End Cap Fuses 2,400+

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

022902.5MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

2.5 A

End Cap

50 J

-55 °C (-67 °F)

Tin

100 A

3 s

Rated Breaking Capacity at 125 VDC: 10000 A

Bulk

0.189 in (4.8 mm)

e3

2AG

0.177 x 0.57 in (4.5 x 14.48 mm)

0.587 in (14.9 mm)

CE; CSA; PSE; UL

125 °C (257 °F)

Time Lag

0233004.MXP

Littelfuse

Electric Fuse

Inline/Holder

125 V

4 A

End Cap

51.61 J

-55 °C (-67 °F)

Nickel

10 kA

600 ms

Bulk

0.205 in (5.2 mm)

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; CSA; KC; PSE; UL

125 °C (257 °F)

Medium

0313.400MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

400 mA

End Cap

1.35 J

-60 °C (-76 °F)

Nickel

35 A

5 s

1.35

Bulk

0.25 in (6.35 mm)

Supplemental

250 V

3AG

1.25 x 0.25 in (31.75 x 6.35 mm)

1.25 in (31.75 mm)

CE; CSA; UL

125 °C (257 °F)

Time Lag

0313.600VXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

600 mA

End Cap

4 J

-55 °C (-67 °F)

Nickel

35 A

313

Bulk

0.25 in (6.35 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; UL

125 °C (257 °F)

Time Lag

0313003.HXIDP

Littelfuse

Electric Fuse

Inline/Holder

250 V

3 A

End Cap

200 J

-55 °C (-67 °F)

Nickel

100 A

Bulk

0.25 in (6.35 mm)

Indicator

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; UL; KTL; PSE

125 °C (257 °F)

Time Lag

0313003.VXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

3 A

End Cap

200 J

-55 °C (-67 °F)

Nickel

100 A

Bulk

0.25 in (6.35 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; KTL; PSE; UL

125 °C (257 °F)

Time Lag

0313004.HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

4 A

End Cap

76.1 J

-55 °C (-67 °F)

Nickel

200 A

5 s

Pre Arcing Time: Open within 5 s at 200% Rated Current

76.1

Bulk

0.25 in (6.35 mm)

250 V

3AG

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; KTL; PSE; UL

125 °C (257 °F)

Time Lag

0313008.HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

8 A

End Cap

445 J

-55 °C (-67 °F)

Nickel

200 A

4 h

445

Bulk

0.25 in (6.35 mm)

Supplemental

250 V

3AG

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; KTL; PSE; UL

125 °C (257 °F)

Time Lag

0313008.MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

8 A

End Cap

701 J

-60 °C (-76 °F)

Nickel

200 A

5 s

445

Bulk

0.25 in (6.35 mm)

Supplemental

250 V

3AG

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; KC; PSE; UL

125 °C (257 °F)

Time Lag

0313015.MXP

Littelfuse

Electric Fuse

Inline/Holder

32 V

15 A

End Cap

2.65 kJ

-60 °C (-76 °F)

Nickel

300 A

5 s

1870

Bulk

0.25 in (6.35 mm)

Supplemental

32 V

3AG

1.25 x 0.25 in (31.75 x 6.35 mm)

1.25 in (31.75 mm)

UL

125 °C (257 °F)

Time Lag

031301.5MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

1.5 A

End Cap

38 J

-60 °C (-76 °F)

Nickel

100 A

5 s

38

Bulk

0.25 in (6.35 mm)

Supplemental

250 V

3AG

1.25 x 0.25 in (31.75 x 6.35 mm)

1.25 in (31.75 mm)

CE; CSA; PSE; UL

125 °C (257 °F)

Time Lag

0314006.HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

6 A

End Cap

45 J

-55 °C (-67 °F)

Nickel

750 A

Rated Breaking Capacity at 125 VDC: 10000 A

45

Bulk

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; KC; PSE; UL

125 °C (257 °F)

Fast

0314010.HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

10 A

End Cap

206 J

-55 °C (-67 °F)

Nickel

750 A

Rated Breaking Capacity at 125 VDC: 10000 A

206

Bulk

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; KC; PSE; UL

125 °C (257 °F)

Fast

0314010.MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

10 A

End Cap

206 J

-55 °C (-67 °F)

Nickel

750 A

Rated Breaking Capacity at 125 VDC: 10000 A

206

Bulk

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; KC; PSE; UL

125 °C (257 °F)

Fast

0326010.MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

10 A

End Cap

137 J

-55 °C (-67 °F)

Nickel

400 A

5 s

Rated Breaking Capacity at 125 VDC: 10000 A

137

Bulk

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; KC; PSE; UL

125 °C (257 °F)

Time Delay

0326.010MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

10 mA

End Cap

130 μJ

-55 °C (-67 °F)

Nickel

100 A

5 s

0.0014

Bulk

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE

125 °C (257 °F)

Time Delay

046601.5NR

Littelfuse

Electric Fuse

Surface Mount

63 V

63 V

1.5 A

End Cap

110.3 mJ

-55 °C (-67 °F)

