End Cap Fuses 2,400+

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

0225.500HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

500 mA

End Cap

365 mJ

-55 °C (-67 °F)

Tin

35 A

1 s

Rated Breaking Capacity at 125 VDC: 10000 A

0.365

Bulk

0.189 in (4.8 mm)

e3

250 V

2AG

0.57 x 0.57 in (14.48 x 14.48 mm)

0.587 in (14.9 mm)

CE, CSA, UL

125 °C (257 °F)

Fast

0229007.MXP

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

7 A

End Cap

464 J

-55 °C (-67 °F)

Matte Tin

400 A

3 s

464

Bulk

0.189 in (4.8 mm)

e3

125 V

2AG

0.177 x 0.57 in (4.5 x 14.48 mm)

0.587 in (14.9 mm)

CE; CSA; PSE; UL

125 °C (257 °F)

Time Lag

0239003.HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

3 A

End Cap

129.51 J

-55 °C (-67 °F)

Nickel

100 A

4 h

129.5

Bulk

0.205 in (5.2 mm)

Supplemental

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; CSA; KC; PSE; UL

125 °C (257 °F)

Time Lag

0239007.MXP

Littelfuse

Electric Fuse

Inline/Holder

125 V

7 A

End Cap

305.758 J

-55 °C (-67 °F)

Nickel

10 kA

2 m

305.7

Bulk

0.205 in (5.2 mm)

Supplemental

125 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; CSA; KC; PSE; UL

125 °C (257 °F)

Time Lag

0312002.MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

2 A

End Cap

5.2 J

-55 °C (-67 °F)

Nickel

100 A

5 s

5.2

Tape And Reel

0.25 in (6.35 mm)

250 V

3AG

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; KC; PSE; UL

125 °C (257 °F)

Fast

0313.200MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

200 mA

End Cap

270 mJ

-60 °C (-76 °F)

Nickel

35 A

5 s

0.27

Bulk

0.25 in (6.35 mm)

Supplemental

250 V

3AG

1.25 x 0.25 in (31.75 x 6.35 mm)

1.25 in (31.75 mm)

CE; CSA; UL

125 °C (257 °F)

Time Lag

0314012.HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

12 A

End Cap

570 J

-55 °C (-67 °F)

Nickel

750 A

Rated Breaking Capacity at 125 VDC: 10000 A

570

Bulk

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; KC; PSE; UL

125 °C (257 °F)

Fast

0314015.HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

15 A

End Cap

292 J

-55 °C (-67 °F)

Nickel

750 A

Rated Breaking Capacity at 125 VDC: 10000 A

292

Bulk

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; KC; PSE; UL

125 °C (257 °F)

Fast

0326004.HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 V

4 A

End Cap

9.71 J

-55 °C (-67 °F)

Nickel

400 A

4 h

9.71

Bulk

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; PSE; UL

125 °C (257 °F)

Time Lag

0481.500V

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

500 mA

End Cap

490 mJ

-55 °C (-67 °F)

Tin

40 A

5 m

0.701 in (17.8 mm)

0.228 in (5.8 mm)

e3

125 V

Alarm; Indicator

0.772 in (19.6 mm)

CSA; UL

125 °C (257 °F)

Fast

0481.500VXL

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

500 mA

End Cap

490 mJ

-55 °C (-67 °F)

Tin

40 A

5 m

0.839 in (21.3 mm)

0.228 in (5.8 mm)

e3

125 V

Alarm; Indicator

0.772 in (19.6 mm)

CSA; UL

125 °C (257 °F)

Fast

0505020.MXP

Littelfuse

Electric Fuse

Inline/Holder

500 V

500 V

20 A

End Cap

140 J

-55 °C (-67 °F)

Nickel

30 kA

10 s

Rated Breaking Capacity at 500 VDC: 20000 A

140

Bulk

0.25 in (6.35 mm)

500 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

125 °C (257 °F)

Fast

0ADBC1600-BE

Bel Fuse

Electric Fuse

Inline/Holder

1 KV

1 KV

1.6 A

End Cap

768 mJ

-50 °C (-58 °F)

