Tab/Blade Fuses 2,400+

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

NLN070

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 V

70 A

Tab/Blade

50 kA

Rated Breaking Capacity at 250 VDC; 50000

1.063 in (27 mm)

1.063 x 3.874 in (27 x 98.4 mm)

3.874 in (98.4 mm)

CSA; UL

0891020H

Littelfuse

Electric Fuse

Inline/Holder

58 V

20 A

Tab/Blade

420 J

-40 °C (-40 °F)

Silver

1 kA

Bulk

0.429 in (10.9 mm)

0.15 in (3.8 mm)

e4

0.429 x 0.15 x 0.331 in (10.9 x 3.8 x 8.4 mm)

0.331 in (8.4 mm)

125 °C (257 °F)

LA070URD31LI0800

Littelfuse

Electric Fuse

Inline/Holder

700 V

800 A

Tab/Blade

140 J

200 kA

2.008 in (51 mm)

2.008 in (51 mm)

Indicator

2.008 x 2.008 x 1.874 in (51 x 51 x 47.6 mm)

1.874 in (47.6 mm)

UL

Very Fast

0298275.ZXEH-LT

Littelfuse

Electric Fuse

Inline/Holder

32 V

275 A

Tab/Blade

800 kJ

-40 °C (-40 °F)

2 kA

100 ms

800000

Bulk

1.15 in (29.2 mm)

0.748 in (19 mm)

Mega

1.15 x 0.75 x 0.39 in (29.2 x 19.05 x 9.9 mm)

0.39 in (9.9 mm)

125 °C (257 °F)

Time Delay

0298125.UXP-2M8

Littelfuse

Electric Fuse

Inline/Holder

32 V

125 A

Tab/Blade

78 kJ

-40 °C (-40 °F)

Tin

2 kA

100 ms

1.15 in (29.2 mm)

0.75 in (19.05 mm)

e3

32 V

Mega

0.381 in (9.69 mm)

125 °C (257 °F)

Time Delay

KLB150

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 V

150 A

Tab/Blade

200 kA

KLB

Rated Breaking Capacity at 250 VDC: 20000 A

1.22 in (31 mm)

1.22 x 1.626 in (31 x 41.3 mm)

1.626 in (41.3 mm)

CSA; UL

Fast

0999025.ZXN

Littelfuse

Electric Fuse

Inline/Holder

58 V

25 A

Tab/Blade

2.1 kJ

-40 °C (-40 °F)

Silver

1 kA

40 ms

Bulk

1.15 in (29.2 mm)

0.35 in (8.9 mm)

e4

1.15 x 0.335 x 0.85 in (29.21 x 8.51 x 21.6 mm)

0.85 in (21.6 mm)

SAE; UL

125 °C (257 °F)

Slow

LVSP100

Littelfuse

Electric Fuse

Inline/Holder

600 V

100 A

Tab/Blade

200 kA

0.816 in (20.73 mm)

0.816 x 2.25 in (20.73 x 57.15 mm)

2.25 in (57.15 mm)

UL

NH00CM80

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

80 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.02 in (51.3 mm)

0.787 in (20 mm)

Indicator

2.02 x 0.787 x 2.126 in (51.3 x 20 x 54 mm)

2.126 in (54 mm)

VDE

KLH300

Littelfuse

Electric Fuse

Inline/Holder

500 V

450 V

300 A

Tab/Blade

200 kA

KLH

Rated Breaking Capacity at 450 VDC: 20000 A

1.5 in (38.1 mm)

1.5 x 2.094 in (38.1 x 53.2 mm)

2.094 in (53.2 mm)

CSA; UL

Fast

0298300.UX1M8

Littelfuse

Electric Fuse

Inline/Holder

32 V

300 A

Tab/Blade

315 kJ

-40 °C (-40 °F)

2 kA

100 ms

Bulk

1.15 in (29.2 mm)

0.748 in (19 mm)

32 V

Mega

0.421 in (10.7 mm)

125 °C (257 °F)

