500 V Fuses 573

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

10EV015.ZXISO

Littelfuse

Electric Fuse

Inline/Holder

500 V

15 A

Tab/Blade

803 J

-40 °C (-40 °F)

20 kA

50 ms

Bulk

0.406 in (10.3 mm)

1.531 in (38.9 mm)

125 °C (257 °F)

Time Delay

10EV020.ZXBDP

Littelfuse

Electric Fuse

Inline/Holder

500 V

20 A

Tab/Blade

-40 °C (-40 °F)

20 kA

50 ms

Bulk

0.406 in (10.3 mm)

1.531 in (38.9 mm)

125 °C (257 °F)

Time Delay

10EV030.ZXPCB

Littelfuse

Electric Fuse

Inline/Holder

500 V

30 A

Tab/Blade

1.527 kJ

-40 °C (-40 °F)

20 kA

50 ms

Bulk

0.406 in (10.3 mm)

1.531 in (38.9 mm)

125 °C (257 °F)

Time Delay

10EV040.ZXPCBL

Littelfuse

Electric Fuse

Inline/Holder

500 V

40 A

Tab/Blade

4.45 kJ

-40 °C (-40 °F)

20 kA

50 ms

Bulk

0.406 in (10.3 mm)

1.531 in (38.9 mm)

125 °C (257 °F)

Time Delay

10EV015.ZXPY

Littelfuse

Electric Fuse

Inline/Holder

500 V

15 A

Tab/Blade

803 J

-40 °C (-40 °F)

20 kA

50 ms

Bulk

0.406 in (10.3 mm)

1.531 in (38.9 mm)

125 °C (257 °F)

Time Delay

10EV015.ZXPCBL

Littelfuse

Electric Fuse

Inline/Holder

500 V

15 A

Tab/Blade

803 J

-40 °C (-40 °F)

20 kA

50 ms

Bulk

0.406 in (10.3 mm)

1.531 in (38.9 mm)

125 °C (257 °F)

Time Delay

10EV015.ZXPCB

Littelfuse

Electric Fuse

Inline/Holder

500 V

15 A

Tab/Blade

803 J

-40 °C (-40 °F)

20 kA

50 ms

Bulk

0.406 in (10.3 mm)

1.531 in (38.9 mm)

125 °C (257 °F)

Time Delay

10EV010.ZXBDP

Littelfuse

Electric Fuse

Inline/Holder

500 V

10 A

Tab/Blade

316 J

-40 °C (-40 °F)

20 kA

50 ms

Bulk

0.406 in (10.3 mm)

1.531 in (38.9 mm)

125 °C (257 °F)

Time Delay

10EV030.ZXBDP

Littelfuse

Electric Fuse

Inline/Holder

500 V

30 A

Tab/Blade

1.527 kJ

-40 °C (-40 °F)

20 kA

50 ms

Bulk

0.406 in (10.3 mm)

1.531 in (38.9 mm)

125 °C (257 °F)

Time Delay

10EV020.ZXPY

Littelfuse

Electric Fuse

Inline/Holder

500 V

20 A

Tab/Blade

-40 °C (-40 °F)

20 kA

50 ms

Bulk

0.406 in (10.3 mm)

1.531 in (38.9 mm)

125 °C (257 °F)

Time Delay

10EV015.ZXBDP

Littelfuse

Electric Fuse

Inline/Holder

500 V

15 A

Tab/Blade

803 J

-40 °C (-40 °F)

20 kA

50 ms

Bulk

0.406 in (10.3 mm)

1.531 in (38.9 mm)

125 °C (257 °F)

Time Delay

10EV010.ZXPY

Littelfuse

Electric Fuse

Inline/Holder

500 V

10 A

Tab/Blade

316 J

-40 °C (-40 °F)

20 kA

50 ms

Bulk

0.406 in (10.3 mm)

1.531 in (38.9 mm)

125 °C (257 °F)

Time Delay

10EV040.ZXBDP

Littelfuse

Electric Fuse

Inline/Holder

500 V

40 A

Tab/Blade

4.45 kJ

-40 °C (-40 °F)

20 kA

50 ms

Bulk

0.406 in (10.3 mm)

1.531 in (38.9 mm)

125 °C (257 °F)

Time Delay

10EV020.ZXC

Littelfuse

Electric Fuse

Inline/Holder

500 V

20 A

End Cap

-40 °C (-40 °F)

20 kA

50 ms

Bulk

0.406 in (10.3 mm)

1.531 in (38.9 mm)

125 °C (257 °F)

Time Delay

10EV050.ZXPCBL

Littelfuse

Electric Fuse

Inline/Holder

500 V

50 A

Tab/Blade

7.803 kJ

-40 °C (-40 °F)

20 kA

50 ms

Bulk

0.406 in (10.3 mm)

1.531 in (38.9 mm)

125 °C (257 °F)

Time Delay

10EV010.ZXC

Littelfuse

Electric Fuse

Inline/Holder

500 V

10 A

End Cap

316 J

-40 °C (-40 °F)

