Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Nominal Joule Integral | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Pre Arcing Rating (A2/s) | Packing Method | Body Length/Diameter | Body Width | Fuse Class | JESD-609 Code | Rated Voltage | Resistance | Minimum Pre Arcing Time | Fuse Size | Built-in Features | Dimensions | Body Height | Reference Standard | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Bourns |
Electric Fuse |
Inline/Holder |
1 KV |
15 A |
End Cap |
365 J |
-55 °C (-67 °F) |
20 kA |
4 m |
Bulk |
0.406 in (10.3 mm) |
5AG |
1.496 in (38 mm) |
CUL; UL |
125 °C (257 °F) |
|||||||||||||||
|
Bourns |
Electric Fuse |
Inline/Holder |
1 KV |
20 A |
End Cap |
804.3 J |
-55 °C (-67 °F) |
20 kA |
4 m |
Bulk |
0.406 in (10.3 mm) |
5AG |
1.496 in (38 mm) |
CUL; UL |
125 °C (257 °F) |
|||||||||||||||
|
Bourns |
Electric Fuse |
Inline/Holder |
1 KV |
25 A |
End Cap |
1.202 kJ |
-55 °C (-67 °F) |
20 kA |
4 m |
Bulk |
0.406 in (10.3 mm) |
5AG |
1.496 in (38 mm) |
CUL; UL |
125 °C (257 °F) |
|||||||||||||||
|
Bourns |
Electric Fuse |
Inline/Holder |
1 KV |
30 A |
End Cap |
2.229 kJ |
-55 °C (-67 °F) |
20 kA |
4 m |
Bulk |
0.406 in (10.3 mm) |
5AG |
1.496 in (38 mm) |
CUL; UL |
125 °C (257 °F) |
|||||||||||||||
|
Schurter Ag |
Electric Fuse |
Inline/Holder |
250 V |
2.5 A |
End Cap |
21.9 J |
-55 °C (-67 °F) |
Nickel |
35 A |
Box |
0.205 in (5.2 mm) |
20 ms |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CUL; METI; UL; VDE |
125 °C (257 °F) |
Time Lag |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
250 V |
8 A |
End Cap |
209.88 J |
-55 °C (-67 °F) |
Matte Tin |
1.5 kA |
10 ms |
Pre Arcing Time: Open within 10 ms at 1000% Rated Current |
209.88 |
Bulk |
0.205 in (5.2 mm) |
e3 |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CE; CSA; IEC; KC; PSE; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Time Lag |
|||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
250 V |
8 A |
End Cap |
209.88 J |
-55 °C (-67 °F) |
Matte Tin |
1.5 kA |
10 ms |
Pre Arcing Time: Open within 10 ms at 1000% Rated Current |
209.88 |
Bulk |
0.205 in (5.2 mm) |
e3 |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CE; CSA; IEC; KC; PSE; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Time Lag |
|||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
1.6 A |
End Cap |
1.005 J |
-55 °C (-67 °F) |
Nickel |
1.5 kA |
20 ms |
1.005 |
Bulk |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; IEC; KC; PSE; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Fast |
||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
16 A |
End Cap |
462.5 J |
-55 °C (-67 °F) |
Tin |
750 A |
462.5 |
Bulk |
0.205 in (5.2 mm) |
e3 |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CE; CSA; IEC; PSE; SEMKO; UL |
125 °C (257 °F) |
Fast |
||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
2 A |
End Cap |
77 J |
-55 °C (-67 °F) |
Nickel |
100 A |
4 h |
77 |
Bulk |
0.25 in (6.35 mm) |
Supplemental |
250 V |
3AG |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CE; CSA; PSE; UL |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
300 V |
25 A |
End Cap |
10 kA |
0.406 in (10.31 mm) |
0.394 x 1.496 in (10 x 38 mm) |
0.406 x 1.5 in (10.31 x 38.1 mm) |
1.5 in (38.1 mm) |
CSA; UL |
Time Delay |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
300 V |
2.5 A |
End Cap |
10 kA |
0.406 in (10.31 mm) |
500 V |
0.394 x 1.496 in (10 x 38 mm) |
1.5 in (38.1 mm) |
CSA; UL |
Time Delay |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
500 V |
3 A |
End Cap |
100 kA |
Rated Breaking Capacity at 500 VDC: 50000 A |
0.406 in (10.31 mm) |
0.394 x 1.496 in (10 x 38 mm) |
1.5 in (38.1 mm) |
CSA; UL |
Fast |
|||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
700 V |
400 V |
40 A |
End Cap |
200 kA |
Rated Breaking Capacity at 400 VDC: 100000 A |
1.063 in (27 mm) |
Indicator |
1.063 x 2.362 in (27 x 60 mm) |
2.362 in (60 mm) |
Time Delay |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
3 A |
End Cap |
Nickel |
10 kA |
Bulk |
0.406 in (10.3 mm) |
CC |
500 V |
Midget |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE, CSA, UL |