Time Delay

LLSRK400ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

400 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

2.594 in (65.9 mm)

Indicator

2.594 x 11.626 in (65.9 x 295.3 mm)

11.626 in (295.3 mm)

CSA; UL

Time Delay

KLC005

Littelfuse

Electric Fuse

Inline/Holder

600 V

5 A

Tab/Blade

-55 °C (-67 °F)

200 kA

0.563 in (14.3 mm)

1.874 in (47.6 mm)

CSA; UL

125 °C (257 °F)

Very Fast

0HEV020.ZXPY

Littelfuse

Electric Fuse

Inline/Holder

450 V

20 A

Tab/Blade

268 J

-40 °C (-40 °F)

10 kA

50 ms

0.406 in (10.3 mm)

450 V

1.531 in (38.9 mm)

CSA; UL

125 °C (257 °F)

0297004LXN

Littelfuse

Electric Fuse

Inline/Holder

32 V

4 A

Tab/Blade

17 J

-40 °C (-40 °F)

0297

Rated Breaking Capacity at 32 VDC: 1000 A

0.429 in (10.9 mm)

0.15 in (3.8 mm)

0.429 x 0.15 x 0.346 in (10.9 x 3.8 x 8.8 mm)

0.346 in (8.8 mm)

125 °C (257 °F)

FLNR.400ID

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

400 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

2.094 in (53.2 mm)

Indicator

2.094 x 8.626 in (53.2 x 219.1 mm)

8.626 in (219.1 mm)

CSA; QPL; UL

Time Delay

L13S800

Littelfuse

Electric Fuse

Inline/Holder

150 V

100 V

800 A

Tab/Blade

100 kA

L13S

Rated Breaking Capacity at 100 VDC: 20000 A

1.5 in (38.1 mm)

1.5 x 1.252 in (38.1 x 31.8 mm)

1.252 in (31.8 mm)

CSA; UL

Fast

LA100P600-4TI

Littelfuse

Electric Fuse

Inline/Holder

1 KV

750 V

600 A

Tab/Blade

650 J

100 kA

Rated Breaking Capacity at 750 VDC: 100000 A

2.5 in (63.5 mm)

Indicator

2.5 x 3.469 in (63.5 x 88.1 mm)

3.469 in (88.1 mm)

UL

Very Fast

130-4R-1BI-8.25

Littelfuse

Electric Fuse

Inline/Holder

8.25 KV

130 A

Tab/Blade

330 A

Rated Breaking Capacity=330A-80000A

3 in (76.2 mm)

Indicator

3 x 18 in (76.2 x 457.2 mm)

18 in (457.2 mm)

Medium

0498080.MXT-CN

Littelfuse

Electric Fuse

Inline/Holder

32 V

80 A

Tab/Blade

24.6 kJ

-40 °C (-40 °F)

2 kA

Bulk

0.63 in (16 mm)

0.472 in (12 mm)

0.315 in (8 mm)

UL

125 °C (257 °F)

Time Delay

0498070.MXT-CN

Littelfuse

Electric Fuse

Inline/Holder

32 V

70 A

Tab/Blade

24 kJ

-40 °C (-40 °F)

2 kA

Bulk

0.63 in (16 mm)

0.472 in (12 mm)

0.315 in (8 mm)

UL

125 °C (257 °F)

Time Delay

KLH125

Littelfuse

Electric Fuse

Inline/Holder

500 V

450 V

125 A

Tab/Blade

200 kA

KLH

Rated Breaking Capacity at 450 VDC: 20000 A

1.22 in (31 mm)

1.22 x 2.126 in (31 x 54 mm)

2.126 in (54 mm)

CSA; UL

Fast

0TLS020.TXV

Littelfuse

Electric Fuse

Inline/Holder

170 V

20 A

Tab/Blade

100 kA

Bulk

0.563 in (14.3 mm)

170 V

0.563 x 0.877 in (14.3 x 22.27 mm)

0.877 in (22.28 mm)

