Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

10EV020.ZXISO

Littelfuse

Electric Fuse

Inline/Holder

500 V

20 A

Tab/Blade

-40 °C (-40 °F)

20 kA

50 ms

Bulk

0.406 in (10.3 mm)

1.531 in (38.9 mm)

125 °C (257 °F)

Time Delay

10EV020.ZXBDP

Littelfuse

Electric Fuse

Inline/Holder

500 V

20 A

Tab/Blade

-40 °C (-40 °F)

20 kA

50 ms

Bulk

0.406 in (10.3 mm)

1.531 in (38.9 mm)

125 °C (257 °F)

Time Delay

10EV020.ZXPY

Littelfuse

Electric Fuse

Inline/Holder

500 V

20 A

Tab/Blade

-40 °C (-40 °F)

20 kA

50 ms

Bulk

0.406 in (10.3 mm)

1.531 in (38.9 mm)

125 °C (257 °F)

Time Delay

10EV020.ZXC

Littelfuse

Electric Fuse

Inline/Holder

500 V

20 A

End Cap

-40 °C (-40 °F)

20 kA

50 ms

Bulk

0.406 in (10.3 mm)

1.531 in (38.9 mm)

125 °C (257 °F)

Time Delay

0ATO020.ZXPRO

Littelfuse

Electric Fuse

Inline/Holder

32 V

20 A

Tab/Blade

520 J

-40 °C (-40 °F)

1 kA

100 ms

Bulk

0.752 in (19.1 mm)

0.201 in (5.1 mm)

0.484 in (12.3 mm)

CSA; UL

125 °C (257 °F)

ATO20BP

Littelfuse

Electric Fuse

Inline/Holder

32 V

20 A

Tab/Blade

520 J

-40 °C (-40 °F)

1 kA

100 ms

Bulk

0.752 in (19.1 mm)

0.201 in (5.1 mm)

0.484 in (12.3 mm)

CSA; UL

125 °C (257 °F)

10EV020.ZXPCBL

Littelfuse

Electric Fuse

Inline/Holder

500 V

20 A

Tab/Blade

-40 °C (-40 °F)

20 kA

50 ms

Bulk

0.406 in (10.3 mm)

1.531 in (38.9 mm)

125 °C (257 °F)

Time Delay

0ATO020.VP

Littelfuse

Electric Fuse

Inline/Holder

32 V

20 A

Tab/Blade

520 J

-40 °C (-40 °F)

1 kA

100 ms

Bulk

0.752 in (19.1 mm)

0.201 in (5.1 mm)

0.484 in (12.3 mm)

CSA; UL

125 °C (257 °F)

10EV020.ZXPCB

Littelfuse

Electric Fuse

Inline/Holder

500 V

20 A

Tab/Blade

-40 °C (-40 °F)

20 kA

50 ms

Bulk

0.406 in (10.3 mm)

1.531 in (38.9 mm)

125 °C (257 °F)

Time Delay

30-1020

Littelfuse

Electric Fuse

Inline/Holder

32 V

20 A

Tab/Blade

-40 °C (-40 °F)

1 kA

40 ms

Bulk

1.15 in (29.21 mm)

0.348 in (8.85 mm)

0.85 in (21.59 mm)

125 °C (257 °F)

Time Delay

0MAX020.XPGLO

Littelfuse

Electric Fuse

Inline/Holder

32 V

20 A

Tab/Blade

-40 °C (-40 °F)

1 kA

40 ms

Bulk

1.15 in (29.21 mm)

0.348 in (8.85 mm)

0.85 in (21.59 mm)

125 °C (257 °F)

Time Delay

0JTD020.TXID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

20 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.811 in (20.6 mm)

Indicator

2.252 in (57.2 mm)

CSA; UL

Time Delay

0JLS020.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

20 A

End Cap

200 kA

Bulk

0.811 in (20.6 mm)

2.252 in (57.2 mm)

CE; CSA; QPL; UL

Fast

0JTD020.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

20 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.811 in (20.6 mm)

2.252 in (57.2 mm)

CSA; UL

Time Delay

0BLF020.T

Littelfuse

Electric Fuse

Inline/Holder

125 V

20 A

End Cap

10 kA

2 m

Bulk

0.406 in (10.31 mm)

5AG

1.5 in (38.1 mm)

CE; CSA; UL

Fast

0317020.MR

Littelfuse

Electric Fuse

Surface Mount

18 V

20 A

Wraparound

728 J

-40 °C (-40 °F)