Time Delay |
|||||||||||||
|
Eaton Corporation |
Electric Fuse |
25 A |
End Cap |
100 kA |
0.406 in (10.3 mm) |
600 V |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CSA, UL |
Fast |
||||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
4 A |
End Cap |
100 kA |
0.406 in (10.3 mm) |
600 V |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CSA, UL |
Fast |
||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
30 A |
End Cap |
300 kA |
Rated Breaking Capacity at 300 VDC: 100000 A |
0.811 in (20.6 mm) |
J |
600 V |
0.811 x 2.252 in (20.6 x 57.2 mm) |
2.252 in (57.2 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
1.6 A |
End Cap |
6.78 J |
1.5 kA |
6.78 |
0.205 in (5.2 mm) |
250 V |
10 ms |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
BSI; CCC; CUL; CQC; IEC; IMQ; PSEJET; SEMKO; UL; VDE |
Time Delay |
||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
40 A |
End Cap |
1.72 kJ |
-40 °C (-40 °F) |
20 kA |
0.406 in (10.3 mm) |
0.394 x 1.496 in (10 x 38 mm) |
1.5 in (38.1 mm) |
125 °C (257 °F) |
||||||||||||||||||
|
Schurter Ag |
Electric Fuse |
Inline/Holder |
250 V |
150 V |
10 A |
End Cap |
400 J |
-55 °C (-67 °F) |
Gold |
1 kA |
Rated Breaking Capacity at 150 VDC: 1500 A |
Bulk |
0.205 in (5.2 mm) |
e4 |
10 ms |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CUL; VDE; UL |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
3.15 A |
End Cap |
29.795 J |
-55 °C (-67 °F) |
Tin |
100 A |
400 ms |
29.795 |
Bulk |
0.205 in (5.2 mm) |
e3 |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CE; CSA; PSE; UL |
125 °C (257 °F) |
Medium |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
65 V |
20 A |
End Cap |
192 J |
-55 °C (-67 °F) |
200 A |
1 s |
192 |
Bulk |
0.25 in (6.35 mm) |
65 V |
3AB |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CE; UL |
125 °C (257 °F) |
Very Fast |
|||||||||||
|
Littelfuse |
Electric Fuse |
20 A |
End Cap |
-55 °C (-67 °F) |
Nickel |
200 A |
4 h |
192 |
0.25 in (6.35 mm) |
Supplemental |
65 V |
3AB |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CE, UL |
125 °C (257 °F) |
Very Fast |
|||||||||||||
Siba |
Electric Fuse |
Inline/Holder |
500 V |
400 V |
1.6 A |
End Cap |
5.2 J |
1.5 kA |
Bulk |
0.25 in (6.35 mm) |
10 ms |
0.248 x 1.26 in (6.3 x 32 mm) |
0.25 x 1.252 in (6.35 x 31.8 mm) |
1.252 in (31.8 mm) |
UL |
Time Lag |
|||||||||||||||
|
Siba |
Electric Fuse |
Inline/Holder |
500 V |
300 V |
16 A |
End Cap |
2.5 kJ |
Nickel |
1.5 kA |
Bulk |
0.25 in (6.35 mm) |
20 ms |
0.248 x 1.26 in (6.3 x 32 mm) |
0.25 x 1.252 in (6.35 x 31.8 mm) |
1.252 in (31.8 mm) |
UL |
Time Lag |
|||||||||||||
|
Eska Erich Schweizer |
Electric Fuse |
Inline/Holder |
250 V |
630 mA |
End Cap |
1.52 J |
35 A |
Bulk |
0.197 in (5 mm) |
250 V |
20 ms |
0.197 x 0.787 in (5 x 20 mm) |
0.787 in (20 mm) |
CE; CUL; IEC; VDE; UL |
Time Lag |
|||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
40 A |
End Cap |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
1.063 in (27 mm) |
5.5 in (139.7 mm) |
CSA; UL |
Time Delay |
||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
40 A |
End Cap |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
1.063 in (27 mm) |
Indicator |
5.5 in (139.7 mm) |
CSA; UL |
Time Delay |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
30 A |
End Cap |
1.15 kJ |
-40 °C (-40 °F) |
20 kA |
0.406 in (10.3 mm) |
0.394 x 1.496 in (10 x 38 mm) |
1.5 in (38.1 mm) |
125 °C (257 °F) |
||||||||||||||||||
|
Schurter Ag |
Electric Fuse |
Inline/Holder |
250 V |
1.6 A |
End Cap |
755 mJ |
-55 °C (-67 °F) |
Nickel |
1.5 kA |
Box |
0.787 in (20 mm) |
20 ms |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.205 in (5.2 mm) |
CCC; CUL; KTL; METI; UL; VDE |
125 °C (257 °F) |
Very Fast |
||||||||||||
|
Schurter Ag |
Electric Fuse |
Inline/Holder |
250 V |
2.5 A |
End Cap |
3.28 J |
-55 °C (-67 °F) |
Nickel |
1.5 kA |
Box |
0.787 in (20 mm) |
20 ms |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.205 in (5.2 mm) |
CCC; CUL; KTL; METI; UL; VDE |
125 °C (257 °F) |
Very Fast |
||||||||||||
|
Schurter Ag |
Electric Fuse |
Inline/Holder |
250 V |
150 V |
5 A |
End Cap |