1.6 A

2 m

Bulk

0.25 in (6.35 mm)

1 KV

768 ms

0.236 x 1.26 in (6 x 32 mm)

1.291 in (32.8 mm)

CUL; UL

105 °C (221 °F)

Fast

0ADEC9200-BE

Bel Fuse

Electric Fuse

Inline/Holder

500 V

500 V

20 A

End Cap

120 J

-55 °C (-67 °F)

Silver

30 kA

10 s

Interrupting Current Max(DC): 20000 A, Pre Arcing Time: Open within 10 s at 300% Rated Current

Bulk

0.252 in (6.4 mm)

e4

500 V

0.236 x 1.26 in (6 x 32 mm)

1.252 in (31.8 mm)

CUL; UL

105 °C (221 °F)

Fast

0FLQ001.T

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

1 A

End Cap

Nickel

10 kA

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

0JTD1.25T

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

1.25 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.811 in (20.6 mm)

2.252 in (57.2 mm)

CSA; UL

Time Delay

0SPF001.TXS

Littelfuse

Electric Fuse

Inline/Holder

1 KV

1 A

End Cap

600 mJ

20 kA

4 m

Bulk

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL

0SPF015.T

Littelfuse

Electric Fuse

Inline/Holder

1 KV

15 A

End Cap

505 J

Nickel

20 kA

4 m

Bulk

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; TUV; UL

Fast

15SRC250

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

15 A

End Cap

0.8 in (20.32 mm)

2.97 in (75.43 mm)

17.5SDLSJ10

Eaton Corporation

Electric Fuse

Inline/Holder

17.5 KV

17.5 KV

10 A

End Cap

280 J

35.5 kA

2 in (50.8 mm)

2 x 11.496 in (50.8 x 292 mm)

11.496 in (292 mm)

DIN 43625; IEC; VDE

170M4489

Eaton Corporation

Electric Fuse

Inline/Holder

1.3 KV

200 A

End Cap

3.8 kJ

100 kA

2.913 in (74 mm)

2.087 in (53 mm)

Indicator

2.913 x 2.087 x 2.087 in (74 x 53 x 53 mm)

2.087 in (53 mm)

CE; IEC; UL

170M4491

Eaton Corporation

Electric Fuse

Inline/Holder

1.3 KV

315 A

End Cap

15 kJ

100 kA

2.913 in (74 mm)

2.087 in (53 mm)

Indicator

2.913 x 2.087 x 2.087 in (74 x 53 x 53 mm)

2.087 in (53 mm)

CE; IEC; UL

170M4494

Eaton Corporation

Electric Fuse

Inline/Holder

1.3 KV

450 A

End Cap

42 kJ

100 kA

2.913 in (74 mm)

2.087 in (53 mm)

Indicator

2.913 x 2.087 x 2.087 in (74 x 53 x 53 mm)

2.087 in (53 mm)

CE; IEC; UL

179120.2,5

Siba

Electric Fuse

Inline/Holder

250 V

2.5 A

End Cap

26 J

Nickel

35 A

Bulk

0.205 in (5.2 mm)

250 V

20 ms

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

SEMKO, UL, VDE

Time Lag

189140.0,5

Siba

Electric Fuse

Inline/Holder

500 V

400 V

500 mA

End Cap

350 mJ

Nickel

1.5 kA

Bulk

0.25 in (6.35 mm)

500 V

10 ms

0.248 x 1.26 in (6.3 x 32 mm)

1.252 in (31.8 mm)

UL

Time Lag

189140.10

Siba

Electric Fuse

Inline/Holder

500 V

400 V

10 A

End Cap

620 J

Nickel

1.5 kA

Bulk

0.25 in (6.35 mm)

500 V

20 ms

0.248 x 1.26 in (6.3 x 32 mm)

0.25 x 1.252 in (6.35 x 31.8 mm)

1.252 in (31.8 mm)

UL

Time Lag

189140.2,5

Siba

Electric Fuse

Inline/Holder

500 V

400 V

2.5 A

End Cap

19 J

1.5 kA

Bulk

0.25 in (6.35 mm)

500 V

20 ms

0.248 x 1.26 in (6.3 x 32 mm)

