End Cap Fuses 2,400+

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

02170.25HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 mA

End Cap

40 mJ

-55 °C (-67 °F)

35 A

10 ms

Pre Arcing Time: Open within 10 ms at 400% Rated Current

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; CUL; KC; SEMKO; UL; VDE

125 °C (257 °F)

Fast

0217004.HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

4 A

End Cap

29.165 J

-55 °C (-67 °F)

Matte Tin

40 A

10 ms

29.165

Bulk

0.205 in (5.2 mm)

e3

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; KC; PSE; SEMKO; SEV; UL; VDE

125 °C (257 °F)

Very Fast

0217010.MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

10 A

End Cap

217.635 J

-55 °C (-67 °F)

Nickel

100 A

10 ms

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; CSA; PSE; UL; VDE

125 °C (257 °F)

Very Fast

0217015.HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

15 A

End Cap

607.135 J

-55 °C (-67 °F)

Nickel

150 A

10 ms

607.13

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; IEC; PSE; VDE

125 °C (257 °F)

Very Fast

021702.5HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

2.5 A

End Cap

9.46 J

-55 °C (-67 °F)

Matte Tin

35 A

10 ms

9.46

Bulk

0.205 in (5.2 mm)

e3

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; KC; PSE; SEMKO; SEV; UL; VDE

125 °C (257 °F)

Very Fast

0218.125MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 mA

End Cap

146.5 mJ

-55 °C (-67 °F)

Nickel

35 A

20 ms

0.1465

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; KC; SEMKO; SEV; UL; VDE

125 °C (257 °F)

Time Lag

0218.160HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

160 mA

End Cap

144 mJ

-55 °C (-67 °F)

Matte Tin

35 A

0.144

Bulk

0.205 in (5.2 mm)

Supplemental

e3

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; KC; SEMKO; UL; VDE

125 °C (257 °F)

Time Lag

0218.400TXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

400 mA

End Cap

1.325 J

-55 °C (-67 °F)

Matte Tin

35 A

20 ms

1.325

Bulk

0.205 in (5.2 mm)

Supplemental

e3

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

BSI, CCC, CE, CSA, KC, SEMKO, UL, VDE

125 °C (257 °F)

Time Lag

02181.25MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

1.25 A

End Cap

12.65 J

-55 °C (-67 °F)

Nickel

35 A

20 ms

Bulk

0.205 in (5.2 mm)

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; KC; PSE; SEMKO; SEV; UL; VDE

125 °C (257 °F)

Time Lag

021812.5MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

12.5 A

End Cap

889 J

-55 °C (-67 °F)

Matte Tin

63 A

20 ms

Bulk

0.205 in (5.2 mm)

e3

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; PSE; UL

125 °C (257 °F)

Time Lag

0229003.HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

3 A

End Cap

77 J

-55 °C (-67 °F)

Tin

100 A

Rated Breaking Capacity at 125 VDC: 10000 A

Bulk

0.177 in (4.5 mm)

e3

Indicator

0.177 x 0.57 in (4.5 x 14.48 mm)

0.57 in (14.48 mm)

CE; CSA; PSE; UL

125 °C (257 °F)

Time Lag

0313.200HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

200 mA

End Cap

270 mJ

-55 °C (-67 °F)

Nickel

35 A

4 h

0.27

Bulk

0.25 in (6.35 mm)

Supplemental

250 V

3AG

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; UL

125 °C (257 °F)

Time Lag

0314030.MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

30 A

End Cap

2.49 kJ

-55 °C (-67 °F)

Nickel

100 A

Rated Breaking Capacity at 125 VDC: 400 A

2490

Bulk

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CUL; KC; PSE; UL

125 °C (257 °F)

Fast

0326001.VXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 V

1 A

End Cap

16.3 J

-55 °C (-67 °F)

Nickel

100 A

5 s

Pre Arcing Time: Open within 5 s at 200% Rated Current

16.3

Bulk

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE, CSA, PSE, UL

125 °C (257 °F)

Time Lag

0326020.HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 V

20 A

End Cap

575 J

-55 °C (-67 °F)

Nickel

400 A

4 h

575

Bulk

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; KC; PSE; UL

125 °C (257 °F)

Time Lag

03266.25HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 V

6.25 A

End Cap

60.4 J

-55 °C (-67 °F)

Nickel

400 A

4 h

60.4

Bulk

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; PSE; UL

125 °C (257 °F)

Time Lag

0477001.MXP

Littelfuse

Electric Fuse

Inline/Holder

500 V

400 V

1 A

End Cap

1.8 J

-55 °C (-67 °F)

Nickel

100 A

10 ms

Rated Breaking Capacity at 400 VDC: 1500 A

1.8

Bulk

0.205 in (5.2 mm)

