35 A Fuses 213

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

FWX-35A

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

250 V

35 A

Tab/Blade

50 J

200 kA

Rated Breaking Capacity at 250 VDC: 20000 A

Box

0.81 in (20.57 mm)

0.81 x 1.59 in (20.57 x 40.39 mm)

1.59 in (40.39 mm)

CE; CSA; UL

35NHG000B

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

35 A

Tab/Blade

2.4 kJ

120 kA

Box

1.929 in (49 mm)

0.827 in (21 mm)

NH000

Indicator

1.614 in (41 mm)

CE; DIN; IEC; VDE

FRN-R-35

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 V

35 A

End Cap

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

Box

0.81 in (20.57 mm)

RK5

250 V

0.811 x 3 in (20.6 x 76.2 mm)

3 in (76.2 mm)

CE; CSA; UL

Time Delay

FRN-R-3.5

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 V

35 A

End Cap

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

Box

0.81 in (20.57 mm)

RK5

250 V

0.811 x 3 in (20.6 x 76.2 mm)

3 in (76.2 mm)

CE; CSA; UL

Time Delay

BK/ATC-35

Eaton Corporation

Electric Fuse

Inline/Holder

32 V

32 V

35 A

Tab/Blade

-40 °C (-40 °F)

Tin

1 kA

100 ms

Bulk

0.752 in (19.1 mm)

0.201 in (5.1 mm)

e3

32 V

0.752 x 0.201 x 0.483 in (19.1 x 5.1 x 12.28 mm)

0.483 in (12.28 mm)

UL

100 °C (212 °F)

Fast

LPJ-35SP

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

35 A

End Cap

300 kA

Rated Breaking Capacity at 300 VDC: 100000 A

1.063 in (27 mm)

J

600 V

1.063 x 2.374 in (27 x 60.3 mm)

2.374 in (60.3 mm)

CE; CSA; UL

Time Delay

LPJ-35SPI

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

35 A

End Cap

300 kA

Rated Breaking Capacity at 300 VDC: 100000 A

Box

1.063 in (27 mm)

J

600 V

Indicator

1.063 x 2.374 in (27 x 60.3 mm)

2.374 in (60.3 mm)

CE; CSA; UL

Time Delay

35LET

Eaton Corporation

Electric Fuse

Inline/Holder

240 V

150 V

35 A

Tab/Blade

50 J

200 kA

Rated Breaking Capacity at 150 VDC: 200000 A

Box

0.697 in (17.7 mm)

0.697 x 1.031 in (17.7 x 26.2 mm)

1.031 in (26.2 mm)

CE; IEC; UL

FRS-R-35

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

35 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Box

1.063 in (27 mm)

1.063 x 5.5 in (27 x 139.7 mm)

5.5 in (139.7 mm)

CE; CSA; UL

Time Delay

0257035.PXPV

Littelfuse

Electric Fuse

Inline/Holder

32 V

35 A

Tab/Blade

2.28 kJ

-40 °C (-40 °F)

Tin/Copper

1 kA

Bulk

0.75 in (19.05 mm)

0.2 in (5.08 mm)

e2

0.75 x 0.2 x 0.48 in (19.05 x 5.08 x 12.19 mm)

0.48 in (12.19 mm)

UL

105 °C (221 °F)

0257035PXPV

Littelfuse

Electric Fuse

Inline/Holder

32 V

35 A

Tab/Blade

2.28 kJ

-40 °C (-40 °F)

Tin

1 kA

0257

Rated Breaking Capacity at 32 VDC: 1000 A

Bulk

0.75 in (19.05 mm)

0.2 in (5.08 mm)

e3

0.75 x 0.2 x 0.48 in (19.05 x 5.08 x 12.19 mm)

0.48 in (12.19 mm)

UL

105 °C (221 °F)

35FE

Eaton Corporation

Electric Fuse

Inline/Holder

690 V

350 V

35 A

Tab/Blade

33 J

200 kA

Rated Breaking Capacity at 690 VDC: 200000 A

Box

1.89 in (48 mm)

1.89 x 0.752 in (48 x 19.1 mm)

0.752 in (19.1 mm)

BS 88; CE

0CNN035.V

Littelfuse

Electric Fuse

Inline/Holder

125 V

48 V

35 A

Tab/Blade

2.5 kA

3.181 in (80.8 mm)

48 V

3.18 in (80.77 mm)

UL

Very Fast

0TLS035.TXLS

Littelfuse

Electric Fuse

Inline/Holder

170 V

35 A

Tab/Blade

100 kA

Bulk

0.563 in (14.3 mm)

0.563 x 0.877 in (14.3 x 22.27 mm)

0.877 in (22.28 mm)

CUL; IEC; TUV; UL

35ET

Eaton Corporation

Electric Fuse

Inline/Holder

690 V

350 V

35 A

Tab/Blade

52 J

200 kA

Rated Breaking Capacity at 690 VDC: 200000 A

Box

1.89 in (48 mm)

1.89 x 0.752 in (48 x 19.1 mm)

0.752 in (19.1 mm)

