Tab/Blade Fuses 2,400+

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

0298300.ZXA

Littelfuse

Electric Fuse

Inline/Holder

32 V

300 A

Tab/Blade

315 kJ

-40 °C (-40 °F)

2 kA

100 ms

Bulk

1.15 in (29.2 mm)

0.748 in (19 mm)

32 V

Mega

0.421 in (10.7 mm)

125 °C (257 °F)

Time Delay

L25S450

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 V

450 A

Tab/Blade

200 kA

Rated Breaking Capacity at 250 VDC: 20000 A

1.5 in (38.1 mm)

1.5 x 1.594 in (38.1 x 40.5 mm)

1.594 in (40.5 mm)

CE; CSA; UL

Very Fast

0327010.UXS

Littelfuse

Electric Fuse

Inline/Holder

32 V

10 A

Tab/Blade

90 J

-40 °C (-40 °F)

Silver

1 kA

20 ms

Bulk

0.358 in (9.1 mm)

0.15 in (3.8 mm)

e4

32 V

Micro

0.311 in (7.9 mm)

125 °C (257 °F)

TLS001LS

Littelfuse

Electric Fuse

Inline/Holder

170 V

1 A

Tab/Blade

Silver

100 kA

0.563 in (14.3 mm)

e4

0.563 x 0.88 in (14.3 x 22.35 mm)

0.88 in (22.35 mm)

CE; UL

FLNR500ID

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

500 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

2.594 in (65.9 mm)

Indicator

2.594 x 10.374 in (65.9 x 263.5 mm)

10.374 in (263.5 mm)

CSA; QPL; UL

Time Delay

0298125.UXP-2M6

Littelfuse

Electric Fuse

Inline/Holder

32 V

125 A

Tab/Blade

78 kJ

-40 °C (-40 °F)

Tin

2 kA

100 ms

1.15 in (29.2 mm)

0.75 in (19.05 mm)

e3

32 V

Mega

0.381 in (9.69 mm)

125 °C (257 °F)

Time Delay

NH2M224

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

224 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.921 in (74.2 mm)

1.969 in (50 mm)

Indicator

2.921 x 1.969 x 2.835 in (74.2 x 50 x 72 mm)

2.835 in (72 mm)

VDE

153.5395.6102

Littelfuse

Electric Fuse

Inline/Holder

32 V

100 A

Tab/Blade

46.8 kJ

-40 °C (-40 °F)

2 kA

100 ms

1.142 in (29 mm)

0.642 in (16.3 mm)

32 V

0.366 in (9.3 mm)

UL

125 °C (257 °F)

Slow

LA30QS600-4IL

Littelfuse

Electric Fuse

Inline/Holder

300 V

300 V

600 A

Tab/Blade

230 J

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

1.5 in (38.1 mm)

1.5 x 1.579 in (38.1 x 40.1 mm)

1.579 in (40.1 mm)

UL

Very Fast

168.6785.4407

Littelfuse

Electric Fuse

Inline/Holder

32 V

4 A

Tab/Blade

16.7 J

Tin

1 kA

Bulk

0.469 in (11.9 mm)

0.15 in (3.8 mm)

e3

0.469 x 0.15 x 0.339 in (11.9 x 3.8 x 8.6 mm)

0.339 in (8.6 mm)

UL

0695015.PXPS

Littelfuse

Electric Fuse

Inline/Holder

32 V

15 A

Tab/Blade

295 J

-40 °C (-40 °F)

1 kA

40 ms

Bulk

0.421 in (10.7 mm)

0.244 in (6.2 mm)

0.421 x 0.244 x 0.689 in (10.7 x 6.2 x 17.5 mm)

0.689 in (17.5 mm)

125 °C (257 °F)

0257003.PXPV

Littelfuse

Electric Fuse

Inline/Holder

32 V

3 A

Tab/Blade

7.4 J

-40 °C (-40 °F)

Tin/Copper

1 kA

4 d 4 h

7.4

Bulk

0.75 in (19.05 mm)

0.2 in (5.08 mm)

