Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Nominal Joule Integral | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Pre Arcing Rating (A2/s) | Packing Method | Body Length/Diameter | Body Width | Fuse Class | JESD-609 Code | Rated Voltage | Resistance | Minimum Pre Arcing Time | Fuse Size | Built-in Features | Dimensions | Body Height | Reference Standard | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
350 A |
Tab/Blade |
200 kA |
Bulk |
2 in (50.8 mm) |
J |
600 V |
2 x 3.374 in (50.8 x 85.7 mm) |
3.374 in (85.7 mm) |
CE; CSA; QPL; UL |
Fast |
||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
2.75 KV |
350 A |
End Cap |
80 kA |
350E-2C-2.75 |
6.378 in (162 mm) |
6.378 x 10.874 in (162 x 276.2 mm) |
10.874 in (276.2 mm) |
|||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
350 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 125 VDC: 20000 A |
2.094 in (53.2 mm) |
Indicator |
2.094 x 8.626 in (53.2 x 219.1 mm) |
8.626 in (219.1 mm) |
CSA; QPL; UL |
Time Delay |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
70 V |
350 A |
Tab/Blade |
495 kJ |
-40 °C (-40 °F) |
2.5 kA |
100 ms |
1.15 in (29.2 mm) |
0.748 in (19 mm) |
Mega |
0.39 in (9.9 mm) |
125 °C (257 °F) |
Time Delay |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.5 KV |
350 A |
Tab/Blade |
86.623 kJ |
-55 °C (-67 °F) |
250 kA |
Bulk |
4.988 in (126.7 mm) |
2.028 in (51.5 mm) |
Indicator |
2.028 in (51.5 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
1 KV |
750 V |
350 A |
Tab/Blade |
220 J |
100 kA |
Rated Breaking Capacity at 750 VDC: 100000 A |
2 in (50.8 mm) |
Indicator |
2 x 3.469 in (50.8 x 88.1 mm) |
3.469 in (88.1 mm) |
UL |
Very Fast |
||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
350 A |
Tab/Blade |
10 kA |
2.094 in (53.2 mm) |
8.626 in (219.1 mm) |
CE; CSA; UL |
||||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
1 KV |
350 A |
Tab/Blade |
10 kA |
2.594 in (65.9 mm) |
2.594 x 7.478 in (65.9 x 189.94 mm) |
7.478 in (189.94 mm) |
UL |
Fast |
||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
8.25 KV |
350 A |
End Cap |
80 kA |
10 m |
9.752 in (247.7 mm) |
Striker |
9.75 x 15.875 in (247.65 x 403.23 mm) |
15.874 in (403.2 mm) |
Medium |
|||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
1.2 KV |
350 A |
Tab/Blade |
28 J |
100 kA |
1.575 in (40 mm) |
1.575 in (40 mm) |
Indicator |
1.575 x 1.575 x 2.854 in (40 x 40 x 72.5 mm) |
2.854 in (72.5 mm) |
UL |
Very Fast |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
5.5 KV |
350 A |
End Cap |
80 kA |
LCU |
Hermitically Sealed Part Number |
6.38 in (162.05 mm) |
6.38 x 17.875 in (162.05 x 454.03 mm) |
17.875 in (454.03 mm) |
Medium |
|||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
350 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 125 VDC: 20000 A |
Bulk |
2 in (50.8 mm) |
8.626 in (219.1 mm) |
CSA; UL |
Time Delay |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
350 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
1.594 in (40.5 mm) |
1.594 x 1.72 in (40.5 x 43.7 mm) |
1.72 in (43.7 mm) |
CSA; UL |
Fast |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
350 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
2.594 in (65.9 mm) |
Indicator |
2.594 x 11.626 in (65.9 x 295.3 mm) |
11.626 in (295.3 mm) |
CSA; UL |
Time Delay |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
5.5 KV |
350 A |
End Cap |
80 kA |
Hermitically Sealed Part Number |
6.38 in (162.05 mm) |
6.38 x 15.875 in (162.05 x 403.23 mm) |
15.875 in (403.23 mm) |
Medium |
||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
300 V |
300 V |
350 A |
Tab/Blade |
