End Cap Fuses 2,400+

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

C14G20S

Eaton Corporation

Electric Fuse

Inline/Holder

690 V

690 V

20 A

End Cap

80 kA

C14

0.551 in (14 mm)

0.551 x 2.008 in (14 x 51 mm)

2.008 in (51 mm)

IEC

FRN-R-8/10

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 V

800 mA

End Cap

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

Box

0.56 in (14.22 mm)

RK5

250 V

0.563 x 2 in (14.3 x 50.8 mm)

2 in (50.8 mm)

CE; CSA; UL

Time Delay

FRN-R-8ID

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 V

8 A

End Cap

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

Box

0.56 in (14.22 mm)

RK5

250 V

Indicator

0.56 x 2 in (14.22 x 50.8 mm)

2 in (50.8 mm)

CE; CSA; UL

Time Delay

FRS-R-35

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

35 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Box

1.063 in (27 mm)

1.063 x 5.5 in (27 x 139.7 mm)

5.5 in (139.7 mm)

CE; CSA; UL

Time Delay

KLKD025.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

25 A

End Cap

2.085 kJ

-55 °C (-67 °F)

Nickel

100 kA

4 m

0.406 in (10.31 mm)

600 V

0.394 x 1.496 in (10 x 38 mm)

1.5 x 1.5 in (38.1 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL

125 °C (257 °F)

Fast

KLKD02.5T

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

2.5 A

End Cap

-55 °C (-67 °F)

100 kA

4 m

0.406 in (10.31 mm)

600 V

0.394 x 1.496 in (10 x 38 mm)

1.5 x 1.5 in (38.1 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL; VDE

125 °C (257 °F)

Fast

KLKD02.5.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

2.5 A

End Cap

5.142 J

-55 °C (-67 °F)

100 kA

4 m

Pre Arcing Time: Clear within 4 m at 200% Rated Current; Rated Breaking Capacity at 600 VDC: 50000 A

Bulk

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL; VDE

125 °C (257 °F)

Fast

KTK-2

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

2 A

End Cap

100 kA

0.406 in (10.3 mm)

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CSA, UL

Fast

KTK-R-3/10

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 mA

End Cap

Nickel

200 kA

Box

0.406 in (10.3 mm)

CC

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Fast

MDA-2-1/2-R

Cooper Industries

Electric Fuse

Inline/Holder

250 V

125 V

2.5 A

End Cap

31.79 J

Nickel

200 A

2 m

Rated Breaking Capacity at 125 VDC: 10000 A

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA, UL

Time Delay

MDA-2-1-2-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 V

2.5 A

End Cap

31.79 J

Nickel

200 A

2 m

Rated Breaking Capacity at 125 VDC: 10000 A

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA, UL

Time Delay

XEV10-50

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

50 A

End Cap

2.74 kJ

-40 °C (-40 °F)

20 kA

0.406 in (10.3 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

125 °C (257 °F)

0001.2510

Schurter Ag

Electric Fuse

Inline/Holder

250 V

150 V

4 A

End Cap

62.4 J

-55 °C (-67 °F)

Nickel

1.5 kA

Rated Breaking Capacity at 150 VDC: 1500 A

62.4

Box

0.205 in (5.2 mm)

10 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CUL; KTL; METI; UL; VDE

125 °C (257 °F)

Time Lag

02151.25MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 V

1.25 A

End Cap

3.2 J

-55 °C (-67 °F)

Nickel

1.5 kA

10 ms

Pre Arcing Time: Open within 10 ms at 1000% Rated Current

3.2

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; KC; PSE; SEMKO; SEV; UL; VDE

125 °C (257 °F)

Time Lag

0215.125MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 V

125 mA

End Cap

33 mJ

-55 °C (-67 °F)

Tin

1.5 kA

5 ms

Pre Arcing Time: Open within 5 ms at 1000% Rated Current

0.033

Bulk

0.205 in (5.2 mm)

e3

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; IEC; SEMKO; UL

125 °C (257 °F)

Time Lag

0217.050HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

50 mA

End Cap

190 μJ

-55 °C (-67 °F)

Nickel

35 A

3 ms

0.0001

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; KC; SEMKO; UL; VDE

125 °C (257 °F)

Very Fast

0229006.HXP

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

6 A

End Cap

380 J

-55 °C (-67 °F)

Tin

400 A

4 h

380

Bulk

0.177 in (4.5 mm)

e3

125 V

2AG

Indicator

0.177 x 0.57 in (4.5 x 14.48 mm)

0.57 in (14.48 mm)

CE; CSA; PSE; UL

125 °C (257 °F)

Time Lag

0314030.HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

30 A

End Cap

2.49 kJ

-55 °C (-67 °F)

Nickel

100 A

Rated Breaking Capacity at 75 VDC: 400 A

2490

Bulk

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; KC; PSE; UL

125 °C (257 °F)

Fast

0JTD004.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

4 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.811 in (20.6 mm)

2.252 in (57.2 mm)

CSA; UL

Time Delay

0KLK01.5T

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

1.5 A

End Cap

100 kA

Rated Breaking Capacity at 500 VDC: 50000 A

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Fast

0KLK015.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

15 A

End Cap

100 kA

Rated Breaking Capacity at 500 VDC: 50000 A

0.406 in (10.31 mm)

600 V

0.394 x 1.496 in (10 x 38 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Fast

0SLC020.T

Littelfuse

Electric Fuse

20 A

End Cap

100 kA

0.406 in (10.3 mm)

G

600 V

0.406 x 1.406 in (10.3 x 35.7 mm)

1.406 in (35.7 mm)

CSA, UL

Medium

179020.2,5IP

Siba

Electric Fuse

Inline/Holder

250 V

2.5 A

End Cap

11 J

35 A

Bulk

0.205 in (5.2 mm)