500 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

PSE; VDE

125 °C (257 °F)

Time Lag

04773.15MXP

Littelfuse

Electric Fuse

Inline/Holder

500 V

400 V

3.15 A

End Cap

50.109 J

-55 °C (-67 °F)

Nickel

100 A

10 ms

Rated Breaking Capacity at 400 VDC: 1500 A

50.1

Bulk

0.205 in (5.2 mm)

500 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

PSE; VDE

125 °C (257 °F)

Time Lag

0505016.MXP

Littelfuse

Electric Fuse

Inline/Holder

500 V

500 V

16 A

End Cap

68 J

-55 °C (-67 °F)

Nickel

50 kA

10 s

Rated Breaking Capacity at 500 VDC: 20000 A

68

Bulk

0.25 in (6.35 mm)

500 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CUL; TUV; UL

125 °C (257 °F)

Fast

0SPF015.TXS

Littelfuse

Electric Fuse

Inline/Holder

1 KV

15 A

End Cap

505 J

Silver

20 kA

4 m

Bulk

0.406 in (10.31 mm)

e4

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL

170M6546

Eaton Corporation

Electric Fuse

Inline/Holder

1.3 KV

800 A

End Cap

205 kJ

100 kA

3.189 in (81 mm)

2.992 in (76 mm)

Indicator

3.189 x 2.992 x 2.992 in (81 x 76 x 76 mm)

2.992 in (76 mm)

CE; IEC; UL

3AG2.5-R

Bel Fuse

Electric Fuse

Inline/Holder

250 V

2.5 A

End Cap

12 J

-55 °C (-67 °F)

200 A

Pre-Arcing Time: Open within 5 s, at 200% Rated Current

Bulk; Tape And Reel

0.25 in (6.35 mm)

250 V

0.25 x 1.252 in (6.35 x 31.8 mm)

1.252 in (31.8 mm)

CE; CSA; PSE; UL

125 °C (257 °F)

Fast

5012434.16

Siba

Electric Fuse

Inline/Holder

690 V

440 V

16 A

End Cap

25 J

200 kA

Rated Breaking Capacity at 440 VDC: 30000 A

Bulk

0.551 in (14 mm)

30 ms

0.551 x 2.008 in (14 x 51 mm)

2.008 in (51 mm)

IEC, UL, VDE

5ST100-R

Bel Fuse

Electric Fuse

Inline/Holder

250 V

100 mA

End Cap

30 mJ

-55 °C (-67 °F)

Nickel

35 A

Bulk; Tape And Reel

0.201 in (5.1 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.201 x 0.787 in (5.1 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; SEMKO; UL; VDE

125 °C (257 °F)

Time Lag

5ST500-R

Bel Fuse

Electric Fuse

Inline/Holder

250 V

500 mA

End Cap

1.4 J

-55 °C (-67 °F)

Nickel

35 A

Bulk; Tape And Reel

0.201 in (5.1 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.201 x 0.787 in (5.1 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; SEMKO; UL; VDE

125 °C (257 °F)

Time Lag

7017240.1,6

Siba

Electric Fuse

Inline/Holder

1 KV

1 KV

1.6 A

End Cap

310 mJ

30 kA

Bulk

0.25 in (6.35 mm)

1 ms

0.248 x 1.26 in (6.3 x 32 mm)

1.252 in (31.8 mm)

UL

Very Fast

7022.0660

Schurter Ag

Electric Fuse

Inline/Holder

500 V

4 A

End Cap

8.4 J

-40 °C (-40 °F)

Tin/Tin Copper

150 kA

Bulk

0.25 in (6.35 mm)

e3/e2

3600 s

0.248 x 1.26 in (6.3 x 32 mm)

0.25 x 1.252 in (6.35 x 31.8 mm)

1.252 in (31.8 mm)

UL

85 °C (185 °F)

Super Fast

8020.5083

Schurter Ag

Electric Fuse

Inline/Holder

440 V

63 V

32 A

End Cap

4.75 kJ

-40 °C (-40 °F)

1.5 kA

4750

Bulk

0.25 in (6.35 mm)

20 ms

0.248 x 1.26 in (6.3 x 32 mm)

0.25 x 1.252 in (6.35 x 31.8 mm)

1.252 in (31.8 mm)

CUL, UL

85 °C (185 °F)

Very Fast

ABC-1/4-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 V

250 mA

End Cap

2 mJ

Nickel

35 A

2 m

Pre Arcing Time: Open within 120 s at 200% Rated Current

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA; UL

Fast

AGC-1

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

1 A

End Cap

1.615 J

35 A

1.615

0.25 in (6.35 mm)

250 V

0.248 x 1.26 in (6.3 x 32 mm)

0.248 x 1.26 in (6.3 x 32 mm)

