End Cap Fuses 2,400+

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

LPJ-45SP

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

45 A

End Cap

300 kA

Rated Breaking Capacity at 300 VDC: 100000 A

1.063 in (27 mm)

J

600 V

1.063 x 2.374 in (27 x 60.3 mm)

2.374 in (60.3 mm)

CE; CSA; UL

Time Delay

LVSP0015TX2

Littelfuse

Electric Fuse

Inline/Holder

600 V

15 A

End Cap

3.267 kJ

200 kA

0.41 in (10.41 mm)

1.5 in (38.1 mm)

UL

MDA-10-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 V

10 A

End Cap

1.62 kJ

Nickel

200 A

2 m

Rated Breaking Capacity at 125 VDC: 10000 A

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA, UL

Time Delay

MDA-15

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

250 V

15 A

End Cap

206.2 J

Nickel

750 A

238.1

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA; UL

Time Delay

NON-3

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 V

3 A

End Cap

50 kA

Rated Breaking Capacity at 125 VDC: 50000 A

Box

0.56 in (14.22 mm)

K5

250 V

0.56 x 2 in (14.22 x 50.8 mm)

2 in (50.8 mm)

CE; CSA; UL

S506-1.6-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

1.6 A

End Cap

10 J

Nickel

35 A

21.7

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; IEC; IMQ; SEMKO; UL; VDE

Time Delay

0215.500MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 V

500 mA

End Cap

420 mJ

-55 °C (-67 °F)

Nickel

1.5 kA

5 ms

Pre Arcing Time: Open within 5 ms at 1000% Rated Current

0.42

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; CSA; IEC; SEMKO; SEV; UL; VDE

125 °C (257 °F)

Time Lag

021506.3HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

6.3 A

End Cap

128.75 J

-55 °C (-67 °F)

Nickel

1.5 kA

10 ms

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; CUL; KC; PSE; SEMKO; SEV; UL; VDE

125 °C (257 °F)

Time Lag

0216.250MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 mA

End Cap

8.91 mJ

-55 °C (-67 °F)

Nickel

1.5 kA

20 ms

0.0089

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; SEMKO; UL; VDE

125 °C (257 °F)

Fast

0218.400HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

400 mA

End Cap

1.325 J

-55 °C (-67 °F)

Nickel

35 A

1.325

Bulk

0.205 in (5.2 mm)

Supplemental

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; KC; SEMKO; UL; VDE

125 °C (257 °F)

Time Lag

0234001.MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

1 A

End Cap

1.975 J

-55 °C (-67 °F)

Nickel

100 A

400 ms

1.975

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; CSA; PSE; UL

125 °C (257 °F)

Medium

0285.500HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

500 mA

End Cap

300 mJ

-55 °C (-67 °F)

Gold

1.5 kA

50 ms

Bulk

0.205 in (5.2 mm)

e4

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

125 °C (257 °F)

0312004.MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

4 A

End Cap

28.5 J

-55 °C (-67 °F)

Nickel

200 A

5 s

28.5

Tape And Reel

0.25 in (6.35 mm)

250 V

3AG

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; KC; PSE; UL

125 °C (257 °F)

Fast

0313005.HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

5 A

End Cap

140 J

-55 °C (-67 °F)

Nickel

200 A

5 s

Pre Arcing Time: Open within 5 s at 200% Rated Current

140

Bulk

0.25 in (6.35 mm)

250 V

3AG

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; KTL; PSE; UL

125 °C (257 °F)

Time Lag

0314025.MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

25 A

End Cap

1.45 kJ

-55 °C (-67 °F)

Nickel

100 A

Rated Breaking Capacity at 125 VDC: 400 A

1450

Bulk

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CUL; KC; PSE; UL

125 °C (257 °F)

Fast

0322030.MXP

Littelfuse

Electric Fuse

Inline/Holder

65 V

30 A

End Cap

540 J

-55 °C (-67 °F)

200 A

1 s

540

Bulk

0.25 in (6.35 mm)

65 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; UL

125 °C (257 °F)

Very Fast

0322030MXP

Littelfuse

Electric Fuse

30 A

End Cap

-55 °C (-67 °F)