BS 88; CE

NON-35

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 V

35 A

End Cap

50 kA

Rated Breaking Capacity at 125 VDC: 50000 A

Box

0.81 in (20.57 mm)

K5

250 V

0.81 x 3 in (20.57 x 76.19 mm)

3 in (76.19 mm)

CE; UL

0TLS035.TXL

Littelfuse

Electric Fuse

Inline/Holder

170 V

35 A

Tab/Blade

100 kA

Bulk

0.563 in (14.3 mm)

170 V

0.563 x 0.88 in (14.3 x 22.35 mm)

0.877 in (22.28 mm)

CUL; IEC; TUV; UL

0TLS035.TXLB

Littelfuse

Electric Fuse

Inline/Holder

170 V

35 A

Tab/Blade

100 kA

Bulk

0.563 in (14.3 mm)

170 V

0.563 x 0.877 in (14.3 x 22.27 mm)

0.877 in (22.28 mm)

CUL; IEC; TUV; UL

JJS-35

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

35 A

End Cap

200 kA

0.811 in (20.6 mm)

0.811 x 1.563 in (20.6 x 39.7 mm)

1.563 in (39.7 mm)

CE; CSA; UL

Very Fast

SC-35

Eaton Corporation

Electric Fuse

Inline/Holder

480 V

300 V

35 A

End Cap

100 kA

Rated Breaking Capacity at 300 VDC: 10000 A

Box

0.406 in (10.3 mm)

G

480 V

0.406 x 2.25 in (10.3 x 57.15 mm)

2.25 in (57.15 mm)

CSA; UL

Fast And Time Delay

FBP-35

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

700 V

35 A

Tab/Blade

200 kA

0.811 in (20.6 mm)

0.811 x 2.094 in (20.6 x 53.2 mm)

2.094 in (53.2 mm)

UL

FWP-35B

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

700 V

35 A

Tab/Blade

34 J

200 kA

Rated Breaking Capacity at 700 VDC: 50000 A

Box

0.813 in (20.65 mm)

0.813 x 2.75 in (20.65 x 69.85 mm)

2.75 in (69.85 mm)

CE; CSA; UL

FLNR035.TXID

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

35 A

End Cap

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

Indicator

3 in (76.2 mm)

CSA; UL

Time Delay

JTD035

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

35 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

1.063 in (27 mm)

2.374 in (60.3 mm)

CSA; UL

Time Delay

SF-3812F3500T-2

Bourns

Electric Fuse

Surface Mount

250 V

80 V

35 A

Wraparound

1.32 kJ

-55 °C (-67 °F)

Gold with Nickel barrier

100 A

Rated Breaking Capacity at 80 VDC: 130A

Tape And Reel, 13 inch

0.398 in (10.1 mm)

0.122 in (3.1 mm)

e4

60 s

3812

0.398 x 0.122 x 0.122 in (10.1 x 3.1 x 3.1 mm)

0.122 in (3.1 mm)

UL

125 °C (257 °F)

Fast

ANL-35

Eaton Corporation

Electric Fuse

Inline/Holder

80 V

35 A

End Cap

2.7 kA

3.189 in (81 mm)

Indicator

3.189 x 0.874 in (81 x 22.2 mm)

0.874 in (22.2 mm)

CSA; UL

Time Delay

0999035.ZXN

Littelfuse

Electric Fuse

Inline/Holder

58 V

35 A

Tab/Blade

6 kJ

-40 °C (-40 °F)

1 kA

40 ms

Bulk

1.15 in (29.2 mm)

0.35 in (8.9 mm)

1.15 x 0.335 x 0.85 in (29.21 x 8.51 x 21.6 mm)

0.85 in (21.6 mm)

SAE; UL

125 °C (257 °F)

Slow

FLNR35ID

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

35 A

End Cap

200 kA

0.811 in (20.6 mm)

Indicator

0.811 x 3 in (20.6 x 76.2 mm)

3 in (76.2 mm)

CSA; UL

Time Delay

UK35BP

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

35 A

End Cap

0.25 in (6.35 mm)

32 V

1.25 in (31.75 mm)

L50QS035.T

Littelfuse

Electric Fuse

Inline/Holder

500 V

500 V

35 A

Tab/Blade

111 J

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 500 VDC: 50000 A

Bulk

1 in (25.4 mm)

10 ms

2.125 in (53.98 mm)

CE; CUL; UL

125 °C (257 °F)

Very Fast

JLLS035.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

35 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.992 in (25.2 mm)

600 V

1.563 in (39.7 mm)

CE; CSA; UL

Fast

0899035.Z

Littelfuse

Electric Fuse

Inline/Holder

32 V

35 A

Tab/Blade

4.9 kJ

-40 °C (-40 °F)

1 kA

40 ms

Bulk

0.638 in (16.2 mm)

0.256 in (6.5 mm)

0.394 in (10 mm)

125 °C (257 °F)

0257035LXN

Littelfuse

Electric Fuse

Inline/Holder

32 V

35 A

Tab/Blade

2.28 kJ

-40 °C (-40 °F)

Tin

1 kA

0257

Rated Breaking Capacity at 32 VDC: 1000 A

Bulk

0.75 in (19.05 mm)

