Tab/Blade Fuses 2,400+

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

LA100P80-4TI

Littelfuse

Electric Fuse

Inline/Holder

1 KV

750 V

80 A

Tab/Blade

12 J

100 kA

Rated Breaking Capacity at 750 VDC: 100000 A

1.22 in (31 mm)

Indicator

1.22 x 6.811 in (31 x 173 mm)

6.811 in (173 mm)

UL

Very Fast

L60S90

Littelfuse

Electric Fuse

Inline/Holder

600 V

90 A

Tab/Blade

200 kA

1.063 in (27 mm)

1.063 x 2.906 in (27 x 73.8 mm)

2.906 in (73.8 mm)

CSA; UL

Fast

JLLS900

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

900 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

2.63 in (66.8 mm)

2.63 x 2.299 in (66.8 x 58.4 mm)

2.299 in (58.4 mm)

UL

Fast

TLS003V

Littelfuse

Electric Fuse

Inline/Holder

170 V

3 A

Tab/Blade

Silver

100 kA

0.563 in (14.3 mm)

e4

0.563 x 0.88 in (14.3 x 22.35 mm)

0.88 in (22.35 mm)

CE; UL

TLS090LB

Littelfuse

Electric Fuse

Inline/Holder

170 V

90 A

Tab/Blade

Silver

100 kA

0.563 in (14.3 mm)

e4

0.563 x 0.88 in (14.3 x 22.35 mm)

0.88 in (22.35 mm)

CE; UL

4998070.M-1M6

Littelfuse

Electric Fuse

Inline/Holder

70 V

70 A

Tab/Blade

10.9 kJ

-40 °C (-40 °F)

2.5 kA

70 ms

0.63 in (16 mm)

0.496 in (12.6 mm)

0.315 in (8 mm)

UL

125 °C (257 °F)

0HEV010.ZXISO

Littelfuse

Electric Fuse

Inline/Holder

450 V

10 A

Tab/Blade

255 J

-40 °C (-40 °F)

10 kA

50 ms

0.406 in (10.3 mm)

450 V

1.492 in (37.9 mm)

CSA; UL

125 °C (257 °F)

NLN225

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 V

225 A

Tab/Blade

50 kA

Rated Breaking Capacity at 250 VDC; 50000

2.094 in (53.2 mm)

2.094 x 4.878 in (53.2 x 123.9 mm)

4.878 in (123.9 mm)

CSA; UL

142.6885.5502

Littelfuse

Electric Fuse

Inline/Holder

58 V

50 A

Tab/Blade

26 kJ

142

Rated Breaking Capacity at 58 VDC: 1000 A

Bulk

1.169 in (29.7 mm)

0.358 in (9.1 mm)

1.169 x 0.358 x 0.839 in (29.7 x 9.1 x 21.3 mm)

0.839 in (21.3 mm)

DIN 72581-3; UL

0327005.UXS

Littelfuse

Electric Fuse

Inline/Holder

32 V

5 A

Tab/Blade

17 J

-40 °C (-40 °F)

Silver

1 kA

20 ms

Bulk

0.358 in (9.1 mm)

0.15 in (3.8 mm)

e4

32 V

Micro

0.311 in (7.9 mm)

125 °C (257 °F)

NH00M25

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

25 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.126 in (54 mm)

1.181 in (30 mm)

Indicator

2.126 x 1.181 x 2.22 in (54 x 30 x 56.4 mm)

2.22 in (56.4 mm)

DIN 43620; IEC; VDE

0498060.MX1M5-CN

Littelfuse

Electric Fuse

Inline/Holder

32 V

60 A

Tab/Blade

21.7 kJ

-40 °C (-40 °F)

2 kA

Bulk

0.63 in (16 mm)

0.472 in (12 mm)

0.63 x 0.472 x 0.315 in (16 x 12 x 8 mm)

0.315 in (8 mm)

UL

125 °C (257 °F)

Time Delay

0498080.M-CN

Littelfuse

Electric Fuse

Inline/Holder

32 V

80 A

Tab/Blade

24.6 kJ

-40 °C (-40 °F)

Tin

2 kA

Bulk

0.63 in (16 mm)

0.472 in (12 mm)

e3

0.63 x 0.472 x 0.315 in (16 x 12 x 8 mm)

0.315 in (8 mm)

UL

125 °C (257 °F)

Time Delay

0498030.MXTM6-CN

Littelfuse

Electric Fuse

Inline/Holder

32 V

30 A

Tab/Blade

4.2 kJ

-40 °C (-40 °F)

2 kA

Bulk

0.63 in (16 mm)

0.472 in (12 mm)

0.315 in (8 mm)

125 °C (257 °F)

Time Delay

LVSP80

Littelfuse

Electric Fuse

Inline/Holder

600 V

80 A

Tab/Blade

75 kJ

200 kA

0.816 in (20.73 mm)

0.816 x 2.25 in (20.73 x 57.15 mm)

2.25 in (57.15 mm)

UL

157.5701.6331

Littelfuse

Electric Fuse

Inline/Holder

48 V

325 A

Tab/Blade

-40 °C (-40 °F)

