Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Nominal Joule Integral | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Pre Arcing Rating (A2/s) | Packing Method | Body Length/Diameter | Body Width | Fuse Class | JESD-609 Code | Rated Voltage | Resistance | Minimum Pre Arcing Time | Fuse Size | Built-in Features | Dimensions | Body Height | Reference Standard | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Schurter Ag |
Electric Fuse |
Inline/Holder |
250 V |
2 A |
End Cap |
16 J |
-55 °C (-67 °F) |
Nickel |
35 A |
Box |
0.205 in (5.2 mm) |
20 ms |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CUL; METI; UL; VDE |
125 °C (257 °F) |
Time Lag |
||||||||||||
|
Schurter Ag |
Electric Fuse |
Inline/Holder |
250 V |
400 mA |
End Cap |
768 mJ |
-55 °C (-67 °F) |
Gold |
35 A |
Bulk |
0.205 in (5.2 mm) |
e4 |
20 ms |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC, CUL, UL, VDE |
125 °C (257 °F) |
Time Lag |
|||||||||||
|
Schurter Ag |
Electric Fuse |
Inline/Holder |
250 V |
2 A |
End Cap |
124 J |
-55 °C (-67 °F) |
Gold |
35 A |
Bulk |
0.205 in (5.2 mm) |
e4 |
150 ms |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CUL; UL |
125 °C (257 °F) |
Super Time Lag |
|||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
1 A |
End Cap |
19.2 J |
-55 °C (-67 °F) |
Nickel |
35 A |
20 ms |
19.2 |
Bulk |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.228 x 0.886 in (5.8 x 22.5 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; IEC; PSE; SEV; SEMKO; UL; VDE |
125 °C (257 °F) |
Time Lag |
||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
50 mA |
End Cap |
490 μJ |
-55 °C (-67 °F) |
Nickel |
35 A |
3 ms |
Bulk |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; IEC; KC; SEMKO; UL; VDE |
125 °C (257 °F) |
Very Fast |
|||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
250 mA |
End Cap |
40 mJ |
-55 °C (-67 °F) |
Nickel |
35 A |
10 ms |
Bulk |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; SEMKO; UL; VDE |
125 °C (257 °F) |
Very Fast |
|||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
80 mA |
End Cap |
1.32 mJ |
-55 °C (-67 °F) |
35 A |
3 ms |
Pre Arcing Time: Open within 3 ms at 400% Rated Current |
Bulk |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; CUL; KC; SEMKO; UL; VDE |
125 °C (257 °F) |
Fast |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
80 mA |
End Cap |
1.32 mJ |
-55 °C (-67 °F) |
35 A |
3 ms |
Pre Arcing Time: Open within 3 ms at 400% Rated Current |
Bulk |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; CUL; KC; SEMKO; UL; VDE |
125 °C (257 °F) |
Fast |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
8 A |
End Cap |
198.16 J |
-55 °C (-67 °F) |
Nickel |
80 A |
10 ms |
198.16 |
Bulk |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CE; IEC; KC; PSE; VDE; UL |
125 °C (257 °F) |
Very Fast |
||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
8 A |
End Cap |
198.16 J |
-55 °C (-67 °F) |
Nickel |
80 A |
10 ms |
Bulk |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CE; IEC; KC; PSE; VDE; UL |
125 °C (257 °F) |
Very Fast |
|||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
15 A |
End Cap |
607.135 J |
-55 °C (-67 °F) |
Nickel |
150 A |
10 ms |
Bulk |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CE; IEC; PSE; VDE |
125 °C (257 °F) |
Very Fast |
|||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
1 A |
End Cap |
6.73 J |
-55 °C (-67 °F) |
Nickel |
35 A |
20 ms |
Pre Arcing Time: Open within 20 ms at 1000% Rated Current |
6.73 |
Bulk |
0.205 in (5.2 mm) |
Supplemental |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; IEC; KC; PSE; SEMKO; UL; VDE |
125 °C (257 °F) |
Time Lag |
||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
1.6 A |
End Cap |
23.35 J |
-55 °C (-67 °F) |
Nickel |
35 A |
20 ms |
23.35 |
Bulk |
0.205 in (5.2 mm) |
Supplemental |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
BSI; CCC; CE; CSA; IEC; KC; PSE; SEMKO; UL; VDE |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
3.5 A |
End Cap |
6.7 J |