Matte Tin Over Nickel

50 A

4 h

Rated Breaking Capacity at 63 VDC: 50 A

0.1103

Tape And Reel

0.125 in (3.18 mm)

0.06 in (1.52 mm)

Supplemental

e3

63 V

1206

0.125 x 0.06 x 0.023 in (3.18 x 1.52 x 0.58 mm)

0.023 in (0.58 mm)

CSA; UL

90 °C (194 °F)

Very Fast

0477010.MXP

Littelfuse

Electric Fuse

Inline/Holder

500 V

400 V

10 A

End Cap

509 J

-55 °C (-67 °F)

Nickel

100 A

10 ms

Rated Breaking Capacity at 400 VDC: 500 A

Bulk

0.205 in (5.2 mm)

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CUL; PSE; TUV; UL

125 °C (257 °F)

Time Lag

0481.500HXM

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

500 mA

End Cap

490 mJ

-55 °C (-67 °F)

40 A

5 m

0.701 in (17.8 mm)

0.228 in (5.8 mm)

125 V

Alarm; Indicator

0.772 in (19.6 mm)

CSA; UL

125 °C (257 °F)

Fast

0508.315MXP

Littelfuse

Electric Fuse

Inline/Holder

1 KV

1 KV

315 mA

End Cap

71 mJ

-55 °C (-67 °F)

10 kA

Bulk

0.248 in (6.3 mm)

0.248 x 1.26 in (6.3 x 32 mm)

1.26 in (32 mm)

CE; UL

125 °C (257 °F)

0508.500MXP

Littelfuse

Electric Fuse

Inline/Holder

1 KV

1 KV

500 mA

End Cap

259 mJ

-55 °C (-67 °F)

10 kA

Bulk

0.248 in (6.3 mm)

0.248 x 1.26 in (6.3 x 32 mm)

1.26 in (32 mm)

CE; UL

125 °C (257 °F)

0659C2500-12

Bel Fuse

Electric Fuse

Inline/Holder

250 V

2.5 A

End Cap

28.1 J

-55 °C (-67 °F)

Nickel

1.5 kA

Bulk

0.205 in (5.2 mm)

10 ms

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

CCC; CQC; CUL; PSE; UL; VDE

125 °C (257 °F)

Time Lag

0ADEC9100-BE

Bel Fuse

Electric Fuse

Inline/Holder

500 V

500 V

10 A

End Cap

100 J

-55 °C (-67 °F)

Silver

30 kA

10 s

Interrupting Current Max(DC): 20000 A, Pre Arcing Time: Open within 10 s at 300% Rated Current

Bulk

0.252 in (6.4 mm)

e4

500 V

0.236 x 1.26 in (6 x 32 mm)

1.252 in (31.8 mm)

CUL; UL

105 °C (221 °F)

Fast

0FLM001T

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

1 A

End Cap

10 kA

5 s

Pre Arcing Time: Open within 5 s at 200% Rated Current

Bulk

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE; CSA; QPL; UL

Time Delay

0FLM005T

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

5 A

End Cap

10 kA

12 s

Pre Arcing Time: Open within 12 s at 200% Rated Current

Bulk

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE; CSA; QPL; UL

Time Delay

0FLQ003.T

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

3 A

End Cap

Nickel

10 kA

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

0FLQ006.T

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

6 A

End Cap

Nickel

10 kA

0.406 in (10.31 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

0JTD004.TXID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

4 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.811 in (20.6 mm)

Indicator

2.252 in (57.2 mm)

CSA; UL

Time Delay

17037-G

Mersen S A

Electric Fuse

Inline/Holder

690 V

20 A

End Cap

Silver

80 kA

Box

0.563 in (14.3 mm)

e4

690 V

0.563 x 2.008 in (14.3 x 51 mm)

2.008 in (51 mm)

IEC; NFC; UNE

170M4488

Eaton Corporation

Electric Fuse

Inline/Holder

1.3 KV

160 A

End Cap

1.9 kJ

100 kA

2.913 in (74 mm)

2.087 in (53 mm)

Indicator

2.913 x 2.087 x 2.087 in (74 x 53 x 53 mm)

2.087 in (53 mm)

CE; IEC; UL

179020.2,5

Siba

Electric Fuse

Inline/Holder

250 V

2.5 A

End Cap

11 J

35 A

Bulk

0.205 in (5.2 mm)

250 V

20 ms

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

BEAB, SEMKO, UL, VDE

Very Fast

179120.2

Siba

Electric Fuse

Inline/Holder

250 V

2 A

End Cap

20 J

Nickel

35 A

Bulk

0.205 in (5.2 mm)

20 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

SEMKO, UL, VDE

Time Lag

189140.3,15

Siba

Electric Fuse

Inline/Holder

500 V

400 V

3.15 A

End Cap

37 J

Nickel

1.5 kA

Bulk

0.25 in (6.35 mm)

500 V

20 ms

0.248 x 1.26 in (6.3 x 32 mm)

1.252 in (31.8 mm)

UL

Time Lag

20111000001P

Littelfuse

Electric Fuse

Inline/Holder

250 V

1 A

End Cap

2 J

-25 °C (-13 °F)

