Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Nominal Joule Integral | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Pre Arcing Rating (A2/s) | Packing Method | Body Length/Diameter | Body Width | Fuse Class | JESD-609 Code | Rated Voltage | Resistance | Minimum Pre Arcing Time | Fuse Size | Built-in Features | Dimensions | Body Height | Reference Standard | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
125 A |
Tab/Blade |
57.8 kJ |
-40 °C (-40 °F) |
2 kA |
100 ms |
Bulk |
1.15 in (29.2 mm) |
0.748 in (19 mm) |
32 V |
Mega |
0.39 in (9.9 mm) |
125 °C (257 °F) |
Time Delay |
|||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
5.5 KV |
125 A |
End Cap |
80 kA |
Hermitically Sealed Part Number |
6.38 in (162.05 mm) |
6.38 x 15.875 in (162.05 x 403.23 mm) |
15.875 in (403.23 mm) |
Medium |
||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
125 A |
Threaded |
707 J |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
1.969 in (50 mm) |
1.693 in (43 mm) |
Indicator |
3.067 in (77.9 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
170 V |
125 A |
Tab/Blade |
Silver |
100 kA |
0.563 in (14.3 mm) |
e4 |
0.563 x 0.88 in (14.3 x 22.35 mm) |
0.88 in (22.35 mm) |
CE; UL |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.3 KV |
1 KV |
125 A |
Tab/Blade |
1.352 kJ |
-55 °C (-67 °F) |
100 kA |
Rated Breaking Capacity at 1000 VDC: 150000 A |
Bulk |
2.823 in (71.7 mm) |
1.693 in (43 mm) |
Indicator |
3.067 in (77.9 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
125 A |
Tab/Blade |
57 kJ |
-40 °C (-40 °F) |
2 kA |
100 ms |
57000 |
Bulk |
1.15 in (29.2 mm) |
0.748 in (19 mm) |
Mega |
1.15 x 0.75 x 0.39 in (29.2 x 19.05 x 9.9 mm) |
0.39 in (9.9 mm) |
125 °C (257 °F) |
Time Delay |
||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
125 A |
Tab/Blade |
33.856 kJ |
-40 °C (-40 °F) |
20 kA |
0.787 in (20 mm) |
50 ms |
1.654 in (42 mm) |
125 °C (257 °F) |
|||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
2.75 KV |
125 A |
End Cap |
80 kA |
Hermitically Sealed Part Number |
3 in (76.2 mm) |
3 x 10.875 in (76.2 x 276.23 mm) |
10.875 in (276.23 mm) |
Medium |
||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
170 V |
125 A |
Tab/Blade |
Silver |
100 kA |
0.563 in (14.3 mm) |
e4 |
0.563 x 0.88 in (14.3 x 22.35 mm) |
0.88 in (22.35 mm) |
CE; UL |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
80 V |
125 A |
Tab/Blade |
2.7 kA |
3.181 in (80.8 mm) |
80 V |
3.18 in (80.77 mm) |
CUL; UL |
Very Fast |
|||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
125 A |
Tab/Blade |
73.2 kJ |
-40 °C (-40 °F) |
2 kA |
Bulk |
0.63 in (16 mm) |
0.472 in (12 mm) |
0.63 x 0.472 x 0.327 in (16 x 12 x 8.3 mm) |
0.327 in (8.3 mm) |
125 °C (257 °F) |
Time Delay |
|||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
5.5 KV |
125 A |
End Cap |
80 kA |
10 m |
3 in (76.2 mm) |
Striker |
3 x 15.875 in (76.2 x 403.23 mm) |
15.874 in (403.2 mm) |
Medium |
|||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
125 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
1.843 in (46.8 mm) |
Indicator |
1.843 x 9.626 in (46.8 x 244.5 mm) |
9.626 in (244.5 mm) |
CSA; QPL; UL |
Time Delay |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
125 A |
Tab/Blade |
57.8 kJ |
Copper |
2 kA |
Rated Breaking Capacity at 32 VDC: 2000 A |
1.15 in (29.21 mm) |
0.75 in (19.05 mm) |
1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm) |
0.42 in (10.67 mm) |
Slow |
||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
125 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
