Tab/Blade Fuses 2,400+

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

IDSR125

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

125 A

Tab/Blade

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

1.787 in (45.4 mm)

1.752 x 9.626 in (44.5 x 244.5 mm)

9.626 in (244.5 mm)

CSA; UL

Time Delay

SPF030.HXR

Littelfuse

Electric Fuse

Inline/Holder

1 KV

30 A

Tab/Blade

2.679 kJ

20 kA

4 m

Bulk

0.406 in (10.31 mm)

Midget

1.5 in (38.1 mm)

UL

JLLS150

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

150 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

1.063 in (27 mm)

1.063 x 1.657 in (27 x 42.1 mm)

1.657 in (42.1 mm)

CSA; UL

Fast

142.7010.6102

Littelfuse

Electric Fuse

Inline/Holder

58 V

100 A

Tab/Blade

42.5 kJ

-40 °C (-40 °F)

1 kA

0.63 in (16 mm)

0.472 in (12 mm)

0.307 in (7.8 mm)

UL

125 °C (257 °F)

LA130URD71IL0160

Littelfuse

Electric Fuse

Inline/Holder

1.3 KV

160 A

Tab/Blade

2.6 J

100 kA

2.008 in (51 mm)

2.008 in (51 mm)

Indicator

2.008 x 2.008 x 2.854 in (51 x 51 x 72.5 mm)

2.854 in (72.5 mm)

UL

Very Fast

168.6785.4102

Littelfuse

Electric Fuse

Inline/Holder

32 V

1 A

Tab/Blade

830 mJ

Tin

1 kA

Rated Breaking Capacity at 32 VDC: 1000 A

Bulk

0.469 in (11.9 mm)

0.15 in (3.8 mm)

e3

0.469 x 0.15 x 0.339 in (11.9 x 3.8 x 8.6 mm)

0.339 in (8.6 mm)

UL

250E-2CL-5.5

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

250 A

Tab/Blade

80 kA

7.94 in (201.68 mm)

7.94 x 16.13 in (201.68 x 409.7 mm)

16.13 in (409.7 mm)

Medium

272.500

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

500 mA

Tab/Blade

71.6 mJ

-55 °C (-67 °F)

Bright Tin

10 kA

Rated Breaking Capacity at 125 VDC: 10000 A

0.235 in (5.97 mm)

e3

0.235 x 0.287 in (5.97 x 7.3 mm)

0.287 in (7.3 mm)

CSA; UL

125 °C (257 °F)

Very Fast

TLS030LB

Littelfuse

Electric Fuse

Inline/Holder

170 V

30 A

Tab/Blade

Silver

100 kA

0.563 in (14.3 mm)

e4

0.563 x 0.88 in (14.3 x 22.35 mm)

0.88 in (22.35 mm)

CE; UL

KLB600

Littelfuse

Electric Fuse

Inline/Holder

250 V

200 V

600 A

Tab/Blade

200 kA

KLB

Rated Breaking Capacity at 200 VDC: 20000 A

1.5 in (38.1 mm)

1.5 x 1.594 in (38.1 x 40.5 mm)

1.594 in (40.5 mm)

CSA; UL

Fast

156.5611.5301

Littelfuse

Electric Fuse

Inline/Holder

36 V

30 A

Tab/Blade

-40 °C (-40 °F)

375 A

1 m

Bulk

0.709 in (18 mm)

0.551 in (14 mm)

36 V

1.614 x 0.551 x 0.256 in (41 x 14 x 6.5 mm)

0.256 in (6.5 mm)

125 °C (257 °F)

0998125.UX-1M6

Littelfuse

Electric Fuse

Inline/Holder

70 V

125 A

Tab/Blade

38 kJ

-40 °C (-40 °F)

Tin

2.5 kA

100 ms

Bulk

1.15 in (29.2 mm)

0.748 in (19 mm)

e3

70 V

Mega

0.39 in (9.9 mm)

ISO

125 °C (257 °F)

PSR071UL0280Z

Littelfuse

Electric Fuse

Inline/Holder

1.3 KV

1 KV

280 A

Tab/Blade

13.763 kJ

-55 °C (-67 °F)

100 kA

Rated Breaking Capacity at 1000 VDC: 150000 A

Bulk

2.882 in (73.2 mm)

2.028 in (51.5 mm)

Indicator

3.402 in (86.4 mm)

CUL; UL

125 °C (257 °F)

Fast

JLLN110.XXP

Littelfuse

Electric Fuse

Inline/Holder

300 V

125 V

110 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

1.063 in (27 mm)

300 V

2.437 in (61.9 mm)

CE; CSA; CUL; UL

Fast

2CO025

Littelfuse

Electric Fuse

Inline/Holder

600 V

250 V

25 A

Tab/Blade

200 kA

2CO

Rated Breaking Capacity at 250 VDC: 80000 A

0.827 in (21 mm)

0.827 x 2.205 in (21 x 56 mm)

2.205 in (56 mm)

CSA

CNL050

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

50 A

Tab/Blade

2.5 kA

3.181 in (80.8 mm)

2.43 in (61.72 mm)

