350 A Fuses 229

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

PSR070UL0350

Littelfuse

Electric Fuse

Inline/Holder

1.3 KV

1 KV

350 A

Tab/Blade

22.963 kJ

-55 °C (-67 °F)

100 kA

Rated Breaking Capacity at 1000 VDC: 150000 A

Bulk

2.823 in (71.7 mm)

1.693 in (43 mm)

Indicator

1.929 in (49 mm)

CUL; UL

125 °C (257 °F)

Fast

PSR031UL0350

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

350 A

Tab/Blade

9.523 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.028 in (51.5 mm)

1.937 in (49.2 mm)

Indicator

2.264 in (57.5 mm)

CUL; UL

125 °C (257 °F)

Fast

07945825312

Littelfuse

Electric Fuse

Inline/Holder

1.3 KV

1 KV

350 A

Tab/Blade

23.301 kJ

-55 °C (-67 °F)

100 kA

Rated Breaking Capacity at 1000 VDC: 150000 A

Bulk

2.882 in (73.2 mm)

2.028 in (51.5 mm)

Indicator

2.264 in (57.5 mm)

CUL; UL

125 °C (257 °F)

Fast

PSR030US0350

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

350 A

Tab/Blade

12.007 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

1.878 in (47.7 mm)

1.693 in (43 mm)

Indicator

1.929 in (49 mm)

CUL; UL

125 °C (257 °F)

Fast

07945828534

Littelfuse

Electric Fuse

Inline/Holder

1.3 KV

1 KV

350 A

Tab/Blade

22.963 kJ

-55 °C (-67 °F)

100 kA

Rated Breaking Capacity at 1000 VDC: 150000 A

Bulk

2.823 in (71.7 mm)

1.693 in (43 mm)

Indicator

1.929 in (49 mm)

CUL; UL

125 °C (257 °F)

Fast

07945825264

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

350 A

Tab/Blade

9.523 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.028 in (51.5 mm)

1.937 in (49.2 mm)

Indicator

2.264 in (57.5 mm)

CUL; UL

125 °C (257 °F)

Fast

07945825213

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

350 A

Tab/Blade

9.523 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.028 in (51.5 mm)

1.937 in (49.2 mm)

Indicator

2.264 in (57.5 mm)

CUL; UL

125 °C (257 °F)

Fast

FLNR350.XXID

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

350 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

Bulk

2 in (50.8 mm)

Indicator

8.626 in (219.1 mm)

CSA; UL

Time Delay

FLNR350.X

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

350 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

Bulk

2 in (50.8 mm)

8.626 in (219.1 mm)

CSA; UL

Time Delay

FLSR350.XXID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

350 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

2.543 in (64.6 mm)

Indicator

11.626 in (295.3 mm)

CSA; UL

Time Delay

JLLN350P

Littelfuse

Electric Fuse

Inline/Holder

300 V

125 V

350 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

1.311 in (33.3 mm)

2.752 in (69.9 mm)

CE; CSA; CUL; UL

Fast

L70QS350

Littelfuse

Electric Fuse

Inline/Holder

700 V

700 V

350 A

Tab/Blade

24.778 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 700 VDC: 50000 A

2 in (50.8 mm)

2.844 in (72.24 mm)

CUL; UL

125 °C (257 °F)

Very Fast

LLNRK350.V

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

350 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

2.094 in (53.2 mm)

8.626 in (219.1 mm)

CE; CSA; UL; QPL

Time Delay

LLSRK350.TXID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

350 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

2.594 in (65.9 mm)

Indicator

11.626 in (295.3 mm)

CE; CSA; UL; QPL

Time Delay

0RLN350.T

Littelfuse

Electric Fuse

Inline/Holder

250 V

350 A

Tab/Blade

10 kA

2.094 in (53.2 mm)

8.626 in (219.1 mm)

CE; CSA; UL

0RLS350.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

350 A

Tab/Blade

10 kA

2.594 in (65.9 mm)

11.626 in (295.3 mm)

CE; CSA; UL

L15S350.T

Littelfuse

Electric Fuse

Inline/Holder

150 V

100 V

350 A

Tab/Blade

-55 °C (-67 °F)

100 kA

Rated Breaking Capacity at 100 VDC: 20000 A

Box

1 in (25.4 mm)

1.157 in (29.4 mm)

CSA; UL

125 °C (257 °F)

Very Fast

KLSR0350

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

350 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

2.594 in (65.9 mm)

11.626 in (295.3 mm)

CE; CSA; UL

Fast

KLNR0350

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

350 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

2.094 in (53.2 mm)

8.626 in (219.1 mm)

CE; CSA; UL

Fast

0KLC350.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

350 A

Tab/Blade

-55 °C (-67 °F)

200 kA

Box

2 in (50.8 mm)

2.843 in (72.2 mm)

CSA; UL

125 °C (257 °F)

Very Fast

PSR031DS0350Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

350 A

Tab/Blade

9.523 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.028 in (51.5 mm)

1.937 in (49.2 mm)

Indicator

3.402 in (86.4 mm)

CCC; CUL; UL

125 °C (257 °F)

Fast

PSR030DS0350Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

350 A

Tab/Blade

12.007 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

1.878 in (47.7 mm)

1.693 in (43 mm)

Indicator

3.067 in (77.9 mm)