1.95 kA

200 ms

Bulk

1.26 in (32 mm)

0.866 in (22 mm)

48 V

1.26 x 0.866 x 0.413 in (32 x 22 x 10.5 mm)

0.413 in (10.5 mm)

CUL; UL

125 °C (257 °F)

FLNR60ID

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

60 A

Tab/Blade

200 kA

0.811 in (20.6 mm)

Indicator

0.811 x 3 in (20.6 x 76.2 mm)

3 in (76.2 mm)

CSA; UL

Time Delay

0898400.U-1M6

Littelfuse

Electric Fuse

Inline/Holder

70 V

400 A

Tab/Blade

872 kJ

-40 °C (-40 °F)

2.5 kA

100 ms

1.15 in (29.2 mm)

0.748 in (19 mm)

Mega

0.39 in (9.9 mm)

125 °C (257 °F)

Time Delay

SPFJ125

Littelfuse

Electric Fuse

Inline/Holder

600 V

1 KV

125 A

Tab/Blade

24.75 kJ

200 kA

10 m

Rated Breaking Capacity at 1000 VDC: 20000 A

1.5 in (38.1 mm)

Midget

1.5 x 3 in (38.1 x 76.2 mm)

3.012 in (76.5 mm)

CE; IEC; UL

0498030

Littelfuse

Electric Fuse

Inline/Holder

32 V

30 A

Tab/Blade

-40 °C (-40 °F)

1 kA

Rated Breaking Capacity at 32 VDC: 1000 A

0.63 in (16 mm)

0.472 in (12 mm)

0.63 x 0.472 x 0.315 in (16 x 12 x 8 mm)

0.315 in (8 mm)

UL

125 °C (257 °F)

JLLN090.VXP

Littelfuse

Electric Fuse

Inline/Holder

300 V

125 V

90 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

0.811 in (20.6 mm)

300 V

2.157 in (54.8 mm)

CE; CSA; CUL; UL

Fast

LLNRK600

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

600 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

2.594 in (65.9 mm)

2.594 x 10.374 in (65.9 x 263.5 mm)

10.374 in (263.5 mm)

CSA; UL

Time Delay

TLS080LS

Littelfuse

Electric Fuse

Inline/Holder

170 V

80 A

Tab/Blade

100 kA

0.563 in (14.3 mm)

0.563 x 0.88 in (14.3 x 22.35 mm)

0.88 in (22.35 mm)

CE; UL

TLS110V

Littelfuse

Electric Fuse

Inline/Holder

170 V

110 A

Tab/Blade

Silver

100 kA

0.563 in (14.3 mm)

e4

0.563 x 0.88 in (14.3 x 22.35 mm)

0.88 in (22.35 mm)

CE; UL

0498200

Littelfuse

Electric Fuse

Inline/Holder

32 V

200 A

Tab/Blade

-40 °C (-40 °F)

1 kA

Rated Breaking Capacity at 32 VDC: 1000 A

0.63 in (16 mm)

0.472 in (12 mm)

0.63 x 0.472 x 0.327 in (16 x 12 x 8.3 mm)

0.327 in (8.3 mm)

UL

125 °C (257 °F)

JLLS225

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

225 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

1.594 in (40.5 mm)

1.594 x 1.72 in (40.5 x 43.7 mm)

1.72 in (43.7 mm)

CSA; UL

Fast

274.4

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

400 mA

Tab/Blade

25.1 mJ

-55 °C (-67 °F)

10 kA

Rated Breaking Capacity at 125 VDC: 10000 A

0.25 in (6.35 mm)

0.25 x 0.35 in (6.35 x 8.89 mm)

0.35 in (8.89 mm)

CSA; QPL; UL

85 °C (185 °F)

Very Fast

0495060.TXA

Littelfuse

Electric Fuse

Inline/Holder

32 V

60 A

Tab/Blade

19.5 kJ

-40 °C (-40 °F)

1 kA

40 ms

0.555 in (14.1 mm)

0.472 in (12 mm)

32 V

1.063 in (27 mm)

UL

125 °C (257 °F)

Time Delay

KLPC650

Littelfuse

Electric Fuse

Inline/Holder

600 V

480 V

650 A

Tab/Blade

200 kA

Rated Breaking Capacity at 480 VDC: 20000 A

2.5 in (63.5 mm)

2.5 x 3.752 in (63.5 x 95.3 mm)

3.752 in (95.3 mm)

CSA; UL

Time Delay

CNL400

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

400 A

Tab/Blade

2.5 kA

3.181 in (80.8 mm)

2.43 in (61.72 mm)

UL

Fast

250E-3CL-15.5

Littelfuse

Electric Fuse

Inline/Holder

15.5 KV

250 A

Tab/Blade

60 kA

11.56 in (293.62 mm)

11.56 x 19.1 in (293.62 x 485.14 mm)

19.1 in (485.14 mm)

Medium

157.5700.6171

Littelfuse

Electric Fuse

Inline/Holder

48 V

175 A

Tab/Blade

-40 °C (-40 °F)