80 A

5 ms

Pre Arcing Time: Open within 5 ms at 1000% Rated Current

Bulk

0.205 in (5.2 mm)

0.197 x 0.787 in (5 x 20 mm)

Indicator

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CUL; UL

70 °C (158 °F)

Medium Time Lag

20C14X51GI

Altech

Electric Fuse

Inline/Holder

690 V

20 A

End Cap

80 kA

Bulk

0.551 in (14 mm)

0.551 x 2.008 in (14 x 51 mm)

2.008 in (51 mm)

CE; IEC

Slow

313003P

Littelfuse

Electric Fuse

Inline/Holder

250 V

3 A

End Cap

200 J

Tin

100 A

0.25 in (6.35 mm)

e3

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; METI; PSE; UL

Slow

3AB12-R

Bel Fuse

Electric Fuse

Inline/Holder

250 V

12 A

End Cap

501 J

-55 °C (-67 °F)

Nickel

200 A

Bulk

0.25 in (6.35 mm)

250 V

0.236 x 1.26 in (6 x 32 mm)

0.25 x 1.252 in (6.35 x 31.8 mm)

1.252 in (31.8 mm)

CUL; PSE; UL

125 °C (257 °F)

Fast

3AG12-R

Bel Fuse

Electric Fuse

Inline/Holder

125 V

12 A

End Cap

501 J

-55 °C (-67 °F)

Nickel

10 kA

Pre-Arcing Time: Open within 5 s, at 200% Rated Current

Bulk; Tape And Reel

0.25 in (6.35 mm)

250 V

0.25 x 1.252 in (6.35 x 31.8 mm)

1.252 in (31.8 mm)

CE; CSA; PSE

125 °C (257 °F)

Fast

5019906.16

Siba

Electric Fuse

Inline/Holder

1 KV

1 KV

16 A

End Cap

30 J

30 kA

Bulk

0.394 in (10 mm)

1 ms

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

UL

5MF4-R

Bel Fuse

Electric Fuse

Inline/Holder

125 V

4 A

End Cap

22 J

-55 °C (-67 °F)

Nickel

10 kA

5 s

Bulk

0.201 in (5.1 mm)

125 V

10 ms

0.197 x 0.787 in (5 x 20 mm)

0.201 x 0.787 in (5.1 x 20 mm)

0.787 in (20 mm)

CE; CSA; PSE; UL

125 °C (257 °F)

Fast

6C/T

Altech

Electric Fuse

Inline/Holder

380 V

6 A

End Cap

Bulk

0.335 in (8.5 mm)

Indicator

1.26 in (32 mm)

CEI, IEC

Slow

7012540.10

Siba

Electric Fuse

Inline/Holder

600 V

10 A

End Cap

12 J

Nickel

50 kA

Bulk

0.25 in (6.35 mm)

1 ms

0.25 x 1.252 in (6.35 x 31.8 mm)

1.252 in (31.8 mm)

CUL; UL

Very Fast

7017240.0,5

Siba

Electric Fuse

Inline/Holder

1 KV

1 KV

500 mA

End Cap

120 mJ

30 kA

Bulk

0.25 in (6.35 mm)

6 ms

0.248 x 1.26 in (6.3 x 32 mm)

1.252 in (31.8 mm)

UL

Very Fast

8020.0603

Schurter Ag

Electric Fuse

Inline/Holder

250 V

12 A

End Cap

72 J

-40 °C (-40 °F)

500 A

Box

0.25 in (6.35 mm)

5 s

3AB

0.25 x 1.252 in (6.35 x 31.8 mm)

1.252 in (31.8 mm)

CUL; UL

85 °C (185 °F)

Time Lag

8020.0603.G

Schurter Ag

Electric Fuse

Inline/Holder

250 V

12 A

End Cap

72 J

-40 °C (-40 °F)

500 A

Bulk

0.25 in (6.35 mm)

5 s

3AB

0.25 x 1.252 in (6.35 x 31.8 mm)

1.252 in (31.8 mm)

CUL; UL

85 °C (185 °F)

Time Lag

8020.0603.H

Schurter Ag

Electric Fuse

Inline/Holder

250 V

100 V

12 A

End Cap

788 J

-40 °C (-40 °F)

Nickel

500 A

Bulk

0.25 in (6.35 mm)

5 s

3AG

1.252 in (31.8 mm)

CUL; UL

85 °C (185 °F)

Time Lag

8020.0603G

Schurter Ag

Electric Fuse

Inline/Holder

250 V

12 A

End Cap

72 J

-40 °C (-40 °F)

500 A

Bulk

0.25 in (6.35 mm)

5 s

3AB

0.25 x 1.252 in (6.35 x 31.8 mm)

1.252 in (31.8 mm)

CUL; UL

85 °C (185 °F)

Time Lag

ABC-1/2-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 V

500 mA

End Cap

39 mJ

Nickel

35 A

4 h

Rated Breaking Capacity at 125 VDC: 10000 A

0.25 in (6.35 mm)

250 V

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA; UL

Fast

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.