UL

Fast

0695040.PXPS

Littelfuse

Electric Fuse

Inline/Holder

32 V

40 A

Tab/Blade

1.4 kJ

-40 °C (-40 °F)

1 kA

40 ms

Bulk

0.421 in (10.7 mm)

0.244 in (6.2 mm)

0.421 x 0.244 x 0.689 in (10.7 x 6.2 x 17.5 mm)

0.689 in (17.5 mm)

125 °C (257 °F)

0298450.UXP-NH

Littelfuse

Electric Fuse

Inline/Holder

32 V

450 A

Tab/Blade

1.324 MJ

-40 °C (-40 °F)

Tin

2 kA

1.15 in (29.2 mm)

0.75 in (19.05 mm)

e3

32 V

Mega

0.389 in (9.89 mm)

125 °C (257 °F)

Time Delay

153.7011.6152

Littelfuse

Electric Fuse

Inline/Holder

32 V

150 A

Tab/Blade

113.4 kJ

-40 °C (-40 °F)

2 kA

100 ms

1.142 in (29 mm)

0.642 in (16.3 mm)

32 V

0.366 in (9.3 mm)

UL

125 °C (257 °F)

Slow

0257025LXN

Littelfuse

Electric Fuse

Inline/Holder

32 V

25 A

Tab/Blade

1.08 kJ

-40 °C (-40 °F)

Tin

1 kA

0257

Rated Breaking Capacity at 32 VDC: 1000 A

Bulk

0.75 in (19.05 mm)

0.2 in (5.08 mm)

e3

0.75 x 0.2 x 0.48 in (19.05 x 5.08 x 12.19 mm)

0.48 in (12.19 mm)

UL

105 °C (221 °F)

0298150.UXP-2M6

Littelfuse

Electric Fuse

Inline/Holder

32 V

150 A

Tab/Blade

97.3 kJ

-40 °C (-40 °F)

Tin

2 kA

100 ms

1.15 in (29.2 mm)

0.75 in (19.05 mm)

e3

32 V

Mega

0.381 in (9.69 mm)

125 °C (257 °F)

Time Delay

164.6185.5302

Littelfuse

Electric Fuse

Inline/Holder

32 V

30 A

Tab/Blade

1.07 kJ

Tin

1 kA

Rated Breaking Capacity at 32 VDC: 1000 A

Bulk

0.748 in (19 mm)

0.197 in (5 mm)

e3

0.748 x 0.197 x 0.52 in (19 x 5 x 13.2 mm)

0.52 in (13.2 mm)

UL

FLSR225.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

225 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

2.543 in (64.6 mm)

11.626 in (295.3 mm)

CSA; UL

Time Delay

IDSR110

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

110 A

Tab/Blade

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

1.787 in (45.4 mm)

1.752 x 9.626 in (44.5 x 244.5 mm)

9.626 in (244.5 mm)

CSA; UL

Time Delay

LLNRK400

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

400 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

2.094 in (53.2 mm)

2.094 x 8.626 in (53.2 x 219.1 mm)

8.626 in (219.1 mm)

CSA; UL

Time Delay

TLS-V035

Littelfuse

Electric Fuse

Inline/Holder

170 V

35 A

Tab/Blade

Silver

Rated Breaking Capacity at 170 VDC: 100000

0.563 in (14.3 mm)

e4

0.563 x 1.26 in (14.3 x 32.004 mm)

1.26 in (32.004 mm)

UL

LA70QS350-4

Littelfuse

Electric Fuse

Inline/Holder

700 V

700 V

350 A

Tab/Blade

72 J

200 kA

Rated Breaking Capacity at 700 VDC: 100000 A

1.5 in (38.1 mm)

1.5 x 2.843 in (38.1 x 72.2 mm)

2.843 in (72.2 mm)

CSA; UL

Fast

L50S70

Littelfuse

Electric Fuse

Inline/Holder

500 V

450 V

70 A

Tab/Blade

200 kA

Rated Breaking Capacity at 450 VDC: 20000 A

1 in (25.4 mm)

1 x 2.126 in (25.4 x 54 mm)

2.126 in (54 mm)

CSA; UL

Fast

PSR031US0450Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

450 A

Tab/Blade

22.457 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.028 in (51.5 mm)

1.937 in (49.2 mm)

Indicator

3.402 in (86.4 mm)

CUL; UL

125 °C (257 °F)

Fast

KLPC0700

Littelfuse

Electric Fuse

Inline/Holder

600 V

480 V

700 A

Tab/Blade

200 kA

Rated Breaking Capacity at 480 VDC: 20000 A

2.5 in (63.5 mm)

2.5 x 3.752 in (63.5 x 95.3 mm)

3.752 in (95.3 mm)

CSA; UL

Time Delay

SPFJ125L

Littelfuse

Electric Fuse

Inline/Holder

600 V

1 KV

125 A

Tab/Blade

24.75 kJ

200 kA

10 m

Rated Breaking Capacity at 1000 VDC: 20000 A

1.5 in (38.1 mm)

Midget

3.012 in (76.5 mm)

CE; IEC; UL

0327003.LXS

Littelfuse

Electric Fuse

Inline/Holder

32 V

3 A

Tab/Blade

9 J

-40 °C (-40 °F)