CUL; IEC; TUV; UL

0JLS450.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

450 A

Tab/Blade

200 kA

Bulk

2.5 in (63.5 mm)

J

600 V

2.5 x 3.752 in (63.5 x 95.3 mm)

3.752 in (95.3 mm)

CE; CSA; QPL; UL

Fast

0287030

Littelfuse

Electric Fuse

Inline/Holder

32 V

30 A

Tab/Blade

1.51 kJ

-40 °C (-40 °F)

1 kA

0.75 in (19.05 mm)

0.2 in (5.08 mm)

0.75 x 0.2 x 0.48 in (19.05 x 5.08 x 12.19 mm)

0.48 in (12.19 mm)

105 °C (221 °F)

29707.5LXN

Littelfuse

Electric Fuse

7.5 A

Tab/Blade

-40 °C (-40 °F)

Silver

1 kA

68

0.429 in (10.9 mm)

0.15 in (3.8 mm)

e4

32 V

10.85 mΩ

0.429 x 0.15 x 0.346 in (10.9 x 3.8 x 8.8 mm)

0.346 in (8.8 mm)

UL

125 °C (257 °F)

LDC601

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

601 A

Tab/Blade

200 kA

16 ms

Rated Breaking Capacity at 600 VDC: 50000 A

2.5 in (63.5 mm)

3.752 in (95.3 mm)

CE, UL

Fast

TLS-LB070

Littelfuse

Electric Fuse

Inline/Holder

170 V

70 A

Tab/Blade

Silver

Rated Breaking Capacity at 170 VDC: 100000

0.563 in (14.3 mm)

e4

0.563 x 1.367 in (14.3 x 34.72 mm)

1.367 in (34.72 mm)

UL

KLLU1500

Littelfuse

Electric Fuse

Inline/Holder

600 V

1.5 kA

Tab/Blade

200 kA

3 in (76.2 mm)

L

600 V

3 x 3.752 in (76.2 x 95.3 mm)

3.752 in (95.3 mm)

CSA; UL

Time Delay

KLKR.100

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

100 mA

Tab/Blade

Nickel

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE, CSA, UL

Fast

1652600100

Littelfuse

Electric Fuse

Inline/Holder

58 V

60 A

Tab/Blade

32 kJ

-40 °C (-40 °F)

1 kA

Bulk

1.173 in (29.8 mm)

0.358 in (9.1 mm)

40 ms

0.835 in (21.2 mm)

CUL; UL

85 °C (185 °F)

Time Lag

LA100P150-4

Littelfuse

Electric Fuse

Inline/Holder

1 KV

750 V

150 A

Tab/Blade

41 J

100 kA

Rated Breaking Capacity at 750 VDC: 100000 A

1.5 in (38.1 mm)

1.5 x 3.469 in (38.1 x 88.1 mm)

3.469 in (88.1 mm)

UL

Very Fast

0299040.L

Littelfuse

Electric Fuse

Inline/Holder

32 V

40 A

Tab/Blade

8.5 kJ

-40 °C (-40 °F)

Silver

1 kA

40 ms

8450

Bulk

1.15 in (29.2 mm)

0.346 in (8.8 mm)

e4

32 V

1.15 x 0.348 x 0.85 in (29.21 x 8.85 x 21.59 mm)

0.85 in (21.6 mm)

UL

125 °C (257 °F)

Time Delay

KLKD1/2-R

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

500 mA

Tab/Blade

-55 °C (-67 °F)

100 kA

Rated Breaking Capacity at 600 VDC: 50000 A

Bulk

0.406 in (10.31 mm)

141 µs

0.394 x 1.496 in (10 x 38 mm)

0.406 x 1.53 in (10.31 x 38.86 mm)

1.5 in (38.1 mm)

CE, UL

125 °C (257 °F)

Fast

0294040.MXJ-C

Littelfuse

Electric Fuse

Inline/Holder

32 V

40 A

Tab/Blade

-40 °C (-40 °F)

40 ms

0.864 in (21.95 mm)

0.593 in (15.05 mm)

0.929 in (23.6 mm)

