500 V Fuses 573

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

XEV10-20-1P

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

20 A

Tab/Blade

761 J

-40 °C (-40 °F)

20 kA

0.406 in (10.3 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

125 °C (257 °F)

0ADEC9120-BE

Bel Fuse

Electric Fuse

Inline/Holder

500 V

500 V

12 A

End Cap

140 J

-55 °C (-67 °F)

Silver

30 kA

10 s

Interrupting Current Max(DC): 20000 A, Pre Arcing Time: Open within 10 s at 300% Rated Current

Bulk

0.252 in (6.4 mm)

e4

500 V

0.236 x 1.26 in (6 x 32 mm)

1.252 in (31.8 mm)

CUL; UL

105 °C (221 °F)

Fast

FWH-001A6F

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

1 A

End Cap

2 J

200 kA

Rated Breaking Capacity at 500 VDC: 50000 A

0.4

Box

0.248 in (6.3 mm)

500 V

0.248 x 1.26 in (6.3 x 32 mm)

0.252 x 1.252 in (6.4 x 31.8 mm)

1.26 in (32 mm)

CE; CSA; UL

Fast

FWP-100A22F

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

500 V

100 A

End Cap

1.1 kJ

200 kA

Rated Breaking Capacity at 500 VDC: 50000 A

Box

0.874 in (22.2 mm)

0.874 x 2.283 in (22.2 x 58 mm)

2.283 in (58 mm)

IEC; UL

FWP-50G22FI

Eaton Corporation

Electric Fuse

Inline/Holder

690 V

500 V

50 A

End Cap

273 J

200 kA

Bulk

0.866 in (22 mm)

0.866 x 2.283 in (22 x 58 mm)

Indicator

2.283 in (58 mm)

IEC; UL

0JTD110.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

110 A

Tab/Blade

200 kA

Rated Breaking Capacity at 500 VDC: 20000 A

Bulk

1.5 in (38.1 mm)

3 in (76.2 mm)

CSA; UL

Time Delay

0KLK.100T

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

100 mA

End Cap

100 kA

Rated Breaking Capacity at 500 VDC: 50000 A

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Fast

C22G80S

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

80 A

End Cap

120 kA

C22

0.866 in (22 mm)

0.866 x 2.283 in (22 x 58 mm)

2.283 in (58 mm)

IEC

C22M80

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

80 A

End Cap

120 kA

C22

0.866 in (22 mm)

0.866 x 2.283 in (22 x 58 mm)

2.283 in (58 mm)

IEC

CCMR030.TXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

30 A

End Cap

1.79 kJ

Nickel

200 kA

Rated Breaking Capacity at 500 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

L50QS060.T

Littelfuse

Electric Fuse

Inline/Holder

500 V

500 V

60 A

Tab/Blade

269 J

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 500 VDC: 50000 A

Bulk

1 in (25.4 mm)

10 ms

2.125 in (53.98 mm)

CE; CUL; UL

125 °C (257 °F)

Very Fast

0505016.MXEP

Littelfuse

Electric Fuse

Through Hole Mount

500 V

500 V

16 A

Pin Wire

68 J

-55 °C (-67 °F)

Matte Tin

50 kA

10 s

Rated Breaking Capacity at 500 VDC: 20000 A

68

Bulk

0.275 in (6.985 mm)

e3

500 V

3AB

0.275 x 1.288 in (6.99 x 32.72 mm)

1.288 in (32.72 mm)

CE; CUL; TUV; UL

125 °C (257 °F)

Fast

0ADEC9100-BE

Bel Fuse

Electric Fuse

Inline/Holder

500 V

500 V

10 A

End Cap

100 J

-55 °C (-67 °F)

Silver

30 kA

10 s

Interrupting Current Max(DC): 20000 A, Pre Arcing Time: Open within 10 s at 300% Rated Current

Bulk

0.252 in (6.4 mm)

e4

500 V

0.236 x 1.26 in (6 x 32 mm)

1.252 in (31.8 mm)

CUL; UL

105 °C (221 °F)

Fast

C10G2

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

2 A

End Cap

120 kA

C10

0.394 in (10 mm)

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

IEC

C14M20I

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

20 A

End Cap

120 kA

C14

0.551 in (14 mm)

Indicator

0.551 x 2.008 in (14 x 51 mm)

2.008 in (51 mm)

IEC

C22G80I

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

80 A

End Cap

120 kA

C22

0.866 in (22 mm)

