Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Nominal Joule Integral | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Pre Arcing Rating (A2/s) | Packing Method | Body Length/Diameter | Body Width | Fuse Class | JESD-609 Code | Rated Voltage | Resistance | Minimum Pre Arcing Time | Fuse Size | Built-in Features | Dimensions | Body Height | Reference Standard | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
125 A |
Tab/Blade |
300 kA |
Rated Breaking Capacity at 300 VDC: 100000 A |
1.63 in (41.4 mm) |
J |
600 V |
1.63 x 3 in (41.4 x 76.2 mm) |
3 in (76.2 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
125 A |
Tab/Blade |
300 kA |
Rated Breaking Capacity at 300 VDC: 100000 A |
Box |
1.63 in (41.4 mm) |
J |
600 V |
Indicator |
1.63 x 3 in (41.4 x 76.2 mm) |
3 in (76.2 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
600 V |
500 V |
125 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 500 VDC: 100000 A |
1.614 in (41 mm) |
Indicator |
1.614 x 2.992 in (41 x 76 mm) |
5.748 in (146 mm) |
Time Delay |
|||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
600 V |
500 V |
125 A |
Tab/Blade |
200 kA |
1.614 in (41 mm) |
5.748 in (146 mm) |
CSA; IEC; UL |
Time Delay |
|||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
240 V |
150 V |
125 A |
Tab/Blade |
600 J |
200 kA |
Rated Breaking Capacity at 150 VDC: 200000 A |
Box |
0.697 in (17.7 mm) |
0.697 x 1.031 in (17.7 x 26.2 mm) |
1.031 in (26.2 mm) |
CE; IEC; UL |
||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
600 V |
500 V |
125 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 500 VDC: 100000 A |
Indicator |
3.22 in (81.8 mm) |
3.22 in (81.8 mm) |
UL |
Time Delay |
|||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
600 V |
500 V |
125 A |
Tab/Blade |
200 kA |
2.126 in (54 mm) |
J |
600 V |
2.126 x 7.126 in (54 x 181 mm) |
7.126 in (181 mm) |
IEC, UL |
Time Lag |
||||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
125 A |
Tab/Blade |
Silver |
300 kA |
Rated Breaking Capacity at 300 VDC: 100000 A |
1.63 in (41.4 mm) |
e4 |
1.63 x 3 in (41.4 x 76.2 mm) |
3 in (76.2 mm) |
CE; CSA; UL |
Time Delay |
||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
500 V |
125 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 500 VDC: 20000 A |
Bulk |
1.5 in (38.1 mm) |
Indicator |
3 in (76.2 mm) |
CSA; UL |
Time Delay |
|||||||||||||||||
|
Bel Fuse |
Electric Fuse |
Inline/Holder |
1 KV |
125 A |
Tab/Blade |
3.2 kJ |
-40 °C (-40 °F) |
Tin |
50 kA |
Bulk |
2.913 in (74 mm) |
0.866 in (22 mm) |
e3 |
0.984 in (25 mm) |
125 °C (257 °F) |
Fast |
||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
500 V |
125 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 500 VDC: 20000 A |
Bulk |
1.5 in (38.1 mm) |
Indicator |
1.626 x 3 in (41.3 x 76.2 mm) |
3 in (76.2 mm) |
CSA; UL |
Time Delay |
||||||||||||||||
Mersen S A |
Electric Fuse |
Inline/Holder |
5.5 KV |
125 A |
End Cap |
80 kA |
3 in (76.2 mm) |
UL |
Medium |
||||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
58 V |
125 A |
Tab/Blade |
62.5 kJ |
-40 °C (-40 °F) |
Matte Tin |
1 kA |
62500 |
0.63 in (16 mm) |
0.472 in (12 mm) |
e3 |
58 V |
0.472 x 0.307 x 0.63 in (12 x 7.8 x 16 mm) |
0.315 in (8 mm) |
UL |
125 °C (257 °F) |
||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
125 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
1.787 in (45.4 mm) |
Indicator |
9.626 in (244.5 mm) |
CSA; UL |
Time Delay |
|||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
1 KV |
125 A |
Tab/Blade |
100 kA |
80 ms |
Bulk |
1.22 in (31 mm) |
2.874 in (73 mm) |
IATF 16949; UL |
|||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
58 V |
125 A |
Wraparound |
51 kJ |
-40 °C (-40 °F) |
Matte Tin |
2 kA |
51000 |
0.925 in (23.5 mm) |