Nickel

200 A

4 h

540

0.25 in (6.35 mm)

Supplemental

65 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE, UL

125 °C (257 °F)

Very Fast

0326.010HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 V

10 mA

End Cap

1.48 mJ

-55 °C (-67 °F)

Nickel

100 A

4 h

0.0014

Bulk

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE

125 °C (257 °F)

Time Lag

0326010.HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 V

10 A

End Cap

137 J

-55 °C (-67 °F)

Nickel

400 A

4 h

137

Bulk

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; KC; PSE; UL

125 °C (257 °F)

Time Lag

189140.1

Siba

Electric Fuse

Inline/Holder

500 V

400 V

1 A

End Cap

1.4 J

Nickel

1.5 kA

Bulk

0.25 in (6.35 mm)

500 V

10 ms

0.248 x 1.26 in (6.3 x 32 mm)

1.252 in (31.8 mm)

UL

Time Lag

3SB2.5-R

Bel Fuse

Electric Fuse

Inline/Holder

125 V

2.5 A

End Cap

94 J

-55 °C (-67 °F)

Nickel

10 kA

4 h

Bulk

0.25 in (6.35 mm)

125 V

0.25 x 1.252 in (6.35 x 31.8 mm)

1.252 in (31.8 mm)

CE; CSA; PSE; UL

125 °C (257 °F)

Slow

8020.5024

Schurter Ag

Electric Fuse

Inline/Holder

400 V

63 V

20 A

End Cap

4 kJ

-40 °C (-40 °F)

1.5 kA

Rated Breaking Capacity at 63 VDC: 20000 A

Bulk

0.25 in (6.35 mm)

10 ms

0.248 x 1.26 in (6.3 x 32 mm)

0.25 x 1.252 in (6.35 x 31.8 mm)

1.252 in (31.8 mm)

CUL; UL

85 °C (185 °F)

Time Lag

8020.5024.G

Schurter Ag

Electric Fuse

Inline/Holder

400 V

63 V

20 A

End Cap

4 kJ

-40 °C (-40 °F)

1.5 kA

Rated Breaking Capacity at 63 VDC: 20000 A

Bulk

0.25 in (6.35 mm)

10 ms

0.248 x 1.26 in (6.3 x 32 mm)

0.25 x 1.252 in (6.35 x 31.8 mm)

1.252 in (31.8 mm)

CUL; UL

85 °C (185 °F)

Time Lag

ABC-6-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 V

6 A

End Cap

58 J

Nickel

200 A

2 m

Pre Arcing Time: Open within 120 s at 200% Rated Current

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA; UL

Fast

AGC-15-R

Eaton Corporation

Electric Fuse

Inline/Holder

32 V

15 A

End Cap

807.75 J

-55 °C (-67 °F)

Nickel

1 kA

Pre Arcing Time: Open within 120 s at 200% Rated Current

0.566

Box

0.25 in (6.35 mm)

32 V

0.248 x 1.26 in (6.3 x 32 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA; UL

125 °C (257 °F)

Fast

ATQR3

Mersen S A

Electric Fuse

Inline/Holder

600 V

3 A

End Cap

200 kA

0.409 in (10.4 mm)

0.409 x 1.5 in (10.4 x 38.1 mm)

1.5 in (38.1 mm)

CSA, CE, UL

80 °C (176 °F)

Time Delay

BK-AGC-15-R

Eaton Corporation

Electric Fuse

Inline/Holder

32 V

15 A

End Cap

807.75 J

-55 °C (-67 °F)

Nickel

1 kA

Pre Arcing Time: Open within 120 s at 200% Rated Current

0.566

Box

0.25 in (6.35 mm)

32 V

0.248 x 1.26 in (6.3 x 32 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA; UL

125 °C (257 °F)

Fast

BK/AGC-15-R

Cooper Industries

Electric Fuse

Inline/Holder

32 V

15 A

End Cap

566 mJ

Nickel

1 kA

0.566

Box

0.25 in (6.35 mm)