1.252 in (31.8 mm)

UL

Time Lag

189140.25

Siba

Electric Fuse

Inline/Holder

440 V

300 V

25 A

End Cap

5.6 kJ

Nickel

1.5 kA

Bulk

0.25 in (6.35 mm)

20 ms

0.248 x 1.26 in (6.3 x 32 mm)

0.25 x 1.252 in (6.35 x 31.8 mm)

1.252 in (31.8 mm)

Time Lag

31302.5

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 V

2.5 A

End Cap

130 J

-55 °C (-67 °F)

Tin/Lead

100 A

4 h

130

0.25 in (6.35 mm)

Supplemental

e0

250 V

81.1 mΩ

3AG

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; METI; PSE; UL

125 °C (257 °F)

Slow

313025

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

25 A

End Cap

16.5 kJ

-55 °C (-67 °F)

Tin/Lead

300 A

4 h

16500

0.25 in (6.35 mm)

Supplemental

e0

32 V

1.7 mΩ

3AG

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; PSE; UL

125 °C (257 °F)

Slow

35821000029

Littelfuse

Electric Fuse

Inline/Holder

500 V

10 A

End Cap

500 J

-25 °C (-13 °F)

Nickel

1.5 kA

Bulk

0.248 in (6.3 mm)

10 ms

0.248 x 1.26 in (6.3 x 32 mm)

1.26 in (32 mm)

CUL; UL

85 °C (185 °F)

Time Lag

3AB500-R

Bel Fuse

Electric Fuse

Inline/Holder

250 V

500 mA

End Cap

100 mJ

-55 °C (-67 °F)

Nickel

35 A

Bulk

0.25 in (6.35 mm)

250 V

0.236 x 1.26 in (6 x 32 mm)

0.25 x 1.252 in (6.35 x 31.8 mm)

1.252 in (31.8 mm)

CSA; CUL; UL

125 °C (257 °F)

Fast

5MF2-R

Bel Fuse

Electric Fuse

Inline/Holder

250 V

2 A

End Cap

4.4 J

-55 °C (-67 °F)

Nickel

200 A

5 s

Bulk

0.201 in (5.1 mm)

250 V

10 ms

0.197 x 0.787 in (5 x 20 mm)

0.201 x 0.787 in (5.1 x 20 mm)

0.787 in (20 mm)

CE; CSA; PSE; UL

125 °C (257 °F)

Fast

5ST1.25-R

Bel Fuse

Electric Fuse

Inline/Holder

250 V

1.25 A

End Cap

4.1 J

-55 °C (-67 °F)

Nickel

35 A

Bulk; Tape And Reel

0.201 in (5.1 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.201 x 0.787 in (5.1 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; SEMKO; UL; VDE

125 °C (257 °F)

Time Lag

5ST125-R

Bel Fuse

Electric Fuse

Inline/Holder

250 V

125 mA

End Cap

50 mJ

-55 °C (-67 °F)

Nickel

35 A

Bulk; Tape And Reel

0.201 in (5.1 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.201 x 0.787 in (5.1 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; SEMKO; UL; VDE

125 °C (257 °F)

Time Lag

5ST12.5-R

Bel Fuse

Electric Fuse

Inline/Holder

250 V

12.5 A

End Cap

490 J

-55 °C (-67 °F)

Nickel

35 A

Bulk; Tape And Reel

0.201 in (5.1 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.201 x 0.787 in (5.1 x 20 mm)

0.787 in (20 mm)

CE

125 °C (257 °F)

Time Lag

5ST8-R

Bel Fuse

Electric Fuse

Inline/Holder

250 V

8 A

End Cap

260 J

-55 °C (-67 °F)

Nickel

35 A

Bulk; Tape And Reel

0.201 in (5.1 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.201 x 0.787 in (5.1 x 20 mm)

0.787 in (20 mm)

CE; CSA; UL

125 °C (257 °F)

Time Lag

70065656,3A

Siba

Electric Fuse

Inline/Holder

250 V

250 V

6.3 A

End Cap

280 J

Box

0.25 in (6.35 mm)

