2.087 x 2.087 x 1.969 in (53 x 53 x 50 mm) |
1.969 in (50 mm) |
CE; IEC; UL |
||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
700 V |
400 V |
30 A |
End Cap |
200 kA |
Rated Breaking Capacity at 400 VDC: 100000 A |
0.827 in (21 mm) |
Indicator |
0.827 x 2.244 in (21 x 57 mm) |
2.244 in (57 mm) |
Time Delay |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
700 V |
20 A |
End Cap |
26 J |
200 kA |
Rated Breaking Capacity at 700 VDC: 50000 A |
26 |
Box |
0.563 in (14.3 mm) |
0.563 x 2 in (14.3 x 50.8 mm) |
2 in (50.8 mm) |
CSA; IEC; UL |
|||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
80 A |
Tab/Blade |
380 J |
200 kA |
Box |
2.126 in (54 mm) |
0.827 in (21 mm) |
2.126 x 0.827 x 1.575 in (54 x 21 x 40 mm) |
1.575 in (40 mm) |
CE; CSA; DIN 43653; IEC; UL |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
400 A |
Tab/Blade |
13.5 kJ |
200 kA |
Box |
2.087 in (53 mm) |
2.087 in (53 mm) |
Indicator |
2.087 x 2.087 x 1.969 in (53 x 53 x 50 mm) |
1.969 in (50 mm) |
CE; IEC; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
200 A |
Tab/Blade |
1.65 kJ |
200 kA |
Box |
2.087 in (53 mm) |
2.087 in (53 mm) |
Indicator |
2.087 x 2.087 x 1.969 in (53 x 53 x 50 mm) |
1.969 in (50 mm) |
CE; IEC; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
250 A |
Tab/Blade |
3.1 kJ |
200 kA |
Box |
2.087 in (53 mm) |
2.087 in (53 mm) |
Indicator |
2.087 x 2.087 x 1.969 in (53 x 53 x 50 mm) |
1.969 in (50 mm) |
CE; IEC; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
350 A |
Tab/Blade |
8.5 kJ |
200 kA |
Box |
2.087 in (53 mm) |
2.087 in (53 mm) |
Indicator |
2.087 x 2.087 x 1.969 in (53 x 53 x 50 mm) |
1.969 in (50 mm) |
CE; IEC; UL |
||||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
400 A |
Tab/Blade |
13.5 kJ |
200 kA |
Box |
2.087 in (53 mm) |
2.087 in (53 mm) |
Indicator |
2.087 x 2.087 x 1.969 in (53 x 53 x 50 mm) |
1.969 in (50 mm) |
CE; IEC; UL |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
500 A |
Tab/Blade |
25 kJ |
200 kA |
Box |
2.087 in (53 mm) |
2.087 in (53 mm) |
Indicator |
2.087 x 2.087 x 1.969 in (53 x 53 x 50 mm) |
1.969 in (50 mm) |
CE; IEC; UL |
||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
700 V |
700 V |
600 A |
Tab/Blade |
92 J |
200 kA |
Rated Breaking Capacity at 700 VDC: 100000 A;Joule Integral Nom at 700 VDC: 201 |
2 in (50.8 mm) |
2 x 2.843 in (50.8 x 72.2 mm) |
2.843 in (72.2 mm) |
CSA; UL |
A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.
Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.
In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.