125 °C (257 °F)

KLC60

Littelfuse

Electric Fuse

Inline/Holder

600 V

60 A

Tab/Blade

200 kA

0.811 in (20.6 mm)

0.811 x 2.752 in (20.6 x 69.9 mm)

2.752 in (69.9 mm)

CSA; UL

Fast

FLNR175

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

175 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

Bulk

1.535 in (39 mm)

7.126 in (181 mm)

CSA; UL

Time Delay

L70S400

Littelfuse

Electric Fuse

Inline/Holder

700 V

650 V

400 A

Tab/Blade

200 kA

Rated Breaking Capacity at 650 VDC: 20000 A

2 in (50.8 mm)

2 x 2.843 in (50.8 x 72.2 mm)

2.843 in (72.2 mm)

CE; CSA; UL

Very Fast

JLS225

Littelfuse

Electric Fuse

Inline/Holder

600 V

225 A

Tab/Blade

200 kA

Bulk

2 in (50.8 mm)

2 x 3.374 in (50.8 x 85.7 mm)

3.374 in (85.7 mm)

CE; CSA; QPL; UL

Fast

0LDC1350.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

1.35 kA

Tab/Blade

200 kA

16 ms

Rated Breaking Capacity at 600 VDC: 50000 A

3 in (76.2 mm)

L

600 V

3 x 3.752 in (76.2 x 95.3 mm)

3.752 in (95.3 mm)

CE, CSA, UL

Fast

PAL050BP

Littelfuse

Electric Fuse

Inline/Holder

50 A

Tab/Blade

Blister

PSX1XLDB0100X

Littelfuse

Electric Fuse

Inline/Holder

1.5 KV

100 A

Tab/Blade

3.54 kJ

-55 °C (-67 °F)

250 kA

Bulk

4.988 in (126.7 mm)

2.028 in (51.5 mm)

Indicator

2.028 in (51.5 mm)

CUL; UL

125 °C (257 °F)

Fast

KLC006

Littelfuse

Electric Fuse

Inline/Holder

600 V

6 A

Tab/Blade

-55 °C (-67 °F)

200 kA

0.563 in (14.3 mm)

1.874 in (47.6 mm)

CSA; UL

125 °C (257 °F)

Very Fast

168.6585.5156

Littelfuse

Electric Fuse

Through Hole Mount

32 V

15 A

Tab/Blade

178 J

Tin

1 kA

168

Rated Breaking Capacity at 32 VDC: 1000 A

Bulk

0.469 in (11.9 mm)

0.15 in (3.8 mm)

e3

0.469 x 0.15 x 0.335 in (11.9 x 3.8 x 8.5 mm)

0.335 in (8.5 mm)

UL

JLLS100.VXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

100 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.827 in (21 mm)

600 V

1.626 in (41.3 mm)

CE; CSA; UL

Fast

157.5700.5401

Littelfuse

Electric Fuse

Inline/Holder

48 V

40 A

Tab/Blade

-40 °C (-40 °F)

240 A

200 ms

Bulk

3.228 in (82 mm)

0.787 in (20 mm)

0.024 in (0.6 mm)

125 °C (257 °F)

0695025.PXP

Littelfuse

Electric Fuse

Inline/Holder

32 V

25 A

Tab/Blade

1.2 kJ

-40 °C (-40 °F)

1 kA

40 ms

Bulk

0.421 in (10.7 mm)

0.244 in (6.2 mm)

0.421 x 0.244 x 0.689 in (10.7 x 6.2 x 17.5 mm)

0.689 in (17.5 mm)

125 °C (257 °F)

0283040.U

Littelfuse

Electric Fuse

Inline/Holder

32 V

40 A

Tab/Blade

-40 °C (-40 °F)

40 ms

1.874 in (47.6 mm)

0.593 in (15.05 mm)

32 V

0.898 x 0.638 x 0.846 in (22.8 x 16.2 x 21.5 mm)

0.846 in (21.5 mm)

125 °C (257 °F)

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.