Tab/Blade Fuses 2,400+

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

L70QS060.V

Littelfuse

Electric Fuse

Inline/Holder

700 V

700 V

60 A

Tab/Blade

269 J

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 700 VDC: 50000 A

Box

1 in (25.4 mm)

2.875 in (73.03 mm)

CUL; UL

125 °C (257 °F)

Very Fast

FLSR250.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

250 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

2.543 in (64.6 mm)

11.626 in (295.3 mm)

CSA; UL

Time Delay

KLW250

Littelfuse

Electric Fuse

Inline/Holder

150 V

100 V

250 A

Tab/Blade

100 kA

KLW

Rated Breaking Capacity at 100 VDC: 20000 A

1 in (25.4 mm)

1 x 1.157 in (25.4 x 29.4 mm)

1.157 in (29.4 mm)

CSA; UL

Fast

1682150100

Littelfuse

Electric Fuse

Inline/Holder

32 V

15 A

Tab/Blade

230 J

-40 °C (-40 °F)

1 kA

Bulk

0.465 in (11.8 mm)

0.15 in (3.8 mm)

20 ms

0.339 in (8.6 mm)

DIN

85 °C (185 °F)

Very Fast

0CNN325.V

Littelfuse

Electric Fuse

Inline/Holder

125 V

48 V

325 A

Tab/Blade

2.5 kA

3.181 in (80.8 mm)

48 V

3.18 in (80.77 mm)

UL

Very Fast

142.6185.4406

Littelfuse

Electric Fuse

Inline/Holder

58 V

4 A

Tab/Blade

25 J

Tin

Rated Breaking Capacity at 58 VDC: 1000 A

0.748 in (19 mm)

0.197 in (5 mm)

e3

0.748 x 0.197 x 0.52 in (19 x 5 x 13.2 mm)

0.52 in (13.2 mm)

UL

164.6185.5306

Littelfuse

Electric Fuse

Inline/Holder

32 V

30 A

Tab/Blade

1.07 kJ

1 kA

Rated Breaking Capacity at 32 VDC: 1000 A

0.748 in (19 mm)

0.197 in (5 mm)

0.748 x 0.197 x 0.52 in (19 x 5 x 13.2 mm)

0.52 in (13.2 mm)

UL

TLN200

Littelfuse

Electric Fuse

Inline/Holder

170 V

200 A

Tab/Blade

Rated Breaking Capacity at 170 VDC: 100000 A

1.594 in (40.5 mm)

1.594 x 4.173 in (40.5 x 106 mm)

4.173 in (106 mm)

UL

Fast

TLS-L005

Littelfuse

Electric Fuse

Inline/Holder

170 V

5 A

Tab/Blade

Silver

Rated Breaking Capacity at 170 VDC: 100000

0.563 in (14.3 mm)

e4

0.563 x 1.74 in (14.3 x 44.196 mm)

1.74 in (44.196 mm)

UL

L17T125

Littelfuse

Electric Fuse

Inline/Holder

170 V

125 A

Tab/Blade

100 kA

Bulk

1 in (25.4 mm)

1 x 1.157 in (25.4 x 29.4 mm)

1.157 in (29.4 mm)

CSA; UL

PSR031UL0250Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

250 A

Tab/Blade

3.789 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.028 in (51.5 mm)

1.937 in (49.2 mm)

Indicator

3.402 in (86.4 mm)

CUL; UL

125 °C (257 °F)

Fast

0498080.MX1M5

Littelfuse

Electric Fuse

Inline/Holder

32 V

80 A

Tab/Blade

24.6 kJ

-40 °C (-40 °F)

2 kA

Bulk

0.63 in (16 mm)

0.472 in (12 mm)

0.63 x 0.472 x 0.315 in (16 x 12 x 8 mm)

0.315 in (8 mm)

UL

125 °C (257 °F)

Time Delay

273.010

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

10 mA

Tab/Blade

-55 °C (-67 °F)

10 kA

5 s

Pre Arcing Time: Open within 5 s at 200% Rated Current

0.25 in (6.35 mm)

125 V

Micro

0.25 x 0.35 in (6.35 x 8.89 mm)

0.35 in (8.89 mm)

CSA; UL

85 °C (185 °F)