1.25 in (31.75 mm)

CSA; UL

Fast

AGC-1/4

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

250 mA

End Cap

14.8 mJ

Nickel

35 A

0.25 in (6.35 mm)

32 V

0.248 x 1.26 in (6.3 x 32 mm)

0.248 x 1.26 in (6.3 x 32 mm)

1.25 in (31.75 mm)

CSA; UL

Fast

AGC-14

Eaton Corporation

Electric Fuse

Inline/Holder

32 V

14 A

End Cap

1 kA

0.25 in (6.35 mm)

32 V

0.248 x 1.26 in (6.3 x 32 mm)

1.25 in (31.75 mm)

CSA; UL

Fast

AGC1

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

1 A

End Cap

0.25 in (6.35 mm)

32 V

3AG

1.25 in (31.75 mm)

AGX-10

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

10 A

End Cap

Nickel

200 A

Pre Arcing Time: OPEN within 2 MIN at 200% RATED CURRENT

0.25 in (6.35 mm)

250 V

0.248 x 1 in (6.3 x 25.4 mm)

0.252 x 1 in (6.4 x 25.4 mm)

1 in (25.4 mm)

CUL

Fast

ATDR6-1/4

Mersen S A

Electric Fuse

Inline/Holder

600 V

300 V

6.25 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 100000 A

0.409 in (10.4 mm)

0.409 x 1.5 in (10.4 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

ATQR8

Mersen S A

Electric Fuse

Inline/Holder

600 V

300 V

8 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 100000 A

0.409 in (10.4 mm)

0.409 x 1.5 in (10.4 x 38.1 mm)

1.5 in (38.1 mm)

CSA, CE, UL

80 °C (176 °F)

Time Delay

BBS-20

Eaton Corporation

Electric Fuse

20 A

End Cap

0.41 in (10.41 mm)

48 V

0.41 x 1.38 in (10.41 x 35.05 mm)

1.38 in (35.05 mm)

CE

Fast

BBS-6

Eaton Corporation

Electric Fuse

6 A

End Cap

10 kA

0.41 in (10.41 mm)

600 V

0.41 x 1.38 in (10.41 x 35.05 mm)

1.38 in (35.05 mm)

CE, CSA, UL

Fast

BK-GMD-800-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

800 mA

End Cap

6.6 J

Nickel

35 A

Pre Arcing Time: Open within 5 s at 200% Rated Current

6.6

Box

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CSA; PSE/JET; UL

Time Delay

BK/AGC-1/4-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

250 mA

End Cap

14.8 mJ

Nickel

35 A

Box

0.25 in (6.35 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA; UL

Fast

BK/AGC-14-R

Eaton Corporation

Electric Fuse

Inline/Holder

32 V

14 A

End Cap

Nickel

1 kA

Box

0.25 in (6.35 mm)

32 V

0.248 x 1.26 in (6.3 x 32 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA; UL

Fast

BK/GMD-800-R

Cooper Industries

Electric Fuse

Inline/Holder

250 V

800 mA

End Cap

6.6 J

Nickel

35 A

6.6

Box

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CSA; UL

Time Delay

BK/MDA-2-1/2-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 V

2.5 A

End Cap

31.79 J

Nickel

200 A

2 m

Rated Breaking Capacity at 125 VDC: 10000 A

Box

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA, UL

Time Delay

BK/S506-1.25-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

1.25 A

End Cap

10.05 J

Nickel

35 A

10.05

Bulk

0.205 in (5.2 mm)

250 V

20 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

BSI; CCC; CSA; IMQ; PSE; SEMKO; UL; VDE

Time Delay

BK/S506-125-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 mA

End Cap

63 mJ

Nickel

35 A

0.063

Bulk

0.205 in (5.2 mm)

250 V

20 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

BSI; CCC; CSA; IMQ; SEMKO; UL; VDE

Time Delay

BK/S506-12.5-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

12.5 A

End Cap

1.02 kJ

Nickel

125 A

1019.5

Bulk

0.205 in (5.2 mm)

250 V

20 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

PSE; UL

Time Delay

BK1-S505-2-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

2 A

End Cap

9.6 J

-55 °C (-67 °F)

Nickel

1.5 kA

9.6

Bulk

0.205 in (5.2 mm)

250 V

10 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

BSI, CCC, CSA, CUL, IMQ, KC, PSE, SEMKO, UL, VDE

125 °C (257 °F)

Time Delay

BK1/S505-2-R

Cooper Industries

Electric Fuse

Inline/Holder

250 V

2 A

End Cap

9.6 J

Nickel

1.5 kA

9.6

Bag

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

BSI; CCC/CQC; CSA; IEC; IMQ; KC; PSE/JET; SEMKO; UL; VDE

Time Delay

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.