ATO

e2

32 V

0.75 x 0.2 x 0.48 in (19.05 x 5.08 x 12.19 mm)

0.48 in (12.19 mm)

UL

105 °C (221 °F)

Fast

0695040.PXPS-HT

Littelfuse

Electric Fuse

Inline/Holder

32 V

40 A

Tab/Blade

2.5 kJ

-40 °C (-40 °F)

1 kA

40 ms

Bulk

0.421 in (10.7 mm)

0.244 in (6.2 mm)

0.689 in (17.5 mm)

125 °C (257 °F)

0498050.MX1M6-CN

Littelfuse

Electric Fuse

Inline/Holder

32 V

50 A

Tab/Blade

13 kJ

-40 °C (-40 °F)

2 kA

Bulk

0.63 in (16 mm)

0.472 in (12 mm)

0.315 in (8 mm)

UL

125 °C (257 °F)

Time Delay

0CBO125.V

Littelfuse

Electric Fuse

Inline/Holder

32 V

125 A

Tab/Blade

10 kA

0.812 in (20.62 mm)

1.623 in (41.23 mm)

Fast

KLKR001

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

1 A

Tab/Blade

80 J

Nickel

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE, CSA, UL

Fast

1251400100

Littelfuse

Electric Fuse

Inline/Holder

125 V

4 A

Tab/Blade

14.5 J

-40 °C (-40 °F)

1 kA

Bulk

0.465 in (11.8 mm)

0.15 in (3.8 mm)

20 ms

0.638 in (16.2 mm)

85 °C (185 °F)

Very Fast

0MIN030.VXGLO

Littelfuse

Electric Fuse

Inline/Holder

12 V

30 A

Tab/Blade

-40 °C (-40 °F)

1 kA

30 ms

Bulk

0.43 in (10.92 mm)

0.15 in (3.81 mm)

Mini

0.345 in (8.76 mm)

125 °C (257 °F)

581035

Littelfuse

Electric Fuse

Inline/Holder

48 V

48 V

35 A

Tab/Blade

2.5 kA

1.535 in (39 mm)

1.195 in (30.35 mm)

1.535 x 1.195 x 0.683 in (39 x 30.35 x 17.35 mm)

0.683 in (17.35 mm)

UL

KLPC3000

Littelfuse

Electric Fuse

Inline/Holder

600 V

480 V

3 kA

Tab/Blade

200 kA

Rated Breaking Capacity at 480 VDC: 20000 A

5 in (127 mm)

5 x 4 in (127 x 101.6 mm)

4 in (101.6 mm)

CSA; UL

Time Delay

0327010.YX2T

Littelfuse

Electric Fuse

Inline/Holder

32 V

10 A

Tab/Blade

90 J

-40 °C (-40 °F)

Tin

1 kA

20 ms

Bulk

0.358 in (9.1 mm)

0.15 in (3.8 mm)

e3

32 V

Micro

0.602 in (15.3 mm)

125 °C (257 °F)

0299025TXN

Littelfuse

Electric Fuse

Inline/Holder

32 V

25 A

Tab/Blade

2.087 kJ

-40 °C (-40 °F)

Silver

Rated Breaking Capacity at 32 VDC: 1000 A

1.15 in (29.21 mm)

0.348 in (8.85 mm)

e4

1.15 x 0.348 x 0.85 in (29.21 x 8.85 x 21.59 mm)

0.85 in (21.59 mm)

125 °C (257 °F)

0495030Z

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

30 A

Tab/Blade

1.48 kJ

-40 °C (-40 °F)

1 kA

Bulk

0.555 in (14.1 mm)

0.472 in (12 mm)

0.555 x 0.472 x 1.063 in (14.1 x 12 x 27 mm)

1.063 in (27 mm)

125 °C (257 °F)

Time Delay

0999080ZXN

Littelfuse

Electric Fuse

Inline/Holder

42 V

80 A

Tab/Blade

8.8 kJ

-40 °C (-40 °F)

Silver

Rated Breaking Capacity at 58 VDC: 1000 A

1.15 in (29.21 mm)

0.335 in (8.51 mm)

e4

1.15 x 0.335 x 0.872 in (29.21 x 8.51 x 22.15 mm)