1 kA

20 ms

Tape And Reel

0.319 in (8.1 mm)

0.244 in (6.2 mm)

0.187 in (4.75 mm)

105 °C (221 °F)

FLA020

Littelfuse

Electric Fuse

Inline/Holder

125 V

20 A

End Cap

10 kA

12 s

Bulk

0.406 in (10.31 mm)

5AG

Indicator

1.5 in (38.1 mm)

UL

Time Delay

0FLA020.V

Littelfuse

Electric Fuse

Inline/Holder

125 V

20 A

End Cap

10 kA

12 s

Bulk

0.406 in (10.31 mm)

5AG

Indicator

1.5 in (38.1 mm)

UL

Time Delay

0293820.U

Littelfuse

Electric Fuse

Inline/Holder

32 V

20 A

Tab/Blade

-40 °C (-40 °F)

40 ms

0.669 in (17 mm)

0.52 in (13.2 mm)

1.059 in (26.9 mm)

125 °C (257 °F)

0504020.MX52LEP

Littelfuse

Electric Fuse

Through Hole Mount

500 V

420 V

20 A

Pin Wire

760 J

-60 °C (-76 °F)

200 A

Bulk

0.275 in (6.985 mm)

120 s

3AG

1.288 in (32.72 mm)

CE; CU; CUL

125 °C (257 °F)

0293820.MXJ

Littelfuse

Electric Fuse

Inline/Holder

32 V

20 A

Tab/Blade

-40 °C (-40 °F)

40 ms

0.669 in (17 mm)

0.52 in (13.2 mm)

1.059 in (26.9 mm)

125 °C (257 °F)

0293820.H

Littelfuse

Electric Fuse

Inline/Holder

32 V

20 A

Tab/Blade

-40 °C (-40 °F)

40 ms

0.669 in (17 mm)

0.52 in (13.2 mm)

1.059 in (26.9 mm)

125 °C (257 °F)

0297020.WXNV-CN

Littelfuse

Electric Fuse

Inline/Holder

32 V

20 A

Tab/Blade

442 J

-40 °C (-40 °F)

1 kA

30 ms

0.429 in (10.9 mm)

0.15 in (3.8 mm)

Mini

0.346 in (8.8 mm)

UL

125 °C (257 °F)

0506020.MXEP

Littelfuse

Electric Fuse

Through Hole Mount

600 V

20 A

Pin Wire

105 J

-55 °C (-67 °F)

10 kA

2 m

Bulk

0.275 in (6.99 mm)

3AB

1.288 in (32.72 mm)

CUL; UL

125 °C (257 °F)

Fast

0828020.ZXISOP

Littelfuse

Electric Fuse

Inline/Holder

1 KV

20 A

Tab/Blade

536 J

-55 °C (-67 °F)

10 kA

1 h

Tray

0.482 in (12.25 mm)

1.543 in (39.2 mm)

CUL; UL

125 °C (257 °F)

0MIN020.ZXPRO

Littelfuse

Electric Fuse

Inline/Holder

32 V

20 A

Tab/Blade

380 J

-40 °C (-40 °F)

1 kA

30 ms

Bulk

0.429 in (10.9 mm)

0.15 in (3.8 mm)

0.346 in (8.8 mm)

UL

125 °C (257 °F)

0MAX020.X

Littelfuse

Electric Fuse

Inline/Holder

32 V

20 A

Tab/Blade

1.1 kJ

-40 °C (-40 °F)

1 kA

40 ms

Box

1.15 in (29.2 mm)

0.346 in (8.8 mm)

0.85 in (21.6 mm)

UL

125 °C (257 °F)

Slow

LMIN020.V

Littelfuse

Electric Fuse

Inline/Holder

58 V

20 A

Tab/Blade

420 J

-40 °C (-40 °F)

1 kA

30 ms

Box

0.429 in (10.9 mm)

0.15 in (3.8 mm)

Mini

0.299 in (7.6 mm)

125 °C (257 °F)

0RLN020.T

Littelfuse

Electric Fuse

Inline/Holder

250 V

20 A

End Cap

10 kA

0.563 in (14.3 mm)

2 in (50.8 mm)

CE; CSA; UL

Fast

0PAL020.XPA

Littelfuse

Electric Fuse

Inline/Holder

20 A

Tab/Blade

Blister

LLNRK020.V

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

20 A

End Cap

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

0.563 in (14.3 mm)

2 in (50.8 mm)

CE; CSA; UL; QPL

Time Delay

LLSRK020.TXID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

20 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

Indicator

5 in (127 mm)