0.787 in (20 mm) |
e3 |
58 V |
0.925 x 0.787 x 0.453 in (23.5 x 20 x 11.5 mm) |
0.453 in (11.5 mm) |
UL |
125 °C (257 °F) |
||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
1 KV |
125 A |
Tab/Blade |
100 kA |
80 ms |
Bulk |
1.22 in (31 mm) |
2.874 in (73 mm) |
IATF 16949; UL |
|||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
500 V |
125 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 500 VDC: 20000 A |
Bulk |
1.5 in (38.1 mm) |
3 in (76.2 mm) |
CSA; UL |
Time Delay |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
125 A |
Tab/Blade |
1 kJ |
200 kA |
Box |
2.126 in (54 mm) |
1.181 in (30 mm) |
Indicator |
2.126 x 1.181 x 2.008 in (54 x 30 x 51 mm) |
2.008 in (51 mm) |
CE; CSA; DIN 43653; IEC; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
1.3 KV |
1.3 KV |
125 A |
Tab/Blade |
1.45 kJ |
100 kA |
Rated Breaking Capacity at 1300 VDC: 100000 A |
Box |
3.15 in (80 mm) |
1.772 in (45 mm) |
Indicator |
3.15 x 1.772 x 1.772 in (80 x 45 x 45 mm) |
1.772 in (45 mm) |
CE; DIN 43653; IEC; UL |
||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
415 V |
125 A |
Tab/Blade |
29.5 kJ |
Box |
1.22 in (31 mm) |
1.22 x 1.85 in (31 x 47 mm) |
1.85 in (47 mm) |
BS 88; IEC |
|||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
1 KV |
125 A |
Tab/Blade |
23.529 kJ |
20 kA |
10 m |
Rated Breaking Capacity at 1000 VDC: 20000 A |
Bulk |
1.5 in (38.1 mm) |
Midget |
3.012 in (76.5 mm) |
CE; IEC; UL |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
125 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
1.079 in (27.4 mm) |
600 V |
1.657 in (42.1 mm) |
CE; CSA; UL |
Fast |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
500 V |
125 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 500 VDC: 20000 A |
Bulk |
1.5 in (38.1 mm) |
3 in (76.2 mm) |
CSA; UL |
Time Delay |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
125 A |
Tab/Blade |
707 J |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
1.878 in (47.7 mm) |
1.693 in (43 mm) |
Indicator |
3.067 in (77.9 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
125 A |
Tab/Blade |
57.8 kJ |
-40 °C (-40 °F) |
2 kA |
100 ms |
Bulk |
1.15 in (29.2 mm) |
0.748 in (19 mm) |
32 V |
Mega |
0.39 in (9.9 mm) |
125 °C (257 °F) |
Time Delay |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
125 A |
Tab/Blade |
57.8 kJ |
-40 °C (-40 °F) |
2 kA |
100 ms |
Bulk |
1.15 in (29.2 mm) |
0.748 in (19 mm) |
32 V |
Mega |
1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm) |
0.39 in (9.9 mm) |
125 °C (257 °F) |
Time Delay |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
125 A |
Tab/Blade |
57.8 kJ |
-40 °C (-40 °F) |
2 kA |
100 ms |
1.15 in (29.2 mm) |
0.748 in (19 mm) |
32 V |
Mega |
1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm) |
0.39 in (9.9 mm) |
ISO; UL |
125 °C (257 °F) |
Time Delay |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
125 A |
Tab/Blade |
57.8 kJ |
-40 °C (-40 °F) |
Silver |
2 kA |
Bulk |
1.15 in (29.21 mm) |
0.75 in (19.05 mm) |
e4 |
1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm) |
0.42 in (10.67 mm) |
125 °C (257 °F) |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
125 A |
Tab/Blade |
57.8 kJ |
-40 °C (-40 °F) |
2 kA |
Bulk |
1.15 in (29.21 mm) |
0.75 in (19.05 mm) |
1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm) |
0.42 in (10.67 mm) |
UL |
125 °C (257 °F) |
Time Delay |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
125 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
1.079 in (27.4 mm) |
600 V |
1.657 in (42.1 mm) |
CE; CSA; UL |
Fast |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
125 A |
Tab/Blade |
1.503 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 500 VDC: 50000 A |
Bulk |
1.218 in (30.94 mm) |
10 ms |
2.125 in (53.98 mm) |
