20 A Fuses 679

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

FWP-20A14F

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

700 V

20 A

End Cap

26 J

200 kA

Rated Breaking Capacity at 700 VDC: 50000 A

26

Box

0.563 in (14.3 mm)

0.563 x 2 in (14.3 x 50.8 mm)

2 in (50.8 mm)

CSA; IEC; UL

KLK020

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

20 A

End Cap

100 kA

Rated Breaking Capacity at 500 VDC: 50000 A

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Fast

KLM-20

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

600 V

20 A

End Cap

100 kA

Bulk

0.406 in (10.3 mm)

CC

600 V

Midget

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE, CSA, UL

Fast

ATMR20

Mersen S A

Electric Fuse

Inline/Holder

600 V

600 V

20 A

End Cap

200 kA

Rated Breaking Capacity = 27A-10kA

Bulk

0.409 in (10.4 mm)

0.409 x 1.5 in (10.4 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Fast

C14G20I

Eaton Corporation

Electric Fuse

Inline/Holder

690 V

690 V

20 A

End Cap

80 kA

C14

0.551 in (14 mm)

Indicator

0.551 x 2.008 in (14 x 51 mm)

2.008 in (51 mm)

IEC

C14G20S

Eaton Corporation

Electric Fuse

Inline/Holder

690 V

690 V

20 A

End Cap

80 kA

C14

0.551 in (14 mm)

0.551 x 2.008 in (14 x 51 mm)

2.008 in (51 mm)

IEC

0SLC020.T

Littelfuse

Electric Fuse

20 A

End Cap

100 kA

0.406 in (10.3 mm)

G

600 V

0.406 x 1.406 in (10.3 x 35.7 mm)

1.406 in (35.7 mm)

CSA, UL

Medium

170M1310

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

20 A

Tab/Blade

11.5 J

200 kA

Box

2.126 in (54 mm)

0.827 in (21 mm)

2.126 x 0.827 x 1.575 in (54 x 21 x 40 mm)

1.575 in (40 mm)

CE; CSA; DIN 43653; IEC; UL

FWP-20A14FI

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

700 V

20 A

End Cap

26 J

200 kA

Rated Breaking Capacity at 700 VDC: 50000 A

0.563 in (14.3 mm)

Indicator

0.563 x 2.008 in (14.3 x 51 mm)

2.008 in (51 mm)

CE; IEC; UL

G5A01216C

Therm-o-disc

Thermal Fuse

Through Hole Mount

250 V

20 A

Pin Wire

Tape And Reel, 14 inch

0.157 in (4 mm)

250 V

0.579 in (14.7 mm)

XEV10-20-1P

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

20 A

Tab/Blade

761 J

-40 °C (-40 °F)

20 kA

0.406 in (10.3 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

125 °C (257 °F)

0312020.MXP

Littelfuse

Electric Fuse

Inline/Holder

32 V

20 A

End Cap

1.414 kJ

-55 °C (-67 °F)

Tin

300 A

10 s

Bulk

0.25 in (6.35 mm)

e3

3AG

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA; UL

125 °C (257 °F)

Fast

FLNR020.T

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

20 A

End Cap

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

Bulk

0.563 in (14.3 mm)

2 in (50.8 mm)

CSA; UL

Time Delay

0FLM020.T

Littelfuse

Electric Fuse

Inline/Holder

250 V

20 A

End Cap

10 kA

Pre Arcing Time: Open within 12 s at 200% Rated Current

0.406 in (10.31 mm)

250 V

Midget

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; QPL; UL

Slow

0FLM020T

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

20 A

End Cap

10 kA

12 s

Pre Arcing Time: Open within 12 s at 200% Rated Current

Bulk

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE; CSA; QPL; UL

Time Delay

15CLE-20E-D

Eaton Corporation

Electric Fuse

Inline/Holder

15.5 KV

15.5 KV

20 A

End Cap

63 kA

2.992 in (76 mm)

23.898 in (607 mm)

ANSI

17037-G

Mersen S A

Electric Fuse

Inline/Holder

690 V

20 A

End Cap

Silver

80 kA

Box

0.563 in (14.3 mm)

e4

690 V

0.563 x 2.008 in (14.3 x 51 mm)

2.008 in (51 mm)

IEC; NFC; UNE

20C14X51GI

Altech

Electric Fuse

Inline/Holder

690 V

20 A

End Cap

80 kA

Bulk

0.551 in (14 mm)

0.551 x 2.008 in (14 x 51 mm)

2.008 in (51 mm)

CE; IEC

Slow

BK-AGC-20-R

Eaton Corporation

Electric Fuse

Inline/Holder

32 V

20 A

End Cap

2.44 kJ

-55 °C (-67 °F)

Nickel

1 kA

Pre Arcing Time: Open within 120 s at 200% Rated Current

1.438

Box

0.25 in (6.35 mm)

32 V

0.248 x 1.26 in (6.3 x 32 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA; UL

125 °C (257 °F)