62 J |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
1.5 in (38.1 mm) |
1.5 x 1.579 in (38.1 x 40.1 mm) |
1.579 in (40.1 mm) |
UL |
Very Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.3 KV |
1 KV |
350 A |
Threaded |
18.727 kJ |
-55 °C (-67 °F) |
100 kA |
Rated Breaking Capacity at 1000 VDC: 150000 A |
Bulk |
2.953 in (75 mm) |
2.362 in (60 mm) |
Indicator |
3.736 in (94.9 mm) |
CCC; CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
5.5 KV |
350 A |
Tab/Blade |
80 kA |
7.94 in (201.68 mm) |
7.94 x 16.13 in (201.68 x 409.7 mm) |
16.13 in (409.7 mm) |
Medium |
|||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
125 V |
48 V |
350 A |
Tab/Blade |
2.5 kA |
3.181 in (80.8 mm) |
2.43 in (61.72 mm) |
UL |
Very Fast |
|||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
350 A |
Threaded |
9.523 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
2.028 in (51.5 mm) |
1.969 in (50 mm) |
Indicator |
3.402 in (86.4 mm) |
CCC; CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
170 V |
350 A |
Tab/Blade |
100 kA |
Bulk |
1.5 in (38.1 mm) |
1.5 x 1.252 in (38.1 x 31.8 mm) |
1.252 in (31.8 mm) |
CSA; UL |
||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
250 V |
350 A |
Tab/Blade |
50 kA |
Rated Breaking Capacity at 250 VDC; 50000 |
2.094 in (53.2 mm) |
2.094 x 4.878 in (53.2 x 123.9 mm) |
4.878 in (123.9 mm) |
CSA; UL |
|||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1 KV |
350 A |
Tab/Blade |
10 kA |
2.594 in (65.9 mm) |
7.478 in (189.94 mm) |
UL |
Fast |
||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
150 V |
100 V |
350 A |
Tab/Blade |
-55 °C (-67 °F) |
100 kA |
Rated Breaking Capacity at 100 VDC: 20000 A |
1 in (25.4 mm) |
1 x 1.157 in (25.4 x 29.4 mm) |
1.157 in (29.4 mm) |
CSA; UL |
125 °C (257 °F) |
Very Fast |
|||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
480 V |
350 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 480 VDC: 20000 A |
2.5 in (63.5 mm) |
2.5 x 3.752 in (63.5 x 95.3 mm) |
3.752 in (95.3 mm) |
CSA; UL |
Time Delay |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
32 V |
350 A |
Tab/Blade |
2.5 kA |
3.181 in (80.8 mm) |
2.43 in (61.72 mm) |
UL |
Fast |
|||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Panel Mount |
32 V |
350 A |
Wraparound |
583.9 kJ |
-40 °C (-40 °F) |
2 kA |
100 ms |
1.232 in (31.3 mm) |
0.984 in (25 mm) |
0.63 in (16 mm) |
125 °C (257 °F) |
Time Delay |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
70 V |
350 A |
Tab/Blade |
495 kJ |
-40 °C (-40 °F) |
2.5 kA |
100 ms |
1.15 in (29.2 mm) |
0.748 in (19 mm) |
Mega |
0.39 in (9.9 mm) |
125 °C (257 °F) |
Time Delay |
|||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
350 A |
Tab/Blade |
15.5 J |
200 kA |
1.575 in (40 mm) |
1.575 in (40 mm) |
Indicator |
1.575 x 1.575 x 1.874 in (40 x 40 x 47.6 mm) |
1.874 in (47.6 mm) |
UL |
Very Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.3 KV |
1 KV |
350 A |
Threaded |
13.586 kJ |
-55 °C (-67 °F) |
100 kA |
Rated Breaking Capacity at 1000 VDC: 150000 A |
Bulk |
2.953 in (75 mm) |
2.894 in (73.5 mm) |
Indicator |
4.268 in (108.4 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.3 KV |
1 KV |
350 A |
Threaded |
18.727 kJ |
-55 °C (-67 °F) |
100 kA |
Rated Breaking Capacity at 1000 VDC: 150000 A |
Bulk |
2.953 in (75 mm) |
2.362 in (60 mm) |
Indicator |
3.736 in (94.9 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
250 V |
350 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 250 VDC: 20000 A |
1.5 in (38.1 mm) |
1.5 x 1.594 in (38.1 x 40.5 mm) |
1.594 in (40.5 mm) |
CE; CSA; UL |
Very Fast |
||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