CE; CUL; UL |
125 °C (257 °F) |
Very Fast |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
48 V |
125 A |
Tab/Blade |
-40 °C (-40 °F) |
750 A |
200 ms |
Bulk |
1.26 in (32 mm) |
0.866 in (22 mm) |
48 V |
1.26 x 0.866 x 0.413 in (32 x 22 x 10.5 mm) |
0.413 in (10.5 mm) |
CUL; UL |
125 °C (257 °F) |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
700 V |
125 A |
Tab/Blade |
2.208 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 700 VDC: 50000 A |
Box |
1.218 in (30.94 mm) |
2.875 in (73.03 mm) |
CUL; UL |
125 °C (257 °F) |
Very Fast |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1 KV |
125 A |
Tab/Blade |
4.5 kJ |
-40 °C (-40 °F) |
30 kA |
Bulk |
1 in (25.4 mm) |
2.875 in (73.03 mm) |
125 °C (257 °F) |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
70 V |
125 A |
Tab/Blade |
38 kJ |
-40 °C (-40 °F) |
Tin |
2.5 kA |
100 ms |
Bulk |
1.15 in (29.2 mm) |
0.748 in (19 mm) |
e3 |
70 V |
Mega |
0.39 in (9.9 mm) |
ISO |
125 °C (257 °F) |
|||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
125 A |
Tab/Blade |
62.5 kJ |
-40 °C (-40 °F) |
Tin |
2 kA |
100 ms |
62500 |
0.63 in (16 mm) |
0.472 in (12 mm) |
e3 |
32 V |
0.63 x 0.472 x 0.315 in (16 x 12 x 8 mm) |
0.315 in (8 mm) |
CUL; ISO; UL |
125 °C (257 °F) |
|||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
690 V |
125 A |
Tab/Blade |
1.18 kJ |
200 kA |
1.378 in (35 mm) |
0.807 in (20.5 mm) |
1.378 x 0.807 x 1.957 in (35 x 20.5 x 49.7 mm) |
1.957 in (49.7 mm) |
CE; CSA; IEC; UL |
||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
1 KV |
125 A |
Tab/Blade |
1.5 kJ |
150 kA |
2.126 in (54 mm) |
1.181 in (30 mm) |
Indicator |
2.126 x 1.181 x 2.008 in (54 x 30 x 51 mm) |
2.008 in (51 mm) |
CE; DIN 43653; IEC; UL |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
32 V |
125 A |
Wraparound |
45 kJ |
-40 °C (-40 °F) |
2 kA |
100 ms |
1.181 in (30 mm) |
1.047 in (26.6 mm) |
Mega |
0.63 in (16 mm) |
125 °C (257 °F) |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
70 V |
125 A |
Tab/Blade |
51.3 kJ |
-40 °C (-40 °F) |
2.5 kA |
70 ms |
0.63 in (16 mm) |
0.496 in (12.6 mm) |
0.323 in (8.2 mm) |
UL |
125 °C (257 °F) |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
400 V |
400 V |
125 A |
End Cap |
120 kA |
C22 |
0.866 in (22 mm) |
0.866 x 2.283 in (22 x 58 mm) |
2.283 in (58 mm) |
IEC |
||||||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
415 V |
125 A |
Tab/Blade |
57 kJ |
80 kA |
Box |
1.024 in (26 mm) |
1.024 x 2.283 in (26 x 58 mm) |
2.283 in (58 mm) |
IEC |
|||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.5 KV |
125 A |
Threaded |
7.091 kJ |
-55 °C (-67 °F) |
250 kA |
Bulk |
4.988 in (126.7 mm) |
2.028 in (51.5 mm) |
Indicator |
2.028 in (51.5 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
1.5 KV |
125 A |
Tab/Blade |
1.95 kJ |
30 kA |
Bulk |
5.039 in (128 mm) |
2.047 in (52 mm) |
Indicator |
2.047 in (52 mm) |
IEC; UL |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
125 A |
Tab/Blade |
25 kJ |
120 kA |
Box |
1.929 in (49 mm) |
1.181 in (30 mm) |
NH00 |
Indicator |
1.89 in (48 mm) |
CE; DIN; IEC; VDE |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
1.3 KV |
1.3 KV |
125 A |
Tab/Blade |
1.45 kJ |
100 kA |
Rated Breaking Capacity at 1300 VDC: 100000 A |
Box |
3.15 in (80 mm) |
1.772 in (45 mm) |
Indicator |
3.15 x 1.772 x 1.772 in (80 x 45 x 45 mm) |
1.772 in (45 mm) |
CE; DIN 43653; IEC; UL |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
80 V |
125 A |
Wraparound |
52 kJ |
-40 °C (-40 °F) |
2 kA |
100 ms |
1.232 in (31.3 mm) |
0.984 in (25 mm) |
0.63 in (16 mm) |
125 °C (257 °F) |
A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.
Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.
In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.