20 kA

50 ms

Bulk

0.406 in (10.3 mm)

1.531 in (38.9 mm)

125 °C (257 °F)

Time Delay

10EV030.ZXPY

Littelfuse

Electric Fuse

Inline/Holder

500 V

30 A

Tab/Blade

1.527 kJ

-40 °C (-40 °F)

20 kA

50 ms

Bulk

0.406 in (10.3 mm)

1.531 in (38.9 mm)

125 °C (257 °F)

Time Delay

10EV020.ZXPCBL

Littelfuse

Electric Fuse

Inline/Holder

500 V

20 A

Tab/Blade

-40 °C (-40 °F)

20 kA

50 ms

Bulk

0.406 in (10.3 mm)

1.531 in (38.9 mm)

125 °C (257 °F)

Time Delay

10EV050.ZXBDP

Littelfuse

Electric Fuse

Inline/Holder

500 V

50 A

Tab/Blade

7.803 kJ

-40 °C (-40 °F)

20 kA

50 ms

Bulk

0.406 in (10.3 mm)

1.531 in (38.9 mm)

125 °C (257 °F)

Time Delay

10EV010.ZXISO

Littelfuse

Electric Fuse

Inline/Holder

500 V

10 A

Tab/Blade

316 J

-40 °C (-40 °F)

20 kA

50 ms

Bulk

0.406 in (10.3 mm)

1.531 in (38.9 mm)

125 °C (257 °F)

Time Delay

10EV030.ZXISO

Littelfuse

Electric Fuse

Inline/Holder

500 V

30 A

Tab/Blade

1.527 kJ

-40 °C (-40 °F)

20 kA

50 ms

Bulk

0.406 in (10.3 mm)

1.531 in (38.9 mm)

125 °C (257 °F)

Time Delay

10EV020.ZXPCB

Littelfuse

Electric Fuse

Inline/Holder

500 V

20 A

Tab/Blade

-40 °C (-40 °F)

20 kA

50 ms

Bulk

0.406 in (10.3 mm)

1.531 in (38.9 mm)

125 °C (257 °F)

Time Delay

10EV040.ZXISO

Littelfuse

Electric Fuse

Inline/Holder

500 V

40 A

Tab/Blade

4.45 kJ

-40 °C (-40 °F)

20 kA

50 ms

Bulk

0.406 in (10.3 mm)

1.531 in (38.9 mm)

125 °C (257 °F)

Time Delay

10EV030.ZXPCBL

Littelfuse

Electric Fuse

Inline/Holder

500 V

30 A

Tab/Blade

1.527 kJ

-40 °C (-40 °F)

20 kA

50 ms

Bulk

0.406 in (10.3 mm)

1.531 in (38.9 mm)

125 °C (257 °F)

Time Delay

10EV030.ZXC

Littelfuse

Electric Fuse

Inline/Holder

500 V

30 A

End Cap

1.527 kJ

-40 °C (-40 °F)

20 kA

50 ms

Bulk

0.406 in (10.3 mm)

1.531 in (38.9 mm)

125 °C (257 °F)

Time Delay

0JTD110.XXID

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

110 A

Tab/Blade

200 kA

Rated Breaking Capacity at 500 VDC: 20000 A

Bulk

1.5 in (38.1 mm)

Indicator

3 in (76.2 mm)

CSA; UL

Time Delay

0JTD500.XXID

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

500 A

Tab/Blade

200 kA

Rated Breaking Capacity at 500 VDC: 20000 A

Bulk

2.5 in (63.5 mm)

Indicator

3.752 in (95.3 mm)

CSA; UL

Time Delay

0JTD450.XXID

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

450 A

Tab/Blade

200 kA

Rated Breaking Capacity at 500 VDC: 20000 A

Bulk

2.5 in (63.5 mm)

Indicator

3.752 in (95.3 mm)

CSA; UL

Time Delay

30EV175.ZXBDM

Littelfuse

Electric Fuse

Inline/Holder

500 V

175 A

Tab/Blade

22 kJ

-40 °C (-40 °F)

30 kA

50 ms

1.181 in (30 mm)

2.047 in (52 mm)

CSA; UL

125 °C (257 °F)

Time Delay

30EV225.ZXBDM

Littelfuse

Electric Fuse

Inline/Holder

500 V

225 A

Tab/Blade

41 kJ

-40 °C (-40 °F)

30 kA

50 ms

1.181 in (30 mm)

2.047 in (52 mm)

CSA; UL

125 °C (257 °F)

Time Delay

0JTD300.XXID

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

300 A

Tab/Blade

200 kA

Rated Breaking Capacity at 500 VDC: 20000 A

Bulk

2 in (50.8 mm)

Indicator

3.374 in (85.7 mm)

CSA; UL

Time Delay

0JTD350.XXID

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

350 A

Tab/Blade

200 kA

Rated Breaking Capacity at 500 VDC: 20000 A

Bulk

2 in (50.8 mm)