Very Fast

142.5395.6222

Littelfuse

Electric Fuse

Inline/Holder

58 V

225 A

Tab/Blade

236 kJ

-40 °C (-40 °F)

1 kA

100 ms

1.142 in (29 mm)

58 V

1.142 x 0.74 x 0.366 in (29 x 18.8 x 9.3 mm)

0.37 in (9.4 mm)

UL

125 °C (257 °F)

Slow

JLS090

Littelfuse

Electric Fuse

Inline/Holder

600 V

90 A

Tab/Blade

200 kA

Bulk

1 in (25.4 mm)

1 x 2.626 in (25.4 x 66.7 mm)

2.626 in (66.7 mm)

CE; CSA; QPL; UL

Fast

LA100P200-4TI

Littelfuse

Electric Fuse

Inline/Holder

1 KV

750 V

200 A

Tab/Blade

72 J

100 kA

Rated Breaking Capacity at 750 VDC: 100000 A

1.5 in (38.1 mm)

Indicator

1.5 x 3.469 in (38.1 x 88.1 mm)

3.469 in (88.1 mm)

UL

Very Fast

0895060TXN

Littelfuse

Electric Fuse

Inline/Holder

58 V

60 A

Tab/Blade

-40 °C (-40 °F)

1 kA

Bulk

0.571 in (14.5 mm)

0.472 in (12 mm)

0.571 x 0.472 x 0.63 in (14.5 x 12 x 16 mm)

0.63 in (16 mm)

125 °C (257 °F)

157.5701.6141

Littelfuse

Electric Fuse

Inline/Holder

48 V

135 A

Tab/Blade

-40 °C (-40 °F)

810 A

200 ms

Bulk

1.26 in (32 mm)

0.866 in (22 mm)

48 V

1.26 x 0.866 x 0.413 in (32 x 22 x 10.5 mm)

0.413 in (10.5 mm)

CUL; UL

125 °C (257 °F)

L50S070

Littelfuse

Electric Fuse

Inline/Holder

500 V

450 V

70 A

Tab/Blade

200 kA

Rated Breaking Capacity at 450 VDC: 20000 A

1 in (25.4 mm)

2.126 in (54 mm)

CE; CSA; UL

Very Fast

4998040.M-1M6

Littelfuse

Electric Fuse

Inline/Holder

70 V

40 A

Tab/Blade

4.7 kJ

-40 °C (-40 °F)

2.5 kA

70 ms

0.63 in (16 mm)

0.496 in (12.6 mm)

0.315 in (8 mm)

UL

125 °C (257 °F)

157.5917.6231

Littelfuse

Electric Fuse

Inline/Holder

48 V

225 A

Tab/Blade

-40 °C (-40 °F)

1.35 kA

200 ms

Bulk

1.26 in (32 mm)

0.866 in (22 mm)

48 V

1.26 x 0.866 x 0.413 in (32 x 22 x 10.5 mm)

0.413 in (10.5 mm)

CUL; UL

125 °C (257 °F)

0294020.MXJ-C

Littelfuse

Electric Fuse

Inline/Holder

32 V

20 A

Tab/Blade

-40 °C (-40 °F)

40 ms

0.864 in (21.95 mm)

0.593 in (15.05 mm)

32 V

0.864 x 0.593 x 0.929 in (21.95 x 15.05 x 23.6 mm)

0.929 in (23.6 mm)

125 °C (257 °F)

RLN225

Littelfuse

Electric Fuse

Inline/Holder

250 V

225 A

Tab/Blade

10 kA

2.094 in (53.2 mm)

8.626 in (219.1 mm)

CE; CSA; UL

153.5631.5231

Littelfuse

Electric Fuse

Inline/Holder

32 V

23 A

Tab/Blade

1.4 kJ

-40 °C (-40 °F)

Tin

1 kA

1400

Bulk

0.63 in (16 mm)

0.472 in (12 mm)

e3

32 V

0.63 x 0.472 x 0.315 in (16 x 12 x 8 mm)

0.315 in (8 mm)

UL

125 °C (257 °F)

100-3R-1IB-2.75

Littelfuse

Electric Fuse

Inline/Holder

2.75 KV

100 A

Tab/Blade

250 A

Rated Breaking Capacity=250A-80000A

3 in (76.2 mm)