0.872 in (22.15 mm)

125 °C (257 °F)

0LDC1900.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

1.9 kA

Tab/Blade

200 kA

16 ms

Rated Breaking Capacity at 600 VDC: 50000 A

3.5 in (88.9 mm)

L

600 V

3.5 x 3.752 in (88.9 x 95.3 mm)

3.752 in (95.3 mm)

CE, CSA, UL

Fast

L17T80

Littelfuse

Electric Fuse

Inline/Holder

170 V

80 A

Tab/Blade

L17T

Rated Breaking Capacity at 170 VDC: 100000 A

1 in (25.4 mm)

1 x 1.157 in (25.4 x 29.4 mm)

1.157 in (29.4 mm)

UL

Very Fast

0257015PXPV

Littelfuse

Electric Fuse

Inline/Holder

32 V

15 A

Tab/Blade

340 J

-40 °C (-40 °F)

Tin

1 kA

0257

Rated Breaking Capacity at 32 VDC: 1000 A

Bulk

0.75 in (19.05 mm)

0.2 in (5.08 mm)

e3

0.75 x 0.2 x 0.48 in (19.05 x 5.08 x 12.19 mm)

0.48 in (12.19 mm)

UL

105 °C (221 °F)

KLPC750.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

480 V

750 A

Tab/Blade

200 kA

8.626 in (219.1 mm)

L

600 V

8.626 x 3.752 in (219.1 x 95.3 mm)

3.752 in (95.3 mm)

CE; CSA; UL

Time Lag

KLW400

Littelfuse

Electric Fuse

Inline/Holder

150 V

100 V

400 A

Tab/Blade

100 kA

KLW

Rated Breaking Capacity at 100 VDC: 20000 A

1 in (25.4 mm)

1 x 1.157 in (25.4 x 29.4 mm)

1.157 in (29.4 mm)

CSA; UL

Fast

142.7010.5602

Littelfuse

Electric Fuse

Inline/Holder

58 V

60 A

Tab/Blade

16.2 kJ

-40 °C (-40 °F)

Tin

1 kA

16200

0.63 in (16 mm)

0.472 in (12 mm)

e3

58 V

0.63 x 0.472 x 0.315 in (16 x 12 x 8 mm)

0.307 in (7.8 mm)

UL

125 °C (257 °F)

0498150.MXM6-CN

Littelfuse

Electric Fuse

Inline/Holder

32 V

150 A

Tab/Blade

81.9 kJ

-40 °C (-40 °F)

2 kA

100 ms

Bulk

0.63 in (16 mm)

0.472 in (12 mm)

0.63 x 0.472 x 0.327 in (16 x 12 x 8.3 mm)

0.327 in (8.3 mm)

125 °C (257 °F)

Time Delay

162.6185.4502

Littelfuse

Electric Fuse

Inline/Holder

32 V

5 A

Tab/Blade

35 J

Tin

1 kA

Rated Breaking Capacity at 32 VDC: 1000 A

0.748 in (19 mm)

0.197 in (5 mm)

e3

0.748 x 0.197 x 0.52 in (19 x 5 x 13.2 mm)

0.52 in (13.2 mm)

UL

0298200.ZXEH-LT

Littelfuse

Electric Fuse

Inline/Holder

32 V

200 A

Tab/Blade

140 kJ

-40 °C (-40 °F)

2 kA

100 ms

140000

Bulk

1.15 in (29.2 mm)

0.748 in (19 mm)

Mega

1.15 x 0.75 x 0.39 in (29.2 x 19.05 x 9.9 mm)

0.39 in (9.9 mm)

125 °C (257 °F)

Time Delay

0998250.U-1M8

Littelfuse

Electric Fuse

Inline/Holder

70 V

250 A

Tab/Blade

240 kJ

-40 °C (-40 °F)

2.5 kA

100 ms

1.15 in (29.21 mm)

0.75 in (19.05 mm)

0.39 in (9.9 mm)

125 °C (257 °F)