650 V |
350 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 650 VDC: 20000 A |
2 in (50.8 mm) |
2 x 2.843 in (50.8 x 72.2 mm) |
2.843 in (72.2 mm) |
CE; CSA; UL |
Very Fast |
||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
350 A |
Tab/Blade |
-55 °C (-67 °F) |
200 kA |
Box |
1.579 in (40.1 mm) |
2.906 in (73.8 mm) |
CSA; UL |
125 °C (257 °F) |
Very Fast |
||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
350 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
2.594 in (65.9 mm) |
Indicator |
2.594 x 11.626 in (65.9 x 295.3 mm) |
11.626 in (295.3 mm) |
CSA; QPL; UL |
Time Delay |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
48 V |
48 V |
350 A |
Tab/Blade |
2.5 kA |
1.535 in (39 mm) |
1.195 in (30.35 mm) |
1.535 x 1.195 x 0.683 in (39 x 30.35 x 17.35 mm) |
0.683 in (17.35 mm) |
UL |
Fast |
||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
8.25 KV |
350 A |
End Cap |
80 kA |
LDZ |
Hermitically Sealed Part Number |
9.75 in (247.65 mm) |
9.75 x 15.875 in (247.65 x 403.23 mm) |
15.875 in (403.23 mm) |
Medium |
|||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
32 V |
350 A |
Wraparound |
570 kJ |
-40 °C (-40 °F) |
2 kA |
100 ms |
1.181 in (30 mm) |
1.047 in (26.6 mm) |
Mega |
0.63 in (16 mm) |
125 °C (257 °F) |
||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
5.5 KV |
350 A |
End Cap |
80 kA |
350E-2C-5.5 |
16.378 in (416 mm) |
16.378 x 15.874 in (416 x 403.2 mm) |
15.874 in (403.2 mm) |
|||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
350 A |
End Cap |
15.5 J |
200 kA |
1.575 in (40 mm) |
1.575 in (40 mm) |
Indicator |
1.575 x 1.575 x 1.929 in (40 x 40 x 49 mm) |
1.929 in (49 mm) |
UL |
Very Fast |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
450 V |
350 A |
Tab/Blade |
200 kA |
KLH |
Rated Breaking Capacity at 450 VDC: 20000 A |
1.5 in (38.1 mm) |
1.5 x 2.094 in (38.1 x 53.2 mm) |
2.094 in (53.2 mm) |
CSA; UL |
Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.5 KV |
350 A |
Tab/Blade |
75 kJ |
50 kA |
Bulk |
5.165 in (131.2 mm) |
2.874 in (73 mm) |
GPV |
1.5 KV |
NH |
2.874 in (73 mm) |
UL |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
350 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
1.594 in (40.5 mm) |
600 V |
1.713 in (43.5 mm) |
CE; CSA; UL |
Fast |
||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
350 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 125 VDC: 20000 A |
2.094 in (53.2 mm) |
2.094 x 8.626 in (53.2 x 219.1 mm) |
8.626 in (219.1 mm) |
CSA; UL |
Time Delay |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
1 KV |
350 A |
Tab/Blade |
232 kJ |
200 kA |
12 m |
Rated Breaking Capacity at 1000 VDC: 20000 A |
2 in (50.8 mm) |
Midget |
2 x 3.374 in (50.8 x 85.7 mm) |
3.374 in (85.7 mm) |
CE; IEC; UL; VDE |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
350 A |
Threaded |
12.007 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
1.969 in (50 mm) |
1.693 in (43 mm) |
Indicator |
3.067 in (77.9 mm) |
CCC; CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
350 A |
Tab/Blade |
88 J |
200 kA |
Rated Breaking Capacity at 500 VDC: 100000 A |
1.5 in (38.1 mm) |
500 V |
1.5 x 2.091 in (38.1 x 53.1 mm) |
2.091 in (53.1 mm) |
CSA; UL |
Fast |
||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
1.3 KV |
350 A |
Tab/Blade |
17 J |
100 kA |
2.933 in (74.5 mm) |
2.933 in (74.5 mm) |
Indicator |
2.933 x 2.933 x 2.854 in (74.5 x 74.5 x 72.5 mm) |
2.854 in (72.5 mm) |
UL |
Very Fast |
A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.
Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.
In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.