End Cap Fuses 2,400+

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

012301

Legrand

Electric Fuse

Inline/Holder

400 V

1 A

End Cap

-25 °C (-13 °F)

20 kA

Bulk

0.335 in (8.5 mm)

0.315 x 1.26 in (8 x 32 mm)

1.24 in (31.5 mm)

EN; IEC

40 °C (104 °F)

012304

Legrand

Electric Fuse

Inline/Holder

400 V

4 A

End Cap

-25 °C (-13 °F)

20 kA

Bulk

0.335 in (8.5 mm)

0.315 x 1.26 in (8 x 32 mm)

1.24 in (31.5 mm)

EN; IEC

40 °C (104 °F)

012306

Legrand

Electric Fuse

Inline/Holder

400 V

6 A

End Cap

-25 °C (-13 °F)

20 kA

Bulk

0.335 in (8.5 mm)

0.315 x 1.26 in (8 x 32 mm)

1.24 in (31.5 mm)

EN; IEC

40 °C (104 °F)

012316

Legrand

Electric Fuse

Inline/Holder

400 V

16 A

End Cap

-25 °C (-13 °F)

20 kA

Bulk

0.335 in (8.5 mm)

0.315 x 1.26 in (8 x 32 mm)

1.24 in (31.5 mm)

EN; IEC

40 °C (104 °F)

0313.010MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

10 mA

End Cap

121 μJ

-60 °C (-76 °F)

Nickel

35 A

5 s

0.0001

Bulk

0.25 in (6.35 mm)

Supplemental

250 V

3AG

1.25 x 0.25 in (31.75 x 6.35 mm)

1.25 in (31.75 mm)

CE; CSA; UL

125 °C (257 °F)

Time Lag

0313001.HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

1 A

End Cap

14 J

-55 °C (-67 °F)

Nickel

35 A

4 h

14

Bulk

0.25 in (6.35 mm)

Supplemental

250 V

3AG

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; PSE; UL

125 °C (257 °F)

Time Lag

0313010.MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

10 A

End Cap

1.285 kJ

-60 °C (-76 °F)

Nickel

200 A

5 s

760

Bulk

0.25 in (6.35 mm)

Supplemental

250 V

3AG

1.25 x 0.25 in (31.75 x 6.35 mm)

1.25 in (31.75 mm)

CE; CSA; PSE; UL

125 °C (257 °F)

Time Lag

326.010P

Littelfuse

Electric Fuse

Inline/Holder

250 V

10 mA

End Cap

1.48 mJ

Tin

100 A

326

0.25 in (6.35 mm)

e3

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; PSE; UL

Slow

326010P

Littelfuse

Electric Fuse

Inline/Holder

250 V

10 A

End Cap

137 J

-65 °C (-85 °F)

Nickel

400 A

4 h

137

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; PSE; UL

125 °C (257 °F)

Slow

BK-GMC-2-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

2 A

End Cap

8.9 J

Nickel

100 A

Pre Arcing Time: OPEN within 2 MIN at 200% RATED CURRENT

Box

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CSA; KC; MITI; UL

Time Delay

BK/AGC-12-R

Eaton Corporation

Electric Fuse

Inline/Holder

32 V

12 A

End Cap

Nickel

1 kA

Box

0.25 in (6.35 mm)

0.248 x 1.26 in (6.3 x 32 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA; UL

Fast

BK/AGC-1/2-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

500 mA

End Cap

269 mJ

Nickel

35 A

Box

0.25 in (6.35 mm)

32 V

0.248 x 1.26 in (6.3 x 32 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA; UL

Fast

BK/GMA-10-R

Eaton Corporation

Electric Fuse

Inline/Holder

125 V

10 A

End Cap

280 J

Nickel

200 A

Pre Arcing Time: OPEN within 2 MIN at 200% RATED CURRENT

Box

0.205 in (5.2 mm)