Fast

BK/AGC-20-R

Cooper Industries

Electric Fuse

Inline/Holder

32 V

20 A

End Cap

1.438 J

Nickel

1 kA

AGC

Box

0.25 in (6.35 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA; UL

Fast

BK1/ABC-20-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 V

20 A

End Cap

550.8 J

Nickel

400 A

2 m

Pre Arcing Time: Open within 120 s at 200% Rated Current

Box

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA; UL

Fast

BK8/ABC-20-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 V

20 A

End Cap

550.8 J

Nickel

400 A

2 m

Pre Arcing Time: Open within 120 s at 200% Rated Current

Box

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA; UL

Fast

C14M20I

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

20 A

End Cap

120 kA

C14

0.551 in (14 mm)

Indicator

0.551 x 2.008 in (14 x 51 mm)

2.008 in (51 mm)

IEC

CY14X51G20

Littelfuse

Electric Fuse

Inline/Holder

690 V

20 A

End Cap

80 kA

0.551 in (14 mm)

690 V

0.551 x 2.008 in (14 x 51 mm)

0.551 x 2.008 in (14 x 51 mm)

2.008 in (51 mm)

IEC

Fast

CY14X51M20

Littelfuse

Electric Fuse

Inline/Holder

690 V

20 A

End Cap

80 kA

0.551 in (14 mm)

690 V

0.551 x 2.008 in (14 x 51 mm)

0.551 x 2.008 in (14 x 51 mm)

2.008 in (51 mm)

IEC

Time Lag

0034.3130.PT

Schurter Ag

Electric Fuse

Through Hole Mount

250 V

20 A

Pin Wire

3.057 kJ

-55 °C (-67 °F)

Tin

200 A

Bulk

0.213 in (5.4 mm)

e3

20 ms

0.213 x 0.886 in (5.4 x 22.5 mm)

0.213 x 0.886 in (5.4 x 22.5 mm)

0.886 in (22.5 mm)

125 °C (257 °F)

Time Lag

0287020.PXS

Littelfuse

Electric Fuse

Inline/Holder

32 V

20 A

Tab/Blade

520 J

-40 °C (-40 °F)

Tin

1 kA

80 ms

0.752 in (19.1 mm)

0.201 in (5.1 mm)

e3

0.74 in (18.8 mm)

CSA; UL

125 °C (257 °F)

0505020.MXP

Littelfuse

Electric Fuse

Inline/Holder

500 V

500 V

20 A

End Cap

140 J

-55 °C (-67 °F)

Nickel

30 kA

10 s

Rated Breaking Capacity at 500 VDC: 20000 A

140

Bulk

0.25 in (6.35 mm)

500 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

125 °C (257 °F)

Fast

0997020WXN

Littelfuse

Electric Fuse

Inline/Holder

58 V

20 A

Tab/Blade

380 J

-40 °C (-40 °F)

Silver

1 kA

Rated Breaking Capacity at 58 VDC: 1000 A

Bulk

0.429 in (10.9 mm)

0.14 in (3.55 mm)

e4

0.429 x 0.14 x 0.346 in (10.9 x 3.55 x 8.8 mm)

0.346 in (8.8 mm)

125 °C (257 °F)

0997020.WXN

Littelfuse

Electric Fuse

Inline/Holder

58 V

20 A

Tab/Blade

380 J

-40 °C (-40 °F)

1 kA

30 ms

0.429 in (10.9 mm)

0.15 in (3.8 mm)

58 V

Mini

0.346 in (8.8 mm)

ISO; UL

125 °C (257 °F)

0ADEC9200-BE

Bel Fuse

Electric Fuse

Inline/Holder

500 V

500 V

20 A

End Cap

120 J

-55 °C (-67 °F)

Silver

30 kA

10 s

Interrupting Current Max(DC): 20000 A, Pre Arcing Time: Open within 10 s at 300% Rated Current

Bulk

0.252 in (6.4 mm)

e4

500 V

0.236 x 1.26 in (6 x 32 mm)

1.252 in (31.8 mm)

CUL; UL

105 °C (221 °F)

Fast

0HEV020.ZXBD

Littelfuse

Electric Fuse

Inline/Holder

450 V

20 A

Tab/Blade

268 J

-40 °C (-40 °F)

10 kA

50 ms

0.406 in (10.3 mm)

450 V

1.531 in (38.9 mm)

CSA; UL

125 °C (257 °F)

166.7000.520.2

Littelfuse

Electric Fuse

20 A

Tab/Blade

Matte Tin

1 kA

475

0.748 in (19 mm)

0.197 in (5 mm)

Supplemental

e3

80 V

ATO

0.748 x 0.197 x 0.52 in (19 x 5 x 13.2 mm)

0.52 in (13.2 mm)

CSA; UL

Time Lag

166.7000.5202

Littelfuse

Electric Fuse

Inline/Holder

80 V

20 A

Tab/Blade

475 J

Tin

Rated Breaking Capacity at 80 VDC: 1000A

0.748 in (19 mm)

0.197 in (5 mm)

e3

0.748 x 0.197 x 0.52 in (19 x 5 x 13.2 mm)

0.52 in (13.2 mm)