Indicator

3.374 in (85.7 mm)

CSA; UL

Time Delay

30EV300.ZXBDM

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 A

Tab/Blade

101 kJ

-40 °C (-40 °F)

30 kA

50 ms

1.181 in (30 mm)

2.047 in (52 mm)

CSA; UL

125 °C (257 °F)

Time Delay

JTD170ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

175 A

Tab/Blade

200 kA

Rated Breaking Capacity at 500 VDC: 20000 A

Bulk

1.5 in (38.1 mm)

Indicator

3 in (76.2 mm)

CSA; UL

Time Delay

0JTD250.XXID

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

250 A

Tab/Blade

200 kA

Rated Breaking Capacity at 500 VDC: 20000 A

Bulk

2 in (50.8 mm)

Indicator

3.374 in (85.7 mm)

CSA; UL

Time Delay

30EV250.ZXBDM

Littelfuse

Electric Fuse

Inline/Holder

500 V

250 A

Tab/Blade

52 kJ

-40 °C (-40 °F)

30 kA

50 ms

1.181 in (30 mm)

2.047 in (52 mm)

CSA; UL

125 °C (257 °F)

Time Delay

30EV200.ZXBDM

Littelfuse

Electric Fuse

Inline/Holder

500 V

200 A

Tab/Blade

32 kJ

-40 °C (-40 °F)

30 kA

50 ms

1.181 in (30 mm)

2.047 in (52 mm)

CSA; UL

125 °C (257 °F)

Time Delay

0JTD150.XXID

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

150 A

Tab/Blade

200 kA

Rated Breaking Capacity at 500 VDC: 20000 A

Bulk

1.5 in (38.1 mm)

Indicator

3 in (76.2 mm)

CSA; UL

Time Delay

30EV150.ZXBDM

Littelfuse

Electric Fuse

Inline/Holder

500 V

150 A

Tab/Blade

15 kJ

-40 °C (-40 °F)

30 kA

50 ms

1.181 in (30 mm)

2.047 in (52 mm)

CSA; UL

125 °C (257 °F)

Time Delay

07945825242

Littelfuse

Electric Fuse

Inline/Holder

650 V

500 V

1.5 kA

Tab/Blade

674.538 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 500 VDC: 150000 A

Bulk

2.894 in (73.5 mm)

1.976 in (50.2 mm)

Indicator

3.13 in (79.5 mm)

CUL; UL

125 °C (257 °F)

Fast

PSR033UL1400

Littelfuse

Electric Fuse

Inline/Holder

700 V

500 V

1.4 kA

Tab/Blade

583.552 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 500 VDC: 150000 A

Bulk

2.894 in (73.5 mm)

1.976 in (50.2 mm)

Indicator

3.13 in (79.5 mm)

CUL; UL

125 °C (257 °F)

Fast

KLK009

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

9 A

End Cap

100 kA

Rated Breaking Capacity at 500 VDC: 50000 A

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Fast

0JTD300.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

300 A

Tab/Blade

200 kA

Rated Breaking Capacity at 500 VDC: 20000 A

Bulk

2 in (50.8 mm)

3.374 in (85.7 mm)

CSA; UL

Time Delay

PSR033UL1500

Littelfuse

Electric Fuse

Inline/Holder

650 V

500 V

1.5 kA

Tab/Blade

674.538 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 500 VDC: 150000 A

Bulk

2.894 in (73.5 mm)

1.976 in (50.2 mm)

Indicator

3.13 in (79.5 mm)

CUL; UL

125 °C (257 °F)

Fast

PSR033US1250

Littelfuse

Electric Fuse

Inline/Holder

700 V

500 V

1.25 kA

Tab/Blade

476.902 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 500 VDC: 150000 A

Bulk

2.894 in (73.5 mm)

1.976 in (50.2 mm)

Indicator

3.13 in (79.5 mm)

CUL; UL

125 °C (257 °F)

Fast

PSR033US1800

Littelfuse

Electric Fuse

Inline/Holder

650 V

500 V

1.8 kA

Tab/Blade

952.196 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 500 VDC: 150000 A

Bulk

2.894 in (73.5 mm)

1.976 in (50.2 mm)

Indicator

3.13 in (79.5 mm)

CUL; UL

125 °C (257 °F)

Fast

07945825293

Littelfuse

Electric Fuse

Inline/Holder

650 V

500 V

1.5 kA

Tab/Blade

674.538 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 500 VDC: 150000 A

Bulk

2.894 in (73.5 mm)

1.976 in (50.2 mm)

Indicator

3.13 in (79.5 mm)

CUL; UL

125 °C (257 °F)

Fast

07945825243

Littelfuse

Electric Fuse

Inline/Holder

650 V

500 V

1.6 kA

Tab/Blade

779.948 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 500 VDC: 150000 A

Bulk

2.894 in (73.5 mm)

1.976 in (50.2 mm)

Indicator

3.13 in (79.5 mm)

CUL; UL

125 °C (257 °F)

Fast

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.