15 ms

0.25 x 1.26 in (6.35 x 32 mm)

1.26 in (32 mm)

Slow

7012540.0,5

Siba

Electric Fuse

Inline/Holder

700 V

500 V

500 mA

End Cap

120 mJ

Nickel

50 kA

Rated Breaking Capacity at 500 VDC: 20000 A

Bulk

0.25 in (6.35 mm)

6 ms

0.25 x 1.252 in (6.35 x 31.8 mm)

1.252 in (31.8 mm)

CUL; UL

Very Fast

7017240.0,315

Siba

Electric Fuse

Inline/Holder

1 KV

1 KV

315 mA

End Cap

40 mJ

30 kA

Bulk

0.25 in (6.35 mm)

6 ms

0.248 x 1.26 in (6.3 x 32 mm)

1.252 in (31.8 mm)

UL

Very Fast

7022.0710

Schurter Ag

Electric Fuse

Inline/Holder

500 V

12.5 A

End Cap

26 J

-40 °C (-40 °F)

Tin/Tin Copper

10 kA

Bulk

0.25 in (6.35 mm)

e3/e2

3600 s

0.248 x 1.26 in (6.3 x 32 mm)

0.25 x 1.252 in (6.35 x 31.8 mm)

1.252 in (31.8 mm)

UL

85 °C (185 °F)

Super Fast

7022.0750

Schurter Ag

Electric Fuse

Inline/Holder

660 V

100 mA

End Cap

1.7 mJ

-40 °C (-40 °F)

Tin/Tin Copper

30 kA

Bulk

0.25 in (6.35 mm)

e3/e2

3600 s

0.248 x 0.906 in (6.3 x 23 mm)

0.25 x 1.252 in (6.35 x 31.8 mm)

1.252 in (31.8 mm)

UL

85 °C (185 °F)

Super Fast

7022.0760

Schurter Ag

Electric Fuse

Inline/Holder

660 V

125 mA

End Cap

3.3 mJ

-40 °C (-40 °F)

Tin/Tin Copper

30 kA

Bulk

0.25 in (6.35 mm)

e3/e2

3600 s

0.248 x 0.906 in (6.3 x 23 mm)

0.25 x 1.252 in (6.35 x 31.8 mm)

1.252 in (31.8 mm)

UL

85 °C (185 °F)

Super Fast

8020.5026.G

Schurter Ag

Electric Fuse

Inline/Holder

400 V

63 V

32 A

End Cap

8.75 kJ

-40 °C (-40 °F)

1.5 kA

Rated Breaking Capacity at 63 VDC: 20000 A

Bulk

0.25 in (6.35 mm)

10 ms

0.248 x 1.26 in (6.3 x 32 mm)

0.25 x 1.252 in (6.35 x 31.8 mm)

1.252 in (31.8 mm)

CUL; UL

85 °C (185 °F)

Time Lag

8020.5080

Schurter Ag

Electric Fuse

Inline/Holder

500 V

400 V

16 A

End Cap

760 J

-40 °C (-40 °F)

1.5 kA

760

Box

0.25 in (6.35 mm)

20 ms

0.248 x 1.26 in (6.3 x 32 mm)

0.25 x 1.252 in (6.35 x 31.8 mm)

1.252 in (31.8 mm)

CUL, UL

85 °C (185 °F)

Very Fast

8020.5080.G

Schurter Ag

Electric Fuse

Inline/Holder

500 V

400 V

16 A

End Cap

760 J

-40 °C (-40 °F)

1.5 kA

760

Bulk

0.25 in (6.35 mm)

20 ms

0.248 x 1.26 in (6.3 x 32 mm)

0.25 x 1.252 in (6.35 x 31.8 mm)

1.252 in (31.8 mm)

CUL, UL

85 °C (185 °F)

Very Fast

ABC-1-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 V

1 A

End Cap

431 mJ

Nickel

35 A

2 m

Pre Arcing Time: Open within 120 s at 200% Rated Current

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA; UL

Fast

AGU25

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

25 A

End Cap

0.406 in (10.3187 mm)

32 V

5AG

1.5 in (38.1 mm)

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.