0.2 in (5.08 mm)

e3

0.75 x 0.2 x 0.48 in (19.05 x 5.08 x 12.19 mm)

0.48 in (12.19 mm)

UL

105 °C (221 °F)

AGC35CABP

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

35 A

End Cap

0.25 in (6.35 mm)

32 V

3AG

1.25 in (31.75 mm)

FLSR035

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

35 A

200 kA

FLSR

Rated Breaking Capacity at 300 VDC: 20000 A

1.063 in (27 mm)

5.5 in (139.7 mm)

CSA; UL

Time Delay

0299035.TXN

Littelfuse

Electric Fuse

Inline/Holder

32 V

35 A

Tab/Blade

6 kJ

-40 °C (-40 °F)

Silver

1 kA

40 ms

6032

Bulk

1.15 in (29.2 mm)

0.346 in (8.8 mm)

e4

32 V

1.15 x 0.348 x 0.85 in (29.21 x 8.85 x 21.59 mm)

0.85 in (21.6 mm)

UL

125 °C (257 °F)

Time Delay

0299035.ZXT

Littelfuse

Electric Fuse

Inline/Holder

32 V

35 A

Tab/Blade

6 kJ

-40 °C (-40 °F)

Silver

1 kA

40 ms

6032

Bulk

1.15 in (29.2 mm)

0.346 in (8.8 mm)

e4

32 V

1.15 x 0.348 x 0.85 in (29.21 x 8.85 x 21.59 mm)

0.85 in (21.6 mm)

UL

125 °C (257 °F)

Time Delay

0257035.L

Littelfuse

Electric Fuse

Inline/Holder

32 V

35 A

Tab/Blade

2.28 kJ

-40 °C (-40 °F)

Tin

1 kA

150 ms

Bulk

0.752 in (19.1 mm)

0.201 in (5.1 mm)

e3

0.74 in (18.8 mm)

UL

105 °C (221 °F)

LA100P35-4

Littelfuse

Electric Fuse

Inline/Holder

1 KV

750 V

35 A

Tab/Blade

2.2 J

100 kA

Rated Breaking Capacity at 750 VDC: 100000 A

1 in (25.4 mm)

1 x 6.811 in (25.4 x 173 mm)

6.811 in (173 mm)

UL

Very Fast

0312035.MXP

Littelfuse

Electric Fuse

Inline/Holder

32 V

35 A

End Cap

7.531 kJ

-55 °C (-67 °F)

Matte Tin

300 A

20 s

Tape And Reel

0.25 in (6.35 mm)

e3

3AG

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

125 °C (257 °F)

Fast

RLN035

Littelfuse

Electric Fuse

Inline/Holder

250 V

35 A

End Cap

10 kA

0.811 in (20.6 mm)

3 in (76.2 mm)

CE; CSA; UL

TLN035

Littelfuse

Electric Fuse

Inline/Holder

170 V

35 A

End Cap

Rated Breaking Capacity at 170 VDC: 100000 A

0.811 in (20.6 mm)

0.811 x 3 in (20.6 x 76.2 mm)

3 in (76.2 mm)

UL

Fast

TLS035V

Littelfuse

Electric Fuse

Inline/Holder

170 V

35 A

Tab/Blade

Silver

100 kA

0.563 in (14.3 mm)

e4

0.563 x 0.88 in (14.3 x 22.35 mm)

0.88 in (22.35 mm)

CE; UL

LA15QS35-1

Littelfuse

Electric Fuse

Inline/Holder

150 V

150 V

35 A

End Cap

210 mJ

100 kA

Rated Breaking Capacity at 150 VDC: 100000 A

0.811 in (20.6 mm)

0.811 x 2 in (20.6 x 50.8 mm)

2 in (50.8 mm)

UL

Very Fast

0581035

Littelfuse

Electric Fuse

Inline/Holder

48 V

48 V

35 A

Tab/Blade

2.5 kA

1.535 in (39 mm)

1.195 in (30.35 mm)

48 V

1.535 x 0.683 in (39 x 17.35 mm)

0.683 in (17.35 mm)

UL

Fast

FLNR03.5ID

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

35 A

End Cap

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

0.811 in (20.6 mm)

Indicator

0.811 x 3 in (20.6 x 76.2 mm)

3 in (76.2 mm)

CSA; QPL; UL

Time Delay

0257035.U

Littelfuse

Electric Fuse

Inline/Holder

32 V

35 A

Tab/Blade

2.28 kJ

-40 °C (-40 °F)

Silver

1 kA

150 ms

Bulk

0.752 in (19.1 mm)

0.201 in (5.1 mm)

e4

0.74 in (18.8 mm)

UL

105 °C (221 °F)

0287035.PXCN

Littelfuse

Electric Fuse

Inline/Holder

32 V

35 A

Tab/Blade

2.3 kJ

-40 °C (-40 °F)

Tin

1 kA

80 ms

0.752 in (19.1 mm)

0.201 in (5.1 mm)

e3

0.752 x 0.201 x 0.484 in (19.1 x 5.1 x 12.3 mm)

0.74 in (18.8 mm)

CSA; UL

125 °C (257 °F)

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.