1.843 in (46.8 mm) |
1.843 x 9.626 in (46.8 x 244.5 mm) |
9.626 in (244.5 mm) |
CSA; UL |
Time Delay |
||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
150 V |
100 V |
125 A |
Tab/Blade |
100 kA |
L13S |
Rated Breaking Capacity at 100 VDC: 20000 A |
1 in (25.4 mm) |
1 x 1.157 in (25.4 x 29.4 mm) |
1.157 in (29.4 mm) |
CSA; UL |
Fast |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
48 V |
48 V |
125 A |
Tab/Blade |
2.5 kA |
1.535 in (39 mm) |
1.195 in (30.35 mm) |
48 V |
1.535 x 0.683 in (39 x 17.35 mm) |
0.683 in (17.35 mm) |
UL |
Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
125 V |
48 V |
125 A |
Tab/Blade |
2.5 kA |
3.181 in (80.8 mm) |
2.43 in (61.72 mm) |
UL |
Very Fast |
|||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
15.5 KV |
125 A |
End Cap |
60 kA |
LCN |
6.38 in (162.05 mm) |
6.38 x 23.875 in (162.05 x 606.43 mm) |
23.875 in (606.43 mm) |
Medium |
||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
32 V |
125 A |
Tab/Blade |
2.5 kA |
3.181 in (80.8 mm) |
UL |
Fast |
||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
2.75 KV |
125 A |
End Cap |
80 kA |
10 m |
6.382 in (162.1 mm) |
Striker |
3 x 10.875 in (76.2 x 276.23 mm) |
10.874 in (276.2 mm) |
Medium |
|||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
125 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 600 VDC: 20000 A |
Bulk |
1.787 in (45.4 mm) |
9.626 in (244.5 mm) |
CSA; UL |
Time Delay |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
125 A |
Tab/Blade |
118.1 kJ |
-40 °C (-40 °F) |
2 kA |
100 ms |
1.142 in (29 mm) |
0.642 in (16.3 mm) |
32 V |
0.366 in (9.3 mm) |
UL |
125 °C (257 °F) |
Slow |
||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
8.25 KV |
125 A |
End Cap |
80 kA |
Hermitically Sealed Part Number |
6.38 in (162.05 mm) |
6.38 x 17.87 in (162.05 x 453.89 mm) |
17.87 in (453.89 mm) |
Medium |
||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
8.25 KV |
125 A |
End Cap |
80 kA |
150E-1C-8.25 |
3 in (76.2 mm) |
3 x 15.874 in (76.2 x 403.2 mm) |
15.874 in (403.2 mm) |
|||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
70 V |
125 A |
Tab/Blade |
43 kJ |
-40 °C (-40 °F) |
2.5 kA |
100 ms |
1.15 in (29.21 mm) |
0.75 in (19.05 mm) |
0.39 in (9.9 mm) |
125 °C (257 °F) |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
125 A |
Tab/Blade |
78 kJ |
-40 °C (-40 °F) |
Tin |
2 kA |
100 ms |
1.15 in (29.2 mm) |
0.75 in (19.05 mm) |
e3 |
32 V |
Mega |
0.381 in (9.69 mm) |
125 °C (257 °F) |
Time Delay |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
70 V |
125 A |
Tab/Blade |
38 kJ |
-40 °C (-40 °F) |
Tin |
2.5 kA |
100 ms |
Bulk |
1.15 in (29.2 mm) |
0.748 in (19 mm) |
e3 |
70 V |
Mega |
0.39 in (9.9 mm) |
ISO |
125 °C (257 °F) |
|||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
70 V |
125 A |
Tab/Blade |
51.3 kJ |
-40 °C (-40 °F) |
2.5 kA |
70 ms |
0.63 in (16 mm) |
0.496 in (12.6 mm) |
0.323 in (8.2 mm) |
UL |
125 °C (257 °F) |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
70 V |
125 A |
Tab/Blade |
43 kJ |
-40 °C (-40 °F) |
2.5 kA |
100 ms |
1.15 in (29.21 mm) |
0.75 in (19.05 mm) |
0.39 in (9.9 mm) |
125 °C (257 °F) |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
125 A |
Tab/Blade |
5.6 J |
200 kA |
Rated Breaking Capacity at 500 VDC: 100000 A |
1.22 in (31 mm) |
500 V |
1.22 x 2.13 in (31 x 54.1 mm) |
2.13 in (54.1 mm) |
CSA; UL |
Fast |
||||||||||||||||
Littelfuse |
Electric Fuse |
125 A |
Tab/Blade |
-40 °C (-40 °F) |
1 kA |
0.63 in (16 mm) |
0.472 in (12 mm) |
32 V |