1.05 kA

200 ms

Bulk

3.228 in (82 mm)

0.787 in (20 mm)

0.039 in (1 mm)

125 °C (257 °F)

07945811495

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

4 A

Tab/Blade

18.945 J

-55 °C (-67 °F)

100 kA

284 µs

Rated Breaking Capacity at 600 VDC: 50000 A

Bulk

0.406 in (10.31 mm)

507 µs

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE; IEC; UL

125 °C (257 °F)

Fast

157.5916.6201

Littelfuse

Electric Fuse

Inline/Holder

48 V

200 A

Tab/Blade

-40 °C (-40 °F)

1.2 kA

200 ms

Bulk

3.228 in (82 mm)

0.787 in (20 mm)

0.031 in (0.8 mm)

125 °C (257 °F)

498030

Littelfuse

Electric Fuse

Inline/Holder

32 V

30 A

Tab/Blade

-40 °C (-40 °F)

1 kA

0.63 in (16 mm)

0.472 in (12 mm)

0.63 x 0.472 x 0.315 in (16 x 12 x 8 mm)

0.315 in (8 mm)

UL

125 °C (257 °F)

CCK140

Littelfuse

Electric Fuse

Inline/Holder

125 V

140 A

Tab/Blade

10 kA

1.06 in (26.92 mm)

1 x 3.579 in (25.4 x 90.91 mm)

4.72 in (119.88 mm)

Time Delay

125.6785.5102

Littelfuse

Electric Fuse

Inline/Holder

125 V

10 A

Tab/Blade

85 J

Silver

Rated Breaking Capacity at 125 VDC: 1000 A

0.469 in (11.9 mm)

0.15 in (3.8 mm)

e4

0.469 x 0.15 x 0.339 in (11.9 x 3.8 x 8.6 mm)

0.339 in (8.6 mm)

UL

NH00CM100

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

100 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.02 in (51.3 mm)

0.787 in (20 mm)

Indicator

2.02 x 0.787 x 2.126 in (51.3 x 20 x 54 mm)

2.126 in (54 mm)

VDE

153.0010.6102

Littelfuse

Electric Fuse

Inline/Holder

32 V

100 A

Tab/Blade

42.5 kJ

-40 °C (-40 °F)

2 kA

100 ms

0.63 in (16 mm)

0.472 in (12 mm)

32 V

0.307 in (7.8 mm)

CUL; ISO; UL

125 °C (257 °F)

NLS125

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

125 A

Tab/Blade

50 kA

Rated Breaking Capacity at 600 VDC; 50000

1.843 in (46.8 mm)

1.843 x 6.878 in (46.8 x 174.7 mm)

6.878 in (174.7 mm)

CSA; UL

0294050.MXJ-C

Littelfuse

Electric Fuse

Inline/Holder

32 V

50 A

Tab/Blade

-40 °C (-40 °F)

40 ms

0.864 in (21.95 mm)

0.593 in (15.05 mm)

0.929 in (23.6 mm)

125 °C (257 °F)

FLNR110ID

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

110 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

1.594 in (40.5 mm)

Indicator

1.594 x 7.126 in (40.5 x 181 mm)

7.126 in (181 mm)

CSA; QPL; UL

Time Delay

0298250.TXN

Littelfuse

Electric Fuse

Inline/Holder

32 V

250 A

Tab/Blade

389 kJ

-40 °C (-40 °F)

2 kA

Bulk

1.15 in (29.21 mm)

0.75 in (19.05 mm)

1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm)

0.42 in (10.67 mm)

125 °C (257 °F)

FLSR300.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

300 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

2.543 in (64.6 mm)

11.626 in (295.3 mm)

CSA; UL

Time Delay

NH1CG125

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

125 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.22 in (56.4 mm)

1.181 in (30 mm)

Indicator

2.22 x 1.181 x 2.835 in (56.4 x 30 x 72 mm)

2.835 in (72 mm)

VDE

997025

Littelfuse

Electric Fuse

Inline/Holder

58 V

25 A

Tab/Blade

-40 °C (-40 °F)

1 kA

Rated Breaking Capacity at 58 VDC: 1000 A

0.43 in (10.92 mm)

0.15 in (3.81 mm)

0.43 x 0.15 x 0.344 in (10.92 x 3.81 x 8.75 mm)

0.344 in (8.75 mm)

125 °C (257 °F)

Fast

153.0010.5702

Littelfuse

Electric Fuse

Inline/Holder

32 V

70 A

Tab/Blade

22 kJ

-40 °C (-40 °F)

2 kA

100 ms

0.63 in (16 mm)

0.472 in (12 mm)

32 V

0.307 in (7.8 mm)

CUL; ISO; UL

125 °C (257 °F)

156.5677.6151

Littelfuse

Electric Fuse

Inline/Holder

32 V

150 A

Tab/Blade

465 kJ

-40 °C (-40 °F)

1 kA

10 ms

Bulk

1.654 in (42 mm)

0.472 in (12 mm)

1.654 x 0.472 x 0.016 in (42 x 12 x 0.4 mm)

0.031 in (0.8 mm)

125 °C (257 °F)

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.