CE; CSA; UL; QPL

Time Delay

L60S020.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

20 A

End Cap

-55 °C (-67 °F)

200 kA

Box

0.811 in (20.6 mm)

5 in (127 mm)

CSA; UL

125 °C (257 °F)

Very Fast

KLNR0020

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

20 A

End Cap

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

0.563 in (14.3 mm)

2 in (50.8 mm)

CE; CSA; UL

Fast

KLSR0020

Littelfuse

Electric Fuse

Inline/Holder

600 V

250 V

20 A

End Cap

200 kA

Rated Breaking Capacity at 250 VDC: 20000 A

0.811 in (20.6 mm)

5 in (127 mm)

CE; CSA; UL

Fast

0PAL020.XP

Littelfuse

Electric Fuse

Inline/Holder

20 A

Tab/Blade

Blister

0RLS020.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

20 A

End Cap

10 kA

0.811 in (20.6 mm)

5 in (127 mm)

CE; CSA; UL

Fast

0KLC020.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

20 A

Tab/Blade

-55 °C (-67 °F)

200 kA

Box

0.563 in (14.3 mm)

1.874 in (47.6 mm)

CSA; UL

125 °C (257 °F)

Very Fast

0PAL020.X

Littelfuse

Electric Fuse

Inline/Holder

20 A

Tab/Blade

Bulk

0456020.ERHF

Littelfuse

Electric Fuse

Surface Mount

125 V

20 A

Wraparound

18 J

-55 °C (-67 °F)

100 A

1 m

Pre Arcing Time: Open within 60 s at 200% Rated Current

Tape And Reel

0.397 in (10.08 mm)

0.12 in (3.05 mm)

Nano

0.12 in (3.05 mm)

CSA; CUL; PSE; TUV; UL

125 °C (257 °F)

Very Fast

L15S020.T

Littelfuse

Electric Fuse

Inline/Holder

150 V

150 V

20 A

End Cap

-55 °C (-67 °F)

100 kA

Rated Breaking Capacity at 150 VDC: 20000 A

Box

0.406 in (10.3 mm)

1.5 in (38.1 mm)

CSA; UL

125 °C (257 °F)

Very Fast

0TLS020.TXMB

Littelfuse

Electric Fuse

Inline/Holder

170 V

20 A

Tab/Blade

100 kA

Bulk

0.563 in (14.3 mm)

0.877 in (22.28 mm)

CUL; IEC; TUV; UL

0TLS020.SLSA

Littelfuse

Electric Fuse

Inline/Holder

170 V

20 A

Tab/Blade

100 kA

Bulk

0.563 in (14.3 mm)

0.877 in (22.28 mm)

CUL; IEC; TUV; UL

0506020MXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

20 A

End Cap

105 J

-55 °C (-67 °F)

Nickel

10 kA

105

Bulk

0.25 in (6.35 mm)

600 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; UL

125 °C (257 °F)

Fast

DZ16F20

Littelfuse

Electric Fuse

Inline/Holder

500 V

500 V

20 A

End Cap

80 kA

DZ

Rated Breaking Capacity at 500 VDC: 80000 A

0.52 in (13.2 mm)

Indicator

0.52 x 1.969 in (13.2 x 50 mm)

1.969 in (50 mm)

DIN; IEC; VDE

Fast

0453020.MR

Littelfuse

Electric Fuse

Surface Mount

65 V

65 V

20 A

Wraparound

154 J

-55 °C (-67 °F)

Silver

100 A

20 s

Rated Breaking Capacity at 65 VDC: 150 A

Tape And Reel

0.24 in (6.1 mm)

0.106 in (2.69 mm)

e4

65 V

Nano

0.106 in (2.69 mm)

CE; CUL; TUV; UL

125 °C (257 °F)

Very Fast

0327020.YX2T

Littelfuse

Electric Fuse

Inline/Holder

32 V

20 A

Tab/Blade

400 J

-40 °C (-40 °F)

Tin

1 kA

20 ms

Bulk

0.358 in (9.1 mm)

0.15 in (3.8 mm)

e3

32 V

Micro

0.602 in (15.3 mm)

125 °C (257 °F)

0481020.HXL

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

20 A

End Cap

1.024 kJ

-55 °C (-67 °F)

300 A

5 m

0.839 in (21.3 mm)

0.228 in (5.8 mm)

125 V

Alarm; Indicator

0.772 in (19.6 mm)

CSA; UL

125 °C (257 °F)

Fast

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.