0.63 x 0.472 x 0.327 in (16 x 12 x 8.3 mm) |
0.327 in (8.3 mm) |
UL |
125 °C (257 °F) |
Time Lag |
||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
125 A |
Tab/Blade |
-55 °C (-67 °F) |
200 kA |
1.5 in (38.1 mm) |
1.5 x 2.843 in (38.1 x 72.2 mm) |
2.843 in (72.2 mm) |
CSA; UL |
125 °C (257 °F) |
Very Fast |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
58 V |
125 A |
Tab/Blade |
118.1 kJ |
-40 °C (-40 °F) |
1 kA |
100 ms |
1.142 in (29 mm) |
58 V |
1.142 x 0.74 x 0.366 in (29 x 18.8 x 9.3 mm) |
0.366 in (9.3 mm) |
UL |
125 °C (257 °F) |
Slow |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
125 A |
Tab/Blade |
73.2 kJ |
-40 °C (-40 °F) |
2 kA |
Bulk |
0.63 in (16 mm) |
0.472 in (12 mm) |
0.327 in (8.3 mm) |
125 °C (257 °F) |
Time Delay |
||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
2.75 KV |
125 A |
End Cap |
80 kA |
10 m |
6.382 in (162.1 mm) |
Striker |
6.38 x 10.875 in (162.05 x 276.23 mm) |
10.874 in (276.2 mm) |
Medium |
|||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
15.5 KV |
125 A |
End Cap |
80 kA |
10 m |
6.382 in (162.1 mm) |
Striker |
6.38 x 18.875 in (162.05 x 479.43 mm) |
18.875 in (479.43 mm) |
Medium |
|||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
5.5 KV |
125 A |
End Cap |
80 kA |
LCY |
Hermitically Sealed Part Number |
3 in (76.2 mm) |
3 x 15.875 in (76.2 x 403.23 mm) |
15.875 in (403.23 mm) |
Medium |
|||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
32 V |
125 A |
Pin Wire |
87.5 kJ |
-40 °C (-40 °F) |
Tin |
2 kA |
100 ms |
e3 |
1.386 x 0.64 x 0.703 in (35.2 x 16.25 x 17.85 mm) |
125 °C (257 °F) |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
125 A |
Tab/Blade |
73.2 kJ |
-40 °C (-40 °F) |
2 kA |
Bulk |
0.63 in (16 mm) |
0.472 in (12 mm) |
0.63 x 0.472 x 0.327 in (16 x 12 x 8.3 mm) |
0.327 in (8.3 mm) |
125 °C (257 °F) |
Time Delay |
|||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
8.25 KV |
125 A |
Tab/Blade |
80 kA |
7.94 in (201.68 mm) |
7.94 x 16.131 in (201.68 x 409.72 mm) |
16.131 in (409.72 mm) |
Medium |
|||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
170 V |
125 A |
Tab/Blade |
Rated Breaking Capacity at 170 VDC: 100000 A |
1.594 in (40.5 mm) |
1.594 x 4.173 in (40.5 x 106 mm) |
4.173 in (106 mm) |
UL |
Fast |
||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
15.5 KV |
125 A |
Tab/Blade |
60 kA |
7.94 in (201.68 mm) |
7.94 x 21.13 in (201.68 x 536.7 mm) |
21.13 in (536.7 mm) |
Medium |
|||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
15.5 KV |
125 A |
End Cap |
60 kA |
Hermitically Sealed Part Number |
6.38 in (162.05 mm) |
6.38 x 23.875 in (162.05 x 606.43 mm) |
23.875 in (606.43 mm) |
Medium |
||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
5.5 KV |
125 A |
End Cap |
80 kA |
Hermitically Sealed Part Number |
3 in (76.2 mm) |
3 x 17.875 in (76.2 x 454.03 mm) |
17.875 in (454.03 mm) |
Medium |
||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
32 V |
125 A |
Tab/Blade |
2.5 kA |
3.181 in (80.8 mm) |
2.43 in (61.72 mm) |
UL |
Fast |
|||||||||||||||||||
Littelfuse |
Electric Fuse |
Panel Mount |
32 V |
125 A |
Screw |
-40 °C (-40 °F) |
125 °C (257 °F) |
||||||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
70 V |
125 A |
Tab/Blade |
38 kJ |
-40 °C (-40 °F) |
2.5 kA |
100 ms |
1.15 in (29.2 mm) |
0.748 in (19 mm) |
Mega |
0.39 in (9.9 mm) |
125 °C (257 °F) |
Time Delay |
A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.
Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.
In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.