125 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

PSE; UL

Fast

BK/GMC-2-R

Cooper Industries

Electric Fuse

Inline/Holder

250 V

2 A

End Cap

8.9 J

Nickel

100 A

GMC

Box

0.205 in (5.2 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CSA; MITI; UL

Medium Time Delay

BK/S504-2.5A

Cooper Industries

Electric Fuse

Inline/Holder

250 V

2.5 A

End Cap

36 J

35 A

S504

Bulk

0.205 in (5.2 mm)

20 ms

0.205 x 0.394 in (5.2 x 10 mm)

0.394 in (10 mm)

BSI; IMQ; SEMKO; UL; UR; VDE

Time Delay

BK1/S506-315-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

315 mA

End Cap

621 mJ

Nickel

35 A

0.621

Bag

0.205 in (5.2 mm)

250 V

20 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

BSI; CCC; CSA; IMQ; SEMKO; UL; VDE

Time Delay

BK1/S506-3.15-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

3.15 A

End Cap

96.4 J

Nickel

35 A

96.4

Bag

0.205 in (5.2 mm)

250 V

20 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

BSI; CCC; CSA; IMQ; PSE; SEMKO; UL; VDE

Time Delay

FNQ-R-3-2/10

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

3.2 A

End Cap

Nickel

200 kA

Box

0.406 in (10.3 mm)

CC

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

FRN-R-1/2

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 V

500 mA

End Cap

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

Box

0.563 in (14.3 mm)

RK5

250 V

0.563 x 2 in (14.3 x 50.8 mm)

2 in (50.8 mm)

CE; CSA; UL

Time Delay

FRN-R-12

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 V

12 A

End Cap

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

Box

0.563 in (14.3 mm)

0.563 x 2 in (14.3 x 50.8 mm)

2 in (50.8 mm)

CE; CSA; UL

Time Delay

FWP-80A22F

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

500 V

80 A

End Cap

600 J

200 kA

Rated Breaking Capacity at 500 VDC: 50000 A

Box

0.874 in (22.2 mm)

0.874 x 2.283 in (22.2 x 58 mm)

2.283 in (58 mm)

IEC; UL

JJS-10

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

10 A

End Cap

200 kA

0.563 in (14.3 mm)

0.563 x 1.5 in (14.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Very Fast

KLDR.300TXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

300 mA

End Cap

11.1 mJ

Nickel

200 kA

12 s

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

KTK-30

Eaton Corporation

Electric Fuse

30 A

End Cap

100 kA

0.406 in (10.3 mm)

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CSA, UL

Fast

S500-40-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

40 mA

End Cap

110 μJ

Silver

35 A

0.205 in (5.2 mm)

e4

250 V

3600 s

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

Fast

SDL.800

Conquer Electronics

Electric Fuse

Inline/Holder

250 V

800 mA

End Cap

2.24 J

-55 °C (-67 °F)

35 A

Box

0.181 in (4.6 mm)

3 s

0.181 x 0.571 in (4.6 x 14.5 mm)

0.571 in (14.5 mm)

CSA; UL

125 °C (257 °F)

Time Lag

0001.2501

Schurter Ag

Electric Fuse

Inline/Holder

250 V

300 V

500 mA

End Cap

500 mJ

-55 °C (-67 °F)

Nickel

1.5 kA

Rated Breaking Capacity at 300 VDC: 1500 A

0.5

Box

0.205 in (5.2 mm)

5 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CUL; UL; VDE

125 °C (257 °F)

Time Lag

0215002.HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

2 A

End Cap

11.68 J

-55 °C (-67 °F)

Nickel

1.5 kA

10 ms

11.68

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; KC; PSE; SEMKO; SEV; UL; VDE

125 °C (257 °F)

Time Lag

0225005.HXUP

Littelfuse

Electric Fuse

5 A

End Cap

-55 °C (-67 °F)

Tin

100 A

4 h

17

0.189 in (4.8 mm)

e3

250 V

2AG

0.189 x 0.587 in (4.8 x 14.9 mm)

0.587 in (14.9 mm)

CE, CSA, UL

125 °C (257 °F)

Fast

031303.2HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

3.2 A

End Cap

209 J

-55 °C (-67 °F)