Silver

1 kA

20 ms

Bulk

0.358 in (9.1 mm)

0.15 in (3.8 mm)

e4

32 V

Micro

0.602 in (15.3 mm)

125 °C (257 °F)

0298400.ZXB

Littelfuse

Electric Fuse

Inline/Holder

32 V

400 A

Tab/Blade

610 kJ

-40 °C (-40 °F)

2 kA

100 ms

Bulk

1.15 in (29.2 mm)

0.748 in (19 mm)

Mega

0.421 in (10.7 mm)

125 °C (257 °F)

Time Delay

IDSR175.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

175 A

Tab/Blade

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

1.787 in (45.4 mm)

9.626 in (244.5 mm)

CSA; UL

Time Delay

0TLS025.TXLS

Littelfuse

Electric Fuse

Inline/Holder

170 V

25 A

Tab/Blade

100 kA

Bulk

0.563 in (14.3 mm)

170 V

0.563 x 0.877 in (14.3 x 22.27 mm)

0.877 in (22.28 mm)

CUL; IEC; TUV; UL

0495050.Z

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

50 A

Tab/Blade

8.75 kJ

-40 °C (-40 °F)

1 kA

Bulk

0.555 in (14.1 mm)

0.472 in (12 mm)

0.555 x 0.472 x 1.063 in (14.1 x 12 x 27 mm)

1.063 in (27 mm)

125 °C (257 °F)

Time Delay

0898400.U-2M6

Littelfuse

Electric Fuse

Inline/Holder

70 V

400 A

Tab/Blade

872 kJ

-40 °C (-40 °F)

2.5 kA

100 ms

1.15 in (29.2 mm)

0.748 in (19 mm)

Mega

0.39 in (9.9 mm)

125 °C (257 °F)

Time Delay

KLLU2000.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

2 kA

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

3.5 in (88.9 mm)

3.752 in (95.3 mm)

CE; CSA; UL

Time Delay

0998060.U-2M8

Littelfuse

Electric Fuse

Inline/Holder

70 V

60 A

Tab/Blade

25 kJ

-40 °C (-40 °F)

2.5 kA

100 ms

1.15 in (29.21 mm)

0.75 in (19.05 mm)

0.39 in (9.9 mm)

125 °C (257 °F)

299070

Littelfuse

Electric Fuse

Inline/Holder

32 V

70 A

Tab/Blade

6.9 kJ

Silver

1 kA

Rated Breaking Capacity at 32 VDC: 1000 A

1.15 in (29.21 mm)

0.348 in (8.85 mm)

e4

1.15 x 0.348 x 0.85 in (29.21 x 8.85 x 21.59 mm)

0.85 in (21.59 mm)

UL

Slow

LA70QS700-4

Littelfuse

Electric Fuse

Inline/Holder

700 V

700 V

700 A

Tab/Blade

332 J

200 kA

Rated Breaking Capacity at 700 VDC: 100000 A

2.5 in (63.5 mm)

2.5 x 2.843 in (63.5 x 72.2 mm)

2.843 in (72.2 mm)

CSA; UL

Fast

L17T800

Littelfuse

Electric Fuse

Inline/Holder

170 V

800 A

Tab/Blade

100 kA

Bulk

1.5 in (38.1 mm)

1.5 x 1.252 in (38.1 x 31.8 mm)

1.252 in (31.8 mm)

CSA; UL

L25S90

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 V

90 A

Tab/Blade

200 kA

Rated Breaking Capacity at 250 VDC: 20000 A

1.22 in (31 mm)

1.22 x 1.626 in (31 x 41.3 mm)

1.626 in (41.3 mm)

CSA; UL

Fast

0998450.UX-1M6

Littelfuse

Electric Fuse

Inline/Holder

70 V

450 A

Tab/Blade

1.224 MJ

-40 °C (-40 °F)

Tin

2.5 kA

100 ms

Bulk

1.15 in (29.2 mm)

0.748 in (19 mm)

e3

70 V

Mega

0.39 in (9.9 mm)

ISO

125 °C (257 °F)

0CBO150.V

Littelfuse

Electric Fuse

Inline/Holder

32 V

150 A

Tab/Blade

10 kA

0.812 in (20.62 mm)

1.623 in (41.23 mm)

Fast

550-30R-2BI-5.5

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

550 A

Tab/Blade

2.4 kA

Rated Breaking Capacity=2400A-80000A

7.6 in (193.04 mm)

Indicator

7.6 x 18 in (193.04 x 457.2 mm)

18 in (457.2 mm)

Medium

SPNH0160.XXDLMS

Littelfuse

Electric Fuse

Inline/Holder

1.5 KV

160 A

Tab/Blade

19 kJ

30 kA

Bulk

5.165 in (131.2 mm)

2.008 in (51 mm)

NH

2.008 in (51 mm)

UL

LLSRK500ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

500 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

3.094 in (78.6 mm)

Indicator

3.094 x 13.374 in (78.6 x 339.7 mm)

13.374 in (339.7 mm)

CSA; UL

Time Delay

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.