Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

LGD35

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

35 A

End Cap

200 kA

LGD

Rated Breaking Capacity at 300 VDC: 20000 A

CSA; IEC; UL

Time Delay

TLS-LB035

Littelfuse

Electric Fuse

Inline/Holder

170 V

35 A

Tab/Blade

Silver

Rated Breaking Capacity at 170 VDC: 100000

0.563 in (14.3 mm)

e4

0.563 x 1.367 in (14.3 x 34.72 mm)

1.367 in (34.72 mm)

UL

0257035.LXN

Littelfuse

Electric Fuse

Inline/Holder

32 V

35 A

Tab/Blade

2.28 kJ

-40 °C (-40 °F)

Tin/Copper

1 kA

0257

Bulk

0.75 in (19.05 mm)

0.2 in (5.08 mm)

e2

0.75 x 0.2 x 0.48 in (19.05 x 5.08 x 12.19 mm)

0.48 in (12.19 mm)

UL

105 °C (221 °F)

0299035TXN

Littelfuse

Electric Fuse

Inline/Holder

32 V

35 A

Tab/Blade

6.032 kJ

-40 °C (-40 °F)

Silver

Rated Breaking Capacity at 32 VDC: 1000 A

1.15 in (29.21 mm)

0.348 in (8.85 mm)

e4

1.15 x 0.348 x 0.85 in (29.21 x 8.85 x 21.59 mm)

0.85 in (21.59 mm)

125 °C (257 °F)

299035

Littelfuse

Electric Fuse

Inline/Holder

32 V

35 A

Tab/Blade

6.032 kJ

Silver

1 kA

Rated Breaking Capacity at 32 VDC: 1000 A

1.15 in (29.21 mm)

0.348 in (8.85 mm)

e4

1.15 x 0.348 x 0.85 in (29.21 x 8.85 x 21.59 mm)

0.85 in (21.59 mm)

UL

Slow

KLB35

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 V

35 A

Tab/Blade

200 kA

KLB

Rated Breaking Capacity at 250 VDC: 20000 A

0.811 in (20.6 mm)

0.811 x 1.626 in (20.6 x 41.3 mm)

1.626 in (41.3 mm)

CSA; UL

Fast

JTD035ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

35 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

1.063 in (27 mm)

Indicator

0.811 x 2.252 in (20.6 x 57.2 mm)

2.374 in (60.3 mm)

CSA; UL

Time Delay

LA50QS35-4

Littelfuse

Electric Fuse

Inline/Holder

500 V

500 V

35 A

Tab/Blade

560 mJ

200 kA

Rated Breaking Capacity at 500 VDC: 100000 A

1 in (25.4 mm)

500 V

1 x 2.13 in (25.4 x 54.1 mm)

2.13 in (54.1 mm)

CSA; UL

Fast

0CCK035.V

Littelfuse

Electric Fuse

Inline/Holder

125 V

35 A

Tab/Blade

10 kA

0.81 in (20.57 mm)

3.74 in (94.99 mm)

Time Delay

0287035

Littelfuse

Electric Fuse

Inline/Holder

32 V

35 A

Tab/Blade

2.28 kJ

-40 °C (-40 °F)

1 kA

0.75 in (19.05 mm)

0.2 in (5.08 mm)

0.75 x 0.2 x 0.48 in (19.05 x 5.08 x 12.19 mm)

0.48 in (12.19 mm)

105 °C (221 °F)

D0Z18G35

Littelfuse

Electric Fuse

Inline/Holder

380 V

250 V

35 A

End Cap

50 kA

D0Z1

Rated Breaking Capacity at 250 VDC: 50000 A

0.591 in (15 mm)

Indicator

0.591 x 1.417 in (15 x 36 mm)

1.417 in (36 mm)

DIN; IEC; VDE

Fast

0312035MX

Littelfuse

Electric Fuse

Inline/Holder

32 V

35 A

End Cap

7.531 kJ

-55 °C (-67 °F)

Tin

300 A

312

Bulk

0.25 in (6.35 mm)

e3

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

125 °C (257 °F)

Fast

157.5701.5351

Littelfuse

Electric Fuse

Inline/Holder

48 V

35 A

Tab/Blade

-40 °C (-40 °F)

210 A

200 ms

Bulk

1.26 in (32 mm)

0.866 in (22 mm)

48 V

1.26 x 0.866 x 0.413 in (32 x 22 x 10.5 mm)

0.413 in (10.5 mm)

CUL; UL

125 °C (257 °F)

UK35CABP

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

35 A

End Cap

0.25 in (6.35 mm)

32 V

1.25 in (31.75 mm)

TLS035LB

Littelfuse

Electric Fuse

Inline/Holder

170 V

35 A

Tab/Blade

Silver

100 kA

0.563 in (14.3 mm)

e4

0.563 x 0.88 in (14.3 x 22.35 mm)

0.88 in (22.35 mm)

CE; UL

0TLS035.TXV

Littelfuse

Electric Fuse

Inline/Holder

170 V

35 A

Tab/Blade

100 kA

Bulk

0.563 in (14.3 mm)

170 V

0.563 x 0.877 in (14.3 x 22.27 mm)

0.877 in (22.28 mm)

CUL; IEC; TUV; UL

0299035.L

Littelfuse

Electric Fuse

Inline/Holder

32 V

35 A

Tab/Blade

6 kJ

-40 °C (-40 °F)

Silver

1 kA

40 ms

6032

Bulk

1.15 in (29.2 mm)

0.346 in (8.8 mm)

e4

32 V

1.15 x 0.348 x 0.85 in (29.21 x 8.85 x 21.59 mm)

0.85 in (21.6 mm)

UL

125 °C (257 °F)

Time Delay

AGC35H/311035

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

35 A

End Cap

Bulk

0.25 in (6.35 mm)

32 V

3AG

1.25 in (31.75 mm)

Normal

157.5917.5351

Littelfuse

Electric Fuse

Inline/Holder

48 V

35 A

Tab/Blade

-40 °C (-40 °F)

210 A

200 ms

Bulk

1.26 in (32 mm)

0.866 in (22 mm)

48 V

1.26 x 0.866 x 0.413 in (32 x 22 x 10.5 mm)

0.413 in (10.5 mm)

CUL; UL

125 °C (257 °F)

LLSRK035ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

35 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

1.063 in (27 mm)

Indicator

1.063 x 5.5 in (27 x 139.7 mm)

5.5 in (139.7 mm)

CSA; UL

Time Delay

0CNN035E.V

Littelfuse

Electric Fuse

Inline/Holder

80 V

35 A

Tab/Blade

2.7 kA

3.181 in (80.8 mm)

80 V

3.18 in (80.77 mm)

CUL; UL

Very Fast

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.