97.5 J |
-55 °C (-67 °F) |
Gold |
1.5 kA |
Rated Breaking Capacity at 150 VDC: 1500 A |
Bulk |
0.205 in (5.2 mm) |
e4 |
10 ms |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CUL; VDE; UL |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
1.6 A |
End Cap |
44.2 J |
-55 °C (-67 °F) |
Nickel |
150 A |
20 ms |
44.2 |
Bulk |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; CUL; PSE; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Time Lag |
||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
1.6 A |
End Cap |
2.8 J |
-55 °C (-67 °F) |
Tin |
100 A |
5 s |
Bulk |
0.25 in (6.35 mm) |
e3 |
3AG |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CE; CSA; KC; PSE; UL |
125 °C (257 °F) |
Fast |
|||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
3 A |
End Cap |
200 J |
-55 °C (-67 °F) |
Nickel |
100 A |
4 h |
200 |
Bulk |
0.25 in (6.35 mm) |
Supplemental |
250 V |
3AG |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CE; CSA; KTL; PSE; UL |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
5 A |
End Cap |
6.14 J |
-55 °C (-67 °F) |
5 kA |
2 m |
Bulk |
0.25 in (6.35 mm) |
3AB |
1.25 in (31.75 mm) |
125 °C (257 °F) |
Fast |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
17.5 A |
End Cap |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
0.811 in (20.6 mm) |
2.252 in (57.2 mm) |
CSA; UL |
Time Delay |
|||||||||||||||||
|
Bel Fuse |
Electric Fuse |
Inline/Holder |
600 V |
500 mA |
End Cap |
460 mJ |
-55 °C (-67 °F) |
Nickel |
150 A |
Box; Tape And Reel |
0.201 in (5.1 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.201 x 0.787 in (5.1 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; UL |
125 °C (257 °F) |
Time Lag |
||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
15 A |
End Cap |
200.2 J |
Nickel |
750 A |
2 m |
Pre Arcing Time: Open within 120 s at 200% Rated Current |
0.25 in (6.35 mm) |
250 V |
3AB |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CSA; UL |
Fast |
||||||||||||
Eaton Corporation |
Electric Fuse |
7 A |
End Cap |
10 kA |
0.41 in (10.41 mm) |
250 V |
0.41 x 1.38 in (10.41 x 35.05 mm) |
1.38 in (35.05 mm) |
CE, CSA, UL |
Fast |
|||||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
25 A |
End Cap |
734.69 J |
Nickel |
1.5 kA |
2 m |
Rated Breaking Capacity at 125 VDC: 10000 A |
Box |
0.25 in (6.35 mm) |
3AB |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CSA, UL |
Time Delay |
||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
20 A |
End Cap |
10 kA |
Box |
0.406 in (10.3 mm) |
250 V |
Midget |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; UL |
Time Delay |
||||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
4 A |
End Cap |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Box |
0.811 in (20.6 mm) |
0.811 x 5 in (20.6 x 127 mm) |
5 in (127 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
150 V |
5 A |
End Cap |
200 kA |
Rated Breaking Capacity at 150 VDC: 20000 A |
Box |
0.394 in (10 mm) |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.496 in (38 mm) |
CE; CSA; UL |
Time Delay |
||||||||||||||||
|
Schurter Ag |
Electric Fuse |
Inline/Holder |
250 V |
10 A |
End Cap |
141 J |
-55 °C (-67 °F) |
Nickel |
1.5 kA |
Box |
0.787 in (20 mm) |
30 ms |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.205 in (5.2 mm) |
CCC; CUL; KTL; METI; UL; VDE |
125 °C (257 °F) |
Very Fast |
||||||||||||
|
Schurter Ag |
Electric Fuse |
Inline/Holder |
250 V |
300 V |
2.5 A |
End Cap |
11.7 J |
-55 °C (-67 °F) |
Nickel |
1.5 kA |
Rated Breaking Capacity at 300 VDC: 1500 A |
11.7 |
Box |
0.205 in (5.2 mm) |
10 ms |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CUL; KTL; METI; UL; VDE |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Schurter Ag |
Electric Fuse |
Inline/Holder |
250 V |
1 A |
End Cap |
3.3 J |
-55 °C (-67 °F) |
Nickel |
35 A |
Bulk |
0.205 in (5.2 mm) |
20 ms |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CUL; METI; UL; VDE |
125 °C (257 °F) |
Time Lag |
A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.
Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.
In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.