700 V Fuses 896

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

A70QS600-4K

Mersen S A

Electric Fuse

Inline/Holder

700 V

700 V

600 A

Tab/Blade

92 J

200 kA

Rated Breaking Capacity at 700 VDC: 100000 A;Joule Integral Nom at 700 VDC: 201

2 in (50.8 mm)

2 x 2.843 in (50.8 x 72.2 mm)

2.843 in (72.2 mm)

CSA; UL

LA70QS600-4

Littelfuse

Electric Fuse

Inline/Holder

700 V

700 V

600 A

Tab/Blade

222 J

200 kA

Rated Breaking Capacity at 700 VDC: 100000 A

2 in (50.8 mm)

2 x 2.843 in (50.8 x 72.2 mm)

2.843 in (72.2 mm)

CSA; UL

Fast

LA70QS600-4K

Littelfuse

Electric Fuse

Inline/Holder

700 V

700 V

600 A

Tab/Blade

222 J

200 kA

Rated Breaking Capacity at 700 VDC: 100000 A

2 in (50.8 mm)

2 x 2.843 in (50.8 x 72.2 mm)

2.843 in (72.2 mm)

CSA; UL

Fast

170M1309

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

16 A

Tab/Blade

7.2 J

200 kA

Box

2.126 in (54 mm)

0.827 in (21 mm)

2.126 x 0.827 x 1.575 in (54 x 21 x 40 mm)

1.575 in (40 mm)

CE; CSA; DIN 43653; IEC; UL

170M1310

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

20 A

Tab/Blade

11.5 J

200 kA

Box

2.126 in (54 mm)

0.827 in (21 mm)

2.126 x 0.827 x 1.575 in (54 x 21 x 40 mm)

1.575 in (40 mm)

CE; CSA; DIN 43653; IEC; UL

170M1312

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

32 A

Tab/Blade

40 J

200 kA

Box

2.126 in (54 mm)

0.827 in (21 mm)

2.126 x 0.827 x 1.575 in (54 x 21 x 40 mm)

1.575 in (40 mm)

CE; CSA; DIN 43653; IEC; UL

170M1314

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

50 A

Tab/Blade

115 J

200 kA

Box

2.126 in (54 mm)

0.827 in (21 mm)

2.126 x 0.827 x 1.575 in (54 x 21 x 40 mm)

1.575 in (40 mm)

CE; CSA; DIN 43653; IEC; UL

170M1315

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

63 A

Tab/Blade

215 J

200 kA

Box

2.126 in (54 mm)

0.827 in (21 mm)

2.126 x 0.827 x 1.575 in (54 x 21 x 40 mm)

1.575 in (40 mm)

CE; CSA; DIN 43653; IEC; UL

170M1415

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

63 A

Tab/Blade

215 J

200 kA

Box

2.126 in (54 mm)

0.827 in (21 mm)

Indicator

2.126 x 0.827 x 1.575 in (54 x 21 x 40 mm)

1.575 in (40 mm)

CE; CSA; DIN 43653; IEC; UL

170M1416

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

80 A

Tab/Blade

380 J

200 kA

Box

2.126 in (54 mm)

0.827 in (21 mm)

Indicator

2.126 x 0.827 x 1.575 in (54 x 21 x 40 mm)

1.575 in (40 mm)

CE; CSA; DIN 43653; IEC; UL

170M3423

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

630 A

Tab/Blade

48.5 kJ

200 kA

Box

1.772 in (45 mm)

1.772 in (45 mm)

Indicator

1.772 x 1.772 x 1.969 in (45 x 45 x 50 mm)

1.969 in (50 mm)

CE; IEC; UL

7012540.1

Siba

Electric Fuse

Inline/Holder

700 V

500 V

1 A

End Cap

320 mJ

Nickel

50 kA

Rated Breaking Capacity at 500 VDC: 20000 A

Bulk

0.25 in (6.35 mm)

700 V

1 ms

0.25 x 1.252 in (6.35 x 31.8 mm)

1.252 in (31.8 mm)

CUL; UL

Very Fast

FWP-20A14FI

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

700 V

20 A

End Cap

26 J

200 kA

Rated Breaking Capacity at 700 VDC: 50000 A

0.563 in (14.3 mm)

Indicator

0.563 x 2.008 in (14.3 x 51 mm)

2.008 in (51 mm)

CE; IEC; UL

FWP-350A

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

700 V

350 A

Tab/Blade

23.7 kJ

50 kA

Box

2 in (50.8 mm)

2 x 2.84 in (50.8 x 72.14 mm)

2.84 in (72.136 mm)

CE; CSA; UL

FWP-500A

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

700 V

500 A

Tab/Blade

45.2 kJ

50 kA

Box

2.5 in (63.5 mm)

2.5 x 2.84 in (63.5 x 72.14 mm)

2.84 in (72.136 mm)

CE; CSA; UL

170M2615

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

125 A

Tab/Blade

1 kJ

200 kA

Box

2.126 in (54 mm)

1.181 in (30 mm)