Indicator

3 x 13 in (76.2 x 330.2 mm)

13 in (330.2 mm)

Medium

0287025.L

Littelfuse

Electric Fuse

Inline/Holder

32 V

25 A

Tab/Blade

1 kJ

-40 °C (-40 °F)

Tin

1 kA

80 ms

0.752 in (19.1 mm)

0.201 in (5.1 mm)

e3

0.752 x 0.201 x 0.484 in (19.1 x 5.1 x 12.3 mm)

0.74 in (18.8 mm)

CSA; UL

125 °C (257 °F)

156.5677.5601

Littelfuse

Electric Fuse

Inline/Holder

32 V

60 A

Tab/Blade

41.4 kJ

-40 °C (-40 °F)

1 kA

10 ms

Bulk

1.654 in (42 mm)

0.472 in (12 mm)

1.654 x 0.472 x 0.016 in (42 x 12 x 0.4 mm)

0.016 in (0.4 mm)

125 °C (257 °F)

0498070.MXTM6-CN

Littelfuse

Electric Fuse

Inline/Holder

32 V

70 A

Tab/Blade

24 kJ

-40 °C (-40 °F)

2 kA

Bulk

0.63 in (16 mm)

0.472 in (12 mm)

0.315 in (8 mm)

UL

125 °C (257 °F)

Time Delay

LA30QS500-4

Littelfuse

Electric Fuse

Inline/Holder

300 V

300 V

500 A

Tab/Blade

160 J

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

1.5 in (38.1 mm)

1.5 x 1.579 in (38.1 x 40.1 mm)

1.579 in (40.1 mm)

UL

Very Fast

156.5610.5502

Littelfuse

Electric Fuse

Inline/Holder

36 V

50 A

Tab/Blade

-40 °C (-40 °F)

625 A

1 m

Bulk

1.614 in (41 mm)

0.433 in (11 mm)

0.01 in (0.25 mm)

125 °C (257 °F)

0CCK160.V

Littelfuse

Electric Fuse

Inline/Holder

125 V

160 A

Tab/Blade

10 kA

1.06 in (26.92 mm)

4.72 in (119.88 mm)

Time Delay

L60S700

Littelfuse

Electric Fuse

Inline/Holder

600 V

700 A

Tab/Blade

-55 °C (-67 °F)

200 kA

2.5 in (63.5 mm)

2.5 x 3.031 in (63.5 x 77 mm)

3.031 in (77 mm)

CSA; UL

125 °C (257 °F)

Very Fast

0891030.NXWS

Littelfuse

Electric Fuse

Inline/Holder

58 V

30 A

Tab/Blade

1.1 kJ

-40 °C (-40 °F)

1 kA

100 ms

Bulk

0.429 in (10.9 mm)

0.15 in (3.8 mm)

Mini

0.283 in (7.2 mm)

125 °C (257 °F)

2CO060

Littelfuse

Electric Fuse

Inline/Holder

600 V

250 V

60 A

Tab/Blade

200 kA

2CO

Rated Breaking Capacity at 250 VDC: 80000 A

1.024 in (26 mm)

1.024 x 2.244 in (26 x 57 mm)

2.244 in (57 mm)

CSA

153.7011.6172

Littelfuse

Electric Fuse

Inline/Holder

32 V

175 A

Tab/Blade

154.4 kJ

-40 °C (-40 °F)

2 kA

100 ms

1.142 in (29 mm)

0.642 in (16.3 mm)

32 V

0.366 in (9.3 mm)

UL

125 °C (257 °F)

Slow

157.5700.6501

Littelfuse

Electric Fuse

Inline/Holder

48 V

500 A

Tab/Blade

-40 °C (-40 °F)

3 kA

200 ms

Bulk

3.228 in (82 mm)

0.787 in (20 mm)

0.039 in (1 mm)

125 °C (257 °F)

0257020LXN

Littelfuse

Electric Fuse

Inline/Holder

32 V

20 A

Tab/Blade

520 J

-40 °C (-40 °F)

Tin/Copper

1 kA

0257

Rated Breaking Capacity at 32 VDC: 1000 A

Bulk

0.75 in (19.05 mm)

0.2 in (5.08 mm)

e2

0.75 x 0.2 x 0.48 in (19.05 x 5.08 x 12.19 mm)