Nickel

100 A

4 h

209

Bulk

0.25 in (6.35 mm)

Supplemental

250 V

3AG

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; KTL; PSE; UL

125 °C (257 °F)

Time Lag

0326005.MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

5 A

End Cap

25 J

-55 °C (-67 °F)

Nickel

400 A

5 s

Rated Breaking Capacity at 125 VDC: 10000 A

25

Bulk

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; PSE; UL

125 °C (257 °F)

Time Delay

0SPF001.T

Littelfuse

Electric Fuse

Inline/Holder

1 KV

1 A

End Cap

600 mJ

20 kA

4 m

Bulk

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; TUV; UL

Fast

179120.5

Siba

Electric Fuse

Inline/Holder

250 V

5 A

End Cap

130 J

Nickel

50 A

Bulk

0.205 in (5.2 mm)

20 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

SEMKO, UL, VDE

Time Lag

5019906.10

Siba

Electric Fuse

Inline/Holder

1 KV

1 KV

10 A

End Cap

10 J

30 kA

Bulk

0.394 in (10 mm)

1 ms

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

UL

63D33Q

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

63 A

End Cap

26.5 kJ

50 kA

Bulk

1.063 in (27 mm)

DIII

1.969 in (50 mm)

DIN 49515; IEC60269

Fast

7012540.4

Siba

Electric Fuse

Inline/Holder

600 V

500 V

4 A

End Cap

5 J

Nickel

50 kA

Rated Breaking Capacity at 500 VDC: 20000 A

Bulk

0.25 in (6.35 mm)

1 ms

0.25 x 1.252 in (6.35 x 31.8 mm)

1.252 in (31.8 mm)

CUL; UL

Very Fast

ABC-1-1/2-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 V

1.5 A

End Cap

1.163 J

Nickel

100 A

2 m

Pre Arcing Time: Open within 120 s at 200% Rated Current

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA; UL

Fast

BK/GMA-1-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

1 A

End Cap

480 mJ

Nickel

35 A

Pre Arcing Time: OPEN within 2 MIN at 200% RATED CURRENT

0.48

Box

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CSA; PSE; UL

Fast

BK/GMA-500-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

500 mA

End Cap

150 mJ

Silver

35 A

Pre Arcing Time: OPEN within 2 MIN at 200% RATED CURRENT

Box

0.205 in (5.2 mm)

e4

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CSA; UL

Fast

C22M63

Eaton Corporation

Electric Fuse

Inline/Holder

690 V

690 V

63 A

End Cap

80 kA

C22

0.866 in (22 mm)

0.866 x 2.283 in (22 x 58 mm)

2.283 in (58 mm)

IEC

CCMR001.TXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

1 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

CCMR004.TXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

4 A

End Cap

1.87 kJ

Nickel

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

CCMR010.TXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

10 A

End Cap

1.25 kJ

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

E1014580

Mersen S A

Electric Fuse

Inline/Holder

700 V

500 V

20 A

End Cap

39 J

160 kA

Bulk

0.406 in (10.3 mm)

GR

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

CCC, CE, CSA, IEC, UL

Fast

FNQ-15/100

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

150 mA

End Cap

Nickel

10 kA

Bulk

0.41 in (10.41 mm)

CC

500 V

Midget

0.41 x 1.5 in (10.41 x 38.1 mm)

1.5 in (38.1 mm)

CE, CSA, UL

Time Delay

FNQ-R-1-6/10

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

1.6 A

End Cap

Nickel

200 kA

Box

0.406 in (10.3 mm)

CC

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

FNQ-R-6

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

6 A

End Cap

Nickel

200 kA

Box

0.406 in (10.3 mm)

CC

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

FWP-63A22FI

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

500 V

63 A

End Cap

280 J

200 kA

Rated Breaking Capacity at 500 VDC: 50000 A

0.874 in (22.2 mm)

Indicator

0.874 x 2.283 in (22.2 x 58 mm)

2.283 in (58 mm)

CE; IEC; UL

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.