Indicator

2.126 x 1.181 x 2.008 in (54 x 30 x 51 mm)

2.008 in (51 mm)

CE; CSA; DIN 43653; IEC; UL

170M4467

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

700 A

Tab/Blade

69.5 kJ

200 kA

Box

2.087 in (53 mm)

2.087 in (53 mm)

Indicator

2.087 x 2.087 x 1.969 in (53 x 53 x 50 mm)

1.969 in (50 mm)

CE; IEC; UL

AJT25

Mersen S A

Electric Fuse

Inline/Holder

700 V

400 V

25 A

End Cap

200 kA

Rated Breaking Capacity at 400 VDC: 100000 A

0.827 in (21 mm)

Indicator

0.827 x 2.244 in (21 x 57 mm)

2.244 in (57 mm)

Time Delay

AJT80

Mersen S A

Electric Fuse

Inline/Holder

700 V

400 V

80 A

Tab/Blade

200 kA

Rated Breaking Capacity at 400 VDC: 100000 A

1.063 in (27 mm)

Indicator

1.142 x 2.638 in (29 x 67 mm)

4.606 in (117 mm)

Time Delay

FWP-100A22F

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

500 V

100 A

End Cap

1.1 kJ

200 kA

Rated Breaking Capacity at 500 VDC: 50000 A

Box

0.874 in (22.2 mm)

0.874 x 2.283 in (22.2 x 58 mm)

2.283 in (58 mm)

IEC; UL

170M1322

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

315 A

Tab/Blade

12 kJ

200 kA

Box

2.126 in (54 mm)

0.827 in (21 mm)

2.126 x 0.827 x 1.575 in (54 x 21 x 40 mm)

1.575 in (40 mm)

CE; CSA; DIN 43653; IEC; UL

170M2612

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

63 A

Tab/Blade

170 J

200 kA

Box

2.126 in (54 mm)

1.181 in (30 mm)

Indicator

2.126 x 1.181 x 2.008 in (54 x 30 x 51 mm)

2.008 in (51 mm)

CE; CSA; DIN 43653; IEC; UL

PSR030FL0200Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

200 A

Threaded

3.012 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

1.969 in (50 mm)

1.693 in (43 mm)

Indicator

3.067 in (77.9 mm)

CCC; CUL; UL

125 °C (257 °F)

Fast

170M2613

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

80 A

Tab/Blade

310 J

200 kA

Box

2.126 in (54 mm)

1.181 in (30 mm)

Indicator

2.126 x 1.181 x 2.008 in (54 x 30 x 51 mm)

2.008 in (51 mm)

CE; CSA; DIN 43653; IEC; UL

170M3619

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

700 V

400 A

Tab/Blade

15 kJ

200 kA

Rated Breaking Capacity at 700 VDC: 200000 A

Box

1.969 in (50 mm)

1.772 in (45 mm)

1.969 x 1.772 x 1.772 in (50 x 45 x 45 mm)

1.772 in (45 mm)

CE; IEC; UL

170M4410

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

315 A

Tab/Blade

6.2 kJ

200 kA

Box

2.087 in (53 mm)

2.087 in (53 mm)

Indicator

2.087 x 2.087 x 1.969 in (53 x 53 x 50 mm)

1.969 in (50 mm)

CE; IEC; UL

170M4417

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

700 A

Tab/Blade

69.5 kJ

200 kA

Box

2.087 in (53 mm)

2.087 in (53 mm)

Indicator

2.087 x 2.087 x 1.969 in (53 x 53 x 50 mm)

1.969 in (50 mm)

CE; IEC; UL

170M4612

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

700 V

400 A

Tab/Blade

13.5 kJ

200 kA

Rated Breaking Capacity at 700 VDC: 200000 A

Box

2.087 in (53 mm)

1.969 in (50 mm)

2.087 x 1.969 x 2.087 in (53 x 50 x 53 mm)

2.087 in (53 mm)

CE; IEC; UL

FWP-1000A

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

700 V

1 kA

Tab/Blade

120 kJ

50 kA

Box

3.5 in (88.9 mm)

3.5 x 3.844 in (88.9 x 97.64 mm)

3.844 in (97.6376 mm)

CE; UL

FWP-10A14F

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

700 V

10 A

End Cap

3.6 J

200 kA

Rated Breaking Capacity at 700 VDC: 50000 A

Box

0.563 in (14.3 mm)

0.563 x 2 in (14.3 x 50.8 mm)

2 in (50.8 mm)

CSA; IEC; UL

170M4409

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

250 A

Tab/Blade

3.1 kJ

200 kA

Box

2.087 in (53 mm)

2.087 in (53 mm)

Indicator

2.087 x 2.087 x 1.969 in (53 x 53 x 50 mm)

1.969 in (50 mm)

CE; IEC; UL

7012540.0,5

Siba

Electric Fuse

Inline/Holder

700 V

500 V

500 mA

End Cap

120 mJ

Nickel

50 kA

Rated Breaking Capacity at 500 VDC: 20000 A

Bulk

0.25 in (6.35 mm)