-55 °C (-67 °F) |
Tin |
100 A |
1 s |
Rated Breaking Capacity at 125 VDC: 10000 A |
6.7 |
Bulk |
0.189 in (4.8 mm) |
e3 |
250 V |
2AG |
0.177 x 0.57 in (4.5 x 14.48 mm) |
0.587 in (14.9 mm) |
CE, CSA, PSE, UL |
125 °C (257 °F) |
Fast |
|||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
125 V |
6 A |
End Cap |
131.455 J |
-55 °C (-67 °F) |
Matte Tin |
10 kA |
Bulk |
0.205 in (5.2 mm) |
e3 |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CE; CSA; KC; PSE; UL |
125 °C (257 °F) |
Medium |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
500 mA |
End Cap |
1.985 J |
-55 °C (-67 °F) |
Nickel |
35 A |
4 h |
1.985 |
Bulk |
0.205 in (5.2 mm) |
Supplemental |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CE; CSA; KC; UL |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
500 mA |
End Cap |
1.985 J |
-55 °C (-67 °F) |
Tin |
35 A |
2 m |
1.985 |
Bulk |
0.205 in (5.2 mm) |
Supplemental |
e3 |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CE; CSA; KC; UL |
125 °C (257 °F) |
Time Lag |
||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
250 mA |
End Cap |
385 mJ |
-60 °C (-76 °F) |
Nickel |
35 A |
5 s |
0.385 |
Bulk |
0.25 in (6.35 mm) |
Supplemental |
250 V |
3AG |
1.25 x 0.25 in (31.75 x 6.35 mm) |
1.25 in (31.75 mm) |
CE; CSA; UL |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
20 A |
End Cap |
10 kA |
Pre Arcing Time: Open within 12 s at 200% Rated Current |
0.406 in (10.31 mm) |
250 V |
Midget |
0.406 x 1.5 in (10.31 x 38.1 mm) |
1.5 in (38.1 mm) |
CSA; QPL; UL |
Slow |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
20 A |
End Cap |
10 kA |
12 s |
Pre Arcing Time: Open within 12 s at 200% Rated Current |
Bulk |
0.406 in (10.31 mm) |
0.394 x 1.496 in (10 x 38 mm) |
1.5 in (38.1 mm) |
CE; CSA; QPL; UL |
Time Delay |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
500 V |
100 mA |
End Cap |
100 kA |
Rated Breaking Capacity at 500 VDC: 50000 A |
0.406 in (10.31 mm) |
0.394 x 1.496 in (10 x 38 mm) |
1.5 in (38.1 mm) |
CSA; UL |
Fast |
|||||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
15.5 KV |
15.5 KV |
20 A |
End Cap |
63 kA |
2.992 in (76 mm) |
23.898 in (607 mm) |
ANSI |
|||||||||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
15.5 KV |
15.5 KV |
25 A |
End Cap |
63 kA |
2.992 in (76 mm) |
23.898 in (607 mm) |
ANSI |
|||||||||||||||||||||
|
Siba |
Electric Fuse |
Inline/Holder |
500 V |
400 V |
5 A |
End Cap |
80 J |
Nickel |
1.5 kA |
Bulk |
0.25 in (6.35 mm) |
500 V |
20 ms |
0.248 x 1.26 in (6.3 x 32 mm) |
1.252 in (31.8 mm) |
UL |
Time Lag |
|||||||||||||
|
Siba |
Electric Fuse |
Inline/Holder |
500 V |
400 V |
8 A |
End Cap |
370 J |
Nickel |
1.5 kA |
Bulk |
0.25 in (6.35 mm) |
500 V |
20 ms |
0.248 x 1.26 in (6.3 x 32 mm) |
1.252 in (31.8 mm) |
UL |
Time Lag |
|||||||||||||
Siba |
Electric Fuse |
Inline/Holder |
690 V |
8 A |
End Cap |
4 J |
200 kA |
Bulk |
0.866 in (22 mm) |
0.866 x 2.283 in (22 x 58 mm) |
2.283 in (58 mm) |
DIN, EN, IEC, UL, VDE |
Very Fast |
||||||||||||||||||
|
Bel Fuse |
Electric Fuse |
Inline/Holder |
250 V |
10 A |
End Cap |
439 J |
-55 °C (-67 °F) |
Nickel |
35 A |
Bulk; Tape And Reel |
0.201 in (5.1 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.201 x 0.787 in (5.1 x 20 mm) |
0.787 in (20 mm) |
CE; CSA; UL |
125 °C (257 °F) |
Time Lag |
||||||||||||
|
Schurter Ag |
Electric Fuse |
Inline/Holder |
500 V |
10 A |
End Cap |
30 J |
-40 °C (-40 °F) |
Tin/Tin Copper |
10 kA |
Bulk |
0.25 in (6.35 mm) |
e3/e2 |
3600 s |
0.248 x 1.26 in (6.3 x 32 mm) |
0.25 x 1.252 in (6.35 x 31.8 mm) |
1.252 in (31.8 mm) |
UL |
85 °C (185 °F) |
Super Fast |
|||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
32 V |
1 A |
End Cap |
0.25 in (6.35 mm) |
32 V |
1AG |
0.625 in (15.875 mm) |
||||||||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
125 V |
1 A |
End Cap |
10 kA |
0.252 in (6.4 mm) |
250 V |
0.252 x 0.626 in (6.4 x 15.9 mm) |
0.626 in (15.9 mm) |
CE; UL |
Fast |
|||||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
500 V |
15 A |
End Cap |
10 kA |