0.48 in (12.19 mm)

UL

105 °C (221 °F)

SPFJ160

Littelfuse

Electric Fuse

Inline/Holder

600 V

1 KV

160 A

Tab/Blade

60.1 kJ

200 kA

10 m

Rated Breaking Capacity at 1000 VDC: 20000 A

1.5 in (38.1 mm)

Midget

1.5 x 3 in (38.1 x 76.2 mm)

3.012 in (76.5 mm)

CE; IEC; UL

0895030.U

Littelfuse

Electric Fuse

Inline/Holder

58 V

30 A

Tab/Blade

1.8 kJ

-40 °C (-40 °F)

1 kA

40 ms

Bulk

0.571 in (14.5 mm)

0.472 in (12 mm)

58 V

0.63 in (16 mm)

ISO; SAE

125 °C (257 °F)

0MIN005.VPGLO

Littelfuse

Electric Fuse

Inline/Holder

32 V

5 A

Tab/Blade

-40 °C (-40 °F)

1 kA

Blister

0.426 in (10.83 mm)

0.15 in (3.8 mm)

100 ms

Mini

Indicator

0.35 in (8.9 mm)

105 °C (221 °F)

0297004.U

Littelfuse

Electric Fuse

Inline/Holder

32 V

4 A

Tab/Blade

31 J

-40 °C (-40 °F)

1 kA

30 ms

17

0.429 in (10.9 mm)

0.15 in (3.8 mm)

32 V

Mini

0.429 x 0.15 x 0.346 in (10.9 x 3.8 x 8.8 mm)

0.346 in (8.8 mm)

UL

125 °C (257 °F)

KLKD.500HXR

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

500 mA

Tab/Blade

-55 °C (-67 °F)

100 kA

Rated Breaking Capacity at 600 VDC: 50000 A

Bulk

0.406 in (10.31 mm)

600 V

141 µs

0.394 x 1.496 in (10 x 38 mm)

1.5 x 0.406 x 1.5 in (38.1 x 10.31 x 38.1 mm)

1.5 in (38.1 mm)

CE, UL

125 °C (257 °F)

Fast

272.400

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

400 mA

Tab/Blade

25.1 mJ

-55 °C (-67 °F)

10 kA

2 s

Pre Arcing Time: Open within 2 s at 200% Rated Current

0.235 in (5.97 mm)

125 V

Micro

0.235 x 0.287 in (5.97 x 7.3 mm)

0.287 in (7.3 mm)

CSA; UL

125 °C (257 °F)

Very Fast

0299020TXN

Littelfuse

Electric Fuse

Inline/Holder

32 V

20 A

Tab/Blade

1.1 kJ

-40 °C (-40 °F)

Silver

Rated Breaking Capacity at 32 VDC: 1000 A

1.15 in (29.21 mm)

0.348 in (8.85 mm)

e4

1.15 x 0.348 x 0.85 in (29.21 x 8.85 x 21.59 mm)

0.85 in (21.59 mm)

125 °C (257 °F)

LA070URD31LI0200

Littelfuse

Electric Fuse

Inline/Holder

700 V

200 A

Tab/Blade

2.5 J

200 kA

2.008 in (51 mm)

2.008 in (51 mm)

Indicator

2.008 x 2.008 x 1.874 in (51 x 51 x 47.6 mm)

1.874 in (47.6 mm)

UL

Very Fast

LVSP5-R

Littelfuse

Electric Fuse

Inline/Holder

600 V

5 A

Tab/Blade

359 J

200 kA

0.41 in (10.41 mm)

1.53 in (38.86 mm)

UL

0498200.MXTM6-CN

Littelfuse

Electric Fuse

Inline/Holder

32 V

200 A

Tab/Blade

125 kJ

-40 °C (-40 °F)

2 kA

100 ms

Bulk

0.63 in (16 mm)

0.472 in (12 mm)

0.327 in (8.3 mm)

125 °C (257 °F)

Time Delay

SPNH125.XXDL

Littelfuse

Electric Fuse

Inline/Holder

1.5 KV

125 A

Tab/Blade

15 kJ

30 kA

Bulk

5.165 in (131.2 mm)

2.008 in (51 mm)

GPV

1.5 KV

NH

2.008 in (51 mm)

UL

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.