6 ms

0.25 x 1.252 in (6.35 x 31.8 mm)

1.252 in (31.8 mm)

CUL; UL

Very Fast

A70Q50-4

Mersen S A

Electric Fuse

Inline/Holder

700 V

650 V

50 A

Tab/Blade

100 kA

Rated Breaking Capacity at 650 VDC: 100000 A

1.22 in (31 mm)

1.22 x 3.689 in (31 x 93.7 mm)

3.689 in (93.7 mm)

UL

Fast

AJT100EI

Mersen S A

Electric Fuse

Inline/Holder

700 V

400 V

100 A

Tab/Blade

200 kA

Rated Breaking Capacity at 400 VDC: 100000 A

Indicator

2.795 in (71 mm)

2.795 in (71 mm)

UL

Time Delay

AJT80EI

Mersen S A

Electric Fuse

Inline/Holder

700 V

400 V

80 A

Tab/Blade

200 kA

Rated Breaking Capacity at 400 VDC: 100000 A

Indicator

2.795 in (71 mm)

2.795 in (71 mm)

UL

Time Delay

FWP-100A22FI

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

500 V

100 A

End Cap

1.1 kJ

200 kA

Rated Breaking Capacity at 500 VDC: 50000 A

0.874 in (22.2 mm)

Indicator

0.874 x 2.283 in (22.2 x 58 mm)

2.283 in (58 mm)

CE; IEC; UL

FWP-200A

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

700 V

200 A

Tab/Blade

5.5 kJ

50 kA

Box

1.5 in (38.1 mm)

1.5 x 2.84 in (38.1 x 72.14 mm)

2.84 in (72.136 mm)

CE; CSA; UL

FWP-63A22FA

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

500 V

63 A

End Cap

280 J

200 kA

Rated Breaking Capacity at 500 VDC: 50000 A

0.874 in (22.2 mm)

0.874 x 2.283 in (22.2 x 58 mm)

2.283 in (58 mm)

CE; IEC; UL

PSR030US0125Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

125 A

Tab/Blade

707 J

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

1.878 in (47.7 mm)

1.693 in (43 mm)

Indicator

3.067 in (77.9 mm)

CUL; UL

125 °C (257 °F)

Fast

170M5264

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

800 A

Tab/Blade

86 kJ

200 kA

Box

1.969 in (50 mm)

2.402 in (61 mm)

Indicator

1.969 x 2.402 x 2.402 in (50 x 61 x 61 mm)

2.402 in (61 mm)

CE; DIN 43653; IEC; UL

2028220.50

Siba

Electric Fuse

Inline/Holder

700 V

50 A

Tab/Blade

140 J

200 kA

Bulk

2.165 in (55 mm)

0.807 in (20.5 mm)

700 V

Indicator

2.756 in (70 mm)

IEC, UL, VDE

Very Fast

FBP-35

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

700 V

35 A

Tab/Blade

200 kA

0.811 in (20.6 mm)

0.811 x 2.094 in (20.6 x 53.2 mm)

2.094 in (53.2 mm)

UL

FWP-35B

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

700 V

35 A

Tab/Blade

34 J

200 kA

Rated Breaking Capacity at 700 VDC: 50000 A

Box

0.813 in (20.65 mm)

0.813 x 2.75 in (20.65 x 69.85 mm)

2.75 in (69.85 mm)

CE; CSA; UL

170M2621

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

400 A

Tab/Blade

18 kJ

200 kA

Box

2.126 in (54 mm)

1.181 in (30 mm)

Indicator

2.126 x 1.181 x 2.008 in (54 x 30 x 51 mm)

2.008 in (51 mm)

CE; CSA; DIN 43653; IEC; UL

170M6661

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

700 V

700 A

Tab/Blade

44.5 kJ

200 kA

Rated Breaking Capacity at 700 VDC: 200000 A

Box

2.992 in (76 mm)

2.008 in (51 mm)

Indicator

2.992 x 2.008 x 2.992 in (76 x 51 x 76 mm)

2.992 in (76 mm)

CE; IEC; UL

170M1420

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

200 A

Tab/Blade

4.2 kJ

200 kA

Box

2.126 in (54 mm)

0.827 in (21 mm)

Indicator

2.126 x 0.827 x 1.575 in (54 x 21 x 40 mm)

1.575 in (40 mm)

CE; CSA; DIN 43653; IEC; UL

170M2616

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

160 A

Tab/Blade

1.9 kJ

200 kA

Box

2.126 in (54 mm)

1.181 in (30 mm)

Indicator

2.126 x 1.181 x 2.008 in (54 x 30 x 51 mm)

2.008 in (51 mm)

CE; CSA; DIN 43653; IEC; UL

170M3416

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

250 A

Tab/Blade

4.2 kJ

200 kA

Box

1.772 in (45 mm)

1.772 in (45 mm)

Indicator

1.772 x 1.772 x 1.969 in (45 x 45 x 50 mm)

1.969 in (50 mm)

CE; IEC; UL

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.