32 V

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA; UL

Fast

BK/GMA-250-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

250 mA

End Cap

18 mJ

Silver

35 A

Pre Arcing Time: OPEN within 2 MIN at 200% RATED CURRENT

0.018

Box

0.205 in (5.2 mm)

e4

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CSA; UL

Fast

BK/S506-1.6-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

1.6 A

End Cap

21.7 J

Nickel

35 A

21.7

Bulk

0.205 in (5.2 mm)

250 V

20 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

BSI; CCC; CSA; IMQ; PSE; SEMKO; UL; VDE

Time Delay

BK1/S506-1.6-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

1.6 A

End Cap

21.7 J

Nickel

35 A

21.7

Bag

0.205 in (5.2 mm)

250 V

20 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

BSI; CCC; CSA; IMQ; PSE; SEMKO; UL; VDE

Time Delay

C10G10

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

10 A

End Cap

120 kA

0.394 in (10 mm)

500 V

5AG

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

IEC

FRN-R-4

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 V

4 A

End Cap

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

Box

0.56 in (14.22 mm)

RK5

250 V

0.563 x 2 in (14.3 x 50.8 mm)

2 in (50.8 mm)

CE; CSA; UL

Time Delay

FWH-002A6F

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

2 A

End Cap

1.3 J

50 kA

Rated Breaking Capacity at 500 VDC: 50000 A

Box

0.252 in (6.4 mm)

0.252 x 1.252 in (6.4 x 31.8 mm)

1.252 in (31.8 mm)

CE; CSA; UL

FWP-40A14FI

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

700 V

40 A

End Cap

84 J

200 kA

Rated Breaking Capacity at 700 VDC: 50000 A

0.563 in (14.3 mm)

Indicator

0.563 x 2.008 in (14.3 x 51 mm)

2.008 in (51 mm)

CE; IEC; UL

GMA-500-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

500 mA

End Cap

150 mJ

Nickel

35 A

Pre Arcing Time: OPEN within 2 MIN at 200% RATED CURRENT

0.15

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

CSA; UL

Fast

KLDR005.TXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

5 A

End Cap

63.33 J

Nickel

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

CC

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

KLDR005TXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

5 A

End Cap

63.33 J

200 kA

12 s

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

KTK-20

Eaton Corporation

Electric Fuse

20 A

End Cap

100 kA

0.406 in (10.3 mm)

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CSA, UL

Fast

MDA-1-2-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

500 mA

End Cap

2.53 J

Nickel

35 A

2 m

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA, UL

Time Delay

MDA-1/2-R

Cooper Industries

Electric Fuse

500 mA

End Cap

35 A

2.53

0.25 in (6.35 mm)

250 V

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA, UL

Time Lag

MDA-12-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

32 V

12 A

End Cap

750 A

Pre Arcing Time: Open within 120 s at 200% Rated Current

0.25 in (6.35 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; UL

Time Delay

S506-3.15-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

3.15 A

End Cap

56 J

Nickel

35 A

96.4

0.205 in (5.2 mm)

250 V

20 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; IEC; IMQ; SEMKO; UL; VDE

Time Delay

S506-315-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

315 mA

End Cap

410 mJ

Nickel

35 A

0.621

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; IEC; IMQ; SEMKO; UL; VDE

Time Delay

S506-6.3-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

6.3 A

End Cap

270 J

Nickel

35 A

237.6

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; IEC; IMQ; SEMKO; UL; VDE

Time Delay

S506-63-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

63 mA

End Cap

12 mJ

Nickel

35 A

0.021

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; IEC; IMQ; SEMKO; UL; VDE

Time Delay

0034.3127

Schurter Ag

Electric Fuse

Inline/Holder

250 V

10 A

End Cap

520 J

-55 °C (-67 °F)

Nickel

100 A

Box

0.205 in (5.2 mm)

20 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CQC, CUL, METI, UL, VDE

125 °C (257 °F)

Time Lag

012010

Legrand

Electric Fuse

Inline/Holder

400 V

10 A

End Cap

-25 °C (-13 °F)

20 kA

Bulk

0.335 in (8.5 mm)

0.335 x 1.24 in (8.5 x 31.5 mm)

1.24 in (31.5 mm)

EN; IEC

40 °C (104 °F)

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.