Indicator

0.866 x 2.283 in (22 x 58 mm)

2.283 in (58 mm)

IEC

CCMR025.TXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

25 A

End Cap

Nickel

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

F60C500V30AS

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

30 A

End Cap

200 kA

Rated Breaking Capacity at 500 VDC: 150000 A

0.406 in (10.31 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

MIL-PRF-15160/60

FNQ-2-1/4

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

2.25 A

End Cap

Nickel

10 kA

Bulk

0.41 in (10.41 mm)

CC

500 V

Midget

0.41 x 1.5 in (10.41 x 38.1 mm)

1.5 in (38.1 mm)

CE, CSA, UL

Time Delay

FWH-.500A6F

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

500 mA

End Cap

50 mJ

50 kA

Rated Breaking Capacity at 500 VDC: 50000 A

Box

0.252 in (6.4 mm)

0.252 x 1.252 in (6.4 x 31.8 mm)

1.252 in (31.8 mm)

CE; CSA; UL

FWH-007A6F

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

7 A

End Cap

50 J

50 kA

Rated Breaking Capacity at 500 VDC: 50000 A

Box

0.252 in (6.4 mm)

0.252 x 1.252 in (6.4 x 31.8 mm)

1.252 in (31.8 mm)

CE; CSA; UL

FWH-175B

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

175 A

Tab/Blade

1.45 kJ

200 kA

Rated Breaking Capacity at 500 VDC: 50000 A

Box

1.156 in (29.36 mm)

1.156 x 1.836 in (29.36 x 46.63 mm)

1.836 in (46.63 mm)

CE; CSA; UL

KLK.100

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

100 mA

End Cap

100 kA

Rated Breaking Capacity at 500 VDC: 50000 A

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Fast

L214577

Mersen S A

Electric Fuse

Inline/Holder

500 V

500 V

6 A

End Cap

Bulk

0.866 in (22 mm)

Dll

1.969 in (50 mm)

CE; EAC

0505020.MXP

Littelfuse

Electric Fuse

Inline/Holder

500 V

500 V

20 A

End Cap

140 J

-55 °C (-67 °F)

Nickel

30 kA

10 s

Rated Breaking Capacity at 500 VDC: 20000 A

140

Bulk

0.25 in (6.35 mm)

500 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

125 °C (257 °F)

Fast

0505030.MXEP

Littelfuse

Electric Fuse

Through Hole Mount

500 V

500 V

30 A

Pin Wire

280 J

-55 °C (-67 °F)

Matte Tin

30 kA

10 s

Rated Breaking Capacity at 500 VDC: 20000 A

280

Bulk

0.275 in (6.985 mm)

e3

500 V

3AB

0.275 x 1.288 in (6.99 x 32.72 mm)

1.288 in (32.72 mm)

125 °C (257 °F)

Fast

0ADEC9200-BE

Bel Fuse

Electric Fuse

Inline/Holder

500 V

500 V

20 A

End Cap

120 J

-55 °C (-67 °F)

Silver

30 kA

10 s

Interrupting Current Max(DC): 20000 A, Pre Arcing Time: Open within 10 s at 300% Rated Current

Bulk

0.252 in (6.4 mm)

e4

500 V

0.236 x 1.26 in (6 x 32 mm)

1.252 in (31.8 mm)

CUL; UL

105 °C (221 °F)

Fast

0AKRBK150-BB

Bel Fuse

Electric Fuse

Inline/Holder

500 V

150 A

Tab/Blade

-40 °C (-40 °F)

Tin

50 kA

Bulk

1.929 in (49 mm)

1.457 in (37 mm)

e3

0.945 in (24 mm)

105 °C (221 °F)

0JTD225.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

225 A

Tab/Blade

200 kA

Rated Breaking Capacity at 500 VDC: 20000 A

Bulk

2 in (50.8 mm)

3.374 in (85.7 mm)

CSA; UL

Time Delay

0JTD225.XXID

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

225 A

Tab/Blade

200 kA

Rated Breaking Capacity at 500 VDC: 20000 A

Bulk

2 in (50.8 mm)

Indicator

3.374 in (85.7 mm)

CSA; UL

Time Delay

0NLS600.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

600 A

Tab/Blade

6.92 MJ

200 kA

Rated Breaking Capacity at 500 VDC: 20000 A

3.094 in (78.6 mm)

Indicator

10.374 in (263.5 mm)