250 V

20 ms

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

BEAB, SEMKO, UL, VDE

Very Fast

7012540.1

Siba

Electric Fuse

Inline/Holder

700 V

500 V

1 A

End Cap

320 mJ

Nickel

50 kA

Rated Breaking Capacity at 500 VDC: 20000 A

Bulk

0.25 in (6.35 mm)

700 V

1 ms

0.25 x 1.252 in (6.35 x 31.8 mm)

1.252 in (31.8 mm)

CUL; UL

Very Fast

8020.5073

Schurter Ag

Electric Fuse

Inline/Holder

500 V

400 V

3.15 A

End Cap

8.6 J

-40 °C (-40 °F)

1.5 kA

8.6

Bulk

0.25 in (6.35 mm)

8 ms

0.248 x 1.26 in (6.3 x 32 mm)

0.25 x 1.252 in (6.35 x 31.8 mm)

1.252 in (31.8 mm)

CUL, UL

85 °C (185 °F)

Very Fast

AGC8

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

8 A

End Cap

0.25 in (6.35 mm)

32 V

3AG

1.25 in (31.75 mm)

AGC-8

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

8 A

End Cap

152 mJ

Nickel

200 A

0.152

0.25 in (6.35 mm)

250 V

0.248 x 1.26 in (6.3 x 32 mm)

0.248 x 1.26 in (6.3 x 32 mm)

1.25 in (31.75 mm)

CSA; UL

Fast

AGU-50

Eaton Corporation

Electric Fuse

Inline/Holder

32 V

50 A

End Cap

Box

0.41 in (10.41 mm)

0.41 x 1.5 in (10.41 x 38.1 mm)

1.5 in (38.1 mm)

Fast

AGU50

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

50 A

End Cap

0.406 in (10.3187 mm)

32 V

5AG

1.5 in (38.1 mm)

ATQ1/4

Mersen S A

Electric Fuse

Inline/Holder

500 V

250 mA

End Cap

10 kA

0.394 in (10 mm)

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

CSA; UL

Time Delay

ATQ14

Mersen S A

Electric Fuse

Inline/Holder

500 V

14 A

End Cap

10 kA

0.394 in (10 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

CSA; UL

Time Delay

ATQR1/4

Mersen S A

Electric Fuse

Inline/Holder

600 V

250 mA

End Cap

Tin

200 kA

0.409 in (10.4 mm)

e3

0.409 x 1.5 in (10.4 x 38.1 mm)

1.5 in (38.1 mm)

CSA, CE, UL

80 °C (176 °F)

Time Delay

ATQR6/10

Mersen S A

Electric Fuse

Inline/Holder

600 V

600 mA

End Cap

200 kA

0.409 in (10.4 mm)

0.409 x 1.5 in (10.4 x 38.1 mm)

1.5 in (38.1 mm)

CSA, CE, UL

80 °C (176 °F)

Time Delay

BK-MDL-8-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

8 A

End Cap

47.8 J

Nickel

200 A

Box

0.25 in (6.35 mm)

250 V

0.252 x 1.248 in (6.4 x 31.7 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; UL

Time Delay

BK/MDL-8-R

Cooper Electronic Technologies

Electric Fuse

Inline/Holder

250 V

8 A

End Cap

47.8 J

200 A

MDL

Box

0.25 in (6.35 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA; UL

Time Delay

CCMR003.TXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

3 A

End Cap

286 J

Nickel

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

FNA-1

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

1 A

End Cap

200 A

0.406 in (10.31 mm)

250 V

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA, UL

Time Lag

FNM-2/10

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

200 mA

End Cap

35 A

Box

0.406 in (10.3 mm)

250 V

Midget

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

FWP-20A14FI

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

700 V

20 A

End Cap

26 J

200 kA

Rated Breaking Capacity at 700 VDC: 50000 A

0.563 in (14.3 mm)

Indicator

0.563 x 2.008 in (14.3 x 51 mm)

2.008 in (51 mm)

CE; IEC; UL

GLR-1-1/2

Eaton Corporation

Electric Fuse

Inline/Holder

300 V

1.5 A

End Cap

10 kA

0.626 in (15.9 mm)

300 V

0.626 in (15.9 mm)

CE; CSA; UL

Fast

GLR-1-6/10

Eaton Corporation

Electric Fuse

Inline/Holder

300 V

1.6 A

End Cap

10 kA

0.626 in (15.9 mm)

300 V

0.626 in (15.9 mm)

CE; CSA; UL

Fast

GLR-1/2

Eaton Corporation

Electric Fuse

Inline/Holder

300 V

500 mA

End Cap

10 kA

CE; CSA; UL

Fast

GLR-10

Eaton Corporation

Electric Fuse

Inline/Holder

300 V

10 A

End Cap

10 kA

0.626 in (15.9 mm)

300 V

0.626 in (15.9 mm)

CE; CSA; UL

Fast

GLR-12

Eaton Corporation

Electric Fuse

Inline/Holder

300 V

12 A

End Cap

10 kA

0.626 in (15.9 mm)

300 V

0.626 in (15.9 mm)

CE; UL

Fast

GLR-2

Eaton Corporation

Electric Fuse

Inline/Holder

300 V

2 A

End Cap

10 kA

0.626 in (15.9 mm)

300 V

0.626 in (15.9 mm)

CE; CSA; UL

Fast

KGJ-75

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

75 A

End Cap

200 kA

KGJ

UL

Fast

KLKR010.

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

10 A

End Cap

Nickel

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Fast

KLM-1

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

600 V

1 A

End Cap

100 kA

Bulk

0.406 in (10.3 mm)

CC

600 V

Midget

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE, CSA, UL

Fast

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.