0.394 in (10 mm) |
500 V |
0.394 x 1.496 in (10 x 38 mm) |
1.496 in (38 mm) |
CSA; UL |
Time Delay |
||||||||||||||||||
Mersen S A |
Electric Fuse |
Inline/Holder |
500 V |
800 mA |
End Cap |
10 kA |
0.394 in (10 mm) |
500 V |
0.394 x 1.496 in (10 x 38 mm) |
1.496 in (38 mm) |
CSA; UL |
Time Delay |
|||||||||||||||||||
Eaton Corporation |
Electric Fuse |
100 mA |
End Cap |
10 kA |
0.41 in (10.41 mm) |
600 V |
0.41 x 1.38 in (10.41 x 35.05 mm) |
1.38 in (35.05 mm) |
CE, CSA, UL |
Fast |
|||||||||||||||||||||
Eaton Corporation |
Electric Fuse |
250 mA |
End Cap |
10 kA |
0.41 in (10.41 mm) |
600 V |
0.41 x 1.38 in (10.41 x 35.05 mm) |
1.38 in (35.05 mm) |
CE, CSA, UL |
Fast |
|||||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
30 A |
End Cap |
1.097 kJ |
Nickel |
1.5 kA |
2 m |
Rated Breaking Capacity at 125 VDC: 10000 A |
Box |
0.25 in (6.35 mm) |
3AB |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CSA, UL |
Time Delay |
||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
2 A |
End Cap |
9.6 J |
-55 °C (-67 °F) |
Nickel |
1.5 kA |
9.6 |
Bulk |
0.205 in (5.2 mm) |
250 V |
10 ms |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
BSI, CCC, CSA, CUL, IMQ, KC, PSE, SEMKO, UL, VDE |
125 °C (257 °F) |
Time Delay |
||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
3 A |
End Cap |
Nickel |
100 A |
Pre Arcing Time: OPEN within 2 MIN at 200% RATED CURRENT |
Box |
0.25 in (6.35 mm) |
250 V |
0.248 x 1 in (6.3 x 25.4 mm) |
0.25 x 1.042 in (6.35 x 26.47 mm) |
1 in (25.4 mm) |
CUL |
Fast |
|||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
187.5 mA |
End Cap |
Nickel |
35 A |
Pre Arcing Time: Open within 5 s at 200% Rated Current |
Box |
0.25 in (6.35 mm) |
250 V |
0.248 x 1 in (6.3 x 25.4 mm) |
0.25 x 1.042 in (6.35 x 26.47 mm) |
1 in (25.4 mm) |
CUL |
Fast |
|||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
375 mA |
End Cap |
Nickel |
35 A |
Pre Arcing Time: Open within 5 s at 200% Rated Current |
Box |
0.25 in (6.35 mm) |
250 V |
0.248 x 1 in (6.3 x 25.4 mm) |
0.25 x 1.042 in (6.35 x 26.47 mm) |
1 in (25.4 mm) |
CUL |
Fast |
|||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
2 A |
End Cap |
3.1 J |
Nickel |
100 A |
Pre Arcing Time: OPEN within 2 MIN at 200% RATED CURRENT |
Box |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CSA; PSE; UL |
Fast |
|||||||||||||
|
Cooper Industries |
Electric Fuse |
Inline/Holder |
250 V |
2 A |
End Cap |
9.6 J |
1.5 kA |
9.6 |
Box |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
BSI; CCC/CQC; CSA; IEC; IMQ; KC; PSE/JET; SEMKO; UL; VDE |
Time Delay |
||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
80 A |
End Cap |
120 kA |
C22 |
0.866 in (22 mm) |
0.866 x 2.283 in (22 x 58 mm) |
2.283 in (58 mm) |
IEC |
||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
80 A |
End Cap |
120 kA |
C22 |
0.866 in (22 mm) |
0.866 x 2.283 in (22 x 58 mm) |
2.283 in (58 mm) |
IEC |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
800 mA |
End Cap |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
0.406 in (10.3 mm) |
600 V |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
500 V |
30 A |
End Cap |
1.79 kJ |
Nickel |
200 kA |
Rated Breaking Capacity at 500 VDC: 20000 A |
Bulk |
0.406 in (10.3 mm) |
600 V |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
250 V |
50 A |
End Cap |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
0.85 in (21.6 mm) |
600 V |
1.882 in (47.8 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
2.25 A |
End Cap |
351 J |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
0.406 in (10.3 mm) |
600 V |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; UL |
Time Delay |
||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
30 A |
End Cap |
200 kA |
Rated Breaking Capacity at 125 VDC: 20000 A |
Bulk |
0.563 in (14.3 mm) |
2 in (50.8 mm) |
CSA; UL |
Time Delay |
A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.
Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.
In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.