CCC; CUL; UL

125 °C (257 °F)

Fast

PSR070DL0350Z

Littelfuse

Electric Fuse

Inline/Holder

1.3 KV

1 KV

350 A

Tab/Blade

22.963 kJ

-55 °C (-67 °F)

100 kA

Rated Breaking Capacity at 1000 VDC: 150000 A

Bulk

2.823 in (71.7 mm)

1.693 in (43 mm)

Indicator

3.067 in (77.9 mm)

CUL; UL

125 °C (257 °F)

Fast

PSR072DL0350X

Littelfuse

Electric Fuse

Inline/Holder

1.3 KV

1 KV

350 A

Tab/Blade

18.727 kJ

-55 °C (-67 °F)

100 kA

Rated Breaking Capacity at 1000 VDC: 150000 A

Bulk

2.882 in (73.2 mm)

2.362 in (60 mm)

Indicator

3.736 in (94.9 mm)

CCC; CUL; UL

125 °C (257 °F)

Fast

PSR031DL0350Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

350 A

Tab/Blade

9.523 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.028 in (51.5 mm)

1.937 in (49.2 mm)

Indicator

3.402 in (86.4 mm)

CCC; CUL; UL

125 °C (257 °F)

Fast

PSR071DL0350Z

Littelfuse

Electric Fuse

Inline/Holder

1.3 KV

1 KV

350 A

Tab/Blade

23.301 kJ

-55 °C (-67 °F)

100 kA

Rated Breaking Capacity at 1000 VDC: 150000 A

Bulk

2.882 in (73.2 mm)

2.028 in (51.5 mm)

Indicator

3.402 in (86.4 mm)

CCC; CUL; UL

125 °C (257 °F)

Fast

PSR030DL0350Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

350 A

Tab/Blade

12.007 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

1.878 in (47.7 mm)

1.693 in (43 mm)

Indicator

3.067 in (77.9 mm)

CCC; CUL; UL

125 °C (257 °F)

Fast

PSR073DL0350X

Littelfuse

Electric Fuse

Inline/Holder

1.3 KV

1 KV

350 A

Tab/Blade

13.586 kJ

-55 °C (-67 °F)

100 kA

Rated Breaking Capacity at 1000 VDC: 150000 A

Bulk

2.921 in (74.2 mm)

2.894 in (73.5 mm)

Indicator

4.268 in (108.4 mm)

CCC; CUL; UL

125 °C (257 °F)

Fast

L17T350.V

Littelfuse

Electric Fuse

Inline/Holder

170 V

350 A

Tab/Blade

100 kA

Bulk

1.5 in (38.1 mm)

1.252 in (31.8 mm)

CSA; UL

07945825256

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

350 A

Tab/Blade

12.007 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

1.878 in (47.7 mm)

1.693 in (43 mm)

Indicator

1.929 in (49 mm)

CUL; UL

125 °C (257 °F)

Fast

07945825318

Littelfuse

Electric Fuse

Inline/Holder

1.3 KV

1 KV

350 A

Tab/Blade

18.727 kJ

-55 °C (-67 °F)

100 kA

Rated Breaking Capacity at 1000 VDC: 150000 A

Bulk

2.882 in (73.2 mm)

2.362 in (60 mm)

Indicator

2.598 in (66 mm)

CUL; UL

125 °C (257 °F)

Fast

07945825205

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

350 A

Tab/Blade

12.007 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

1.878 in (47.7 mm)

1.693 in (43 mm)

Indicator

1.929 in (49 mm)

CUL; UL

125 °C (257 °F)

Fast

PSR073UL0350

Littelfuse

Electric Fuse

Inline/Holder

1.3 KV

1 KV

350 A

Tab/Blade

13.586 kJ

-55 °C (-67 °F)

100 kA

Rated Breaking Capacity at 1000 VDC: 150000 A

Bulk

2.921 in (74.2 mm)

2.894 in (73.5 mm)

Indicator

3.13 in (79.5 mm)

CUL; UL

125 °C (257 °F)

Fast

07945825325

Littelfuse

Electric Fuse

Inline/Holder

1.3 KV

1 KV

350 A

Tab/Blade

13.586 kJ

-55 °C (-67 °F)

100 kA

Rated Breaking Capacity at 1000 VDC: 150000 A

Bulk

2.921 in (74.2 mm)

2.894 in (73.5 mm)

Indicator

3.13 in (79.5 mm)

CUL; UL

125 °C (257 °F)

Fast

0JTD350.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

350 A

Tab/Blade

200 kA

Rated Breaking Capacity at 500 VDC: 20000 A

Bulk

2 in (50.8 mm)

3.374 in (85.7 mm)

CSA; UL

Time Delay

PSR031US0350

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

350 A

Tab/Blade

9.523 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.028 in (51.5 mm)

1.937 in (49.2 mm)

Indicator

2.264 in (57.5 mm)

CUL; UL

125 °C (257 °F)

Fast

0998350.UX-2M8

Littelfuse

Electric Fuse

Inline/Holder

70 V

350 A

Tab/Blade

495 kJ

-40 °C (-40 °F)

Tin

2.5 kA

100 ms

Bulk

1.15 in (29.2 mm)

0.748 in (19 mm)

e3

70 V

Mega

0.39 in (9.9 mm)

ISO

125 °C (257 °F)

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.