CSA; UL

7012540.0,5

Siba

Electric Fuse

Inline/Holder

700 V

500 V

500 mA

End Cap

120 mJ

Nickel

50 kA

Rated Breaking Capacity at 500 VDC: 20000 A

Bulk

0.25 in (6.35 mm)

6 ms

0.25 x 1.252 in (6.35 x 31.8 mm)

1.252 in (31.8 mm)

CUL; UL

Very Fast

AJT175N

Mersen S A

Electric Fuse

Inline/Holder

600 V

500 V

175 A

Tab/Blade

200 kA

1.614 in (41 mm)

5.748 in (146 mm)

CSA; IEC; UL

Time Delay

AJT400

Mersen S A

Electric Fuse

Inline/Holder

600 V

500 V

400 A

Tab/Blade

200 kA

Rated Breaking Capacity at 500 VDC: 100000 A

2.126 in (54 mm)

Indicator

2.126 x 3.346 in (54 x 85 mm)

7.126 in (181 mm)

Time Delay

AJT400N

Mersen S A

Electric Fuse

Inline/Holder

600 V

500 V

400 A

Tab/Blade

200 kA

2.126 in (54 mm)

7.126 in (181 mm)

CSA; IEC; UL

Time Delay

C10M10

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

10 A

End Cap

120 kA

0.394 in (10 mm)

500 V

5AG

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

IEC

F60C500V1/8A

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

125 mA

End Cap

Nickel

0.406 in (10.3 mm)

500 V

Midget

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CSA; MIL-F-15160/60; UL

Fast

F60C500V6A

Littelfuse

Electric Fuse

Inline/Holder

500 V

500 V

6 A

End Cap

Nickel

200 kA

Rated Breaking Capacity at 500 VDC: 150000 A

0.406 in (10.31 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

MIL-PRF-15160/60

FNQ-1-1/2

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

1.5 A

End Cap

10 kA

Bulk

0.406 in (10.3 mm)

CC

500 V

Midget

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE, CSA, UL

Time Delay

FNQ-14

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

14 A

End Cap

10 kA

Bulk

0.41 in (10.41 mm)

CC

500 V

Midget

0.41 x 1.5 in (10.41 x 38.1 mm)

1.5 in (38.1 mm)

CE, CSA, UL

Time Delay

FNQ-2-1/2

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

2.5 A

End Cap

Nickel

10 kA

Bulk

0.406 in (10.3 mm)

CC

500 V

Midget

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE, CSA, UL

Time Delay

FNQ-2/10

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

200 mA

End Cap

Nickel

10 kA

Bulk

0.406 in (10.3 mm)

CC

500 V

Midget

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE, CSA, UL

Time Delay

FNQ-8

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

8 A

End Cap

Nickel

10 kA

Bulk

0.41 in (10.41 mm)

CC

500 V

Midget

0.41 x 1.5 in (10.41 x 38.1 mm)

1.5 in (38.1 mm)

CE, CSA, UL

Time Delay

FWH-100B

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

100 A

Tab/Blade

475 J

200 kA

Rated Breaking Capacity at 500 VDC: 50000 A

Box

0.947 in (24.05 mm)

0.947 x 1.736 in (24.05 x 44.09 mm)

1.736 in (44.09 mm)

CE; CSA; UL

FWH-800A

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

800 A

Tab/Blade

76.2 kJ

200 kA

Rated Breaking Capacity at 500 VDC: 50000 A

Box

2.5 in (63.5 mm)

2.5 x 2.09 in (63.5 x 53.09 mm)

2.09 in (53.09 mm)

CE; CSA; UL

FWP-100A22FI

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

500 V

100 A

End Cap

1.1 kJ

200 kA

Rated Breaking Capacity at 500 VDC: 50000 A

0.874 in (22.2 mm)

Indicator

0.874 x 2.283 in (22.2 x 58 mm)

2.283 in (58 mm)

CE; IEC; UL

FWP-63A22FA

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

500 V

63 A

End Cap

280 J

200 kA

Rated Breaking Capacity at 500 VDC: 50000 A

0.874 in (22.2 mm)

0.874 x 2.283 in (22.2 x 58 mm)

2.283 in (58 mm)

CE; IEC; UL

HSJ25

Mersen S A

Electric Fuse

Inline/Holder

600 V

500 V

25 A

End Cap

200 kA

0.827 in (21 mm)

2.244 in (57 mm)

CSA; UL

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.