0298175.UXP-2M6

Littelfuse

Electric Fuse

Inline/Holder

32 V

175 A

Tab/Blade

205.5 kJ

-40 °C (-40 °F)

Tin

2 kA

100 ms

1.15 in (29.2 mm)

0.75 in (19.05 mm)

e3

32 V

Mega

0.381 in (9.69 mm)

125 °C (257 °F)

Time Delay

0298040.UXP-2M6

Littelfuse

Electric Fuse

Inline/Holder

32 V

40 A

Tab/Blade

6.6 kJ

-40 °C (-40 °F)

Tin

2 kA

100 ms

1.15 in (29.2 mm)

0.75 in (19.05 mm)

e3

32 V

Mega

0.381 in (9.69 mm)

125 °C (257 °F)

Time Delay

LA50QS175-4

Littelfuse

Electric Fuse

Inline/Holder

500 V

500 V

175 A

Tab/Blade

15 J

200 kA

Rated Breaking Capacity at 500 VDC: 100000 A

1.22 in (31 mm)

500 V

1.22 x 2.13 in (31 x 54.1 mm)

2.13 in (54.1 mm)

CSA; UL

Fast

KLKR.750T

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

750 mA

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

CC

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE, CSA, UL

Fast

0TLS001.TXV

Littelfuse

Electric Fuse

Inline/Holder

170 V

1 A

Tab/Blade

100 kA

Bulk

0.563 in (14.3 mm)

170 V

0.563 x 0.877 in (14.3 x 22.27 mm)

0.877 in (22.28 mm)

CUL; IEC; TUV; UL

L17T500

Littelfuse

Electric Fuse

Inline/Holder

170 V

500 A

Tab/Blade

100 kA

Bulk

1.5 in (38.1 mm)

1.5 x 1.252 in (38.1 x 31.8 mm)

1.252 in (31.8 mm)

CSA; UL

153.7010.5601

Littelfuse

Electric Fuse

Inline/Holder

32 V

60 A

Tab/Blade

16.2 kJ

Tin

2 kA

Bulk

0.63 in (16 mm)

0.472 in (12 mm)

e3

0.63 x 0.472 x 0.315 in (16 x 12 x 8 mm)

0.315 in (8 mm)

UL

0581040

Littelfuse

Electric Fuse

Inline/Holder

48 V

48 V

40 A

Tab/Blade

2.5 kA

1.535 in (39 mm)

1.195 in (30.35 mm)

48 V

1.535 x 0.683 in (39 x 17.35 mm)

0.683 in (17.35 mm)

UL

Fast

IDSR080.V

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

80 A

Tab/Blade

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

1.283 in (32.6 mm)

7.874 in (200 mm)

CSA; UL

Time Delay

JLLS1200

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

1.2 kA

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

2.63 in (66.8 mm)

2.63 x 2.299 in (66.8 x 58.4 mm)

2.299 in (58.4 mm)

UL

Fast

MIN30

Littelfuse

Electric Fuse

Inline/Holder

32 V

30 A

Tab/Blade

1.1 kJ

-40 °C (-40 °F)

1 kA

30 ms

Box

0.429 in (10.9 mm)

0.15 in (3.8 mm)

0.346 in (8.8 mm)

UL

125 °C (257 °F)

0498200.MXTM6

Littelfuse

Electric Fuse

Inline/Holder

32 V

200 A

Tab/Blade

125 kJ

-40 °C (-40 °F)

2 kA

100 ms

Bulk

0.63 in (16 mm)

0.472 in (12 mm)

0.327 in (8.3 mm)

125 °C (257 °F)

Time Delay

0294100.MXJ-C

Littelfuse

Electric Fuse

Inline/Holder

32 V

100 A

Tab/Blade

-40 °C (-40 °F)

40 ms

0.864 in (21.95 mm)

0.593 in (15.05 mm)

0.929 in (23.6 mm)

125 °C (257 °F)

0CNN125.V

Littelfuse

Electric Fuse

Inline/Holder

125 V

48 V

125 A

Tab/Blade

2.5 kA

3.181 in (80.8 mm)

125 V

3.18 in (80.77 mm)

UL

Very Fast

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.