UL

997020

Littelfuse

Electric Fuse

Inline/Holder

58 V

20 A

Tab/Blade

-40 °C (-40 °F)

1 kA

Rated Breaking Capacity at 58 VDC: 1000 A

0.43 in (10.92 mm)

0.15 in (3.81 mm)

0.43 x 0.15 x 0.344 in (10.92 x 3.81 x 8.75 mm)

0.344 in (8.75 mm)

125 °C (257 °F)

Fast

BK/MDA-20-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 V

20 A

End Cap

483.45 J

Nickel

1.5 kA

2 m

Rated Breaking Capacity at 125 VDC: 10000 A

Box

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA, UL

Time Delay

FNQ-20

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

20 A

End Cap

10 kA

Box

0.406 in (10.3 mm)

500 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

SF-2410F2000T-2

Bourns

Electric Fuse

Surface Mount

65 V

65 V

20 A

Wraparound

140.8 J

-55 °C (-67 °F)

Gold

50 A

Tape And Reel, 7 inch

0.24 in (6.1 mm)

0.102 in (2.6 mm)

e4

60 s

2410

0.24 x 0.102 x 0.102 in (6.1 x 2.6 x 2.6 mm)

0.102 in (2.6 mm)

UL

125 °C (257 °F)

Fast

0034.5630.22

Schurter Ag

Electric Fuse

Inline/Holder

250 V

20 A

End Cap

3.057 kJ

-55 °C (-67 °F)

Gold

200 A

Tape And Reel, 13 inch

0.205 in (5.2 mm)

e4

20 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

125 °C (257 °F)

Time Lag

0090.0020

Schurter Ag

Electric Fuse

Inline/Holder

1 KV

20 A

End Cap

1.313 kJ

-50 °C (-58 °F)

Nickel

20 kA

Bulk

0.406 in (10.3 mm)

240 s

0.406 x 1.496 in (10.3 x 38 mm)

0.406 x 1.496 in (10.3 x 38 mm)

1.496 in (38 mm)

CSA; UL

125 °C (257 °F)

0326020.HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 V

20 A

End Cap

575 J

-55 °C (-67 °F)

Nickel

400 A

4 h

575

Bulk

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; KC; PSE; UL

125 °C (257 °F)

Time Lag

0501020.WRS

Littelfuse

Electric Fuse

Surface Mount

32 V

20 A

Wraparound

54.76 J

-55 °C (-67 °F)

Tin Over Nickel

150 A

4 h

54.76

Tape And Reel

0.126 in (3.2 mm)

0.064 in (1.63 mm)

e3

32 V

2 mΩ

1206

0.126 x 0.064 x 0.033 in (3.2 x 1.63 x 0.835 mm)

0.033 in (0.835 mm)

CSA; UL

150 °C (302 °F)

Fast

3403.0287.23

Schurter Ag

Electric Fuse

Surface Mount

125 V

72 V

20 A

Wraparound

445 J

-55 °C (-67 °F)

Nickel/Tin

100 A

Tape And Reel, 13 inch

0.606 in (15.4 mm)

0.211 in (5.35 mm)

e2

5 ms

0.209 x 0.63 in (5.3 x 16 mm)

0.211 in (5.35 mm)

CUL, UL

125 °C (257 °F)

Time Lag

BBS-20

Eaton Corporation

Electric Fuse

20 A

End Cap

0.41 in (10.41 mm)

48 V

0.41 x 1.38 in (10.41 x 35.05 mm)

1.38 in (35.05 mm)

CE

Fast

CC12H20A-TR

Eaton Corporation

Electric Fuse

Surface Mount

32 V

20 A

Wraparound

80 J

-55 °C (-67 °F)

100 A

5 s

Pre Arcing Time: Open within 5 s at 350% Rated Current

50

Tape And Reel, 7 inch

0.126 in (3.2 mm)

0.063 in (1.6 mm)

32 V

1206

0.126 x 0.063 x 0.024 in (3.2 x 1.6 x 0.6 mm)

0.026 in (0.65 mm)

AEC-Q200; CUL; UL

125 °C (257 °F)

GSA20

Mersen S A

Electric Fuse

Inline/Holder

250 V

20 A

End Cap

400 A

0.25 in (6.35 mm)

125 V

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA; UL

Time Delay

SC-20

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

170 V

20 A

End Cap

100 kA

Rated Breaking Capacity at 170 VDC: 10000 A

Box

0.406 in (10.3 mm)

G

600 V

0.406 x 1.41 in (10.3 x 35.81 mm)

1.41 in (35.81 mm)

CSA; UL

Fast And Time Delay

0451020.MRL

Littelfuse

Electric Fuse

Surface Mount

65 V

65 V

20 A

Wraparound

154 J

-55 °C (-67 °F)

Gold

100 A

20 s

Rated Breaking Capacity at 65 VDC: 150 A

Tape And Reel

0.24 in (6.1 mm)

0.106 in (2.69 mm)

e4

65 V

Nano

0.106 in (2.69 mm)

CE; CUL; TUV; UL

125 °C (257 °F)

Very Fast

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.